• Title/Summary/Keyword: dose assessment

Search Result 975, Processing Time 0.024 seconds

A Study on the Food Consumption Rates for Off-site Radiological Dose Assessment around Korean Nuclear Power Plants (국내 원자력발전소 주변 주민의 방사선량 평가를 위한 음식물 섭취율 설정 연구)

  • Lee, Gab-Bock;Chung, Yang-Geun
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.183-196
    • /
    • 2008
  • The internal dose by food consumption mostly accounts for radiological dose of public around nuclear power plants (NPPs). But, food consumption rates applied to off-site dose calculation in Korea which are the result of field investigation around Kori NPP by the KAERI (Korea Atomic Energy Research Institute) in 1988, are not able to reflect the latest dietary characteristics of Korean. The food consumption rates to be used for radiological dose assessment in Korea are based on the maximum individual of US NRC (Nuclear Regulatory Commssion) Regulatory Guide 1.109. However, the representative individual of the critical group is considered in the recent ICRP (International Commission on Radiological Protection) recommendation and European nations' practice. Therefore, the study on the re-establishment of the food consumption rates for individual around nuclear power plant sites in Korea was carried out to reflect on the recent change of the Korean dietary characteristics and to apply the representative individual of critical group to domestic regulations. The Ministry of Health and Welfare Affairs has investigated the food and nutrition of nations every 3 years based on the Law of National Health Improvement. The statistical data such as mean, standard deviation, various percentile values about food consumption rates to be used for the representative individual of the critical group were analyzed by using the raw data of the national food consumption survey in $2001{\sim}2002$. Also, the food consumption rates for maximum individual are re-estimated.

Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image (디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.275-283
    • /
    • 2013
  • The patient radiation dose is different depending on selection of Ion chamber when taking Chest PA which using AEC. In this paper, we studied acquiring the best diagnostic images according to selection of Ion chamber on AEC mode as well as minimizing patient radiation dose. Experimental methods were selection of Ion chamber and change of sensitivity under the same conditions as Chest PA projection. At AEC mode, two upper ion chambers sensors and one lower ion chamber sensor were divided into 7 cases according to selection of on/off. after measuring five times respectively, we obtained average value and calculated exposure dose. Image assessment was done with measured Modulation Transfer Function, Peak Signal to Noise Ratio, Root Mean Square, Signal to Noise Ratio, Contrast to Noise Ratio, Mean to Standard deviation Ratio respectively. In exposure assessment results, selection of two upper chambers was the lowest. In resolution assessment results, image of two upper chambers had the second high spatial frequency at sensitivity at 625(High) was 1.343 lp/mm. RMS value of image selecting two upper chambers was low secondly. SNR, CNR, MSR were the high value secondly. As the sensitivity was increased, radiation dose was decreased but better image could be obtained on image quality. In order to obtain the best medical images while minimizing the dose, usage of two upper ion chambers is considered to be clinically useful at sensitivity 625(High).

A study on the aquatic eco-risk assessment of antibiotics treated by radiation (방사선으로 처리된 항생물질의 수서 생태위해성 평가)

  • Kang, Seon-Hong;Chang, Jae-Goo;Ka, Soon-Kyu;Kim, Hyun-Young;Kim, Sang-Don;Lee, Myun-Joo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.373-381
    • /
    • 2012
  • Antibiotics have been issued recently in water environments because of potential impacts on ecosystem and public health. This study was aimed to investigating the degradation of antibiotics such as tetracycline, lincomycin, sulfamethazine and cephradine using gamma ray irradiation. And the toxicity before and after irradiation on antibiotics was tested in order to examine the aquatic eco-risk assessment by aquatic organisms. In addition, comparing tests on toxicity for gamma ray and UV irradiated antibiotics was conducted. Four different antibiotics were prepared by concentration of 30 mg/L with demi-water respectively. The absorption dose of gamma ray was ranged from 0.2 to 2 kGy. The concentration of four antibiotics was gradually decreased corresponding to the increase of the absorption dose. A method for toxicity assessment using Pseudokirchneriella subcapitata was evaluated to the most acceptable compared with methods by Daphnia magna and Microtox$^{(R)}$ in terms of sensibility. It showed that the reduction of toxicity on antibiotics treated by gamma ray was superior comparing to the test results obtained from UV treatment. By-products from antibiotics treated by gamma ray were easily decomposed by microorganism and their toxicity was also evaluated to low.

Genotoxicity Study of Glycopeptide (G-7%NANA)

  • Kim, Ha-Young;Kim, Min-Hee;Kim, Hee-Kyong;Park, Yeong-Chul
    • Toxicological Research
    • /
    • v.34 no.3
    • /
    • pp.259-266
    • /
    • 2018
  • Glycomacropeptide (GMP), a whey protein of milk, has functions including differentiation and development of nervous system, and anticancer and antiviral effects. To develop new functions, N-acetylneuraminic acid (NANA) containing 7% sialic acid was separated from GMP to produce G-7%NANA. N-glycolylneuraminic acid (Neu5Gc) is another type of sialic acid separated from GMP, which has been linked to immune disorders and chronic inflammation-mediated diseases. Therefore, safety was a concern in the use of G-7%NANA in functional foods. To ensure safety, in this study, three genetic toxicity tests on G-7%NANA were conducted. In the reverse mutation test using Salmonella typhimurium TA98, TA100, TA1535, TA1537, and Escherichia coli WP2uvrA, and in the chromosome aberration test using CHO-K1 cells, no significant differences from negative control were found at all dose levels. Similarly, no dose-related differences were evident compared to negative control in the micronucleus test using ICR mice. There was no evidence of G-7%NANA-related genetic toxicity.

Uncertainty analysis of containment dose rate for core damage assessment in nuclear power plants

  • Wu, Guohua;Tong, Jiejuan;Gao, Yan;Zhang, Liguo;Zhao, Yunfei
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.673-682
    • /
    • 2018
  • One of the most widely used methods to estimate core damage during a nuclear power plant accident is containment radiation measurement. The evolution of severe accidents is extremely complex, leading to uncertainty in the containment dose rate (CDR). Therefore, it is difficult to accurately determine core damage. This study proposes to conduct uncertainty analysis of CDR for core damage assessment. First, based on source term estimation, the Monte Carlo (MC) and point-kernel integration methods were used to estimate the probability density function of the CDR under different extents of core damage in accident scenarios with late containment failure. Second, the results were verified by comparing the results of both methods. The point-kernel integration method results were more dispersed than the MC results, and the MC method was used for both quantitative and qualitative analyses. Quantitative analysis indicated a linear relationship, rather than the expected proportional relationship, between the CDR and core damage fraction. The CDR distribution obeyed a logarithmic normal distribution in accidents with a small break in containment, but not in accidents with a large break in containment. A possible application of our analysis is a real-time core damage estimation program based on the CDR.