• 제목/요약/키워드: drain pile

검색결과 30건 처리시간 0.02초

Gravel Pile에 의한 연약지반 개량 시험시공 사례연구 (A Case Study on the Application of Gravel Pile in Soft Ground)

  • 천병식;고용일;여유현;김백영;최현석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.223-230
    • /
    • 2000
  • Sand drain as a vertical drainage is widely used in soft ground improvement. Recently, sand, the principal source of sand drain, is running out. The in-situ tests were carried out to utilize gravel as a substitute for sand. In-situ tests area was divided into two areas by material used. One is Sand Drain(SD) and Sand Compaction Pile(SCP) area, the other is Gravel Drain(GD) and Gravel Compaction Pile(GCP) area. Both areas were monitored to obtain the information on settlement, pore water pressure and bearing capacity by measuring instruments for stage loading caused by embankment. The results of measurements were analyzed, The clogging effect was checked at various depth in gravel column after the test. According to the test results, the settlement was found to be smaller in gravel drain than in sand drain. The increase in bearing capacity by gravel pile explains the result. The clogging effect was not found in gravel column. It is assumed that gravel is relatively acceptable as a drainage material. Gravel is considered to be a better material than sand for bearing capacity, and it is found that bearing capacity is larger when gravel is used as a gravel compaction pile than as a gravel drain.

  • PDF

연직배수재료로 폐콘크리트 활용에 관한 기초연구 (Utilization of Waste Concrete as Vertical Drain Material)

  • 이용수;정하익;김우성;권용완
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.571-576
    • /
    • 2001
  • This paper presents the utilization of waste concrete as vertical drain material. The materials used as vertical drain material were the waste concrete, obtained from the demolished apartments or concrete structure and sand. In this study, laboratory model test was performed to investigate settlement and bearing capacity between sand compaction pile and waste concrete compaction pile. The results of laboratory model test showed that the improvement efficiency of soft ground by waste concrete compaction pile was better than sand compaction pile.

  • PDF

인천국제공항 수직배수공법 시험시공 사례연구 (A Case Study on Test Embankment using Vertical Drain Method at Incheon International Airport)

  • 권오현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 토목섬유기술위원회 학술세미나 논문집
    • /
    • pp.33-44
    • /
    • 2001
  • The generally known vertical drain methods for improvement of soft ground are Sand Drain, Sand Compaction Pile, Plastic Drain Board, and Pack Drain. Recently, Plastic Drain Board method application in soft ground is widely used. In this case study, it is compared with each other vertical drain methods from the results of monitorning and test embankment. The results of the analysis and the study show that Plastic Drain Board method is relatively acceptable as vertical drain method.

  • PDF

연약지반에서의 쇄석골재 말뚝의 지지력 특성 연구 (A Study on the Bearing Capacity of Gravel Column in Soft Ground)

  • 천병식;여유현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.407-414
    • /
    • 1999
  • Sand drain as a vertical drainage is widely used in soft ground improvement. Recently, sand, the principal source of sand drain, is running out. A laboratory model test was carried out to utilize gravel as a substitute for sand. Though which the characteristics of gravel are compared to those of sand for engineering purpose. According to the test, the settlement was found to be smaller in gravel drain than in sand drain. The increase in bearing capacity by gravel rile explains the result. The clogging effect was not found in gravel column. As a result, it is assumed that gravel is relatively acceptable as a drainage material. Gravel material seems better than sand material in bearing capacity and it is found that bearing capacity is larger when gravel is used as compaction pile than as drain from in-situ test on bearing capacity. Increase of bearing capacity with gravel pile means an effect of composite ground by stiffness of gravel material. It can lie supposed to use gravel pile instead of sand pile in view of consolidation effect and bearing capacity.

  • PDF

Gravel Pile의 현장적용을 위한 시험시공 사례연구 (A Case Study on the Application of Gravel Pile in Soft Ground)

  • 천병식;고용일;여유현;김백영;최현석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 연약지반처리위원회 학술세미나
    • /
    • pp.32-41
    • /
    • 2000
  • Sand drain as a vertical drainage is widely used in soft ground improvement Recently, sand, the principal source of sand drain, is running out. The laboratory model tests were carried out to utilize gravel as a substitute for sand. Though which the characteristics of gravel are compared to those of sand for engineering purpose. Two cylindrical containers for the model test were filled with marine clayey soil from the west coast of Korea with a column in the center, one with sand, the other with gravel. Vibrating wire type piezometers were installed at the distance of 1.0D, 1.5D and 2.0D from the center of the column. The characteristics of consolidation were studied with data obtained from the measuring instrument place on the surface of the container. The parameter study was performed on the marine clayey soil before and after the test in order to verify the effectiveness of the improvement. The clogging effect was checked at various depth in gravel column after the test. In-situ tests area was divided into two areas by material used. One is Sand Drain(SD) and Sand Compaction Pile(SCP) area, the other is Gravel Drain(GD) and Gravel Compaction Pile(GCP) area. Both areas were monitored to obtain the information on settlement, pore water pressure and bearing capacity by measuring instruments for stage loading caused by embankment. The results of measurements were analyzed. According to the test results, the settlement was found to be smaller in gravel drain than in sand drain. The increase in bearing capacity by gravel pile explains the result. The clogging effect was not found in gravel column. It is assumed that gravel is relatively acceptable as a drainage material. Gravel is considered to be a better material than sand for bearing capacity, and it is found that bearing capacity is larger when gravel is used as a gravel compaction pile than as a gravel drain.

  • PDF

폐기물을 활용한 저투수성 오염토양의 정화 및 안정화 기술 개발 (Development of Remediation and Stabilization Technique for Low-Permeable Contaminated Soil Using Waste Materials)

  • 박상규;이기호;박준범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.681-688
    • /
    • 2002
  • Study was peformed to develop the‘environmental double pile’for the remediation of low-permeable contaminated soil. This technique is similar in function to‘sand drain pile’But this applies recyclable oyster shell treated as waste materials to a drain material and the pile is consisted of two layers. Inner metal pile is located in center and oyster shells are filled around it. By this technology, contaminated ground water is pumped out through the oyster shell and purified by drainage, adsorption, and reaction processes. Afterwards, the grout material is injected through the inner pile for the effect of the solidification / stabilization. As a result, the concept of this technique is a development of one-step process technology. Through the test, a consolidation characteristic by radial drain is going to be evaluated and the optimum standard of this technology will be calculated.

  • PDF

반응성 배수파일이 타설된 지반의 압밀거동 분석 (Analysis on Consolidation Behavior of Soft Ground with Reactive Drain Pile)

  • 김범준;오명학;윤찬영
    • 한국지반환경공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.13-23
    • /
    • 2014
  • 본 연구에서는 연약지반의 지반개량과 오염물질정화를 동시에 수행 가능한 반응성 배수파일의 적용에 대한 지반공학적 특성을 평가하였다. 반응성 배수파일의 내부 반응물질로 사용되는 제강슬래그의 적용성을 확인하였으며, 내부 반응물질을 둘러싸고 있는 원통형 차단막 길이와 차단막 외부의 외부 배수층 설치에 따른 압밀거동을 분석하였다. 이를 위하여 반응성 배수파일이 타설된 지반을 모사할 수 있는 실험장비를 개발하였으며, 외부 배수층 유 무 및 차단막 길이를 변화시켜가며, 실내모형실험을 수행하였다. 실험결과, 차단막의 길이가 짧아질수록 압밀소요시간은 감소하는 것으로 나타났지만, 차단막 길이변화에 따른 압밀소요시간차이에 비해 외부 배수층 유 무에 따른 압밀소요시간의 차이가 더 큰 것으로 나타났다.

강널말뚝으로 보강된 점토지반거동의 수치해석 (Numerical Analysis on the Behavior of Clayey Foundation Reinforced with Steel Sheet Pile)

  • 양극영;이대재;정진섭
    • 한국농공학회지
    • /
    • 제44권1호
    • /
    • pp.142-154
    • /
    • 2002
  • This study was performed to investigate constraint effects of deformation (heaving, lateral displacement) of clayey foundation reinforced with sheet pile at the tip of banking on soft ground, under intact state (natural) and the state of vertical drain respectively. The following results are obtained. 1. In view of reduction in heaving or lateral displacement, sheet pile is not supposed to be of use. 2. Sheet pile is effective only when vertical drain is installed for acceleration of consolidation and gradual loading is applied.

말합연약식반의 변형위석에 관한 수치해석 (Numerical Analysis on Deformation of Soft Clays Reinforced with Rigid Materials)

  • 강병선;박병기;정진섭
    • 한국지반공학회지:지반
    • /
    • 제1권2호
    • /
    • pp.27-40
    • /
    • 1985
  • 본고는 기약지반변형해석에 이용될 범용 program을 개발하고 이를 이용하여 성토부끝에 sheet pile을 타설하거나 혹은 성토부아래의 연약정토지반을 개취하였을 때의 변형억제효과를 연구한 것이다. 본고에 적용된 압밀리론으로서 Biot의 압밀방정식과 구성방정식으로서 탄소성리론에 근거한 modified Cam-clay 이론을 적용하였고 유한요소해석으로서는 Christian-Boehmer계를 도입하여 program화한 것이다. 그 주요한 결론은 다음과 같다. 1. 속변지반의 침하효과에 관해서는 sheet pile이나 심우혼합처새깊이를 자지층까지 관입하여 시공하고 그 자신의 침하가 없을 경우에만 유효하다. 2. 흔히 사용되는 sheet pile대책공법은 통상의 steel sheet pile의 각성으로서는 성토직후의 봉기, 측방변위의 억제효과는 기대할 수 없다. 3. Sheet pile에 대한 예상론인 사용방법은 성토하부에 세밀을 촉진하기 위해 vertical drain을 설치하고 점증재하 방법만이 확실한 효과가 있다. 4. 체층혼합처리공법은 예상한 바와 같이 그 자종가 강성이 클수록 침하억제핵과가 있다. 특히 grouting을 통한 지반강화가 곧장 주변지반의 변형억제효과가 있다고 단정하는 것은 그 강성 까 관련하여 신중히 고려하여 결정해야 한다.

  • PDF

해성 점토지반의 저회다짐말뚝 보강 효과에 관한 실험적 연구 (An Experimental Study on the Effects of Bottom Ash Compaction Pile in the Sea Clay Layer)

  • 박세현;한윤수;도종남;천병식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.595-598
    • /
    • 2010
  • Many economical and efficient methods such as sand drain method(SD), plastic board drain(PBD), sand compaction pile, vacuum consolidation method, etc., have been used for soft grounds. The case of sand compaction pile has an effect on accelerating consolidation and increasing bearing capacity by penetration at regular intervals under soft grounds for reducing the drainage path. But, this method has caused not only the nature damage by extracting the sands indiscreetly but also the economical problem for importing the sands because it needs so much sand to make the sand compaction pile. Thus, this study choosed the bottom ash which has similar engineering characteristics with sand. It was performed that clogging test and large direct shear test changing the bottom ash replacement ratio in soft ground for studying strength characteristics of soft ground using bottom ash compaction pile. As a result of the test, the internal friction angle was largely increased and the cohesion was decreased as the replacement ratio increased.

  • PDF