• Title/Summary/Keyword: double cross type

Search Result 102, Processing Time 0.026 seconds

Structural Behavior of the RC Column-Steel Beam Joint with Band Plate (Band Plate로 연결된 RC기둥-철골보 접합부의 이력거동에 관한 실험연구)

  • Seo, S.Y.;Yi, W.H.;Lee, L.H.;Yoon, S.J.
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.1
    • /
    • pp.213-221
    • /
    • 2002
  • This paper presents the experimental result of Reinforced Concrete column-steel beam joint connected by Band Plates(BP). Main parameters in the test are the shape of BP and thickness of plate. Ten interior and exterior RC column-steel beam joint specimens are designed. Cyclic loads are applied to the beam end of eight specimens (four interior specimens and four exterior specimens). To evaluate the cyclic effect, monotonic loads are acted for two specimens. All specimen showed similar failure pattern such as the plate of BP get torn after the large deformation. Even though the specimen with double cross type BP has lower strength than the specimen with single cross type BP, the energy dissipation capacity of the specimen turned out high. Thus, provided the strength of joint with double cross type to be designed to have suitable strength by increasing the thickness of plate, the joint system may show higher seismic capacity.

Double Outlet of Right Ventricle in Criss-Cross Heart -Surgical Experience of One Case (십자형심장에 동반된 양대혈관우심실기시증 -수술치험 1례)

  • Kim, Dae-Yeon;Jo, Seong-Rae;Park, Seong-Dal;Jeong, Hyeon-Gi
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1242-1246
    • /
    • 1997
  • Criss-cross heart which is a cardiac malformation caused by abnormal rotation of the ventricles early in embryonic development, is rare but a double outlet of right ventricle in priss-cross heart is very rare. We experienced a case of criss-cross heart which is situs solidus, concordant atrioventricular connection and double outlet of rig t ventricle with remote ventricular septal defect of perimembranous inlet type. A 4-years old female was diagnosed as a double outlet of right ventricle in criss-cross heart after echocardiography, cardiac catheterization and cardiac angiography. The surgical correction was a intraventricular reconstruction of left ventricular outflow with 314 circle of 20 mm Hemashield vascular graft from the ventricular septal defect to the aorta. The patient had a temporary atrioventricular block but was recovered uneventfully, and a postoperative echocardiogram showed no left ventricular outflow obstruction, no intracardiac shunt.

  • PDF

Analysis of Hybrid ARQ System Using Cross Layer (Cross Layer를 이용한 Hybrid ARQ System 분석)

  • Park, Tae-Doo;Kim, Min-Hyuk;Kim, Chul-Seong;Jung, Ji-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.11
    • /
    • pp.1229-1234
    • /
    • 2010
  • High quality and high speed multimedia services will be required in the next generation mobile communications. To satisfy these services, powerful error correction techniques are used. ARQ(Auto Repeat Request) techniques, aspects of the throughput, and FEC(Forward Error Correct) techniques have disadvantages in terms of reliability. H-ARQ(Hybrid Auto Repeat Request) systems have been studied extensively as a solution of these disadvantages. In this paper introduce double layer coding and H-ARQ type, proposed H-ARQ system using double layer coding methods. Simulate BER performance and throughput. And we suggest that according to channel condition suitable H-ARQ type.

Investigation of FIV Characteristics on a Coaxial Double-tube Structure (동심축 이중관 구조에서 유동기인진동 특성 고찰)

  • Song, Kee-Nam;Kim, Yong-Wan;Park, Sang-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.10
    • /
    • pp.1108-1118
    • /
    • 2009
  • A Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source of the order of $950^{\circ}C$ for nuclear hydrogen generation, which can produce hydrogen from water or natural gas. A primary hot gas duct (HGD) as a coaxial double-tube type cross vessel is a key component connecting a reactor pressure vessel and an intermediate heat exchanger in the VHTR. In this study, a structural sizing methodology for the primary HGD of the VHTR is suggested in order to modulate a flow-induced vibration (FIV). And as an example, a structural sizing of the horizontal HGD with a coaxial double-tube structure was carried out using the suggested method. These activities include a decision of the geometric dimensions, a selection of the material, and an evaluation of the strength of the coaxial double-tube type cross vessel components. Also in order to compare the FIV characteristics of the proposed design cases, a fluid-structure interaction (FSI) analysis was carried out using the ADINA code.

Preliminary Investigations of a Double Deck Train(EMU type) System (EMU type 2층열차 차량시스템에 관한 기초연구)

  • Kim Hyeongjin;Hwang Wonju;Hur Hyunmoo;Park Kwangbok
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.412-417
    • /
    • 2003
  • In recent years, efficient commuter transportation has become one of major issues to be taken into account around Seoul metropolitan area. In oder to solve the problems, several countries such as Japan, France and so on gradually operate double deck trains as efficient, reliable and comfortable mass transportation systems. However, the double deck trains have relatively big cross sectional areas and high mass centers that cause unsafe vehicle running performances and interface problems between the vehicles and infrastructures, and do not have enough spaces for electric equipments. Therefore, prior to operate double deck trains on the existing lines in Korea, careful investigations should be performed. For these reasons, we have studied the double deck train system for the existing lines around Seoul metropolitan area as an alternative way to carry heavy transportation efficiently and comfortably.

  • PDF

The study on interval calculation of cross passage in undersea tunnel by quantitative risk assesment method (해저철도터널(목포-제주간) 화재시 정량적 위험도 평가기법에 의한 피난연결통로 적정간격산정에 관한 연구)

  • Yoo, Ji-Oh;Kim, Jin-Su;Rie, Dong-Ho;Shin, Hyun-Jun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.249-256
    • /
    • 2015
  • Quantitative Mokpo-Jeju undersea tunnel is currently on the basis plan for reviewing validation. As for the cross section shape for express boat of 105 km line, sing track two tube is being reviewed as the Euro tunnel equipped with service tunnel. Also, 10 carriage trains have been planned to operate 76 times for one way a day. So, in this study, quantitative risk assessment method is settled, which is intended to review the optimal space between evacuation connection hall of tunnel by quantitative risk analysis method. In addition to this, optimal evacuation connection hall space is calculated by the types of cross section, which are Type 3 (double track single tube), Type 1 (sing track two tube), and Type 2 (separating double track on tube with partition). As a result, cross section of Type 2 is most efficient for securing evacuation safety, and the evacuation connection space is required for 350 m in Type 1, 400 m in Type 2, and 1,500 m in Type3 to satisfy current domestic social risk assessment standard.

Enzyme-Linked Immunosorbent Assay (ELISA) for Detection of Clostridium botulinum Type F Toxin (Clostridium botulinum Type F Toxin의 면역학적 효소방법에 의한 검출에 관한 연구)

  • Lee, Jeong-Kug;K. H. Yang
    • Microbiology and Biotechnology Letters
    • /
    • v.10 no.3
    • /
    • pp.205-209
    • /
    • 1982
  • The enzyme-linked immunosorbent assay using the so-called "double-sandwich"technique was applied to determine Clostridium botulinum type F toxin. Polystyrene tubes were coated with horse anti-type F toxin serum and then toxin sample was added. The tubes were subsequently treated with rabbit anti-type F toxin IgG and sheep anti-rabbit serum IgG-horseradish peroxidase conjugate. By this technique, about 10 mouse intraperitoneal 50% lethal doses (ip LD/50/) of type F toxin could be detected. Low back-ground reading was achieved with the use of phosphate-buffered saline containing 0.05% Tween 20 and 1% bovine serum albumin as diluents of rabbit IgG and conjugate. Addition of EDTA in the diluents of toxin increased ELISA extinction value significantly. No cross-reaction was observed with botulinum type A and B toxin, but type E toxin gave sleight cross-reaction.

  • PDF

Suggestion of Structural Sizing Methodology on a Coaxial Double-tube Type Hot Gas Duct for the VHTR (초고온가스로의 동심축 이중관형 고온가스덕트에 대한 구조정산 방법론 제안)

  • Song, Kee-Nam;Kim, Y.W.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.717-724
    • /
    • 2008
  • Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source for nuclear hydrogen generation, which can produce hydrogen from water or natural gas. A primary hot gas duct (HGD) as a coaxial double-tube type cross vessel is a key component connecting the reactor pressure vessel and the intermediate heat exchanger for the VHTR. In this study, structural sizing methodology for the primary HGD with a coaxial double-tube of the VHTR that produces heat at temperatures in the order of $950^{\circ}C$ was suggested and a structural pre-sizing of it was carried out as an example.

  • PDF

Development of miniature bar-type structural fuses with cold formed bolted connections

  • Guan, Dongzhi;Yang, Sen;Jia, Liang-Jiu;Guo, Zhengxing
    • Steel and Composite Structures
    • /
    • v.34 no.1
    • /
    • pp.53-73
    • /
    • 2020
  • A novel all-steel miniature bar-type structural fuse (MBSF) with cold formed bolted connections is developed in this study, which consists of a central energy dissipation core cut from a smooth round bar, an external confining tube and nuts. Three types of cross sections for the central energy dissipation core, i.e., triple-cut, double-cut and single-cut cross sections, were studied. Totally 18 specimens were axially tested under either symmetric or asymmetric cyclic loading histories, where the parameters such as cut cross sectional area ratio, length of the yielding portion and cross sectional type were investigated. Numerical simulation of 2 representative specimens were also conducted. An analytical model to evaluate the bending failure at the elastic portion was proposed, and a design method to avoid this failure mode was also presented. The experimental results show that the proposed MBSFs exhibit satisfactory hysteretic performance under both the two cyclic loading histories. Average strain values of 8% and 4% are found to be respectively suitable for designing the new MBSFs as the ultimate strain under the symmetric and asymmetric cyclic loadings.

Design of Super Wide-Band Electromagnetic Wave Absorbers Using Cross-Slotted Ferrite in the Double-Layered Type (십자형 슬롯을 가지는 적층형 초광대역 페라이트 전파흡수체의 설계)

  • 김동일;전상엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.4
    • /
    • pp.346-352
    • /
    • 1996
  • A wide-band design method of double layered electromagnetic wave absorbers cross-slotted in the second layer(which has very wide band frequency characteristics) is proposed and discussed. The wide-band electromagnetic wave absorber can be designed under some approximations by the the- oretical model using the equivalent material constants method applied to the second layer. Based on the developed model, wide-band electromagnetic wave absorbers with excellent reflectivity characteristics in the frequency range of 30MHz to 3, 170MHz were designed.

  • PDF