• Title/Summary/Keyword: dose assessment

Search Result 945, Processing Time 0.022 seconds

Radiological Safety Assessment for a Near-Surface Disposal Facility Using RESRAD-ONSITE Code

  • Jang, Jiseon;Kim, Tae-Man;Cho, Chun-Hyung;Lee, Dae Sung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.1
    • /
    • pp.123-132
    • /
    • 2021
  • Radiological impact analyses were carried out for a near-surface radioactive waste repository at Gyeongju in South Korea. The RESRAD-ONSITE code was applied for the estimation of maximum exposure doses by considering various exposure pathways based on a land area of 2,500 ㎡ with a 0.15 m thick contamination zone. Typical influencing input parameters such as shield depth, shield materials' density, and shield erosion rate were examined for a sensitivity analysis. Then both residential farmer and industrial worker scenarios were used for the estimation of maximum exposure doses depending on exposure duration. The radiation dose evaluation results showed that 60Co, 137Cs, and 63Ni were major contributors to the total exposure dose compared with other radionuclides. Furthermore, the total exposure dose from ingestion (plant, meat, and milk) of the contaminated plants was more significant than those assessed for inhalation, with maximum values of 5.5×10-4 mSv·yr-1 for the plant ingestion. Thus the results of this study can be applied for determining near-surface radioactive waste repository conditions and providing quantitative analysis methods using RESRAD-ONSITE code for the safety assessment of disposing radioactive materials including decommissioning wastes to protect human health and the environment.

A new proposal for controlled recycling of decommissioning concrete waste as part of engineered barriers of a radioactive waste repository and related comprehensive safety assessment

  • In Gyu Chang;Jae Hak Cheong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.530-545
    • /
    • 2023
  • As an alternative to conventional management options for a lot of concrete waste from decommissioning of nuclear power plants, a set of scenarios for controlled recycling of decommissioning concrete waste as engineered barriers of a radioactive waste repository was proposed, and a comprehensive safety assessment model and framework covering both pre-and post-closure phases was newly developed. The new methodology was applied to a reference vault-type repository, and the ratios of derived concentration limits to unconditional clearance levels of eighteen radionuclides for controlled recycling were provided for three sets of dose criteria (0.01, 1, and 20 mSv/y for the pre-closure and 0.01 mSv/y for the post-closure phases). It turns out that decommissioning concrete waste whose concentration is much higher than the unconditional clearance level can be recycled even when the dose criterion 0.01 mSv/y is applied. Moreover, a case study on ABWR bio-shield shows that the fraction of recyclable concrete waste increases significantly by increasing the dose criterion for the radiation worker in the pre-closure phase or the duration of storage prior to recycling. The results of this study are expected to contribute to demonstrating the feasibility of controlled recycling of a lot of decommissioning concrete waste within nuclear sectors.

The Additional Filter and Ion Chamber Sensor Combination for Reducing Patient Dose in Digital Chest X-ray Projection (디지털 흉부엑스선 검사에서 환자선량 감소를 위한 부가필터와 Ion chamber 센서 조합)

  • Lee, Jinsoo;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.175-181
    • /
    • 2015
  • In this paper, we studied additional filter and Ion chamber combinations to reduce patient dose without decreasing image quality in digital chest x-ray projection. The experiment set 125 kVp, 320 mA, AEC mode. Ion chamber sensors was divided by 4 cases of combinations, then, we measured patient dose and calculated organ dose using PCXMC. Also, physical image assessment using MTF was performed. As a results, The surface entrance dose and organ dose were the lowest when selecting both left and right Ion chamber sensors under the same conditions of additional filter. In image quality assessment, The spatial frequency scored 2.494 lp/mm which was highest when selecting both right and left Ion-chambers and 0.1 mmCu filter. And to conclude, to select both right and left Ion chamber sensors and 0.1 mmCu filter will help for acquiring good quality image as well as reducing patient dose.

Verification of Harmonization of Dose Assessment Results According to Internal Exposure Scenarios

  • Kim, Bong-Gi;Ha, Wi-Ho;Kwon, Tae-Eun;Lee, Jun-Ho;Jung, Kyu-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.143-153
    • /
    • 2018
  • Background: The determination of the amount of radionuclides and internal dose for the worker who may have intake of radionuclides results in a variation due to uncertainty of measurement data and ingestion information. As a result of this, it is possible that for the same internal exposure scenario assessors could make considerably different estimation of internal dose. In order to reduce this difference, internal exposure scenarios for nuclear facilities were developed, and intercomparison were made to determine the harmonization of dose assessment results among the assessors. Materials and Methods: Seven cases on internal exposures incidents that have occurred or may occur were prepared by referring to the intercomparison excercise scenario that NRC and IAEA have carried out. Based on this, 16 nuclear facilities concerned with internal exposure in Korea were asked to evaluate the scenarios. Each result was statistically determined according to the harmonization discrimination criteria developed by IDEAS/IAEA. Results and Discussion: The results were evaluated as having no outliers in all 7 cases. However, the distribution of the results was spread by various causes. They can be divided into two wide categories. The first one is the distribution of the results according to the assumption of the intake factors and the evaluation factors. The second one is distribution due to misapplication of calculation method and factors related to internal exposure. Conclusion: In order to satisfy the harmonization criteria and accuracy of the internal exposure dose evaluation, it is necessary that exact guidelines should be set on low dose, and various intercomparison cases also be needed including high dose exposure as well as the specialized education. The aim of the blind test is to make harmonization evaluation, but it will also contribute to securing the expertise and high quality of dose evaluation data through the discussion among the participants.

A Study on the Risk Assessment Method of Indoor-Impulsive Noise (실내 충격소음 위험 평가 방법에 관한 연구)

  • Chung, Sung Hak;Song, Ki Hyeok
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.2
    • /
    • pp.90-97
    • /
    • 2016
  • The objective of this study is to evaluate the operator's safety for the risk assessment method of impulsive noise division. Literature reviews on the basis of the impulsive noise study, the measuring methods and procedures, based on the results of the analysis process presents a risk assessment methods. In this study, analysis of the MIL-STD-1474D, B-duration graph for the peak noise level to cross the line from the measurement results is limited by the risk retracted. It is possible to determine whether there is quick can be determined whether the risk. Measurement positions measured by the microphone is installed on the risk of applying results are so located within the tolerance impulsive noise in the measurement position can interpret subjective safety is ensured. In addition, Proportional Dose technology was the proposed by the Patterson with the risk assessment method was applied to the indoor-impulsive noise. As results of this study, results for the same value of applying the technique of Proportional Dose technology results calculated by MIL-STD-1474D methods allows 1 count once increased in comparison to the result obtained.

INTERNATIONAL COLLABORATION IN ASSESSMENT OF RADIOLOGICAL IMPACTS ARISING FROM RELEASES TO THE BIOSPHERE AFTER DISPOSAL OF RADIOACTIVE WASTE INTO GEOLOGICAL REPOSITORIES

  • Smith, Graham;Kato, Tomoko
    • Nuclear Engineering and Technology
    • /
    • v.42 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • Geological disposal is designed to provide safe containment of radioactive waste for very long times, with the containment provided by a combination of engineered and geological barriers. In the extreme long term, after many thousands of years or longer, residual amounts of long-lived radionulides such as Cl-36, but also radionuclides in the natural decay chains, may be released into the environment normally accessed and used by humans, termed here, the biosphere. It is necessary to ensure that any such releases meet radiation protection objectives through the development of a safety case, which will include assessment of radiation doses to humans. The design of such dose calculations over such long timeframes is not straightforward, because of the range of potentially relevant assumptions which could be made, concerning environmental change and changes in human behavior. These conceptual uncertainties are additional to those that more typically arise, for example, in the assessment of present day situations, but which also have to be addressed. The issue has therefore been subject to international cooperation for many years. This paper summarizes the evolution and results of that collaboration leading up to the present day, taking account of developments in international recommendations on radiation protection objectives and the more recent greater focus on preparation of site specific safety cases.

Chromosome Aberration and Sister Chromatid Exchange for the Assessment of Cadmium Toxicity (카드뮴독성을 평가하기 위한 방법으로서의 염색체 이상 및 자매염색체 교환)

  • 맹승희;정해원
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.1
    • /
    • pp.110-119
    • /
    • 1991
  • This study was performed to investigate the applicability of 9 chromosome aberration and sister chromatid exchange analysis for the assessment of cytotoxicity and cytogenetic effects of cadmium. Induction of chromosome aberration and sister chromatid exchange in CHO-K1 cells and human peripheral lymphocytes by 2 hour-treatment of CdCl$_{2}$ with various concentrations was observed in relation to their frequencies and types of aberration. The frequency of chromosome aberration in CHO cells treated with CdCl$+{2}$ at G$_{1}$ was increased with dose-dependent manner. When human peripheral lymphocytes were treated with cadmium at G0 and harvested at 72 hours there after, the response was dose-dependent and all the aberrations were also chromatid types. There was no significant increase in frequencies of sister chromatid exchange in both CHO cells and human lymphocytes treated with different concentrations of cadmium. It was suggested that SCE analysis was not a good assessment method for cadmium toxicity.

  • PDF

Radiological Assessment of Environmental Impact of the IF-System Facility of the RAON

  • Lee, Cheol-Woo;Whang, Won Tae;Kim, Eun Han;Han, Moon Hee;Jeong, Hae Sun;Jeong, Sol;Lee, Sang-jin
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.2
    • /
    • pp.58-65
    • /
    • 2021
  • Background: The evaluation of skyshine distribution, release of airborne radioactive nuclides, and soil activation and groundwater migration were required for radiological assessment of the impact on the environment surrounding In-Flight (IF)-system facility of the RAON (Rare isotope Accelerator complex for ON-line experiment) accelerator complex. Materials and Methods: Monte Carlo simulation by MCNPX code was used for evaluation of skyshine and activation analysis for air and soil. The concentration model was applied in the estimation of the groundwater migration of radionuclides in soil. Results and Discussion: The skyshine dose rates at 1 km from the facility were evaluated as 1.62 × 10-3 μSv·hr-1. The annual releases of 3H and 14C were calculated as 9.62 × 10-5 mg and 1.19 × 10-1 mg, respectively. The concentrations of 3H and 22Na in drinking water were estimated as 1.22 × 10-1 Bq·cm-3 and 8.25 × 10-3 Bq·cm-3, respectively. Conclusion: Radiological assessment of environmental impact on the IF-facility of RAON was performed through evaluation of skyshine dose distribution, evaluation of annual emission of long-lived radionuclides in the air and estimation of soil activation and groundwater migration of radionuclides. As a result, much lower exposure than the limit value for the public, 1 mSv·yr-1, is expected during operation of the IF-facility.

Acute toxicity test and safety classification for Termitomyces albuminosus containing pharmacologically similar ingredient of Aconitum koreanum (백부자-대체 가능 한약재의 계종버섯에 대한 급성독성시험과 안전성등급화)

  • An, Minji;Park, Yeongchul
    • The Korea Journal of Herbology
    • /
    • v.32 no.4
    • /
    • pp.33-38
    • /
    • 2017
  • Objectives : Termitomyces albuminosus (Berk.) Heim is one of the famous wild edible mushrooms in the southern part of China. It is known that Termitomyces albuminosus, like Aconitum koreanum used in Korean traditional medicine, contains a kind of cerebroside, termitomycesphin, causing a pharmacologic effect on the neuron system. The pharmacologic effect of Termitomyces albuminosus can be used to possibly replace Aconitum koreanum. However, It needs to be certified as safe before it can be used. Here, a single-oral toxicity test and safety classification was conducted to obtain acute information of the toxicity of dried-Termitomyces albuminosus powder and to secure its safety in clinical applications. Methods : In order to calculate approximate lethal dose(ALD), test substance was orally administered to male and female SD-rat at dose levels of 5,000 and 0 (vehicle control) mg/kg (body weight). Based on the result of this toxicity, also the estimation of safety classification was calculated using the HED-based (human equivalent dose) MOS (margin of safety). Results : There were no mortalities, test substances treatment-related clinical signs, no changes in the body or organ weights, and no gross or histopathological findings at 14 days after treatment with test substance. Thus, the approximate lethal dose of dried-Termitomyces albuminosus powder was considered over 5,000 mg/kg in both female and male mice. Conclusions : Based on the limit dose, 5000 mg/kg, it was estimated that dried-Termitomyces albuminosus powder is classified as "Specified class B" indicating that clinical dose is not limited to patients as safe as food.

Analysis of Cosmic Radiation Exposure for Domestic Flight Crews in Korea

  • Ahn, Hee-Bok;Hwang, Junga;Kwak, Jaeyoung;Kim, Kyuwang
    • Journal of Astronomy and Space Sciences
    • /
    • v.39 no.2
    • /
    • pp.51-57
    • /
    • 2022
  • Cosmic radiation exposure of the flight crews in Korea has been managed by Radiation Safety Management around Living Life Act under Nuclear Safety and Security Commission. However, the domestic flight crews are excluded from the Act because of relatively low route dose exposure compared to that of international flight crews. But we found that the accumulated total annual dose of domestic flight crews is far from negligible because of relatively long total flight time and too many flights. In this study, to suggest the necessity of management of domestic flight crews' radiation exposure, we statistically analyzed domestic flight crew's accumulative annual dose by using cosmic radiation estimation models of the Civil Aviation Research Institute (CARI)-6M, Nowcast of Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS), and Korean Radiation Exposure Assessment Model (KREAM) and compared with in-situ measurements of Liulin-6K LET spectrometer. As a result, the average exposure dose of domestic flight crews was found to be 0.5-0.8 mSv. We also expect that our result might provide the basis to include the domestic flight crews as radiation workers, not just international flight attendants.