• Title/Summary/Keyword: dose comparison

Search Result 1,104, Processing Time 0.024 seconds

Anti-obesity effect of Polygala tenuifolia (원지(Polygala tenuifolia)의 항비만 효과)

  • Hwang, Ju-Young;Wu, Yong-Xiang;Hwang, Dae-Il;Bae, Suk-Jae;Kim, Taewan
    • Food Science and Preservation
    • /
    • v.21 no.1
    • /
    • pp.97-106
    • /
    • 2014
  • This study was performed in order to investigate the anti-obesity effect of Polygala tenuifolia on lipid mechanism in 3T3-L1 adipocytes. The chemical composition of the P. tenuifolia was analyzed in order to assess its nutritional value. Total dietary fiber was the highest among the proximate component of the P. tenuifolia. These results showed that the P. tenuifolia may be used as a potential functional ingredient for anti-obesity effect. Intracellular lipid droplets in the adipocyte were stained with oil-red O dye and quantified. In comparison to the control, lipid accumulation was significantly decreased by 40.1% and 22.4% when treated with the water extract and 70% EtOH extract of the P. tenuifolia at the concentration of $10{\mu}g/mL$, respectively. The anti-adipogenic effect of the water extract was stronger than that of the 70% EtOH extract. The gene expression levels were measured via Western blot and real-time PCR. As a result, the water extract was found to have decrease the gene expression of SREBP-1c, PPAR, $C/EBP{\alpha}$, FAS, ACC in a dose-dependent manner. These indicate that the water extract inhibits pre-adipocyte differentiation and adipogenesis by blocking the SREBP-1c gene expression in 3T3-L1 cells. Therefore, P. tenuifolia can be used as an effective anti-obesity agent.

The Effect of Sahyangsohapwon on Heart Rate Variability of Healthy Subjects (사향소합원(麝香蘇合元)이 정상인의 심박변이도에 미치는 영향)

  • Kim, Chang-Hyun;Hwang, Jae-Woong;Min, In-Kyu;Kim, Mi-Young;Byeon, Hyung-Sik;Na, Byong-Jo;Park, Sung-Wook;Park, Jung-Mi;Ko, Chang-Nam;Bae, Hyung-Sup;Jung, Woo-Sang;Moon, Sang-Kwan;Cho, Ki-Ho;Kim, Young-Suk
    • The Journal of Korean Medicine
    • /
    • v.30 no.1
    • /
    • pp.120-127
    • /
    • 2009
  • Objectives: Sahyangsohapwon (SS) is a herbal medication that has been widely used with circulatory and neural diseases. This study was conducted to assess the effect of SS on the autonomic nervous system by using heart rate variability measurement. Methods: The eligible subjects were enrolled from the healthy male group of ages 20 to 35 years. They were divided into two groups, the SS group (n=26) and the control (n=24). We monitored the ECG of subjects from the time period 14:00 to 18:00. In the SS group, subjects were administered with a dose of SS at the time 15:00, whereas the control group had none. For each hour HRV measurement was monitored every 15 minutes for 512 seconds from the time period 14:00 to 18:00. The mean value, which was calculated using the 4 values during each hour (i.e. 14:00, 14:15, 14:30, 14:45), was used as the representative value for each individual hour. For the measurement values, RR-interval and SDNN (standard deviation of the NN intervals) were used as time domain analysis, and HF (high frequency), LF (low frequency), and LF/HF ratio were used as frequency domain analysis. Results: The LF value showed an increase after one hour of SS administration and showed gradual diminution for each and every hour. The repeated measures of ANOVA for the comparison of the LF value between the SS group and the control group showed significant differences. While, RR interval, SDNN, HF, and LF/HF ratio values showed no significant differences between the two groups. Conclusions: We suggest that the SS might be useful for stabilizing autonomic nervous system by inhibiting sympathetic nerve activation in healthy people.

  • PDF

Photocatalytic Oxidation of Arsenite Using Goethite and UV LED (침철석과 자외선 LED를 이용한 아비산염의 광촉매 산화)

  • Jeon, Ji-Hun;Kim, Seong-Hee;Lee, Sang-Woo;Kim, Soon-Oh
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.1
    • /
    • pp.9-18
    • /
    • 2017
  • Arsenic (As) has been considered as the most toxic one among various hazardous materials and As contamination can be caused naturally and anthropogenically. Major forms of arsenic in groundwater are arsenite [(As(III)] and/or arsenate [(As(V)], depending on redox condition: arsenite and arsenate are predominant in reduced and oxidized environments, respectively. Because arsenite is much more toxic and mobile than arsenate, there have been a number of studies on the reduction of its toxicity through oxidation of As(III) to As(V). This study was initiated to develop photocatalytic oxidation process for treatment of groundwater contaminated with arsenite. The performance of two types of light sources (UV lamp and UV LED) was compared and the feasibility of goethite as a photocatalyst was evaluated. The highest removal efficiency of the process was achieved at a goethite dose of 0.05 g/L. Based on the comparison of oxidation efficiencies of arsenite between two light sources, the apparent performance of UV LED was inferior to that of UV lamp. However, when the results were appraised on the basis of their emitting UV irradiation, the higher performance was achieved by UV LED than by UV lamp. This study demonstrates that environmentally friendly process of goethite-catalytic photo-oxidation without any addition of foreign catalyst is feasible for the reduction of arsenite in groundwater containing naturally-occurring goethite. In addition, this study confirms that UV LED can be used in the photo-oxidation of arsenite as an alternative light source of UV lamp to remedy the drawbacks of UV lamp, such as long stabilization time, high electrical power consumption, short lifespan, and high heat output requiring large cooling facilities.

BIOMECHANICS OF ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES UNDER UNILATERAL LOADING

  • Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Jeong-Taek;Roh, Hyun-Ki;Kim, Hyo-Jin;Lee, Seok-Hyung;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.753-759
    • /
    • 2007
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress under unilateral loading specially. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs under unilateral loading, using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1: Clasp-retained mandibular removable partial denture with unsplinted abutments Group 2: Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge. Group 3: Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm dose to the abutments. Two unilateral vertical experimental loadings (30N and 100N) were applied subsequently via miniature load cell that were placed at mandibular left first molar region. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Tukey test was used as post hoc comparisons. Results. The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Strain values increased as the applied load in increased from 30N to 100N (p<.05) except for right side in group 1. Under 30N loading, in left side, group 1 showed higher strain values than groups 2 and 3 in absolute quantity (p<.05). And group 2 showed higher strain values than group 1 (p<.05). In right side, group 1 and 2 showed higher strain values than group 3 in absolute quantity (p<.05). Under 100N loading in left side, group 1 showed higher strain values than groups 2 and 3 in absolute quantity (p<.05). And group 2 showed higher strain values than group 1 (p<.05). In right side, group 1 and 2 showed higher strain values than group 3 in absolute quantity (p<.05). Under 30N loading, group 2 and 3 showed higher strain values in right side than in left side. Under 100N loading, right side strain values were higher than left side ones for all groups. Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments under unilateral loading. Bar-retained removable partial denture showed the lowest strain of three groups, and compressive nature.

Assessment of the Specificity of A Hybridization of Surfactant Protein A by Addition of Non-specific Rat Spleen RNA (Surfactant Protein A mRNA을 이용한 유전자 재결합 반응에서 비특이성 RNA의 첨가에 의한 특이성 검정)

  • Kim, Byeong Cheol;Kim, Mi Ok;Kim, Tae-Hyung;Sohn, Jang Won;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.4
    • /
    • pp.393-404
    • /
    • 2004
  • Background : Nucleic acid hybridization has become an essential technique in the development of our understanding of gene structure and function. The quantitative analysis of hybridization has been used in the measurement of genome complexity and gene copy number. The filter hybridization assay is rapid, sensitive and can be used to measure RNAs complementary to any cloned DNA sequence. Methods : The authors assessed the accuracy, linearity, correlation coefficient and specificity of the hybridization depending on the added dose(0, 1, 5, and $10{\mu}g$) of non-specific rat spleen RNA to hybridization of surfactant protein A mRNA. Filter hybridization assays were used to obtain the equation of standard curve and thereby to quantitate the mRNA quantitation. Results : 1. Standard curve equation of filter hybridization assay between counts per minute (X) and spleen RNA input (Y) was Y=0.13X-19.35. Correlation coefficient was 0.98. 2. Standard curve equation of filter hybridization assay between counts per minute (X) and surfactant protein A mRNA transcript input (Y) was Y=0.00066X-0.046. Correlation coefficient was 0.99. 3. Standard curve equation of filter hybridization assay between counts per minute (X) and surfactant protein A mRNA transcript input (Y) after the addition of $1{\mu}g$ spleen RNA was Y=0.00056X-0.051. Correlation coefficient was 0.99. 4. Standard curve equation of filter hybridization assay between counts per minute (X) and surfactant protein A mRNA transcript input (Y) after the addition of $5{\mu}g$ spleen RNA was Y=0.00065X-0.088. Correlation coefficient was 0.99. 5. Standard curve equation of filter hybridization assay between counts per minute (X) and surfactant protein A mRNA transcript input (Y) after the addition of $10{\mu}g$ spleen RNA was Y=0.00051X-0.10. Correlation coefficient was 0.99. Conclusions : Comparison of cpm/filter in a linear range allowed accurate and reproducible estimation of surfactant protein A mRNA copy number irrespective of the addition dosage of non-specific rat spleen RNA over the range $0-10{\mu}g$.

Analysis of Relative Output Factors for Cyberknife: Comparison of Son Chambers, Diode Detector and Films (사이버나이프 출력인자 분석: 전리함, 다이오드 검출기 및 필름)

  • Jang Ji-Sun;Shin Dong-Oh;Choi Byung-Ock;Lee Tae-Kyu;Choi Ihl-Bohng;Kim Moon-Chan;Kwon Soo-Il;Kang Young-Nam
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • The accuracy of the dosimetry in the Cyberknife system is accomplishing important role from all processes of the stereotactic radiosurgery. In this study, we estimated relative output factors for Cyberknife. All measurements were peformed by six different detectors: diode detector, X-Omat V film, Gafchromic EBT film, 0.015 cc, 0.125 cc and 0.6 cc ionization chamber The diode detector and three ionization chambers peformed using water phantom at 80 cm SSD and 1.5 cm depth. When the film measurements were peformed, the water phantom was replaced with a solidwater phantom. Each collimator normalized with respect to the output factor of the largest collimator (60 mm). For the collimators over than 30 mm, the output factors from the different detectors showed a good agreement within 0.5% except 0.6 cc ion chamber For the collimators less than 15 mm, there were substantial differences In the output factors among different detectors. That is, the value of output factor for the 5 mm collimator of a diode and Gafchromic film was each $0.656{\pm}0.009$ and $0.777{\pm}0.013$. In the ion chamber and diode detector, those difference were due to the presence of large dose gradients and lack of electronic equilibrium in narrow megavoltage x-ray beams Therefore, the Gafchromic EBT film were considered more accurate than the others detectors.

  • PDF

A Study of Various Filter Setups with FBP Reconstruction for Digital Breast Tomosynthesis (디지털 유방단층영상합성법의 FBP 알고리즘 적용을 위한 다양한 필터 조합에 대한 연구)

  • Lee, Haeng-Hwa;Kim, Ye-Seul;Lee, Youngjin;Choi, Sunghoon;Lee, Seungwan;Park, Hye-Suk;Kim, Hee-Joung;Choi, Jae-Gu;Choi, Young-Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.271-280
    • /
    • 2014
  • Recently, digital breast tomosynthesis (DBT) has been investigated to overcome the limitation of conventional mammography for overlapping anatomical structures and high patient dose with cone-beam computed tomography (CBCT). However incomplete sampling due to limited angle leads to interference on the neighboring slices. Many studies have investigated to reduce artifacts such as interference. Moreover, appropriate filters for tomosynthesis have been researched to solve artifacts resulted from incomplete sampling. The primary purpose of this study is finding appropriate filter scheme with FBP reconstruction for DBT system to reduce artifacts. In this study, we investigated characteristics of various filter schemes with simulation and prototype digital breast tomosynthesis under same acquisition parameters and conditions. We evaluated artifacts and noise with profiles and COV (coefficinet of variation) to study characteristic of filter. As a result, the noise with parameter 0.25 of Spectral filter reduced by 10% in comparison to that with only Ramp-lak filter. Because unbalance of information reduced with decreasing B of Slice thickness filter, artifacts caused by incomplete sampling reduced. In conclusion, we confirmed basic characteristics of filter operations and improvement of image quality by appropriate filter scheme. The results of this study can be utilized as base in research and development of DBT system by providing information that is about noise and artifacts depend on various filter schemes.

Protective Effect of a Herbal Preparation (HemoHIM) on the Self-Renewal Tissues and Immune System against γ-Irradiation (방사선에 대한 생약복합조성물(HemoHIM)의 재생조직 및 면역계 방호 · 회복촉진 효과)

  • Jo, Sung-Kee;Park, Hae-Ran;Jung, Uhee;Oh, Heon;Kim, Sung-Ho;Yee, Sung-Tae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.6
    • /
    • pp.805-813
    • /
    • 2005
  • In our previous study, a novel herb mixture (HIM-I) of Angelim gigas radix, Cnidium officinale rhizoma, and Paeonia japonica radix was developed to protect the intestinal and immune systems and promote its recovery against radiation damage. In this study, a new herbal preparation (HemoHIM) with the high immune modulating activity was developed from HIM-I. HIM-I was fractionated into ethanol fraction (HIM-I-E) and polysaccharide fraction (HIM-I-P). And HemoHIM was prepared by adding HIM-I-P to HIM-I. The protective activities against $\gamma$ -irradiation were compared among HemoHIM, HIM-I and the fractions. HemoHIM and HIM-I significantly decreased the radiation-induced DNA damage in vitro, and scavenged hydroxyl radicals in a dose-dependent manner. HemoHIM showed similar activity to HIM-I. In vitro proliferation assay with mouse lymphocytes and bone marrow cells showed that HIM-I-P was remarkably higher than HIM-I and HIM-I-E in cell proliferating activity. HemoHIM showed higher activity than HIM-I and this might be associated with the higher polysaccharide content. The in vivo protective effects of HemoHIM and HIM-I were investigated in $\gamma$-irradiated mice. HemoHIM increased the surviving intestinal crypts to a similar extent compared with HIM-I. In contrast, HemoHIM appeared to be more effective than HIM-I in endogenous spleen colony formation assay. The recovery of white blood cells and lymphocytes in irradiated mice were significantly enhanced by the administration of HemoHIM. Also HemoHIM administration prolonged the survival of irradiated mice. These results showed that the novel herbal preparation, HemoHIM, effectively protected the self-renewal tissues and immune system, and promoted the survival of irradiated mice. Moreover, in comparison with HIM-I, HemoHIM maintained similar activity in the reduction of oxidative damage of self-renewal tissue but exhibited the higher activity in protection and proliferation of immune and hematopoietic cells. These results suggested that HemoHIM might be more effective than HIM-I in immune modulation as well as radioprotection.

Comparison of Liver, Kidney, Bone Metal Concentration in OhJeokSan-Treated Rats (오적산(五積散)을 투여한 흰쥐의 간장, 신장, 골중 금속농도 비교에 관한 연구)

  • Park Chul-Soo;Lee Sun-Dong;Park Hae-Mo;Park Yeong-Chul
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.6 no.2
    • /
    • pp.66-85
    • /
    • 2002
  • Traditional herbal medicine is used extensively among the Korean populations, and other Asian countries employ similar therapies as well In recent years, extensive focus was laid on adulteration of the herbal medicine with heavy metals. This may be mainly due to a soil contamination by an environmental pollution. The objective of this study is to identify the contents of various heavy metals in the blood from OhJeokSan-Decoction (OD) treated-rats. For this study, 13 kinds of metals including essential and heavy metals, i.e. Al, As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Se and Zn were analyzed by a slight modification of EPA methods and the following results are obtained. ; 1. There is no significant difference between the OD-treated groups and control group in liver, kidney, bone, brain, weight, food intake. 2. The amount of each metal analyzed in the liver are as follows; Al ; $0.235{\sim}4.215mg/kg$, As ; $0.103{\sim}0.461mg/kg$, Cd ; $0.005{\sim}0.010mg/kg$, Co ; $0.017{\sim}0.046mg/kg$, Cr ; $0.137{\sim}0.403mg/kg$, Cu ; $1.736{\sim}4.827mg/kg$, Fe ; $54.472{\sim}381.447mg/kg$, Hg ; not detected, Mn ; $1.159{\sim}2.803mg/kg$, Ni ; $0.007{\sim}0.095mg/kg$, Pb ; not detected, Se ; $0.682{\sim}1.887mg/kg$, Zn ; $10.213{\sim}26.119mg/kg$, by groups, respectively. In control and other experimental group, several metal (Co, Cu, Mn, Zn, As, Cr) has a significant difference, but in experimental I and other experimental II, III, IV, V groups, there are no significant difference. 3. The amount of each metal analyzed in the kidney are as follows; Al ; $1.712{\sim}31.230mg/kg$, As ; $0.062{\sim}0.439mg/kg$, Cd ; $0.010{\sim}0.062mg/kg$, Co ; $0.000{\sim}0.101mg/kg$, Cr ; $0.125{\sim}0.636mg/kg$, Cu ; $3.385{\sim}12.502mg/kg$, Fe ; $41.148{\sim}99.709mg/kg$, Hg ; $0.000{\sim}0.270mg/kg$, Mn ; $0.433{\sim}2.301mg/kg$, Ni ; $0.000{\sim}0.221mg/kg$, Pb ; $0.000{\sim}0.584mg/kg$, Se ; $0.540{\sim}1.600mg/kg$, Zn ; $8.775{\sim}17.060mg/kg$, by groups, respectively. The concentration of Cu, Se, Cr, and Hg are variated significantly in control and other experimental group, and Cu, Se, Cd, Cr are variated significantly in experimental I and other experimental II, III, IV, V groups. 4. The amount of each metal analyzed in the bone(tibia and fibula) are as follows; Al ; $9.557{\sim}119.464mg/kg$, As ; $0.139{\sim}12.250mg/kg$, Cd ; $0.000{\sim}0.295mg/kg$, Co ; $0.022{\sim}0.243mg/kg$, Cr ; $0.239{\sim}1.999mg/kg$, Cu ; $0.000{\sim}2.291mg/kg$, Fe ; $240.249{\sim}841.956mg/kg$, Hg ; $0.000{\sim}0.983mg/kg$, Mn ; $0.214{\sim}7.353mg/kg$, Ni ; $5.473{\sim}11.453mg/kg$, Pb ; $0.000{\sim}8.502mg/kg$, Se ; $0.000{\sim}3.005mg/kg$, Zn ; $61.158{\sim}195.038mg/kg$, by groups, respectively. The concentration of Se, Cd are variated significantly in control and other experimental groups, and Se is variated significantly in experimental I and other experimental II, III, IV, V groups. 5. Exceptionally several metal concentration is increased or decreased. but there is no significant harmful difference of metal concentration in the liver, kidney and bone, from the OD-treated-rats compared to those of the control group even if higher dosage($1{\sim}8$ times dosage of person) of OD was administered. Thus, it is expected that the herbal decoction in the traditional herbal medicine would not lay any burden on the body and the heavy metal toxins would not affect our physiological system. However, other kinds of herbal treatment, such as i.v. and i.p. should be considered in terms of metal toxicity in the body since the level of certain metal.

  • PDF

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.