• Title/Summary/Keyword: dose-rate

Search Result 3,166, Processing Time 0.033 seconds

Analysis on the Decrease of Planning Target Volume in the Case of Lung Radiation Surgery with the Application of Respiratory Gated Radiotherpy Method (폐암 환자의 방사선수술 시 호흡연동 방사선치료 방법의 적용을 통한 계획용표적체적 감소 효과 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mee-Sun;Jung, Jae-Uk
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.263-268
    • /
    • 2008
  • The application of a respiratory gated radiotherpy method to the lung radiation surgery was evaluated compared with the conventional method in which the whole tumor motion range is considered in the delineation of PTV (Planning target volume). The four dimensional CT simulation images were acquired for the five NSCLC (Non-small cell lung cancer) patients for radiation surgery. The respiratory gated plan was prepared with the 50% phase CT images and the conventional method was planned based on the ITV (Internal target volume) which include all the target volumes created in each phase CT images within a whole respiratory period. The DVH (Dose volume histogram) of OAR (Organ at risk) which calculated in each method was compared for the evaluation of the plan properness. The relative decrease of OARs' DVH were verified in the application of respiratory gated method. The average decrease rate were $16.88{\pm}9.97%$ in the bronchus, $34.13{\pm}19.15%$ in the spinal cord, $28.42{\pm}18.49%$ in the chest wall and $32.48{\pm}16.66%$ in the lung. Based on these results, we can verified the applicability and the effectiveness of the respiratory gated method in the lung radiation surgery.

  • PDF

Effect of Expeller Cake Fertilizer Application on Soil Properties and Red Mustard (Brassica Juncea L.) Yield in Soil of Organic Farm of Plastic Film Greenhouse (유기농 시설하우스 토양에서 유박 시용이 토양특성 및 적겨자 생육에 미치는 영향)

  • Kim, Kab-Cheol;Ahn, Byung-Koo;Kim, Hyung-Gook;Jeong, Seong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.6
    • /
    • pp.1022-1026
    • /
    • 2012
  • To evaluate the application level of expeller cake fertilizer (ECF), we have investigated soil chemical properties, leaf mineral contents and yield of red mustard in plastic film greenhouse. Four levels of fertilizer were applied as 50% (ECF 50), 75% (ECF 75), 100% (ECF 100) and 150% (ECF 150) by base $1,848kg\;kg^{-1}$ of ECF. In 2010, red mustard was planted on April 28 in silt loam soil and harvested on July 7. Commerical yields were measured 12 times from May 14 to July 7. Electrical conductivity ($3.40{\sim}3.54dS\;m^{-1}$), available $P_2O_5$ ($580{\sim}618mg\;kg^{-1}$) and exchangeable cations ($K^+$, $Ca^{2+}$ and $Mg^{2+}$) were tended to increase by the application of ECF. However, the range of those was not so big increasing amount. The content of T-N, K, Ca and P of red mustard leaves was $63.2{\sim}66.4g\;kg^{-1}$, $55.1{\sim}56.4g\;kg^{-1}$, $8.6{\sim}9.5g\;kg^{-1}$ and $5.7{\sim}6.3g\;kg^{-1}$, respectively. The nitrogen utilization rate of red mustard was 38~52%, and it was decreased with increased application of ECF. The yield of red mustard was 13,670 to $14,460kg\;ha^{-1}$ on the basis of application amount of ECF and the yield did not increased in spite of increased ECF. The optimum dose of application of ECF for cultivation of red mustard was from $924kg\;ha^{-1}$ (ECF 50) to $1,386kg\;ha^{-1}$ (ECF 75). Environment-friendly and economical amount of applied fertilizer is more important than yield for cultivation of red mustard.

Toxic evaluation of phenanthrene and zinc undecylenate using the population growth rates of marine diatom, Skeletonema costatum (해산규조류(Skeletonema costatum)의 개체군 성장률을 이용한 phenanthrene와 zinc undecylenate의 독성평가)

  • Lee, Ju-Wook;Choi, Hoon;Park, Yun-Ho;Lee, Yoon;Heo, Seung;Hwang, Un-Ki
    • Korean Journal of Environmental Biology
    • /
    • v.37 no.3
    • /
    • pp.372-379
    • /
    • 2019
  • We evaluated the toxic effects of phenanthrene (PHE) and zinc undecylenate (ZU) on the population growth rate (r) of the marine diatom, Skeletonema costatum. The r of S. costatum was determined after 96 hrs of exposure to PHE (0, 25, 50, 100, 200 and 300 mg L-1) and ZU (0, 5, 10, 15, 20 and 25 mg L-1). The results showed that r in the control (the absence of PHE and ZU) was greater than 0.04, while r in the treatment groups decreased with increasing PHE and ZU concentrations. PHE and ZU were shown to reduce r in a dose-dependent manner, with significant decreases occurring at concentrations above 50 and 10 mg L-1, respectively. The EC50 values of r in PHE and ZU exposure were 136.13 and 16.95 mg L-1, respectively. The no observed effect concentrations (NOEC) were 25 and 5 mg L-1, and the lowest observed effect concentrations (LOEC) were 50 and 10 mg L-1. These results indicated that concentrations of greater than 50 mg L-1 of PHE and 10 mg L-1 of ZU in marine ecosystems induced a toxic effect on the r of S. costatum. These results can serve as useful baseline data for the establishment of safety concentrations of PHE and ZU in marine ecosystems.

Arachidonate-induced Oxygen Radical Production and Cellular Damage in Ischemic-Reperfused Heart of Rat (허혈-재관류 적출심장에서 Arachidonic Acid에 의한 산소라디칼 생성 및 심근손상)

  • Lee, Yun-Song;Kim, Yong-Sik;Park, Seong-Ho;Myung, Ho-Jin;Kim, Myung-Suk
    • The Korean Journal of Pharmacology
    • /
    • v.27 no.2
    • /
    • pp.109-118
    • /
    • 1991
  • The present study was conducted to assess the possible contribution of arachidonic acid to generation of reactive oxygen metabolites and myocardial damage in ischemic-reperfused heart. Langendorff preparations of isolated rat heart were made ischemic by hypoperfusion (0.5 ml/min) for 45 min, and then followed by normal oxygenated reperfusion (7 ml/min). The generation of superoxide anion was estimated by measuring the SOD-inhibitable ferricytochrome C reduction. The myocardial cellular damage was observed by measuring LDH released into the coronary effluent. Oxygenated reperfusion following a period of ischemia produced superoxide anion, which was inhibited by both indomethacin (60 nmole/ml) and ibuprofen $(30\;{\mu}g/ml)$. Sodium arachidonate $(10^{-7}-10^{-2}{\mu}g/ml)$ administered during the period of oxygenated reperfusion stimulated superoxide anion production dose-dependently. The rate of arachidonate-induced superoxide generation was markedly inhibited by indomethacin, a cyclooxygenase inhibitor; nordihydroguaiaretic acid (NDGA), a lipoxygenase inhibitor, and by eicosatetraynoic acid (ETYA), a substrate inhibitor of arachidonic acid metabolism. The release of LDH was increased by Na arachidonate and was inhibited by superoxide dismutase. The release of LDH induced by arachidonic acid was also inhibited by indomethacin, NDGA and ETYA. In conclusion, the present result suggests that arachidonic acid metabolism is involved in the production of reactive oxygen metabolite and plays a contributory role in the genesis of reperfusion injuy of myocardium.

  • PDF

Influence of Intracerebroventricular Haloperidol on the Renal Function of the Rabbit (가토신장기능에 미치는 측뇌실내 Haloperidol의 영향)

  • Kim, Joong-Ky;Choi, Bong-Kyu;Kook, Young-Johng
    • The Korean Journal of Pharmacology
    • /
    • v.18 no.2
    • /
    • pp.103-117
    • /
    • 1982
  • In an effort to provide evidence as to the regulatory role of the central dopaminergic system on the renal function, the effects of centrally administered dopamine and its specific antagonist haloperidol were investigated. Haloperidol (HA) given intracerebroventricularly (i.c.v.) induced antidiuresis in doses of 15 and $50{\mu}g/kg$. With $15{\mu}g/kg$ sodium reabsorption in the tubules was increased, while with $50{\mu}g/kg$ free-water reabsorption was increased. However, a marked diuresis with increased sodium and potassium was observed with $150{\mu}g/kg$. Hemodynamic changes were not evident, indicating that the diuresis is of tubular origin. Dopamine (DA), on the other hand, produced antidiuresis when given i.c.v. in a dose-related fashion. With smaller doses of 5 and $15{\mu}g/kg$ the antidiuresis was related to increased reabsorption of sodium in the tubules, but higher doses of 50 and $150{\mu}g/kg$ the decreases in renal blood flow and glomerular filtration rate were evident in addition to the tubular action. After pretreatment with $150{\mu}g/kg$ HA, the effects of $15{\mu}g/kg$ DA was abolished, but the antidiuretic actions of 50 and $150{\mu}g/kg$ were not blocked, and the natriuretic diuretic action of HA was overcome and became inconspicuous. These observations indicate that the central dopaminergic system influences the renal function by producing antidiuresis, and HA elicits diuresis and natriuresis by competitively antagonizing DA specifically on the central dopaminegic receptors. The antidiuresis observed with smaller doses of HA can be best explained by the facts that there are more than two types of DA-receptors in the brain and that the presynaptic autoreceptors on the dopaminergic neurones which affect the dopamine release at the synapse are more sensitive than the postsynaptic receptors. Overall, these data provide an evidence indicating that the central dopaminergic system plays a role in the regulation of renal function in the rabbit.

  • PDF

A study on the accuracy of source position in HDR brachytherapy according to the curvature of Universal applicator transfer tube and applicator type (원격 후 장전치료기를 사용한 고선량률 근접치료시 기구의 형태와 선원 전달 도관의 곡률 변화에 따른 선원위치 정확성에 관한 고찰)

  • Shin, Hyeon Kyung;Lee, Sang Kyoo;Kim, Joo Ho;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • Purpose : The goal of this study was to verify and analyze the source position according to the curvature of the universal applicator and 4 different angle applicators when using RALS(Remote After Loading System). Materials and Methods : An interval of 1 cm and 15 second dwell times in each source position were applied for plan. To verify the accuracy of source position, we narrowed the distance between MultiSource container and GAFCHROMIC$^{(R)}$ EBT3 film by 5 cm, 10 cm, 20 cm so that the universal applicator transfer tube had some curvature. Also 4 applicators(Intrauterine tube: $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, Ovoid tube: $65^{\circ}$) were used in the same condition. The differences between desired and actual source position were measured by using Image J. Results : In case of using 4 different angles of applicator with the straight universal applicator transfer tube, the average error was the lowest for $0^{\circ}$ applicator, greatest for $65^{\circ}$ applicator. However, All average errors were within ${\pm}2mm$ recommended in TG-56. When MultiSource container was moved 5 cm, 10 cm, 20 cm towards the EBT3 film, the average errors were beyond ${\pm}2mm$. The first dwell position was relatively located in accuracy, while the second and third dwells were displaced by an increasing magnitude with increasing curvature of the transfer tube. Furthermore, with increasing the angle of applicators, the error of all other dwell positioning was increased. Conclusion : The results of this study showed that both the curvature of universal applicator transfer tube and the angle of applicators affect the source dwell position. It is recommended that using straight universal applicator transfer tubes is followed in all cases, in order to avoid deviations in the delivered source dwell position. Also, It is advisable to verify the actual dwell position, using video camera quality control tool prior to all treatments.

  • PDF

A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources (고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰)

  • Baek, Tae-Seong;Lee, Seung-Wook;Na, Soo-Kyong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Purpose: To compare of the accuracy among various measurement procedures of HDR Brachytherapy, and to evaluate the clinical suitability and usefulness of alternative PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom without any additional cost due to the purchase of measuring apparatus. Materials and Methods: We made a comparative study on three types of measuring systems: well type chamber, source calibration jig, and PMMA plate phantom. Farmer type chamber was used for source calibration jig method and PMMA plate phantom method. Measurement was done 5 times each in comparison with the measurement values from manufacturer. Measurement results from experiment were compared with that from the manufacturer which is offered with the source whenever a source is substituted by a new one and evaluate the accuracy of source activity. Results: As a consequence of Ir-192 source measurement using well type chamber, source calibration jig and PMMA plate phantom, RMS (Root Mean Square) values for the relative error are 0.6%, 1.57%, 2.1%, respectively, compared with the data from manufacturer. And the mean errors with standard deviation are given $-0.2{\pm}0.5%$, $0.97{\pm}1.23%$, $-0.89{\pm}1.87%$ respectively. Conclusion: From the results shown by the three types of measurement system (well type chamber, source calibration jig, and PMMA plate phantom), the measurement with well type chamber produced the best accuracy. It turns out that we can also use the alternative system of PMMA plate phantom clinically without purchasing any additional particular apparatus since the system does not exceed the recommendation of AAPM (American Association of Physicists in Medicine), which requires the error range of within ${\pm}5%$.

  • PDF

P53 Overexpression and Outcome of Radiation Therapy in Head & Neck Cancers (두경부종양 환자에서 p53의 과발현과 방사선치료결과)

  • Kim In Ah;Choi Ihl Bhong;Kang Ki Mun;Jang Ji Young;Kim Kyung Mi;Park Kyung Shin;Young Shin Kim;Kang Chang Suk;Cho Seung Ho;Kim Hyung Tae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 1999
  • Purpose : Experimental studies have implicated the wild type p53 In cellular response to radiation. Whether altered p53 function can lead to changes in clinical radiocurability remains an area of ongoing study. This study was performed to investigate whether any correlation between change of p53 and outcome of curative radiation therapy in patients with head and neck cancels. Methods : Immunohistochemical analysis with a mouse monoclonal antibody (DO-7) specific for human p53 was used to detect to overexpression of protein in formalin fixed, paraffin-embedded tumor sample from 55 head and neck cancer patients treated with curative radiation therapy (median dose of 7020 cGy) from February 1988 to March 1996 at 51. Mary's Hospital. Overexpression of p53 was correlated with locoregional control and survival using Kaplan-Meier method. A Cox regression multi-variate analysis was peformed that included all clinical variables and status of p53 expression. Results : Thirty-seven (67.2$\%$) patients showed overexpression of p53 by immunohistochemical staining in their tumor. One hundred percent of oral cavity, 70$\%$ of laryngeal, 66.7$\%$ of oropharyngeal, 66.7$\%$ of hypopharyngeal cancer showed p53 overexpression (P=0.05). The status of p53 had significant relationship with stage of disease (P=0.03) and history of smoking (P=0.001). The overexpression of p53 was not predictive of response rate to radiation therapy. The locoregional control was not significantly affected by p53 status. Overexpression of p53 didn't have any prognostic implication for disease free survival and overall survival. Primary site and stage of disease were significant prognostic factors for survival. Conclusions : The p53 overexpression as detected by immunohistochemical staining had significant correlation with stage, primary site of disease and smoking habit of patients. The p53 overexpression didn't have any predictive value for outcome of curative radiation therapy in a group of head and neck cancers.

  • PDF

Concurrent Chemoradiotherapy with Biweekly Gemcitabine and Cisplatin in Patients with Locally Advanced Non-small Cell Lung Cancer (진행성 비소세포폐암 환자에서 Gemcitabine/Cisplatin을 이용한 동시 화학 방사선 요법)

  • Oak, Chul-Ho;Kim, Ja-Kyung;Jang, Lee-La;Moon, Dae-Sung;Jang, Tae-Won;Jung, Maan-Hong;Cho, Sung-Whan;Jeung, Tae-Sig
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.160-165
    • /
    • 2008
  • Purpose: In cases of locally advanced non-small cell lung cancer (NSCLC), concurrent chemoradiotherapy(CCRT) is the leading therapeutic modality. However, much controversy exists about the chemotherapeutic regimens and radiation methods. Materials and Methods: During concurrent chemoradiotherapy, three or four cycles of gemcitabine ($500\;mg/m^2$) and cisplatin ($30\;mg/m^2$) were administered every two weeks while 50.4 Gy of irradiation was administered in 28 fractions (once/day, 5 treatment days/week) to the tumor site, mediastinum, and the involved lymph node region. In addition, a booster irradiation dose of 18 Gy in 10 fractions was administered to the primary tumor site unless the disease progressed. Two or three cycles of consolidation chemotherapy were performed with gemcitabine ($1,200\;mg/m^2$, $1^{st}$ and 8th day) and cisplatin ($60\;mg/m^2$) every three weeks. Results: A total of 29 patients were evaluable for modality response. Response and treatment toxicities were assessed after concurrent chemoradiotherapy and consolidation chemotherapy, respectively. One patient (4%) achieved a complete response; whereas 20 patients (69%) achieved a partial response after concurrent chemoradiotherapy. Following the consolidation chemotherapy, three patients (10.3%) achieved complete responses and 21 patients (72.4%) achieved partial responses. The median follow-up period was 20 months (range $3{\sim}39$ months) and the median survival time was 16 months (95% CI; $2.4{\sim}39.2$ months). The survival rates in one, two, and three years after the completion of treatment were 62.7%, 43.9%, and 20%, respectively. Complications associated to this treatment modality included grade 3 or 4 esophagitis, which occurred in 15 patients (51.7%). In addition, an incidence of 24% for grade 3 and 14% for grade 4 neutropenia. Lastly, grade 2 radiation pneumonitis occurred in 6 patients (22%). Conclusion: The response rate and survival time of concurrent chemoradiotherapy with biweekly gemcitabine ($500\;mg/m^2$) and cisplatin ($30\;mg/m^2$) were encouraging in patients with locally advanced NSCLC. However, treatment related toxicities were significant, indicating that further modification of therapy seems to be warranted.

The Use of MTT Assay, In Vitro and Ex Vivo, to Predict the Radiosensitivity of Colorectal Cancer (In-vitro와 Ex-vivo MTT Assay를 통한 직장암의 방사선치료 감수성 예측 가능성 검증)

  • Kim, Ji-Eun;Kim, Mi-Sook;Kang, Chang-Mo;Kim, Jong-Il;Shin, Hye-Kyung;Choi, Chul-Won;Seo, Young-Seok;Ji, Young-Hoon
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.166-172
    • /
    • 2008
  • Purpose: The measurement of radiosensitivity of individuals is useful in radiation therapy. Unfortunately, the measurement of radiation survival using a clonogenic assay, which is the established standard, can be difficult and time consuming. The aim of this study is to compare radiosensitivity results obtained from the MTT and clonogenic assays, and to evaluate whether the MTT assay can be used on clinical specimens. Materials and Methods: HCT-8, LoVo, CT-26, and WiDr were the colon cancer cell lines used for this study. The clonogenic assay was performed to obtain the cell survival curves and surviving fractions at a dose of 2 Gy ($SF_2$) as the standard technique for radiosensitivity. Also, the MTT assay was performed for each of the cell lines (in vitro). To simulate clinical specimens, the cell lines were inoculated into nude mice, removed when the tumors reached 1 cm in diameter, and chopped. Next, the tumors were subjected to the same process involved with the MTT assay in vitro. The inhibition rates (IR) of 10 Gy or 20 Gy of irradiation for in vitro and ex vivo were calculated based on the optical density of the MTT assay, respectively. Results: According to $SF_2$ and the cell survival curve, the HCT-8 and WiDr cell lines were more resistant to radiation than LoVo and CT-26 (p<0.05). The IR was measured by in vitro. The MTT assay IR was 17.3%, 21%, 30% and 56.5% for the WiDr, HCT-8, LoVo and CT-26 cell lines, respectively. In addition, the IR measured ex vivo by the MTT assay was 23.5%, 26%, 38% and 53% in the HCT-8, WiDr, LoVo and CT-26 tumors, respectively. Conclusion: The radiosensitivity measured by the MTT assay was correlated with the measures obtained from the clonogenic assay. This result highlights the possibility that the MTT assay could be used in clinical specimens for individual radiosensitivity assays.