본 연구는 연약지반상에 sand drain을 타설하고 성토하여 교대 및 교각을 시공하는 진월 인터체인지에서 기초지반의 침하, 융기 및 이미 시공된 교각기초부분의 수평방향 변위를 측정한 실측치와 Sekiguchi의 탄 점소성모델을 Biot의 압밀방정식과 결합하여 2차원 평면변형용조건으로 유한요소해석한 결과를 비교 검토하였다. 이때 교각기초인 강판말뚝은 등가의 강널말뚝벽으로 환산하였다. 그리고 환산한 벽체에 축력의 변화, 강성의 변화, 지지조건의 변화 및 고정점위치의 변화 동에 따른 기초지반의 거동과 강널말뚝벽체의 거동 특성을 밝혔다.
A contamination event occurring in water distribution networks (WDNs) needs to be handled with the appropriate mitigation strategy to protect public health safety and ensure water supply service continuation. Typically the mitigation phase consists of contaminant sensing, public warning, network inspection, and recovery. After the contaminant source has been detected and treated, contaminants still exist in the network, and the contaminated water should be flushed out. The recovery period is critical to remove any lingering contaminant in a rapid and non-detrimental manner. The contaminant flushing can be done in several ways. Conventionally, the opening of hydrants is applied to drain the contaminant out of the system. Relying on advanced information and communication technology (ICT) on WDN management, warning and information can be distributed fast through electronic media. Water utilities can inform their customers to participate in the contaminant flushing by opening and closing their house faucets to drain the contaminated water. The household draining strategy consists of determining sectors and timeslots of the WDN users based on hydraulic simulation. The number of sectors should be controlled to maintain sufficient pressure for faucet draining. The draining timeslot is determined through hydraulic simulation to identify the draining time required for each sector. The effectiveness of the strategy is evaluated using three measurements, such as Wasted Water (WW), Flushing Duration (FD), and Pipe Erosion (PE). The optimal draining strategy (i.e., group and timeslot allocation) in the WDN can be determined by minimizing the measures.
본 연구는 기존 원심력 철근콘크리트관의 성능을 향상시킬 수 있는 방법으로 관체 표면을 일정한 두께로 방식 라이닝 모르타르로 처리함으로써 보다 더 내구적인 하수관을 개발하기 위하여 실시하였다. 이를 위해 원심력 철근콘크리트관 제작 시, 동시성형이 가능하고 촉진 증기양생 조건에서도 균열이 발생되지 않는 접착강도가 큰 폴리머 시멘트 모르타르를 제조하였다. 폴리머 시멘트 모르타르를 원심력 철근콘크리트관용 라이닝 재료로 사용하기 위한 기초적 실험결과, 보통 시멘트 모르타르에 비해 역학적 성질 및 내구성이 우수하였으며, 현장적용결과, 동시성형 및 양생조건에 따라 적용될 수 있는 방법은 다양하나, 폴리머의 종류에 관계없이 폴리머 시멘트비를 20% 이하로 하며, 양생온도는 8$0^{\circ}C$이하의 양생조건을 제안할 수 있었다. 또한 현장조건이 가능하면, 2일간 기중양생(2$0^{\circ}C$)을 실시하여 폴리머 시멘트 모르타르 속의 폴리머 필름이 형성된 후, 8$0^{\circ}C$에서 양생시키는 방법이 이상적인 것으로 나타났다.
배수 시스템에서 오염퇴적물이 장기간 발생하게 되면 배수관 폐색현상을 일으켜 유지관리가 어렵고 배수관의 잔류수압이 커져 파손의 위험이 있다. 이에 본 연구에서는 PVDF 필름에 의해 발생하는 진동에너지를 활용하여 물리/화학적 폐색에 의한 터널배수 시스템 폐색을 감소시키는 시스템을 구축하였다. 또한, PVDF 필름을 기존 배수재와 융합한 하이브리드 배수재와 역압전 효과를 일으킬 수 있는 구동장치로 배수재 유지관리 시스템을 개발하였다. 터널 배수관 유지관리 성능을 고찰하기 위하여 실내조건에서 오염퇴적물을 모사하고 진동조건에서 폐색저감 효율을 관찰하였다. 그 결과 개발된 PVDF 필름 구동 장비로 20분 내외의 진동에너지를 발생하여 씻겨나간 오염퇴적물의 잔류면적을 측정한 결과 74.62%의 오염퇴적물 제거효과를 볼 수 있었다. 현장 적용성 평가를 위하여 PVDF 필름을 배수관에 부착하고 장기적으로 음압측정을 하여 실내실험으로부터의 측정 음압과 비교하여 현장실험의 대응율을 제시하였다. 현장실험은 터널 배수관으로부터 내부에 폐색이 주로 발생하는 구간인 종배수관과 횡배수관에 PVDF 필름을 부착하였고 터널현장 음압측정 실험으로부터 오염물퇴적 제거효율은 실내실험대비 현장 대응율은 90% 이상으로 확인됐다.
시설재배지에서의 암거 배수 효과를 보기 위하여 2W 연동하우스 강서 미사질 양토를 대상으로 3년간 실시하였다. 암거 무설치구와 암거 설치구를 두고 암거설치구는 간격 1 m, 2 m 및 3 m로 하여 3개의 구를 두고 암거설치는 유공 PVC관(${\Phi}100mm$)을 비닐 망사로 감아 깊이 50-60 cm에 묻고 관 주위 10 cm 정도를 왕겨로 충진한 후 토양으로 덮었다. 작부체계는 1 년차에는 호박-호박, 2년차에 오이-시금치-쑥갓-시금치-열무, 3년차에 풋고추-토마토-시금치였으며 시비는 관행시비, 관개는 지하수 양수에 의한 점적관개나 고랑관개를 이용했다. 암거 설치구는 무처리구에 비해 용적밀도, 토양경도가 낮았고 최종직물인 시금치의 근권이 2 cm 이상 더 컸다. 암거 설치에 의해 토양수분함량의 감소가 조사되었고 암거간격이 좁아질수록 현저하게 낮아지는 경향을 보였으며 암거 직상부가 대체로 가장 낮은 토양수분함량을 나타내었다. 따라서 암거 설치는 통기성, 투수성 등의 토양 물리성 개선시켰으며 암거직상부에서 그 효과가 가장 크다고 파악된다. 암거 설치에 의해 토양표면 (0-10 cm)의 $NO_{3^-}-N$함량의 감소폭이 가장 컸고 염농도 및 유효인산, 교환성양이온함량 또한 감소했다. 특히 계절별로 집적량이 높은 봄에 염농도 및 $NO_{3^-}-N$ 함량 감소율 또한 높았고 여름, 가을은 상대적으로 낮았다. 암거 설치에 의해 토양표면의 EC(1:5)는 $1.22dS\;m^{-1}$에서 $0.82dS\;m^{-1}$로 감소했고 $NO_{3^-}-N$ 함량은 $200mg\;kg^{-1}$에서 $39mg\;kg^{-1}$로 감소했다. 암거 설치 3년간의 작물수량은 작목에 따라 다르게 나타났는데, 무처리구에 비해 2 m 간격이 18.2% 증수, 3 m 간격이 14.2% 증수 및 1 m 간격은 0.2% 감수되었다.
Recently, underground pipes are utilized in various fields of applications such as sewer lines, drain lines, water mains, gas lines, telephone and electrical conduits, culverts, oil lines, etc. Most of pipes are installed for long-term purposes and they should be safely installed in consideration of installation conditions because there are unexpected various terrestrial loading conditions. In this paper, we present the result of investigation pertaining to the structural behavior of glass fiber reinforced thermosetting polymer plastic (GFRP) flexible pipes buried underground. The mechanical properties of the GFRP flexible pipes produced in the domestic manufacturer are determined and the results are reported in this paper. In addition, ring deflection is measured by the field tests and the finite element analysis (FEA) is also conducted to simulate the structural behavior of GFRP pipes buried underground. From the field test results, we predicted long-term, up to 50 years, ring deflection of GFRP pipes buried underground based on the method suggested by the existing literature. It was found that the GFRP flexible pipe to be used for cooling water intake system in the nuclear power plant is appropriate because 5% ring deflection limitation for 50 years could be satisfied.
도시유역의 유출분석을 위하여 국내에서 많이 사용하고 있는 모형들로는 ILLVDAS, SWMM이 대표적이라고 할 수 있다. 그러나 국내의 대부분의 도시하천의 경우 합류식의 배수계통을 가지고 있어, 홍수시에 하수관거용량을 초과하는 우수량은 하천을 통해 배수가 되고 있다. 이러한 배수계통을 갖는 하천에 대하여 대상유역의 배수관망 자료 부족과 Modeling의 어려움으로 인해 도시유출모형이 아닌 HEC-HMS 모형과 같은 유역추적법을 통해 유출분석이 이루어지고 있다. 또한 기존 논문에서 제시한 도시유출모형에 하도추적을 결합한 강우-유출 모의는 정확성 결여 및 번거로운 단점이 있다. 따라서 본 논문에서는 보다 안정적인 해석 모형인 MIKE SWMM 모형을 사용하여 과거 침수자료와 DEM 자료 및 수치 배수관망 자료를 통한 유역 및 배수관망 자료를 구축하고 유역에 대해서는 Runoff Block을 사용하고, 하수관거와 본류에 대해서는 Dynamic 방정식을 이용한 Extran Block을 적용하여 유출분석을 실시하고 그 결과를 기존의 방법들과 비교하여 각각의 장단점 및 적용성을 밝히고 개선방향등을 제시하고자 하였다.
Seoul Metropolitan Rapid Transit Corporation has 148's stations. Total length is 152km and most of the station is located in the basement and Groundwater occur inflow of 700,000 tons per day. Groundwater is treated as a natural flow way instead of artificial ways. Therefore, most of the collection wells is located in the low place or station for the efficient induction and collecting water. Manhole overtopping is occurring frequently because groundwater is concentrated in the drain pipe near the collecting well and heavy rainfall in summer. As a result, ballast contamination and radon levels are increased in tunnel. This paper introduces a solution is increasing overflow in tunnel, which introduces drainage system of non-motorized that uses differencial head between collecting well and manhole.
A computational study on the improvement of the pressure loss of intake system, which is located at engine manifold of the combat vehicle, has been conducted using a finite-volume-based, Reynolds-Averaged Navier-Stokes (RANS) solver. The computational result of the pressure loss through the air cleaner is in good agreement with equivalent experimental data. A parametric study was done for improving of the pressure loss of intake system over the baseline case. The effects of five primary parameters such as the height of inlet, the width of interconnection pipe, the shape of drain chamber and the diameter of filter housing were considered in this study. Consequently, this computational investigation can contribute to finding an optimal guideline for the idea of improvement in the pressure loss of intake system.
Recently Among indoor noises plumbing noise from supply and drain water pipe is being pointed out as a annoying noise following to floor impact noise, and it is increasing the rate to point the noise due to the following several reasons: water pressure, vibration by fabricated structures and direct noise propagation from upper floor through ceiling This study aims to analyse the characteristics of toilet stool plumbing noise in apartment bathroom which are generated by crossing plumbings and elbows. And it analyse the effect of noise reduction by soundproofing and insulations which are covered at crossing plumbings. And also analyse the characteristics of noise about a type of elbows, crossing plumbing and result of dB(A). At last it provide a fundamental data for the purpose of reduction of plumbing noise in apartment.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.