• 제목/요약/키워드: divided electrodes

검색결과 66건 처리시간 0.022초

Electromyographic Analysis of Upper and Lower Limb Muscles during Gardening Tasks

  • Park, Sin-Ae;Lee, A-Young;Kim, Jai-Jeong;Lee, Kwan-Suk;So, Jae-Moo;Son, Ki-Cheol
    • 원예과학기술지
    • /
    • 제32권5호
    • /
    • pp.710-720
    • /
    • 2014
  • Movements of the upper and lower limb muscles during five common gardening tasks were analyzed by using electromyography (EMG). Twenty adults aged in their twenties (mean age, $24.8{\pm}2.4$ years) were recruited. On two separate occasions, subjects visited a garden plot to perform digging, raking, troweling, weeding, and hoeing; all tasks were performed three times with 20 s intervals for each trial. To measure muscle activation during the five gardening tasks, surface EMG was used. Bipolar surface EMG electrodes were attached to eight upper limb muscles (bilateral anterior deltoid, biceps brachialis, brachioradialis, and flexor carpi ulnaris) or eight lower limb muscles (bilateral vastus lateralis, vastus medialis, biceps femoris, and gastrocnemius) on both sides of the body, for a total of 16 muscles. During the five tasks, photographs were taken of movement phases using a digital video camera. The right flexor carpi ulnaris and brachioradialis showed higher activation than the other upper and lower limb muscles measured during the tasks. All 16 upper and lower limb muscles were actively used only during digging. According to movement analysis of each activity, digging was classified into four movement phases, whereas raking, troweling, weeding, and hoeing each were divided into three movement phases. In each activity, there were high-impact phases in terms of muscle activation; the flexor carpi ulnaris and brachioradialis were identified as major muscles in each impact phase. This analysis may be used to generate biomechanical profiles of gardening tasks for practitioners when designing efficient gardening interventions for physical health or rehabilitation.

미소 전류 자극이 TPS-IMZ 임프란트 주위의 골유착과 골형성에 미치는 영향 (DIRECT CURRENT EFFECT ON THE BONE FORMATION AND OSSEOINTEGRATION AROUND TPS-IMZ IMPLANT)

  • 박상원;양홍서
    • 대한치과보철학회지
    • /
    • 제34권4호
    • /
    • pp.722-745
    • /
    • 1996
  • The purpose of this study is to investigate the effect of constant direct current electrical stimulation in healing the bone defects and surrounding tissues of the endo-oseous(TPS-IMZ) implants. Implants were inserted in the femur of adult dogs. Then a constrant direct current of approximately $10{\mu}A$ was applied. Artificial bone defects were prepared on one side of the implant site. Experimental groups were divided into 4 : control group : bone defect without treatment group I : bone defect filled with hydroxyapatite powders group II : bone defect, in which a negative and positive electrodes were inserted 5mm apart from both sides of the implant group III : bone defect, in which negative current was directly connected to the IMZ implant and a positive electrode was placed 10mm apart from the implant The animals were sacrificed in the 1st, 2nd, 4th and 8th week after implantation for the light microscopic examination. The results obtained were as follows : 1. In electrically stimulated experimental groups, new bone formation and osseointegration around implants were accelerated. 2. Group III showed the greatest activity in new bone formation. Osteoconductivity around HA particles was observed in group 1. 3. The defect area of the control group was healed by forming new bone, which grew from the underlying cancellous bone. The defect areas of the electrically stimulated experimental groups were healed by newly formed bone, which grew upward from the cancellous bone and downward from the periosteum. 4. 8 weeks after implantation, all the groups showed good osseointegration between the surrounding bone and implants.

  • PDF

Reduction of Gamma Distortion in Oblique Viewing Directions in Polymer-stabilized Vertical Alignment Liquid Crystal Mode

  • Kim, Hyo Joong;Lim, Young Jin;Murali, G.;Kim, Min Su;Kim, Gi Heon;Kim, Yong Hae;Lee, Gi-Dong;Lee, Seung Hee
    • Current Optics and Photonics
    • /
    • 제1권2호
    • /
    • pp.157-162
    • /
    • 2017
  • In large liquid crystal displays, the image quality in an oblique viewing direction is a crucial issue. From this perspective, 8-domain polymer-stabilized vertical alignment (PS-VA) mode has been developed to suppress the color shift in oblique viewing directions, compared to that in 4-domain PS-VA mode. To realize the 8-domain PS-VA, the four domains in a pixel are each divided into two regions, such that applying different electric potentials result in different tilt angles in these two regions, while keeping four azimuthal directions in each domain. However, applying different voltages in a pixel causes drawbacks, such as requiring additional processes to construct a capacitor and a transistor, which will further reduce the aperture ratio. Here we propose a different approach to form the 8-domain, by controlling surface polar anchoring energy and the width of patterned electrodes in two regions of a pixel. As a result, the gamma-distortion index (GDI), measured at an azimuthal angle of $0^{\circ}$, is reduced by about 23% and 8%, compared to that of a conventional 4-domain at polar angles of $30^{\circ}$ and $60^{\circ}$ respectively.

수처리용 다중 유전체 방벽 방전 플라즈마 반응기 개발 (Development of Multi Dielectric Barrier Discharge Plasma Reactor for Water Treatment)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제22권7호
    • /
    • pp.863-871
    • /
    • 2013
  • Dielectric discharges are an emerging technique in environmental pollutant degradation, which that are characterized by the production of hydroxyl radicals as the primary degradation species. For practical application of the plasma reactor, reactor that can handle large amounts of water are needed. Plasma research to date has focused on small-scale water treatment. This study was carried out basic study for scale-up of a single DBD (dielectric barrier discharge) plasma reactor. The degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) was used as a performance indicator of multi-plasma reactor. The experiments is divided into two parts: design parameters [effect of distance of single plasma module (1~14 cm), arrangement of ground electrode (single and multi), rector number (1~5) and power number (1~5)]; operation parameter [effect of applied voltage (60~220 V), air flow rate (1~5 L/min), electric conductivity of solution ($1.4{\mu}S/cm$, deionized water)~18.8 mS/cm (addition of NaCl 10 g/L) and pH (5~9)]. Considering the electric stability of the plasma reactor, optimum spacing between the single plasma module was 2 cm. Multi discharge electrodes - single ground electrode array was selected. Combination of power 3-plasma module 5 was the optimal combination for maximum RNO degradation. The optimum 1st voltage and air flow rate for RNO degradation were 180 V and 4 L/min, respectively. The pH and conductivity of the solution was not influencing the RNO degradation.

Fabrication and Vibration Characterization of a Partially Etched-type Artificial Basilar Membrane

  • Kang, Hanmi;Jung, Youngdo;Kwak, Jun-Hyuk;Song, Kyungjun;Kong, Seong Ho;Hur, Shin
    • 센서학회지
    • /
    • 제24권6호
    • /
    • pp.373-378
    • /
    • 2015
  • The structure of the human ear is divided into the outer ear, the middle ear, and the inner ear. The inner ear includes the cochlea that plays a very important role in hearing. Recently, the development of an artificial cochlear device for the hearing impaired with cochlear damage has been actively researched. Research has been carried out on the biomimetic piezoelectric thin film ABM (Artificial Basilar Membrane) in particular. In an effort to improve the frequency separation performance of the existing piezoelectric thin film ABM, this paper presents the design, fabrication, and characterization of the production and performance of a partially etched-type ABM material. $O_2$ plasma etching equipment was used to partially etch a piezoelectric thin film ABM to make it more flexible. The mechanical-behavior characterization of the manufactured partially etched-type ABM showed that the overall separation frequency range shifted to a lower frequency range more suitable for audible frequency bandwidths and it displayed an improved frequency separation performance. In addition, the maximum magnitude of the vibration displacement at the first local resonant frequency was enhanced by three times from 38 nm to 112 nm. It is expected that the newly designed, partially etched-type ABM will improve the issue of cross-talk between nearby electrodes and that the manufactured partially etched-type ABM will be utilized for next-generation ABM research.

The Effect of Acupuncture on Relieving Pain after Inguinal Surgeries

  • Taghavi, Rahim;Tabasi, Kamyar Tavakoli;Mogharabian, Nasser;Asadpour, Akram;Golchian, Amir;Mohamadi, Shabnam;Kabiri, Azade Ataran
    • The Korean Journal of Pain
    • /
    • 제26권1호
    • /
    • pp.46-50
    • /
    • 2013
  • Background: Postoperative pain is one of the most prevalent and bothersome issues found in the surgical department. Nowadays, there are various methods of acupuncture used for relieving pain without the complications found in some routine postoperative analgesics. These methods could be especially useful for high risk patients prone to complications from analgesics, such as transplantation recipients. The aim of this study was to evaluate the efficacy of electro-acupuncture on postoperative pain control after inguinal surgeries. Methods: Ninety male patients, who were referred to our department with indications of inguinal surgery, were included in the study and randomly divided into two groups, such as acupuncture and control. We used electro-acupuncture for the acupuncture group and no actual acupuncture (but placed needle electrodes similar to the acupuncture group) for the control group. Postoperative pain was quantified by a blind observer in both groups using a visual analogue scale (VAS) standard score before being compared. Results: Pain intensity and analgesic use were significantly higher in the control group (P < 0.05). In the acupuncture group, the VAS pain scores were significantly lower than the control group at 0.5, 1 and 2 hours post operation. When the opioid related side effects were compared for each group, the results showed that the number of subjects who experienced dizziness in the acupuncture group was significantly lower than the control group (P < 0.05). Conclusions: Acupuncture in patients, after inguinal surgery, can reduce the need of analgesics, which also directly reduces the complications that may occur when analgesics are used in relieving pain postoperatively.

재료물성 측정을 위한 직선집속 PVDF 초음파 트랜스듀서의 새로운 설계 및 응용 (New Design and Application of PVDF Ultrasonic Transducer for Measurement of Material Properties)

  • 홍성욱;김정순;김상윤;김무준;하강렬
    • 한국음향학회지
    • /
    • 제25권4호
    • /
    • pp.164-171
    • /
    • 2006
  • 임의의 등방성재료에 대한 종파, 횡파 및 누설표면파의 음속을 알면 해석적으로 그 재료의 탄성정수와 밀도를 산출할 수 있다. 종래, 그 음속들은 각각 다른 진동모드를 갖는 세 개의 초음파 트랜스듀서에 의해 측정되어져 왔다. 본 연구에서는 하나의 트랜스듀서에 의해 그 세 가지 파의 개략적인 음속을 동시에 측정하기위한 전극분할형 PVDF 직선집속 초음파 트랜스듀서를 새로이 제안하고, 설계, 제작하였다. 그리고 그것에 의한 각 파의 음속측정 방법을 확립한 후, 용융석영 등 몇몇 등방성재료에 적용하였다. 또한, 측정된 각 파의 음속을 이용하여 탄성 강성정수 및 밀도를 산출하고, 각 값들의 오차를 검토하였는데, 얻어진 값들은 문헌치와 비교적 잘 일치함을 알 수 있었다.

전기자극과 vitamin AD3E가 랫드 골절치유에 미치는 영향 (Effect of electrical stimulation and vitamin AD3E on fracture healing in a rat model)

  • 배춘식;조용성;장경진
    • 대한수의학회지
    • /
    • 제37권4호
    • /
    • pp.863-873
    • /
    • 1997
  • Electrical stimulation and vitamin $AD_3E$ administration have been shown to enhance the repair of biological tissues such as bone, ligament and tendon, The objective of this study were (a) to investgate the therapeutic effects of different levels of electrical stimulation and vitamin $AD_3E$ administration on fracture healing in a rat model and (b) to identify the most effective voltage level. Ninety Sprague-dawley rats were divided into electrical stimulation group and vitamin $AD_3E$ administration group. Electricla stimulation group was divided into four groups on the basis of the level of current delivered. The experimental groups received current (which varied by group), while the controls, with identical electrodes, received no current. In vitamin $AD_3E$ administration group, experimental group was injected 2,500 IU of vitamin A, 1,250 IU of vitamine $D_3$, 1mg of vitamine E intramuscularly. And in control group 0.1ml of saline was injected intramuscularly. After time periods (7-day, 14-day, 21-day for stimulation all rats were tested with combination of biochemical, roentgenologic and histomorphological methods. The results obtained were as follows ; In electrical stimulation groups, serum calcium and inorganic phosphorus level of experimental and control groups showed non specific change within normal physiological ranges. In vitamin $AD_3E$ administration group, serum calcium level of experimental and control groups showed non specific changes within normal physiological ranges, while experimental group showed slightly higher serum inorganic phosphorus level. According to roentgenologic and histomorphological examination, 2V 25Hz electrical stimulation group and vitamine $AD_3E$ administration group showed statistically significant improvements in bone density and ossification reaction until day 14. The terapeutic effect of stimulation on fracture healing was similiar to that of vitamin $AD_3E$ administration. In this study stimulation of 2V 25Hz was the most effective level of electrical stimulation for the healing of fracture of rats.

  • PDF

예보된 스트레스에 의한 위궤양 발생에 미치는 뇌 해마 제거의 영향 (Effect of Hippocampectomy on Gastric Ulceration by Predicted Stress)

  • 김철;최현;김정진;김종규;김명석;박형진;조양혁
    • The Korean Journal of Physiology
    • /
    • 제14권1호
    • /
    • pp.1-5
    • /
    • 1980
  • This study was under taken to investigate the influences of predictable or unpredictable stress upon gastric ulceration, and the hippocampectomy upon the ulceration order the stressful conditions. Sixty male albino rats(Sprague-Dawley strain) were divided equally into 3 groups: One was the hippocampal group(N=20) which received hippocampal ablation by suction, another was the cortical control group(N =20) which received partial cortical ablation over the hippocampus, and a third was the normal control group(N=20). Each group was further divided into two subgroups: One was the predicted subgroup(N=10) in which animals could predict the imminent stressful stimuli by hearing a sound(1,000 Hz, 2 sec in duration) 3 sec before the onset of the stress, and the other was the unpredicted subgroup(N=10). After starvation for 24 hours, but water ad libitum, each rat received the electric stimulation(3 mA, 60 Hz, 2 sec in duration, and once per minute in average) for 6 hours via a pair of electrodes attached on the tale. The electric stimulation served as the stress causing the gastric ulcer. Five hours after completion of stimulation, the stomach filled with the physiological saline was removed under deep anesthesia and spread out on a small glass plate. The numbers of the ulcer in each stomach were counted and the shape was examined under the dissecting microscope. Results obtained were as follows: 1. The mean numbers of the ulcer of the predicted subgroups were significantly larger than those of the unpredicted subgroups in the normal control and the cortical control groups, but there was no difference between the values of the two subgroups in the hippocampal group. 2. The mean numbers of the ulcer of the predicted subgroups in the normal control and the cortical control groups were larger(but not significant) than that in the hippocampal group. It is inferred from the above results that the prediction of the stress strengthens the effect of the stress on the gastric ulceration, and the hippocampus facilitates the effect of the prediction of the stress.

  • PDF

결장염 유발 Rat의 결장운동성에 침술이 미치는 영향 (Effects of Traditional Acupuncture on Colonic Motility in the Rat with Colitis)

  • Kim, Hee-Young;Shim, In-Sop;Lee, Hye-Jung;Jeong, Seong-Mok;Kim, Sun-Young;Nam, Tchi-Chou
    • 한국임상수의학회지
    • /
    • 제20권1호
    • /
    • pp.22-25
    • /
    • 2003
  • 본 연구는 정상 및 결장염을 유발한 rat에서 침술이 결장운동성에 미치는 영향을 알아보고, 이에 내인성 opioid가 관여하는지의 여부를 알아보기 위하여 수행하였다. 22마리의 Sprague-Dawley rat을 정상군 (n=8), 결장염군 (n=6) 및 maloxone군(n=8)의 세군으로 나누어 실험을 실시하였다. Rat의 근위 결장의 장막하에 스테인레스 전극을 장착하고, 전극장착 7일 후에 trinitrobenzene sulphonic acid(TNBS)과 ethanol을 이용하여 결장염을 유발하였다. 결장의 근전도는 전극장착 11일 후에 trinitrobenzene sulphonic acid(TNBS)과 ethanol을 이용하여 결장염을 유발하였다. 결장의 근전도는 전극장착 11일 후에 polygraph를 이용하여 측정하였다. 정상군에서는 정상 결장의 기초 근전도를 60분간 기록한 후에 GV-1에 20분간 전통 침술을 실시하고, 다시 60분간 근전도를 가록하였으며, 결장염군에서는 TNBS/ethanol이 미리 투여된 rat에 정상군에서와 같은 방법으로 근전도 기록 및 침술을 실시하였다. Naloxone 군에서는 결장염군과 같은 방법으로 TNBS/ethanol이 미리 투여된 rat에 침술을 실시하기전 naloxone(3 mg/kg, SC)을 투여하고 다른 군에서와 마찬가지로 근전도와 침술을 실시하였다. 정상군에서는 침술이 결장의 운동성에 영향을 미치지 않았다. 그러나 TNBS/ethanol을 투여하여 결장염이 유발된 결장염군에서는 침술에 의해서 결장의 운동성이 유의적으로 저하되었다(p<0.01). Naloxone군에서는 침술에 의한 결장운동성의 저하는 관찰할 수 없었다. 이상의 결과로 보아 rat에서 GV-1 혈위의 침술에 의해 유발된 내인성 opioid는 염증상태의 결장 운동성을 감소시킨 것으로 사료된다.