• Title/Summary/Keyword: double-sided

Search Result 231, Processing Time 0.034 seconds

A study on the 2-dimensional flux distribution analysis of a double sided linear induction machine wi th a short primary type (단 1차형 양측식 선형 유도 전동기의 2차원 자속 분포 해석에 관한 연구)

  • Lim, D.H.;Cho, Y.H.;Kim, D.J.
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.333-336
    • /
    • 1988
  • This paper is presented the two dimensional flux distribution analysis of a double sided linear induction moter with the end effects and the transeverse edge effects, which is caused by the finite length and width of the stator iron. The results are expected to be used to increased the understanding of DLIM characteristics and design

  • PDF

Double Aortic Arch with Right Sided Descending Aorta - Report of 1 case - (우측 하행 대동맥을 동반한 중복 대동맥궁 - 1례 수술 치험 -)

  • 조경수
    • Journal of Chest Surgery
    • /
    • v.23 no.1
    • /
    • pp.201-204
    • /
    • 1990
  • The double aortic arch is the commonest anomaly among the vascular rings are relatively rare congenital vascular anomalies. This anomaly is malformation of the aortic arch system may, by compression of the trachea and esophagus, cause respiratory distress and dysphagia. We experienced one case of double aortic arch with right sided descending aorta with predominant right anterior arch treated surgically at Kyung Hee University Medical Center. 1-year-old male patient with acute airway obstruction due to combination of double aortic arch and right descending aorta. The diagnosis was made by simple X-ray & confirmed by barium esophagogram & aortogram. The operative approach was through left thoracotomy & underwent division of the left aortic arch & division of ligamentum arteriosum & suspension of divided proximal end of anterior arch to anterior thoracic wall. The postoperative courses was uneventful and doing well on the 3 years.

  • PDF

The Design of DRAM Memory Modules in the Fabrication by the MCM-L Technique (DRAM 메모리 모듈 제작에서 MCM-L 구조에 의한 설계)

  • Jee, Yong;Park, Tae-Byung
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.5
    • /
    • pp.737-748
    • /
    • 1995
  • In this paper, we studyed the variables in the design of multichip memory modules with 4M$\times$1bit DRAM chips to construct high capacity and high speed memory modules. The configuration of the module was 8 bit, 16 bit, and 32 bit DRAM modules with employing 0.6 W, 70 nsec 4M$\times$1 bit DRAM chips. We optimized routing area and wiring density by performing the routing experiment with the variables of the chip allocation, module I/O terminal, the number of wiring, and the number of mounting side of the chips. The multichip module was designed to be able to accept MCM-L techiques and low cost PCB materials. The module routing experiment showed that it was an efficient way to align chip I/O terminals and module I/O terminals in parallel when mounting bare chips, and in perpendicular when mounting packaged chips, to set module I/O terminals in two sides, to use double sided substrates, and to allocate chips in a row. The efficient number of wiring layer was 4 layers when designing single sided bare chip mounting modules and 6 layers when constructing double sided bare chip mounting modules whereas the number of wiring layer was 3 layers when using single sided packaged chip mounting substrates and 5 layers when constructing double sided packaged chip mounting substrates. The most efficient configuration was to mount bare chips on doubled substrates and also to increase the number of mounting chips. The fabrication of memory multichip module showed that the modules with bare chips can be reduced to a half in volume and one third in weight comparing to the module with packaged chips. The signal propagation delay time on module substrate was reduced to 0.5-1 nsec.

  • PDF

Thermo-mechanical Deformation Analysis of Filu Chip PBGA Packages Subjected to Temperature Change (Flip Chip PBGA 패키지의 온도변화에 대한 변형거동 해석)

  • Joo, Jin-Won;Kim, Do-Hyung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.4
    • /
    • pp.17-25
    • /
    • 2006
  • Thermo-mechanical behavior of flip-chip plastic ball grid array (FC-PBGA) packages are characterized by high sensitive $moir\'{e}$ interferometry. $Moir\'{e}$ fringe patterns are recorded and analyzed for several temperatures. Deformation analysis of bending displacements of the packages and average strains in the solder balls for both single and double-sided package assemblies are presented. The bending displacement of the double-sided package assembly is smaller than that of the single-sided one because of its symmetric structure. The largest effective strain occurred at the solder ball located on the edge of the chip and its magnitude of the double-sided package assembly is greater than that of single-sided one by 50%.

  • PDF

Double-Outlet of Left Ventricle in Corrected Transposition of Great Arteries -One case report- (좌심실 이중유출로를 동반한 교정형 대혈관전위증 -1예보고-)

  • 권중혁
    • Journal of Chest Surgery
    • /
    • v.12 no.2
    • /
    • pp.119-126
    • /
    • 1979
  • This is one case report of the extremely rare congenital cardiac malformation, Double-outlet of left ventricle in corrected transposition of great arteries. 11-year-old boy complained acrocyanosis and exertional dyspnea, the parents noticed cyanosis since birth. Physical examination revealed acrocyanosis, clubbed fingers and toes, G-III pansystolic murmur on 2nd and 3rd ICS, LSB. Right heart catheterization revealed significant $O_2$ jump in ventricular level. Right and left ventriculography showed the both catheters arriving in the same ventricle i.e. anterior chamber, morphological left ventricle was in right and anterior position, simultaneous visualization of aorta and pulmonary artery and aorta locating anterior and right side of pulmonary artery. Echo cardiogram surely disclosed interventricular septum. Conclusively it was clarified that the patient has Double-outlet of left ventricle and corrected transposition of great arteries [S.L.D.]. Operation was performed to correct the anomalies under extracorporeal circulation with intermittent moderate hypothermia. Right-sided ventriculotomy disclosed the following findings. 1. Right-sided ventricle was morphological left ventricle. 2. Left-sided ventricle was morphological right ventricle. 3. Right side atrioventricular valve was bicuspid. 4. Left side atrioventricular valve was tricuspid. 5. Aortic valve was superior, anterior and right side of pulmonary valve. 6. Subpulmonary membranous stenosis. 7. Non-committed ventricular septal defect. We made a tunnel between VSD and aorta with Teflon patch so that arterial blood comes through VSD and the tunnel into aorta. After correction the patient needed assisted circulation for 135 min. to have adequate blood pressure. Postoperatively by any means, adequate blood pressure could not be maintained and expired in the evening of operation day.

  • PDF

An Electric-Field Coupled Power Transfer System with a Double-sided LC Network

  • Xie, Shi-Yun;Su, Yu-Gang;Zhou, Wei;Zhao, Yu-Ming;Dai, Xin
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.289-299
    • /
    • 2018
  • Electric-field coupled power transfer (ECPT) systems employ a high frequency electric field as an energy medium to transfer power wirelessly. Existing ECPT systems have made great progress in terms of increasing the transfer distance. However, the topologies of these systems are complex, and the transfer characteristics are very sensitive to variations in the circuit parameters. This paper proposes an ECPT system with a double-sided LC network, which employs a parallel LC network on the primary side and a series LC network on the secondary side. With the same transfer distance and output power, the proposed system is simpler and less sensitive than existing systems. The expression of the optimal driving voltage for the coupling structure and the characteristics of the LC networks are also analyzed, including the transfer efficiency, parameter sensitivity and total harmonic distortion. Then, a design method for the system parameters is provided according to these characteristics. Simulations and experiments have been carried out to verify the system properties and the design method.

Comparative Study of Armature Reaction Field Analysis for Tubular Linear Machine with Axially Magnetized Single-sided and Double-sided Permanent Magnet Based on Analytical Field Calculations

  • Shin, Kyung-Hun;Park, Min-Gyu;Cho, Han-Wook;Choi, Jang-Young
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.79-85
    • /
    • 2015
  • This paper presents a comparative study of a Tubular Linear Machine (TLM) with an Axially Magnetized Single-sided Permanent Magnet (AMSPM) and an Axially Magnetized Double-sided Permanent Magnet (AMDPM) based on analytical field calculations. Using a two-dimensional (2-D) polar coordinate system and a magnetic vector potential, analytical solutions for the flux density produced by the stator windings are derived. This technique is significant for the design and control implementation of electromagnetic machines. The field solution is obtained by solving Maxwell's equations in the simplified boundary value problem consisting of the air gap and coil. These analytical solutions are then used to estimate the self and mutual inductances. Two different types of machine are used to verify the validity of these model simplifications, and the analytical results are compared to results obtained using the finite element method (FEM) and experimental measurement.

Surgical Techniques of Right Lung Transplantation in Dogs (황견에서 우측폐 이식수술기에 관한 실험적 연구)

  • 이두연
    • Journal of Chest Surgery
    • /
    • v.22 no.3
    • /
    • pp.416-424
    • /
    • 1989
  • We have performed eight, single transplantations of right lung in dogs from September, 1988 to March 1989 at the Thoracic & Cardiovascular Surgical department, Yonsei University, College of Medicine, Seoul, Korea. We wrapped bronchial anastomosis site with great omentum and used cyclosporin in preoperative and postoperative periods in seven cases except one. The one without wrapping the bronchial anastomotic site with omentum and using cyclosporin died due to bronchial anastomotic site rupture in postoperative fourth day. If there is no reason to choose one side over the other, we would generally choose to do left-sided transplant as this is technically somewhat easier because of the long length of recipient bronchus and the ease of clamping the left atrium proximal to the pulmonary veins. The right atrium limits the amount of left atrium that can have incorporated into the clamp proximal to the pulmonary veins on the right side. But we had chosen to do right-sided transplant of lung because we must take variable technical experiences on right sided lung transplant in dogs. We have to anastomose one of pulmonary vein and left atrial wall on right-sided transplant easily only with double ligation of one pulmonary vein because right atrium limited the clamp of left atrium proximal to pulmonary veins with decreased venous return and cardiac output in some dogs. All seven dogs with right-sided lung transplant had survived more than one day with good condition except one. The one dog have to be sacrificed to evaluate the difference between the gas analysis in pulmonary venous and arterial blood in post-operative eight hours. We found hemorrhagic pulmonary edematous changes of contralateral left lung in this dog. And also all dogs have to be sacrificed for the evaluation of surgical problems, anytime in post-operative periods without any cardiopulmonary resuscitative efforts when the general condition would be worse progressively. We found no any surgical technical errors in seven dogs except one with thrombi in suture site of left atrium. There were hemorrhagic pulmonary edematous changes of transplanted right lung in one, of contralateral left lung in one, of contralateral left lung with double ligation of its pulmonary artery in one, thrombi around left atrial sutures sites in one, multiple air leakage in one bronchial rupture in one due to rejection or infection. There were accidental extubation and delayed intubation in one and unknown cause of death in one.

  • PDF

EVALUATION ON THE FATIGUE STRENGTH OF SINGLE-SIDED WELDED JOINTS WITH CERAMIC BACKING MATERIAL

  • Kim Gwang-Seok;Kim Yu-Il;Jeon Yu-Cheol;Gang Jung-Gyu;Heo Ju-Ho;Lee Seong-Geun
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.255-257
    • /
    • 2004
  • This report presents S-N testing results of the butt and T-joint weldment which are produced by single sided welding with cenramic backing material. The specimen is designed in accordance with JISZ 3103 aid the test is peformed by the JSME S002. The nominal and hot spot stress based design S-N curves derived from fatigue tests are compared with the BS design curve. For butt and T-joint, it can be known that the double-sided butt welding process could be replaced by the single sided butt welding.

  • PDF

3-D fracture analysis of cracked aluminum plates repaired with single and double composite patches using XFEM

  • Jamal-Omidi, Majid;Falah, Mehdi;Taherifar, Davood
    • Structural Engineering and Mechanics
    • /
    • v.50 no.4
    • /
    • pp.525-539
    • /
    • 2014
  • Bonded composite-patch repair has been widely used to restore or extend the service life of damaged structures due to its effectiveness as a mechanical repair technique. In this paper using extended finite element method (XFEM), three-dimensional crack models are developed to examine the fracture behavior of centrally cracked aluminum plates repaired with single and double sided composite patches. Stress intensity factor (SIF) at the crack tip is used as the fracture criterion. In this regard, the effects of the crack lengths, patch materials, orientation of plies, adhesive and patch thickness are examined to estimate the SIF of the repaired plate and the repair performance. The obtained results show that composite patches have significant effect on reduction of the SIF at the crack tip. It is also proved that using double symmetric repair, in comparison to single one, reduces considerably SIF at the crack tip. Hence, the residual strength can be improved significantly as well as fatigue life of the structure. Investigation of ply orientation effects shows SIF increase as the ply orientation is changed from $0^{\circ}$ (perpendicular to the advancing crack) to $90^{\circ}$ (parallel to the crack line). However, the effectiveness of the ply orientation depends on the loading direction and the crack direction.