DC Link단 단일 전류센서에 의한 브러시리스 직류 전동기의 토크 리플 저감 (Torque Ripple Reduction of BLDG Motors Using Single DC-Link Currant Sensor)

  • 백대진;원창희;이교범;최익;송중호;유지윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.974-976
    • /
    • 2001
  • This paper presents a method to reduce commutation torque ripples occurred during commutation in brushless do motor drives using a single DC-link current sensor. In brushless dc motor drives with a single dc current sensor instead of 3-phase line current sensors, it is noted that dc-link current sensor cannot give any information corresponding to the motor currents during line current commutation intervals. A new technique to resolve such a problem is dealt with based on a deadbeat current control in which motor armature voltage command is computed from a dc-link current reference, an actual current and counter emf voltage. The simulation results show that the proposed method reduces the torque ripple significantly.

  • PDF

A Commutation Torque Ripple Reduction for Brushless DC Motor Drives

  • Won, Chang-hee;Song, Joong-Ho;Ick Choy
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제2B권4호
    • /
    • pp.174-182
    • /
    • 2002
  • This paper presents a comprehensive study on reducing commutation torque ripples generated in brushless DC motor drives with only a single do-link current sensor provided. In such drives, commutation torque ripple suppression techniques that are practically effective in low speed as well as high speed regions are scarcely found. The commutation compensation technique proposed here is based on a strategy that the current slopes of the incoming and the outgoing phases during the commutation interval can be equalized by a proper duty-ratio control. Being directly linked with deadbeat current control scheme, the proposed control method accomplishes suppression of the spikes and dips superimposed on the current and torque responses during the commutation intervals of the inverter. Effectiveness of the proposed control method is verified through simulations and experiments.

Novel SRM Drive Systems Using Variable DC-Link Voltage

  • Jang, Do-Hyun
    • Journal of Power Electronics
    • /
    • 제11권3호
    • /
    • pp.285-293
    • /
    • 2011
  • This paper proposes two SRM driving systems using a variable dc-link voltage controlled by a single-phase inverter. Two SRM converter topologies of a half bridge type and a full bridge type are proposed according to the power circuits of an inverter. The phase current can be controlled by means of a PWM controller at the inverter, and the turn-on/off angle at the phase switches can be controlled by a position sensor at the converter in the drive system. The inverter acts as a peak-current limiter if the transient current exceeds its maximum value. SRMs using the proposed topologies maintain high efficiency due to energy regeneration after the turn-off of power switches. The operational modes of the proposed topologies are verified by simulation and experimental results.

단일 전류 센서를 이용한 2상 하프브릿지 인버터의 상전류 측정 방법 (A Novel Current Measurement Method for Two-Phase Half-bridge Inverter using Single Current Sensor)

  • 조영훈;목형수;장도현;김상훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.193-195
    • /
    • 2007
  • This paper proposed a novel current measurement method for two-phase half-bridge inverter using single current sensor. The proposed method measures DC link input current and a phase current simultaneously and reconstructs each phase currents by simple calculation according to voltage vector. The commutation modes of two-phase half-bridge inverter is analized. The current sampling and reconstructing method is also presented. The proposed method is verified through simulation and experimental results on two-phase induction motor drive system.

  • PDF

교류 전동기의 고효율 운전을 위한 3상 인버터의 입력전력 추정 기법 (Input Power Estimation Method of a Three-phase Inverter for High Efficiency Operation of an AC Motor)

  • 김도현;김상훈
    • 전력전자학회논문지
    • /
    • 제24권6호
    • /
    • pp.445-451
    • /
    • 2019
  • An input power estimation method of a three-phase inverter for the high-efficiency operation of AC motors is proposed. Measuring devices, such as DC link voltage and input current sensors, are required to obtain the input power of the inverter. In the proposed method, the input power of the inverter can be estimated without the input current sensor by using the phase current information of the AC motor and the switching pattern of the inverter. The proposed method is more robust to parameter error than conventional method. The validity of the input power estimation method is verified through experiments conducted on a 1 kW permanent-magnet synchronous motor drive system.

무선 센서 네트워크에서의 비트맵 브로드캐스팅 라우팅 알고리즘 (A routing Algorithm by Broadcasting a Bitmap in Wireless Sensor Networks)

  • 정상준
    • 한국통신학회논문지
    • /
    • 제31권5A호
    • /
    • pp.459-468
    • /
    • 2006
  • 현재의 센서 네트워크에서의 라우팅은 센서 노드의 한정된 에너지를 고려하여 네트워크의 유지를 최대화하기 위한 방향으로 라우팅 경로를 설정하고 있다. 기존의 라우팅 알고리즘은 센서 노드의 한정된 자원과 이동성을 지원하기 위해 라우팅 테이블을 가지지 않고 라우팅이 이루어질 때마다 라우팅 경로를 찾아 주어진 경로로 라우팅을 수행하는 방법을 사용하고 있다. 센서 네트워크에서 베이스 스테이션 기능을 가지는 싱크 노드는 이동성을 보장 받지만 센서 노드 자체는 비이동성을 가정하는 경우가 일반적이다. 따라서 한정된 자원 내에서 라우팅을 수행하도록 라우팅 테이블의 크기를 최소화하는 방안이 제시된다면 새로운 라우팅 기법을 고려해 볼 수 있다. 본 논문은 라우팅 테이블의 크기를 최소화하는 방법으로, 비트맵을 구성하여 라우팅을 수행하는 새로운 라우팅 알고리즘을 제안한다. 각 노드는 이웃 노드와의 연결 정보를 비트로 표현하여 비트맵을 구성하는데, 전송에 필요로 하는 에너지를 최소화 하도록 이웃 노드에게 단 한번의 브로드캐스트를 수행한다. 그 결과, 모든 노드의 전체 네트워크의 링크 정보를 가지는 것이 아니라 부분적인 링크 정보를 가지게 된다. 링크 정보는 싱크 노드에 의해 만들어지므로, 부분적인 네트워크 연결 정보이지만 각 노드는 싱크 노드로 보고될 경로를 가질 수 있게 된다. 단 한번의 브로드캐스트이므로 메시지 전송 횟수를 최소할 수 있다. 즉, 센서 노드에서 메시지를 전송할 때 가장 많은 에너지를 소모하게 되는데, 경로 설정에 필요한 에너지를 줄이는 것은 노드가 가지는 한정된 에너지의 소모를 줄일수 있게 되어 네트워크의 생존 시간을 늘릴 수 있다는 것을 의미한다. 제안하는 라우팅 알고리즘은 기존의 라우팅 알고리즘에 비해 10% 정도의 메시지 전송 횟수를 줄일 수 있다.