• Title/Summary/Keyword: doppler effect

Search Result 471, Processing Time 0.033 seconds

Comparison of Wind Vectors Derived from GK2A with Aeolus/ALADIN (위성기반 GK2A의 대기운동벡터와 Aeolus/ALADIN 바람 비교)

  • Shin, Hyemin;Ahn, Myoung-Hwan;KIM, Jisoo;Lee, Sihye;Lee, Byung-Il
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1631-1645
    • /
    • 2021
  • This research aims to provide the characteristics of the world's first active lidar sensor Atmospheric Laser Doppler Instrument (ALADIN) wind data and Geostationary Korea Multi Purpose Satellite 2A (GK2A) Atmospheric Motion Vector (AMV) data by comparing two wind data. As a result of comparing the data from September 2019 to August 1, 2020, The total number of collocated data for the AMV (using IR channel) and Mie channel ALADIN data is 177,681 which gives the Root Mean Square Error (RMSE) of 3.73 m/s and the correlation coefficient is 0.98. For a more detailed analysis, Comparison result considering altitude and latitude, the Normalized Root Mean Squared Error (NRMSE) is 0.2-0.3 at most latitude bands. However, the upper and middle layers in the lower latitudes and the lower layer in the southern hemispheric are larger than 0.4 at specific latitudes. These results are the same for the water vapor channel and the visible channel regardless of the season, and the channel-specific and seasonal characteristics do not appear prominently. Furthermore, as a result of analyzing the distribution of clouds in the latitude band with a large difference between the two wind data, Cirrus or cumulus clouds, which can lower the accuracy of height assignment of AMV, are distributed more than at other latitude bands. Accordingly, it is suggested that ALADIN wind data in the southern hemisphere and low latitude band, where the error of the AMV is large, can have a positive effect on the numerical forecast model.

Error Budget Analysis for Geolocation Accuracy of High Resolution SAR Satellite Imagery (고해상도 SAR 영상의 기하 위치정확도 관련 중요변수 분석)

  • Hong, Seung Hwan;Sohn, Hong Gyoo;Kim, Sang Pil;Jang, Hyo Seon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.6_1
    • /
    • pp.447-454
    • /
    • 2013
  • The geolocation accuracy of SAR satellite imagery is affected by orbit and sensor information and external variables such as DEM accuracy and atmospheric delay. To predict geolocation accuracy of KOMPSAT-5 and KOMPSAT-6, this paper uses TerraSAR-X imagery which has similar spec. Simulation data for sensitivity analysis are generated using range equation and doppler equation with several key error sources. As a result of simulation analysis, the effect of sensor information error is larger than orbit information error. Especially, onboard electronic delay needs to be monitored periodically because this error affects geolocation accuracy of slant range direction by 30m. Additionally, DEM accuracy causes geolocation error by 20~30m in mountainous area and atmospheric delay can occur by 5m in response to atmospheric condition and incidence angle.

Investigation of Various Radiation Proton Energy Effect on n, p Type Silicon by Positron Annihilation Method (양전자 소멸 측정법으로 양성자 조사에너지 변화에 대한 n, p형 실리콘 구조 특성)

  • Lee, Chong Yong
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.6
    • /
    • pp.341-347
    • /
    • 2013
  • The n-type and p-type silicon samples were exposed by 40.0, 3.98 MeV proton beams ranging between 0 to $20.0{\times}10^{13}protons/cm^2$. Coincidence Doppler Broadening Positron Annihilation Spectroscopy (CDBPAS) were applied to study of defect characteristics of p type and n type silicon samples. In this investigation the numerical analysis of the spectra was employed to the determination of the shape parameter, S, defined as the ratio between the amount of counts in a central portion of the gamma spectrum and the total counts of whole gamma spectrum. The S-parameter values strongly depend on the irradiated proton beam that indicated the defects generate more, rather than the energy intensity. 40 MeV irradiated proton beam in the n-type silicon at $20.0{\times}10^{13}protons/cm^2$ was larger defects than 3.98 MeV irradiated proton beam. It was analysis between the proton irradiation beams and the proton intensities of the irradiation. Because of the Bragg peak, SRIM results shows mainly in a certain depth of the sample to form the defect by the proton irradiation, rather than the defects to appear for the entire sample.

Development of Velocity Imaging Method for Motility of Left Ventricle in Gated SPECT (게이트 심근 SPECT에서 좌심실의 운동성 분석을 위한 속도영상화 기법 개발)

  • Jo, Mi-Jung;Lee, Byeong-Il;Choi, Hyun-Ju;Hwang, Hae-Gil;Choi, Heung-Kook
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.7
    • /
    • pp.808-817
    • /
    • 2006
  • Although the generally used the velocity index of doppler effect is a very significant factor in the functional evaluation of the left ventricle, it depends on the subjective evaluation of an inspector. The objective data of the motility can be obtained from the gated myocardial SPECT images by quantitative analysis. However, it is difficult to image visual of the velocity of the motion. The aim of our study is to develop a new method for the imaging velocity using the gated myocardial SPECT images and use it as an evaluation index for analyzing motility. First we visualized left ventricle into 3 dimensions using the coordinates of the points which were obtained through a segmentation of myocardium. Each point was represented by the different colors, according to the velocity of each point. We performed a validation study using 7 normal subjects and 15 myocardial infarction patients. To analyze motility, we used the average of the moved distance and the velocity. In normal cases, the average of the moved distance was 4.3mm and the average of the velocity was 11.9mm. In patient cases, the average of the moved distance was 3.9mm and the average of the velocity was 10.5mm. These results show that the motility of normal subjects is higher than the abnormal subjects. We expect that our proposed method could become a way to improve the accuracy and reproducibility for the functional evaluation of myocardial wall.

  • PDF

Noise Analysis and Measurement for a CW Bio-Radar System for Non-Contact Measurement of Heart and Respiration Rate (호흡 및 심박수 측정을 위한 비접촉 방식의 CW 바이오 레이더 시스템의 잡음 분석 및 측정)

  • Jang, Byung-Jun;Yook, Jong-Gwan;Na, Won;Lee, Moon-Que
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.1010-1019
    • /
    • 2008
  • In this paper, we present a noise analysis and measurement results of a bio-radar system that can detect human heartbeat and respiration signals. The noise analysis including various phase noise effects is very important in designing the bio-radar system, since the frequency difference between the received signal and local oscillator is very small and the received power is very low. All of the noise components in a bio-radar system are considered from the point of view of SNR. From this analysis, it can be concluded that the phase noise due to antenna leakage is a dominant factor and is a function of range correlation. Therefore, the phase noise component with range correlation effect, which is the most important noise contribution, is measured using the measurement setup and compared with the calculated results. From the measurement results, our measurement setup can measure a closed-in phase noise of a free-running oscillator. Based on these results, it is possible to design a 2.4 GHz bio-radar system quantitatively which has a detection range of 50 cm and low power of 1 mW without additional PLL circuits.

Effects of Uwhangchungsim-won(Niuhuangqingxin-yuan) on Systemic Blood Pressure, Pulse Rate, Cerebral Blood Flow, and Cerebrovascular Reactivity in Humans (우황청심원(牛黃淸心元)이 정상인의 혈압(血壓), 맥박수(脈搏數), 뇌혈류(腦血流) 및 뇌혈관반응도(腦血管反應度)에 미치는 영향(影響))

  • Yun, Sang-Pil;Lee, Sang-Ho;Kim, Eun-Ju;Na, Byong-Jo;Jung, Dong-Won;Shin, Won-Jun;Moon, Sang-Kwan;Bae, Hyung-Sup;Kim, Lee-Dong
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.3
    • /
    • pp.440-450
    • /
    • 2004
  • Objectives: Uwhangchungsim-won(UC) has been used in the treatment of a wide variety of conditions including stroke, hypertension, arterosclerosis, autonomic imbalance, and mental instability, in Korean traditional hospitals. The aim of this study was to evaluate the effect of DC on cerebral hemodynamics and to determine the appropriate dosage. Methods: We studied changes in hyperventilation-induced cerebrovascular reactivity and mean blood flow velocity of the middle cerebral arteries(MCAs) were studied by means of transcranial Doppler ultrasound. Changes in mean blood pressure, pulse rate and expiratory CO2(PECO2) were observed using Cardiocap TM/5. Six healthy young volunteers who were administrated with full doses of DC for group A, and half doses for group B. Six other healthy subjects comprised the control group. The evaluation was performed during basal condition, and repeated at 20, 40, 60, 120, and 180 minutes after administration. Results: Increases of cerebrovascular reactivity and mean blood flow velocity in the middle cerebral artery in group A were significantly different compared with group B and the control group (p<0.1). Mean blood pressure, pulse rate and expiratory CO2 did not change during the observation and were not different among these three groups. We observed that in cerebrovascular reactivity induced hyperventilation, group A was most effective at 40 minutes after administration, and its effectiveness lasted for 120 minutes. Conclusions: This study provides evidence for UC, in full doses, as an agent for dilation of the cerebral arteriols to increase hyperventilation-induced cerebrovascular reactivity as a consequence of faster recovery of blood flow velocity.

  • PDF

Effect of Interference in CSMA/CA Based MAC Protocol for Underwater Network (CSMA/CA 기반 수중 통신망에서 간섭의 영향 연구)

  • Song, Min-je;Cho, Ho-shin;Jang, Youn-seon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.8
    • /
    • pp.1631-1636
    • /
    • 2015
  • With the advance of wireless communication technology in terrestrial area, underwater communication is also evolving very fast from a simple point-to-point transmission to an elaborate networked communications. Underwater acoustic channel has quite different features comparing with the terrestrial radio channel in terms of propagation delay, Doppler shift, multipath, and path loss. Thus, existing technologies developed for terrestrial communication might not work properly in underwater channel. Especially medium access control (MAC) protocols which highly depend on propagation phenomenon should be newly designed for underwater network. CSMA/CA has drawn lots of attention as a candidate of underwater MAC protocol, since it is able to resolve a packet collision and the hidden node problem. However, a received signal could be degraded by the interferences from the nodes locating outside the receiver's propagation radius. In this paper, we study the effects of interference on the CSMA/CA based underwater network. We derived the SNR with the interference using the sonar equation and analyzed the degradation of the RTS/CTS effects. These results are compared with the terrestrial results to understand the differences. Finally we summarized the design considerations in CSMA/CA based underwater network.

The Effect of Botulinum Toxin-A on the Survival of Random-Pattern Cutaneous Flap in Rat (보튤리눔 톡신-A가 백서의 임의 피판 생존율에 미치는 영향)

  • Kim, Young Seok;Lee, Chae Su;Yoo, Won Min;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.360-366
    • /
    • 2008
  • Purpose: Botulinum toxin type A(BoTA) can block the release of vasoconstriction cotransmitters as well as acetylcholine in nerve terminal. The authors observed that BoTA increases flap survival by preventing sympathetic collapse of peripheral vessels. Methods: 10 Sprague Dawley rats were divided into control(n=5), and BoTA group(n=5). $3{\times}10cm$ sized random pattern cutaneous flaps were elevated on the dorsal side in both groups. In BoTA group, BoTA was injected into the flap via intradermal to subdermal route, 7 days before the flap elevation. Flap survival rates (survival area/total area) were measured 7 days after the elevation. Cutaneous blood flow was measured in proximal, middle and distal compartments of the flap using laser Doppler flowmetry initially, preoperatively, at immediate postoperation, and 7 days after flap elevation, respectively. Histological examination was performed 7 days after the flap elevation. The number and shape of the vessels were evaluated under microscope. Results: Mean flap survival was $53.18{\pm}6.58%$ in control group and $93.79{\pm}6.06%$ in BoTA group, displaying statistically significant difference(p=0.0008, p<0.05). In the control group, blood flow to the middle and distal compartments of the flap decreased significantly immediately after flap elevation. In the BoTA group, blood flow to the middle compartment did not decrease(p=0.002) and slightly decreased in the distal compartment(p=0.001). Cutaneous blood flow was significantly higher in all compartments of the flap in BoTA group than in control group, 7 days after the flap elevation. In histopathologic examination, greater number of vessels were noted in the BoTA group than in the control group. Conclusion: Botulinum toxin A can increase the survival of the random pattern cutaneous flap in rats by preventing the sympathetic collapse of peripheral vessels.

A Study on the Correlation Results for Fringe Rotation and Delay Tracking of the VCS (VCS의 지연추적과 프린지 회전에 대한 상관결과 고찰)

  • Oh, Se-Jin;Yeom, Jae-Hwan;Roh, Duk-Gyoo;Oh, ChungSik;Jung, Jin-Seung;Chung, Dong-Kyu;Oyama, Tomoaki;Kawaguchi, Noriyuki;Kobayashi, Hideyuki;Kono, Yusuke;Ozeki, Kensuke;Onuki, Hirohumi
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.4
    • /
    • pp.220-232
    • /
    • 2012
  • In this paper, we investigate the correlation result due to the problems of delay tracking and fringe rotation module in the VCS(VLBI Correlation Subsystem). The VCS, FX-type correlator, adopts the delay tracking and fringe rotation module in order to compensate the delay change and fringe phase of wave signal from the radio source by Doppler's effect. The phase of observed data is also compensated by means of delay tracking and fringe rotation in the correlator, but we confirmed that the phase is unstable by applying long integration period of AIPS(Astronomical Image Processing System) rather than correlator. And the delay value of observed data has the errors of several tens nanoseconds than normal case at the analysis of correlation result. In addition, we found that the phase of correlation results is not connected as the unit of FFT-segment because the initial fringe phase at the fringe rotation module is not correctly determined. In this paper, in order to solve these problems, the original direction of 90 degree phase jump is reversely modified when the bit-shift occurred at the delay tracking. And the initial fringe phase at the fringe rotation module is correctly modified by using the initial phase of observed data. In addition, the parameter calculation module was abnormally operated as designed in the fringe rotation. So, the logical program by the VCS is modified so as to calculate the parameters correctly. Through the experiments of correlation processing over the above problems, the modified proposal algorithm is adequately corrected to the data analysis results, so that the experimental results make it clear for us to operate the developed VCS hardware correlator normally.

Study on the Projectile Velocity Measurement Using Eddy Current Probe (와전류 탐촉자를 이용한 총구 탄속 측정에 관한 연구)

  • Shin, Jungoo;Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.3
    • /
    • pp.83-86
    • /
    • 2015
  • Nowadays the weapon systems are employed air bursting munition (ABM) as smart programmable 40 mm shells which have been developed in order to hit the target with programmed munition that can be air burst after a set distance in the battlefield. In order to improve the accuracy of such a bursting time, by measuring the speed of the munition from the barrel, weapon systems calculate the exact time of flight to the target and then the time information must be inputted to the munition. In this study, we introduce a device capable of detecting a shot at K4 40 mm automatic grenade. The shot is composed of a rotating copper band to convert linear motion into rotary motion when it passes through the barrel, the steel section is exert the effect of fragment and aluminum section to give fuze information. The aluminum section was used to detect munition using eddy current method. To measure muzzle velocity by means of non-contact method, two eddy current probes separated 10 cm was employed. Time interval between two eddy current probe detection times was used as muzzle velocity. The eddy current probe was fabricated U-shape Mn-Zn ferrite core with enamelled copper wire, and 200 kHz alternating current was used to detect inductance change. Measured muzzle velocity using the developed sensor was compared to the Doppler radar system. The difference was smaller than 1%.