• Title/Summary/Keyword: dose equivalent

Search Result 527, Processing Time 0.027 seconds

A Comparison of Noise Level by Noise Measuring Methods (소음측정방법에 따른 평가소음도 비교)

  • Shim, Chur Goo;Roh, Jae hoon;Park, Jung Gyun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.128-136
    • /
    • 1995
  • The purpose of this study is to evaluate the difference of noise level according to noise measuring methods in the noisy working environments. Sound pressure level(SPL), equivalence sound level(Leq) and personal noise exposure dose(Dose) in the fifty-nine unit workplaces of the twenty-eight industries were measured and relating factors which were affected noise level were investigated. The results were as follows ; 1. The noise levels were $88.70{\pm}5.68dB(A)$ by SPL, $89.07{\pm}5.41dB(A)$ by Leq and $89.07{\pm}5.69$ by Dose. The differences of noise levels by three measuring methods were statistically significant(P<0.001) by repeated measure ANOV A. 2. Comparing with noise levels by general classes of noise exposure, noise levels of continuous noise were $89.14{\pm}5.19dB(A)$ by SPL, $89.45{\pm}4.65dB(A)$ by Leq and $90.04{\pm}5.09$ by Dose. Noise levels of intermittent noise were $87.90{\pm}6.52dB(A)$ by SPL, $88.40{\pm}6.63dB(A)$ by Leq and $90.10{\pm}6.80$ by Dose. The differences noise level of noise measuring methods by general classese of noise exposure were statistically not significant by repeated measure ANOV A. 3. Interaction between general classese of noise exposure and noise measuring methods for noise level was not statistically significant by repeated measure ANOVA. And the noise level by noise measuring methods were statistically significant by repeated measure ANOV A(P<.001) 4. Comparing with noise levels by unit workplace size, noise levels of large unit workplace were $90.73{\pm}5.87dB(A)$ by SPL, $91.32{\pm}5.50dB(A)$ by Leq and $91.82{\pm}6.06$ by Dose and noise levels of middle unit workplace were $88.31{\pm}5.26dB(A)$ by SPL, $88.41{\pm}4.83dB(A)$ by Leq and $89.69{\pm}5.05$ by Dose. And noise levels of small unit workplace were $94.89{\pm}4.10dB(A)$ by SPL, $85.35{\pm}4.11dB(A)$ by Leq and $86.87{\pm}4.98$ by Dose. The noise level differences of noise measuring methods by unit workplace size were statistically significant by repeated measure ANOV A(P<.05). 5. The noise level by noise measuring methods were statistically significant by repeated measure ANOV A(P<.001). But Interaction between workplace size and noise level measuring methods for noise level was not statistically significant by repeated measure ANOVA. According to the above results, there was a difference of the noise level among the three measuring methods. Therefore we must use the personal noise exposure dose using by noise dose meter, possible, to prvent occupational hearing loss in noisy working environment.

  • PDF

Developments of Space Radiation Dosimeter using Commercial Si Radiation Sensor (범용 실리콘 방사선 센서를 이용한 우주방사선 선량계 개발)

  • Jong-kyu Cheon;Sunghwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.367-373
    • /
    • 2023
  • Aircrews and passengers are exposed to radiation from cosmic rays and secondary scattered rays generated by reactions with air or aircraft. For aircrews, radiation safety management is based on the exposure dose calculated using a space-weather environment simulation. However, the exposure dose varies depending on solar activity, altitude, flight path, etc., so measuring by route is more suggestive than the calculation. In this study, we developed an instrument to measure the cosmic radiation dose using a general-purpose Si sensor and a multichannel analyzer. The dose calculation applied the algorithm of CRaTER (Cosmic Ray Telescope for the Effects of Radiation), a space radiation measuring device of NASA. Energy and dose calibration was performed with Cs-137 662 keV gamma rays at a standard calibration facility, and good dose rate dependence was confirmed in the experimental range. Using the instrument, the dose was directly measured on the international line between Dubai and Incheon in May 2023, and it was similar to the result calculated by KREAM (Korean Radiation Exposure Assessment Model for Aviation Route Dose) within 12%. It was confirmed that the dose increased as the altitude and latitude increased, consistent with the calculation results by KREAM. Some limitations require more verification experiments. However, we confirmed it has sufficient utilization potential as a cost-effective measuring instrument for monitoring exposure dose inside or on personal aircraft.

Toxicity and safety classification of 4 animal medicines - Focusing on venoms from bee, snake, blister beetle and scolopendrid - (일부 동물성 한약재의 독성과 안전성등급화 - 봉독, 사독, 반묘와 오공을 중심으로 -)

  • Park, Yeongchul;Lee, Sundong
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.20 no.1
    • /
    • pp.125-144
    • /
    • 2016
  • Objectives : About 13% of the medicines used by traditional korean medicines(TKM), are called animal medicines and are derived from non-herbal sources such as animals and insects. However, the clinical use of these preparations from animal medicines is often based on tradition and belief, rather than on evidence of toxicity and efficacy. As a result, animal medicines containing toxin have caused serious problems from injecting patients with venom. Here, various venoms frequently used as TKM were reviewed in terms of their instinct toxity and tried to estimate their safety classification. Methods : The estimation of safety classification was based on human equivalent dose(HED)-based MOS (margin of safety) and clinical dose applied for patients. Results and Conclusions : Except that of snake venom due to no clinical dose, they were evaluated as class 3 for bee venom, class 4 for cantharidin, toxin from blister beetle, and class 1 for venom from scolopendrid. In conclusion, animal medicines showed a wide range of safety classification from class 1 to class 4. This wide range is estimated to result from extremely limited applications of each venom for patients because of their strong toxicity. However, it should be cautious for application in clinics since animal medicines can produce anaphylactic reactions particularly after veinous administration even with a tiny amount of venom.

A Study on the Removal Characteristics of Microcystin in the Water Treatement Plant by Ozonation (오존산화에 의한 정수장의 Microcystin제거 특성에 관한 연구)

  • 김민규;권재현;조영하;이진애;권오섭
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.74-83
    • /
    • 2003
  • Microcystin, stable compounds with circular heptapeptides, is presented inside cyanobacterial cell. So far, over 30 types have been known to exist and microcystin-LR, RR among them are the most potent toxin compound. By this reason, a strong oxidant, ozone was used in this study to remove the microcystins produced by cyanobacteria. Removal efficiency of microcystin at M water treatment plant was also evaluated. Microcystin concentration was determined by protein phosphatase inhibition assay. The results showed that dissolved microcystin in raw water detected in the range of 0.011-0.028 ㎍ Microcystin-RR equivalent/l. Above 98% of microcystin was removed through overall treatment system. Therefore, the water treatability of M treatment plant seemed to be excellent. Removal efficiency of microcystin according to unit process varied as characteristics of raw water such as DOC, UV/sub 254/ and turbidity. Removal efficiency of microcystin by ozonation was investigated in laboratory according to contact time and ozone dose. Dissolved microcystin was increased by twice fold according to ozone contact time, but increased by fifth fold according to ozone dose. So, changing of ozone dose more affected microcystin release than changing of ozone contact time. Behavior of microcystin by ozonation was similar to that of DOC, and residual ozone concentration gave influence to removal ratio of microcystin. In conclusion, single ozone treatment wasn't effective on microcystin removal in case of water containing a lot of cells. Therefore, it's more effective to use ozonation process after the removal of cyanobacterial cells in advance.

ANALYSIS OF NECKING DEFORMATION AND FRACTURE CHARACTERISTICS OF IRRADIATED A533B RPV STEEL

  • Kim, Jin Weon;Byun, Thak Sang
    • Nuclear Engineering and Technology
    • /
    • v.44 no.8
    • /
    • pp.953-960
    • /
    • 2012
  • This paper reports the irradiation effect on the deformation behavior and tensile fracture properties of A533B RPV steel. An inverse identification technique using iterative finite element (FE) simulation was used to determine those properties from tensile data for the A533B RPV steel irradiated at 65 to $100^{\circ}C$ and deformed at room temperature. FE simulation revealed that the plastic instability at yield followed by softening for higher doses was related to the occurrence of localized necking immediately after yielding. The strain-hardening rate in the equivalent true stress-true strain relationship was still positive during the necking deformation. The tensile fracture stress was less dependent on the irradiation dose, whereas the tensile fracture strain and fracture energy decreased with increasing dose level up to 0.1 dpa and then became saturated. However, the tensile fracture strain and fracture energy still remained high after high-dose irradiation, which is associated with a large amount of ductility during the necking deformation for irradiated A533B RPV steel.

The Pathological Changes of Stomach in Experimental Rats following Single Irradiation of Supervoltage (고에너지 방사선으로 단일조사한 백서위의 병리조직학적 변화에 관한 연구)

  • Choi, Myung-Sun;Suh, Won-Hyuck
    • Radiation Oncology Journal
    • /
    • v.2 no.1
    • /
    • pp.25-32
    • /
    • 1984
  • The pathological changes of stomach of the rat following 1,000 rad and 1,800 rad single exposure by Cobalt-60 has been made with 50 experimental rats. The dose of 1,000 rad and 1,800 rad single exposure were equivalent of biologic effect of 2,500 rad in 2 1/2 weeks and 6,000 rad in 6 weeks. Following single exposure, the groups of rat were terminated in 1, 2, 4, 8, 12 weeks intervals and the stomach were fixed to formalin solution immediatly after dissection. The pathological changes were as follows : 1. Following 1,000 rad single exposure, the stomach show only mild to moderate submucosal edema in 4,8,12 weeks group. 1 and 2 weeks group show no changes. 2. Following 1,800 rad single exposure, $32\%(8/25)$ of rats were dead by radiation effect and all other groups of stomach revealed variable pathological changes such as submucosal edema, squamous dysplasia, squamous papilloma as well as squamous cell carcinoma. 3. Optimal tolerance dose to the stomach was $4,500\~5,000$rad when irradiation given by supervoltage. The entire stomach was included within the irradiation field, the dose to the stomach should not exceed 6,000 rad. 4. In conclusion, the radiation injury to the stomach were more direct radiation effects to the gastric mucosa rather than secondary changes of radiation injured vessels.

  • PDF

Dose Characteristics of Stereotatic Radiosurgery CONE used for ML-6M Linear Accelerator (ML-6M LINAC에 장착한 Radiosurgery Cone의 Beam 특성에 대한 고찰)

  • Moon, Un-Chull;Kim, Hyun-Jin;Kim, Young-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.15-31
    • /
    • 1995
  • The radiosurgery treatment is one time, non surgical approach to the treatment of patients with intracranial disorders whose conditions would be difficult or dangerous to treat with conventional sugical procedures. The LINAC based radiosurgery is based on the combination of multiple isocentric arc irradiation with small fields centered in the stereotactic target. The absorption of the beam in a tissue equivalent medium, such as water, as well as the uniformity, or profile, of the beam must be precisely documented. The beam characteristics and dosimetric measurememts of the 6MV X-ray beam from a ML-6M linear accelerator are examined. The percent depth dose (PDD) and beam profile (including flatness, symmetry and penumbra) is calibrated with the radiosurgery cone in water phantom. The cone is made of lead which size is from $10{\times}10mm{\phi}$ to $30{\times}30mm{\phi}$ All of these dosimetric measurements sufficiently characterized the beam to permit safe clinical use.

  • PDF

Study on the Motion Sickness Incidence in Express Buses (장거리 여행용 버스에서의 멀미발생 예측에 관한 연구)

  • 장한기;김승한;송치문;김성환;홍석인
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.234-240
    • /
    • 2003
  • This study aims to investigate dynamic properties of express buses in the very low frequencies which affect motion sickness incidence. Since passengers often use express buses for long distance traveling, it is a critical point whether a give rise to motion sickness or not. In the study accelerations at the three points on the floor of the six test vehicles were measured during the driving at constant speeds. By applying frequency weighting curves suggested in ISO 2631-1 and ISO 2631-3, physical amount of accelerations were changed into perceptual amount which determines incidence of motion sickness. Motion sickness dose values were calculated from the frequency weighted time history of accelerations, and compared between the vehicles, driving conditions, and the seat positions in the bus. During the driving on public road and high ways for 50 minutes vomiting incidence ratios ranged 0.4 to 0.8%, which were equivalent to 2.4 to 4.8% for 5 hours' driving. The value of 4.8 % means two among 45 passengers may vomit after the traveling, which is very serious situation. Considering the very smooth driving condition at which the data were collected, motion sickness dose values will increase in real situations

  • PDF

Evaluation of Bolus Applicability through Dose Evaluation According to 3D Print Materials (3D 프린트 소재에 따른 선량평가를 통한 볼루스 적용성 평가)

  • Kim, Jung-Hoon;Lee, Deuk-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.241-246
    • /
    • 2019
  • Among the 4th Industrial Revolution technologies, evaluated bolus applicability through dose assesment according to the materials of 3D printing technology. Dose assesment was using MCNPX which was applied Monte Carlo method and 3D print materials were ABS, PC and PLA. Thus, the thickness with the same effect as the bolus 10 mm was found to be ABS 10 mm, PC 9 mm and PLA 9 mm for the 6 MeV electron. For 6 MV X-ray, ABS 11 mm, PC 10 mm and PLA 9 mm were shown. This study showed that tissue equivalent materials made from 3D printer materials can replace bolus.