Feasibility Study of Mobius3D for Patient-Specific Quality Assurance in the Volumetric Modulated Arc Therapy

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Lee, Jeongshim;Huh, Hyun Do
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.120-127
    • /
    • 2019
  • Purpose: This study was designed to evaluate the dosimetric performance of Mobius3D by comparison with an aSi-based electronic portal imaging device (EPID) and Octavius 4D, which are conventionally used for patient-specific prescription dose verification. Methods: The study was conducted using nine patients who were treated by volumetric modulated arc therapy. To evaluate the feasibility of Mobius3D for prescription dose verification, we compared the QA results of Mobius3D to an aSi-based EPID and the Octavius 4D dose verification methods. The first was the comparison of the Mobius3D verification phantom dose, and the second was to gamma index analysis. Results: The percentage differences between the calculated point dose and measurements from a PTW31010 ion chamber were 1.6%±1.3%, 2.0%±0.8%, and 1.2%±1.2%, using collapsed cone convolution, an analytical anisotropic algorithm, and the AcurosXB algorithm respectively. The average difference was found to be 1.6%±0.3%. Additionally, in the case of using the PTW31014 ion chamber, the corresponding results were 2.0%±1.4%, 2.4%±2.1%, and 1.6%±2.5%, showing an average agreement within 2.0%±0.3%. Considering all the criteria, the Mobius3D result showed that the percentage dose difference from the EPID was within 0.46%±0.34% on average, and the percentage dose difference from Octavius 4D was within 3.14%±2.85% on average. Conclusions: We conclude that Mobius3D can be used interchangeably with phantom-based dosimetry systems, which are commonly used as patient-specific prescription dose verification tools, especially under the conditions of 3%/3 mm and 95% pass rate.

MDCT 관상동맥 조영 검사에서 전향적 동조화 및 후향적 동조화 기법의 화질과 선량 관계 (An Estimate of Image Quality and Radiation Doses of Coronary Artery in MDCT Using Prospective and Retrospective ECG Gating Scan Mode)

  • 오종갑
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권4호
    • /
    • pp.315-321
    • /
    • 2011
  • 본 연구는 검사 기법에 따른 영상의 질과 방사선 피폭의 정도를 제시하여 검사자가 받는 방사선 피폭을 저감시키는 데 목적이 있다. 관상동맥 전산화 단층 혈관조영(Coronary CTA, coronary computed tomography angiography) 검사자를 대상으로 SnapShot Pulse의 전향적 동조화 기법과 SnapShot Segment의 후향적 동조화 기법으로 coronary CTA 검사에서 검사자가 받는 단면 피폭선량(CTDIvol, volume computed tomography dose index), 총 피폭선량(dose-length product; DLP)을 각각 측정하였다. 또한, Coronary CTA 촬영조건을 동일하게 팬텀을 이용하여 CT감약계수, 노이즈 및 균일도, 공간분해능을 측정하였다. 연구 결과 두기법에서 CT감약계수, 노이즈 및 균일도, 공간분해능의 질적 수준이 비슷하게 나타났으며, CTDIvol, DLP는 SnapShot Segment의 후향적 동조화 기법에 비해 피폭선량이 약 37.5%, 40.3% 감소되었다. 임상에서 coronary CTA 검사 시 SnapShot Pulse의 전향적 동조화 기법을 적극 채택하여 검사자가 받는 방사선 피폭을 감소시키기 위한 노력이 절실히 요구된다.

Leaf width가 다른 다엽 콜리메터에 의한 치료계획 비교 (Comparison of Treatment Plans with Multileaf Collimators of different Leaf Width)

  • 김주영;박성용;이두현;이석호;김태현;조관호
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.173-178
    • /
    • 2004
  • 목적: Leaf width가 다른 다엽 콜리메터(MLCs)를 이용, 두개내 병변에 관하여 각각의 세기조절방사선치료(IMRT) 계획을 수립하여, 이를 선량학적으로 비교하였다. 재료 및 방법: BrainSCAN ver. 5.2. 소프트웨어를 사용하여 micro-MLC로 이미 치료가 수행된 12명의 환자를 Varian사의 120 MLC와 80 MLC로 다시 치료계획하였으며 이 다엽 콜리메터들은 중심에서의 leaf width가 각각 3 mm, 5 mm, 10 mm이다. 이 때, 계획용 표적체적은 3.3~339.2 cc였고, 조사된 빔의 수는 3~7개이다. 이들을 uniformity Index, conformity index, 결정장기와 정상조직 내 선량으로 서로 비교하였다. 결과: 계획용 표적체적의 uniformity Index경우, mMLCs와 120 MLCs 사이에서 (p=0.057) 120 MLCs와 80 MLCs 사이에서(p=0.388) 통계적으로 차이가 없었다. 그러나 mMLCs와 80 MLCs 사이에서 차이를 보였다(p<0.001). 계획용 표적체적에 대한 최대 목표선량은 leaf width와 연관성이 없었다. 반면에, conformity Index의 경우는 mMLCs와 120 MLCs (p=0.003), mMLCs와 80 MLCs (p=0.003), 50 MLCs와 120 MLCs (p=0.003) 사이에서 통계적인 차이를 보였다. 처방선량의 70%와 50% 이상 조사되는 뇌간의 부피는 다엽 콜리메터의 leaf width가 증가함에 따라 증가하였다. 특히, leaf width의 변화에 따라 방사선에 조사되는 정상 뇌조직의 부피가 분명하게 변하였다. Leaf width가 3 mm인 다엽 콜리메터와 비교하였을 때, leaf width가 5 mm, 10 mm인 다엽 콜리메터의 부피 증가는 처방선량의 50% 이상 조사되는 정상조직의 경우, 각각 6.3%, 23.2%였고, 처방선량의 70% 이상 조사되는 정상조직의 경우, 각각 8.7%, 32.7%였다. 결론: 계획용 표적체적의 uniformity Index와 최대 목표선량은 leaf width와 연관성이 없었다. 그렇지만 conformity Index 는 leaf width가 감소함에 따라 향상되었다. 두개내 병변 치료시, 정상 뇌조직의 보존에 있어 leaf width 5 mm, 10 mm인 다엽 콜리메터를 이용한 치료계획보다 leaf width 3 mm인 다엽 콜리메터를 이용한 치료계획이 보다 효과적임을 알 수 있었다.

  • PDF

Size-Specific Dose Estimation In the Korean Lung Cancer Screening Project: Does a 32-cm Diameter Phantom Represent a Standard-Sized Patient in Korean Population?

  • Kim, Eun Young;Kim, Tae Jung;Goo, Jin Mo;Kim, Hyae Young;Lee, Ji Won;Lee, Soojung;Lim, Jun-tae;Kim, Yeol
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1179-1186
    • /
    • 2018
  • Objective: The purposes of this study were to evaluate size-specific dose estimate (SSDE) of low-dose CT (LDCT) in the Korean Lung Cancer Screening (K-LUCAS) project and to determine whether CT protocols from Western countries are appropriate for lung cancer screening in Korea. Materials and Methods: For participants (n = 256, four institutions) of K-LUCAS pilot study, volume CT dose index ($CTDI_{vol}$) using a 32-cm diameter reference phantom was compared with SSDE, which was recalculated from $CTDI_{vol}$ using size-dependent conversion factor (f-size) based on the body size, as described in the American Association of Physicists in Medicine Report 204. This comparison was subsequently assessed by body mass index (BMI) levels (underweight/normal vs. overweight/obese), and automatic exposure control (AEC) adaptation (yes/no). Results: Size-specific dose estimate was higher than $CTDI_{vol}$ ($2.22{\pm}0.75mGy$ vs. $1.67{\pm}0.60mGy$, p < 0.001), since the f-size was larger than 1.0 for all participants. The ratio of SSDE to $CTDI_{vol}$ was higher in lower BMI groups; 1.26, 1.37, 1.43, and 1.53 in the obese (n = 103), overweight (n = 70), normal (n = 75), and underweight (n = 4), respectively. The ratio of SSDE to $CTDI_{vol}$ was greater in standard-sized participants than in large-sized participants independent of AEC adaptation; with AEC, SSDE/$CTDI_{vol}$ in large- vs. standard-sized participants: $1.30{\pm}0.08$ vs. $1.44{\pm}0.08$ (p < 0.001) and without AEC, $1.32{\pm}0.08$ vs. $1.42{\pm}0.06$ (p < 0.001). Conclusion: Volume CT dose index based on a reference phantom underestimates radiation exposure of LDCT in standard-sized Korean participants. The optimal radiation dose limit needs to be verified for standard-sized Korean participants.

동적조형회전조사 시 표적종양의 위치변위와 조사반경의 변화에 따른 선량전달 오류분석 (Analysis of Dose Delivery Error in Conformal Arc Therapy Depending on Target Positions and Arc Trajectories)

  • 강민영;이보람;김유현;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권1호
    • /
    • pp.51-58
    • /
    • 2011
  • 본 연구의 목적은 회전조사 시 표적종양의 위치변위와 갠트리의 조사반경에 의한 치료깊이 변화에 따른 모의치료계획 결과와 선량전달 결과상의 오차를 분석하고자 하였다. 깊이 변위가 가장 이상적인 경우, 즉 팬텀의 중심에 표적이 위치한 경우와 한쪽으로 2.5 cm, 5 cm씩 치우친 경우로 나누어 모의실험하였다. 표적의 위치 변화에 따른 모의치료계획을 실시하기 위하여 IMRT Body 팬톰(I'mRT Phantom, Wellhofer Dosimetry, Germany)를 이용하여 전산화단층촬영장치(Computed Tomography, Light speed 16, GE, USA)로 데이터를 획득하였다. 획득된 영상을 이용하여 치료계획장치(Treatment Planning System, Eclipse, ver. 6.5, VMS, Palo Alto, USA)를 이용하여 정중앙, 2.5 cm, 5 cm에 가상의 치료표적을 만들어 모의치료계획을 수립하였다. 선형가속기(CL21EX, VMS, Palo Alto, USA)의 6 MV 광자선과 최근 개발된 Gafchromic 필름(EBT2, ISP, Wayne, USA)을 이용하여 선량분포를 측정하였고, 선량분석프로그램(OmniPro-IMRT, ver. 1.4, Wellhofer Dosimetry, Germany)을 이용하여 모의치료계획 데이터와 측정 데이터를 정량적으로 분석하였다. 분석프로그램으로 횡축방향 선량분포 프로파일(Cross-plane profile)과 선량분포를 정량적으로 분석하기 위하여 감마인덱스(DD: 3%, DTA: 2 mm) 히스토그람을 이용하였다. 표적과 표적주변의 선량분포는 Conformity index(CI), Homogeneity index(HI)를 이용하여 정량적으로 분석하였다. 치료표적 전체체적에 대한 100% 선량분포에 포함되는 체적을 비교하여 분석하였다. 표적의 위치가 5 cm 에 있는 경우 다문동적회전조사(Multiple Conformal Arc Therapy, MCAT)는 23.8%, 단일동적회전조사(Single Conformal Arc Therapy, SCAT)는 35.6%, 고정조사는 37%였고, 표적이 2.5 cm에 있는 경우 MCAT 61%, SCAT 21.5%, 고정조사 14.2%로 분석되었다. 표적의 위치가 중앙에 있는 경우 MCAT 70.5%, SCAT 14.1%, 고정조사 36.3%로 나타났다. 표적의 위치가 5 cm 치우쳐 있는 경우를 제외하고 MCAT의 100% 선량분포에 포함되는 체적이 가장 크게 나타났다. 감마인덱스 히스토그램 분석결과, SCAT의 경우 37.1, 27.3, 29.2로 MCAT의 경우 9.2, 8.4, 10.3에 비해 최소 2.8배, 최대 4배 오차가 크게 나타났다. 결론적으로, 동적조형회전조사 시 표적종양의 위치변이와 조사반경의 변화에 따라 선량전달오류의 가능성을 알 수 있었으며 치료표적의 위치가 정중앙이 아닐 경우, 깊이와 회전반경을 최적화함으로써 정확한 선량 전달을 할 수 있다고 생각한다.

Calculation of Jaws-only IMRT (JO-IMRT) dose distributions based on the AAPM TG-119 test cases using Monte Carlo simulation and Prowess Panther treatment planning system

  • Luong, Thi Oanh;Duong, Thanh Tai;Truong, Thi Hong Loan;Chow, James CL
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4098-4105
    • /
    • 2021
  • The aim of this study is to calculate the JO-IMRT dose distributions based on the AAPM TG-119 using Monte Carlo (MC) simulation and Prowess Panther treatment planning system (TPS) (Panther, Prowess Inc., Chico, CA). JO-IMRT dose distributions of AAPM TG-119 were calculated by the TPS and were recalculated by MC simulation. The DVHs and 3D gamma index using global methods implemented in the PTW-VeriSoft with 3%/3 mm were used for evaluation. JO-IMRT dose distributions calculated by TPS and MC were matched the TG-119 goals. The gamma index passing rates with 3%/3 mm were 98.7% for multi-target, 96.0% for mock prostate, 95.4% for mock head-and-neck, and 96.6% for C-shape. The dose in the planning target volumes (PTV) for TPS was larger than that for the MC. The relative dose differences in D99 between TPS and MC for multi-target are 1.52%, 0.17% and 1.40%, for the center, superior and inferior, respectively. The differences in D95 are 0.16% for C-shape; and 0.06% for mock prostate. Mock head-and-neck difference is 0.40% in D99. In contrast, the organ curve for TPS tended to be smaller than MC values. JO-IMRT dose distributions for the AAPM TG-119 calculated by the TPS agreed well with the MC.

Variation of optimization techniques for high dose rate brachytherapy in cervical cancer treatment

  • Azahari, Ahmad Naqiuddin;Ghani, Ahmad Tirmizi;Abdullah, Reduan;Jayamani, Jayapramila;Appalanaido, Gokula Kumar;Jalil, Jasmin;Aziz, Mohd Zahri Abdul
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1414-1420
    • /
    • 2022
  • High dose rate (HDR) brachytherapy treatment planning usually involves optimization methods to deliver uniform dose to the target volume and minimize dose to the healthy tissues. Four optimizations were used to evaluate the high-risk clinical target volume (HRCTV) coverage and organ at risk (OAR). Dose-volume histogram (DVH) and dosimetric parameters were analyzed and evaluated. Better coverage was achieved with PGO (mean CI = 0.95), but there were no significant mean CI differences than GrO (p = 0.03322). Mean EQD2 doses to HRCTV (D90) were also superior for PGO with no significant mean EQD2 doses than GrO (p = 0.9410). The mean EQD2 doses to bladder, rectum, and sigmoid were significantly higher for NO plan than PO, GrO, and PGO. PO significantly reduced the mean EQD2 doses to bladder, rectum, and sigmoid but compromising the conformity index to HRCTV. PGO was superior in conformity index (CI) and mean EQD2 doses to HRCTV compared with the GrO plan but not statistically significant. The mean EQD2 doses to the rectum by PGO plan slightly exceeded the limit from ABS recommendation (mean EQD2 dose = 78.08 Gy EQD2). However, PGO can shorten the treatment planning process without compromising the CI and keeping the OARs dose below the tolerance limit.

Dosimetric Comparison between Varian Halcyon Analytical Anisotropic Algorithm and Acuros XB Algorithm for Planning of RapidArc Radiotherapy of Cervical Carcinoma

  • Mbewe, Jonathan;Shiba, Sakhele
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.130-136
    • /
    • 2021
  • Purpose: The Halcyon radiotherapy platform at Groote Schuur Hospital was delivered with a factory-configured analytical anisotropic algorithm (AAA) beam model for dose calculation. In a recent system upgrade, the Acuros XB (AXB) algorithm was installed. Both algorithms adopt fundamentally different approaches to dose calculation. This study aimed to compare the dose distributions of cervical carcinoma RapidArc plans calculated using both algorithms. Methods: A total of 15 plans previously calculated using the AAA were retrieved and recalculated using the AXB algorithm. Comparisons were performed using the planning target volume (PTV) maximum (max) and minimum (min) doses, D95%, D98%, D50%, D2%, homogeneity index (HI), and conformity index (CI). The mean and max doses and D2% were compared for the bladder, bowel, and femoral heads. Results: The AAA calculated slightly higher targets, D98%, D95%, D50%, and CI, than the AXB algorithm (44.49 Gy vs. 44.32 Gy, P=0.129; 44.87 Gy vs. 44.70 Gy, P=0.089; 46.00 Gy vs. 45.98 Gy, P=0.154; and 0.51 vs. 0.50, P=0.200, respectively). For target min dose, D2%, max dose, and HI, the AAA scored lower than the AXB algorithm (41.24 Gy vs. 41.30 Gy, P=0.902; 47.34 Gy vs. 47.75 Gy, P<0.001; 48.62 Gy vs. 50.14 Gy, P<0.001; and 0.06 vs. 0.07, P=0.002, respectively). For bladder, bowel, and left and right femurs, the AAA calculated higher mean and max doses. Conclusions: Statistically significant differences were observed for PTV D2%, max dose, HI, and bowel max dose (P>0.05).

Liver CT 검사에서 프로토콜 변화에 따른 선량 감소와 영상의 질 개선에 관한 연구 (Improved Image Quality and Radiation Dose Reduction in Liver Dynamic CT Scan with the Protocol Change)

  • 조유진;조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권2호
    • /
    • pp.107-114
    • /
    • 2015
  • 간 역동적 CT(Liver Dynamic Computed Tomography; LDCT) 검사에서 일반적으로 사용하는 프로토콜과 관전압을 낮게 설정한 후 프로토콜을 변화시켰을 때 방사선량과 영상의 질을 비교하여 영상의 질을 유지하면서 방사선량을 감소시킬 수 있는 방안을 알아보고자 하였다. LDCT를 시행한 환자 중 신체질량지수(body mass index; BMI)가 18.5~24인 환자 40명을 대상으로 일반적인 복부 CT 검사 프로토콜을 적용한 A그룹 20명(관전압: 120 kVp, SAFIRE strength1)과 관전압을 낮게 설정한 B그룹 20명(관전압: 100 kVp, SAFIRE strength 0~5 적용)이었다. 영상의 질 평가는 동맥기의 간 실질 조직, 대동맥, 상장간막동맥, 복강동맥, 내장지방 그리고 백그라운드에 관심영역(region of interest; ROI)을 설정해 잡음(noise), 신호대 잡음비(signal to noise ratio; SNR), 대조도 대 잡음비(contrast to noise ratio; CNR), CT number를 측정 비교하였다. 또한 정성적 평가는 경험이 풍부한 영상의학과 전문의 2명이 0~3점까지로 평가하였다. 방사선량은 총 DLP(dose length product)와 유효선량, CTDIvol(volume computed tomography dose index)을 비교하였다. 관전압 100 kVp에서 SAFIRE가 높을수록 잡음은 감소하고, CT number는 증가하였다. 따라서 SNR과 CNR은 SAFIRE 단계가 높을수록 증가하였다. 관전압 120 kVp와 비교하여 잡음, SNR, CNR이 SAFIRE strength 2, 3에서 가장 유사하였다. 정성적 평가는 SAFIRE strength 2가 가장 많았고 관전압이 100 kVp일 때 영상의 질이 더 좋다고 평가한 경우는 SAFIRE 1이었다. 방사선량은 120 kVp에 비해 100 kVp에서 21.69% 감소하였다. BMI가 비교적 높지 않은 LDCT 검사의 경우 공장에서 출고될 당시에 관전압이 높게 설정되어 있어 불필요한 방사선피폭이 우려되고 있는 현실을 고려하면, 본 연구 결과에 따라 관전압을 낮게 설정하고 SAFIRE strength를 2로 조정하면 영상의 질 저하 없이 방사선량도 감소시킬 수 있을 것으로 사료된다.

다중표적 간암의 정위적체부방사선치료에서 무편평화여과기선질 용적변조회전치료의 유용성 평가 (A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam)

  • 염미숙;윤인하;홍동기;백금문
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.31-43
    • /
    • 2015
  • 목 적 : 정위적체부방사선치료(Stereotatic body radiation therapy, SBRT)는 원발성 종양과 전이성 종양의 치료법으로 이용되어진다. SBRT는 높은 선량을 전달하기 때문에 MU(Monitor unit)의 증가로 치료시간이 길어지고 치료계획용적(Planning Target Volume, PTV) 주변의 정상장기를 효과적으로 보호할 수 있는 치료계획이 필요하다. 특히 다중표적의 경우 SBRT를 여러 번에 나누어 치료해야하거나 선량 겹침으로 인한 고 선량 영역(Hot spot)이 생길수도 있다. 본 연구는 다중표적 간암에서 TrueBeam STx(Varian, USA)의 무편평화여과기선질(Flattening filter free, FFF) beam을 이용한 용적변조회전치료(Volumetric modulated arc therapy, VMAT)의 유용성을 평가하고자 한다. 대상 및 방법 : 다중표적 간암의 SBRT를 시행하는 5명의 환자를 대상으로 TrueBeam STx의 10MV FFF beam을 이용한 VMAT과 15MV 편평화여과기선질(Flattening filter, FF) beam을 이용한 입체조형치료(conformal radiotherapy, CRT)계획을 세웠다. 두 치료계획을 비교하기 위하여 선량용적히스토그램(Dose Volume Histogram, DVH)을 이용하여 치료계획용적(Planning Target Volume, PTV), 간, 십이지장, 장, 식도, 척수에 들어가는 선량을 평가하고 전체 MU 값을 비교하였다. 또한 두 치료계획의 치료시간을 비교하기 위하여 Beam on time을 평가하였다. 결 과 : PTV에 대한 처방선량지수(Conformity Index, CI), 선량균질지수(Homogeneity index, HI), 처방선량포함지수(Paddick's Conformity Index, PCI)의 평균값은 VMAT에서 각각 $1.006{\pm}0.028$, $1.098{\pm}0.016$, $1.132{\pm}0.084$, CRT에서 $1.381{\pm}0.419$ $1.136{\pm}0.042$, $1.534{\pm}0.465$로 평가되었다. 정상장기에 대한 선량은 CRT에서 VMAT 보다 약 1.8배 높은 선량으로 평가되었다. 전체 MU값은 VMAT에서 약 1.3배 높게 평가되었고 VMAT과 CRT 두 치료계획의 평균 Beam on time은 각각 6.8분, 21.3분으로 평가되었다. 결 론 : 다중표적 간암의 정위적체부방사선치료에서 FFF Beam을 이용한 VMAT을 적용하면 선량 겹침 없이 다중표적을 한 번에 치료할 수 있으며 PTV의 선량포함을 만족하면서 주위의 정상장기를 더 효과적으로 보호할 수 있는 치료계획이 가능하다. 또한 FFF Beam의 높은 선량률(Dose rate)을 이용하여 치료시간을 단축시켜 치료 중 발생할 수 있는 오차를 감소시킬 수 있다.