• Title/Summary/Keyword: double-low

Search Result 1,666, Processing Time 0.031 seconds

Development of two-component polyurethane metering system for in-mold coating (인몰드 코팅을 위한 2액형 폴리우레탄 공급장치 개발)

  • Seo, Bong-Hyun;Lee, Ho-Sang
    • Design & Manufacturing
    • /
    • v.10 no.2
    • /
    • pp.18-23
    • /
    • 2016
  • Injection molded thermoplastic parts may need to be coated to facilitate paint adhesion, or to satisfy other surface property requirements, such as appearance, durability, and weather resistance. In this paper, a two-component polyurethane metering system was developed for the simultaneous injection and surface coating of a plastic substrate. The system was composed of storage tanks, feed pumps, axial piston pumps, mixing head. The tank was designed to be double-jacket structured and fabricated for polyol and isocyanate, respectively. A temperature chamber was used to maintain the material temperature to be $80^{\circ}C$ during flowing from storage tank to mixing head. Inside the chamber, feed pump, low pressure filter, high pressure pump, high pressure filter, pressure sensor, flow meter were installed. A mixing head of L-type was used for homogeneous mixing of polyol and isocyanate. Inside the mixing head, a cartridge heater and a temperature sensor were installed to control the temperature of the materials. The flow rate of axial-piston pump was controlled by using closed-loop feedback control algorithm. The input flow-rates were compared with the measured values. The output error was 6.7% for open-loop control, whereas the error was below 2.2% for closed-loop control. In addition, the pressure generated through mixing-head nozzle increased with increasing flow rate. It was found that the pressure drop between metering pump and mixing-head nozzle was almost 10 bar.

Available Organic Carbon Controls Nitrification and Immobilization of Ammonium in an Acid Loam-Textured Soil

  • Choi, Woo-Jung;Lee, Sang-Mo;Han, Gwang-Hyun;Yoon, Kwang-Sik;Jung, Jae-Woon;Lim, Sang-Sun;Kwak, Jin-Hyeob
    • Journal of Applied Biological Chemistry
    • /
    • v.49 no.1
    • /
    • pp.28-32
    • /
    • 2006
  • Effect of organic-C on immobilization and nitrification patterns in acidic soil was examined during 20 weeks incubation period to verify if organic amendments such as composted material can increase soil retention of N by stimulating microbial immobilization of $NH_4^+$. Four treatments were laid out: control without fertilizer N and glucose (treatment code: S), ammonium sulfate (SN), ammonium sulfate with single glucose at the commencement (0 week) of incubation (SNG), and ammonium sulfate with double glucose at 0 and 4 weeks of incubation (SNGG). Glucose application (SNG) significantly increased microbial immobilization of $NH_4^+$ within 1 week of incubation over SN. Immobilization was followed by remineralization thereafter; however, second-application of glucose (SNGG) restored $NH_4^+$ immobilization. At the same time, nitrification was significantly inhibited by glucose application as indicated by consistently low $NO_3^-$ concentration in SNG and SNGG soils, suggesting that microbial assimilation of $NH_4^+$ is predominant compared to nitrification when available C-source is abundant. These results suggest application of chemical fertilizer-N with organic amendment would have beneficial effect on soil-N retention and environmental conservation by reducing production of $NO_3^-$ which is likely to be lost through leaching or denitrification.

Inrush Current Control of Matching Transformer for Dynamic Voltage Restorer (동적전압보상기를 위한 정합 변압기의 돌입전류 제어)

  • Seo, Il-Dong;Jeon, Hee-Jong;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.340-348
    • /
    • 2006
  • This paper proposes an inrush current control technique of matching transformer for configuration of dynamic voltage restorer(DVR). The DVR system consist of PWM inverter to inject arbitrary voltage, LC low pass filter as harmonic eliminator and matching transformer for isolation. However, the matching transformer has an excess of inrush current by magnetic flux saturation in the core. Due to this inrush current, the rating of matching transformers is double for needed nominal rating for protection of DVR. Therefore, in this paper, the modeling method of magnetic flux saturation is used to analyze a magnitude of inrush current, and additional current controller is used for PWM inverter output regulation. Simulation and experimental results are provided to demonstrate the validity of the proposed control method.

Performance Characteristics of Vehicle Air Conditioning System Using Internal Heat Exchanger with Inner Fin (휜 타입 내부열교환기 적용에 따른 차량용 냉방시스템 성능 특성)

  • Kim, Sung Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.69-73
    • /
    • 2013
  • Internal heat exchanger (IHX) apparatus using the temperature difference between high and low pressure lines in vehicle air conditioning system is a good method to enhance the cooling performance. In this study, we designed various double-pipe internal heat exchangers which have inner fins between the internal pipe and external pipe. We also measured the performance characteristic (pressure drop, cooling capacity, compressor work and coefficient of performance (COP)) of the modified internal heat exchangers that had the change of the fin height and the inside shape of the internal pipe. This experimental results indicated that the liner and serration type internal heat exchanger was the best cooling performance. In addition, the air conditioning system with the liner and serration type internal heat exchanger showed the improved performances of about 6.4% and 9.2%, respectively, for the cooling capacity and COP.

Low-k plasma polymerized cyclohexan: single layrer and double layer

  • 최자영;권영춘;여상학;정동근
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.74-74
    • /
    • 2000
  • 낮은 유전상수(k$\leq$3)와 높은 열적안정성(>4$25^{\circ}C$)은 초고집적회로(ULSI)기술에서 RC 지연을 해결하기 위한 금속배선의 중간 절연층으로서의 2개의 가장 중요한 특성이다. 본 연구에서는 cyclohezane을 precursor로 사용하여 plasma enhanced chemical vapor deposition(PECVD)방법으로 유기박막을 성장시켰으며 낮은 유전상수와 높은 열적안정성을 동시에 확보하기 위하여 열적안정성은 좋지 않지만 유전상수가 낮은 박막(soft layer)위에 유전상수는 다소 높지만 열적안정성이 좋은 박막(hard layer)을 얇게 증착하여 hard layer/soft layer의 2층 구조를 형성하여서 구조적, 전기적 특성을 조사하였다. 유기박막은 5$0^{\circ}C$로 유지된 reactor 내부에서 argon(Ar) plasma에 의해 증착되었으며 platinum(Pt)기판과 silicon 기판위에 동시에 증착하였다. Pt 기판위에 증착한 시편으로 유전상수, I-V 등 전기적 특성을 측정하였고, silicon 기판위에 증착한 시편으로 열적안정성과 구조적 특성등을 분석하였다. 증착압력 0.2Torr에서 plasma power를 5W에서90W로 증가할 때 유전상수는 2.36에서 3.39로 증가하였으며 열적안정성은 90W에서 180W로 증가하였을 때 유전상수는 2.42에서 2.79로 증가하엿고 열적안정성은 모두30$0^{\circ}C$이하였다. 단일층 구조에서는 유전상수가 낮은 박막은 열적으로 불안정하고 열적 안정성이 좋은 박막은 유전상수가 다소 높은 문제가 나타났다. 이런 문제를 해결하기 위하여 2 Torr, 120W에서 증착한 유전상수가 2.55이고 열적으로 불안정한 박막을 soft layer로 5150 증착하고 그 위에 0.2Torr, 90W에서 증착한 유전상수가 3.39이고 열적으로 45$0^{\circ}C$까지 안정한 박막을 hard layer로 360 , 720 , 1440 증착하였다. 증착된 2층구조 박막의 유전상수는 각각 2.62, 2.68, 2.79이었으며 열적안정성 측정에서는 40$0^{\circ}C$까지 두께 감소가 보이지 않았다. 그러나 SEM 측정에서 열처리 후 표면이 거칠어지는 현상이 발견되었다.

  • PDF

Effect of Amine-Based Antioxidants as Stabilizers for Biodiesel (바이오디젤용 산화방지제인 아민안정제들의 효과)

  • Park, Soo-Youl;Kim, Hun-Soo;Kim, Seung-Hoi
    • Tribology and Lubricants
    • /
    • v.31 no.6
    • /
    • pp.258-263
    • /
    • 2015
  • Biodiesel is an environmentally-friendly fuel with low smoke emission because it contains about 10% oxygen. Biodiesel fuel prepared by transesterification of vegetable oil or animal fats is susceptible to auto-oxidation. The rate of auto-oxidation depends on the number of methylene double bonds contained within the fatty acid methyl or ethyl ester groups. Biodiesel may be easily oxidized under several conditions, i.e., upon exposure to sunlight, temperature, oxygen environment. Maintenance of the fuel quality of biodiesel requires the development of technologies to increase the resistance of biodiesel to oxidation. Treatment with antioxidants is a promising approach for extending the shelf-life or storage time of biodiesel. The chemical properties of various amine-based antioxidants were evaluated after synthesis of the antioxidants by condensation of phenylenediamine with alkylamines at room temperature. In general, the oxidative stability can be assessed based on various experimental parameters. Such parameters may include temperature, pressure, and the flow rate of air through the samples. The Rancimat method (EN14112) was selected because it is a rapid technique that requires very little sample and provides good precision for oxidative degradation analysis. Specifically, the EN 14112 technique provides enhanced efficiency for oxidative stability evaluation when a larger ester head group is utilized. Therefore, this technique was employed for evaluation of the oxidation stability of biodiesel by the Rancimat method (EN14112).

Improvement of Tunnelling Speed in Full-Face Mechanical Excavation (기계굴착에서 굴착속도의 발전경향분석)

  • Park, Chul-Whan;Park, Chan;Cheon, Dae-Sung;Synn, Joong-Ho
    • Tunnel and Underground Space
    • /
    • v.17 no.3 s.68
    • /
    • pp.225-233
    • /
    • 2007
  • Because of Norwegian topography as valleys and fjords, a large number of tunnels has been built and 59 of them have been excavated by TBM for last 30 years. Prognosis technology has been developed and improved through lots of TBM experiences, and the NTNU prediction model has been completed. This paper focuses the improvement of net penetration rate and advance rate in 14 Norwegian and 4 Koran TBM tunnelling sites of which data were reported. Through this period, net penetration rate as well as advance rate were increased to double with the improvement of disc cutter size and cutter arrangement in Norway. These rates in Korea were also increased for 15 years even though the rates were lower compared to Norwegian. It is estimated that these low rates were mainly caused by using disc cutters less than 17 inch diameter. It is expected that net penetration rate and advance rate can be increased by improvement of machine and tunnelling technology, especially by using 17 or 19 inch of the disc cutter size in the Korean full face mechanical tunnelling site.

House Dust Mite Allergens in Domestic Homes in Cheonan, Korea

  • Nam, Hae-Seon;Siebers, Robert;Lee, Sun-Hwa;Park, Joon-Soo;Kim, Yong-Bae;Choi, Young-Jin;Lee, Sang-Han;Crane, Julian
    • Parasites, Hosts and Diseases
    • /
    • v.46 no.3
    • /
    • pp.187-189
    • /
    • 2008
  • House dust mites produce inhalant allergens of importance to allergic patients, We measured the major group 1 allergens, Der p 1 and Der f 1, from the house dust mites Dermatophagoides pteronyssinus and Dermatophagoides farina, respectively in 100 randomly selected domestic homes from Cheonan, Korea, Dust samples were collected by vacuuming from the living room floor and 1 mattress in each home, Der p 1 and Der f 1 were measured by double mono-clonal ELISA. Der p 1 levels were very low, with geometric mean levels for floors and mattresses being $0.11\;{\mu}g/g$ (range: 0.01-4.05) and $0.14\;{\mu}g/g$ (range: 0.01-30.0), respectively. Corresponding levels of Der f 1 were higher, $7.46\;{\mu}g/g$ (range: 0.01-262.9) and $10.2\;{\mu}g/g$ (range: 0.01-230.9) for floors and mattresses, respectively. D. farinae appears to be the dominant house dust mite in Cheonan.

Survey on the Incidence of Homeless Pulmonary Tuberculosis Infection Rate through Chest X-ray Examination (흉부 X-선 검사를 통한 노숙인 폐결핵 감염률 현황조사)

  • Kim, Mi-Young;Shin, Sung-Rae;Ryu, Young-Hwan;Lim, Hwan-Yeal
    • Journal of Radiation Industry
    • /
    • v.10 no.4
    • /
    • pp.249-255
    • /
    • 2016
  • This study, Seoul City shelter, you are trying to seek medical cooperation and cure rate increase proposal Yu findings's current situation and tuberculosis of homeless tuberculosis. Inspector, and has a total 591 people is targeted to implement an interview after acquiring utilization agreement in studies conducted chest X-ray photography. Of the interview questions, three or more protons, it is determined that the TB symptomatic conducted sputum examination, chest X-ray examination confirms the physician radiology, when sputum examination primarily chromatic findings the double implemented and conducted by requesting the ship inspection also said inspection sputum acid-fast bacteria if it is true one, respectively. confirmed case result of checking whether there is a difference due to risk factors(Jb) at the chi square black, it was found that there is no statistically significant difference at 95% confidence level. (${\chi}^2=0.276$, p>0.05), suspected case (Ac, Ae) results of examining whether there is a difference due to risk factors in chi square black, that there is a statistically significant difference at 99% confidence level is I found (${\chi}^2=9.414$, p<0.01). The nature of the homeless tuberculosis screening and directed to the distance homeless specific location are likely to evaluate the actual incidence low and aggressive or management needs, the rationale is allowed insufficient reality is. Through this research, future, for tuberculosis high risk tuberculosis patient, such as homeless to expand the tuberculosis screening of infectious tuberculosis patients in private medical institutions, and one-stop service that chest X-ray examination and sputum examination is carried out at the same time introduced immediately to prevent the inspection and examination, cure, and should establish a foundation that can be up to post administration.

Effects of Permalloy Multilayered Schemes and CoZrNb Intermediate Layer on Recording Characteristics of CoCr/NiFe Media (Permalloy 다층화와 CoZrNb 중간층이 CoCr/NiFe 매체의 기록특성에 미치는 영향)

  • 장평우;이택동;박관수
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.1
    • /
    • pp.20-24
    • /
    • 1994
  • The read/write characteristics of CoCr/NiFe double layered media are strongly affected by the magnetic properties of NiFe magnetic soft layer as well as those of CoCr recording layer. Modification of the permalloy layer by NiFe/Ge multilayer scheme resulted in the higher recording sensitivity and the higher reproduced voltage of CoCr/NiFe medium and this is attributed to the higher permeability of the back layer and high perpendicular anisotropy of the CoCr recording layer. Although higher permeability of back layer results in higher recording sensitivity, the increment of the reproduced voltage was not remarkable, which can be confirmed in the FEM numerical analysis. On the contrary, peak shift characteristics of the CoCr/NiFe medium with the NiFe multi back layer was deteriorated compared to that of the CoCr/NiFe medium with NiFe single back layer. Insertion of ferromagnetic thin CoZrNb intermediate layer between CoCr and NiFe layer was effective to ensure large reproduced voltage and low peak shift. These recoridng characteristics were also discussed in connection with microstructural characteristics.

  • PDF