• Title/Summary/Keyword: divided electrodes

Search Result 66, Processing Time 0.022 seconds

Omni-directional piezoelectric actuator using mixed mode (혼합 모드를 이용한 전방향성 초음파 액추에이터)

  • Jung, Woo-Suk;Kang, Jhong-Yun;Song, Hyun-Chul;Yoon, Seok-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.299-299
    • /
    • 2007
  • This paper presents an omni-directional piezoelectric actuator which utilizes only one actuator. The actuator has a simple structure of cone type consists of two piezoelectric ceramics of ring type and electrodes divided four segments and a stainless steel body. To find the optimal operating condition of the actuator, the frequency characteristics of the actuator are analyzed by ATILA, FEM and measured by Impedance Analyzer. We have also developed a stage using the omni-directional actuator and an actuator driver circuit to create four sinusoidal waves with a variable frequency and phase difference.

  • PDF

A Study on Rheology Characteristics of Ag Paste for Screen Printing Method for Silicon Solar Cells Electrodes Capable of Forming High Aspect Ratio (고온 소결형 실리콘 태양 전지의 High Aspect Ratio 전극 형성이 가능한 Ag 페이스트의 레오로지 특성 연구)

  • Oh, Tae-Hun;Kim, Sung-Bin;Nam, Su-Yong
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.28 no.1
    • /
    • pp.15-24
    • /
    • 2010
  • Photovoltaic solar cells are all in the incident because they are not converted into electrical energy, high-efficiency solar cells in order to reduce the loss of elements must be. Significant factor in the loss of solar cells, optical loss and electrical loss can be divided into. Optical losses occur when the sun will be joined on the surface of the reflection, the shadow loss due to electrodes, and the losses are in the solar wavelengths. Commercialization is currently the most common solar cells on the front of the light incident on the electrode is formed. Therefore, the shadow caused by the electrode to cover the dead area of the sun, due to factors that hinder the absorption of sunlight which is shadowing them and conversion efficiency of solar cells is the inhibition factor. These barriers to eliminate the electrode linewidth reduces the shadowing to reduce, but simply of the electrode line width is reduced electrode area by reducing the series resistance elevates this because to improve the electrode Aspect ratio(height/width) to increase Ag development of paste is required. In this study, aspect ratio of screen-printing method to increase the electrode Ag paste composition of the binder for the characterization of rheology in the shadow of the electrode by reducing the optical loss of the photoelectric conversion efficiency of solar cells to boost the performance measures was. Properties and printability of the paste, the binder resin sintered characteristics that affect the thermal properties are excellent with a good screen printability acrylic resin, ethyl cellulose, using a resin were evaluated. Prepared paste rheology properties, was formed to evaluate the electrode conductivity and aspect ratio.

Nerve Conduction Velocity through the Ventral Root Afferent Fibers in the Cat (고양이 척수전근 감각신경섬유의 흥분전도속도)

  • Kim, Jun;Hwang, Sang-Ik;Ho, Won-Kyung
    • The Korean Journal of Physiology
    • /
    • v.21 no.1
    • /
    • pp.59-66
    • /
    • 1987
  • This study was aimed to investigate whether the conduction velocity of nerve impulses through the ventral afferent fibers is constant along their entire courses in dorsal as well as in ventral roots. Cats were anesthetized with ${\alpha}-chloralose$ (60 mg/kg, i.p.) and artificially ventilated. Laminectomies were done on L4-S1 spinal vertebrae to expose the lumbosacral spiral cord. Both ventral and dorsal roots of L7 or S1 spinal segments were isolated and cut near the spinal cord. Ventral roots were placed on 6-lead stimulating electrodes and stimulated with supra C-threshold intensity. Divided dorsal root fascicles were placed on bipolar recording electrodes and single fiber units activated by the stimulation of the ventral roots were identified. Followings are the results obtained: 1) A total of 27 VRA units were identified. 10 units of them conducted impulses slower than 2 m/sec. Conduction velocities of the remaining units were in the range of 3.11-20.91 m/sec. 2) In 12 Units conduction velocities Of the VRA units through dorsal$(CV_{DR})$ and venral root$(CV_{DR})$ were determined respectively. There was a tendency to conduct impulses faster through dorsal roots$(CV_{DR}=8.19{\pm}3.26\;m/sec)$ than ventral roots$(CV_{DR}=3.46{\pm}1.02\;m/sec)$. From the above results we confirmed that there exist nerve fibers in continuity between the spinal ventral and dorsal roots but we could not ascertain whether there is a change in conduction velocity through the entire course of ventral afferent unit.

  • PDF

A STUDY ON THE EFFECT OF ORTHODONTIC FORCES AND EXOGENOUS ELECTRIC CURRENTS ON $PGE_2$ CONTNET OF ALVEOLAR BONE IN CATS (교정력 및 외인성 전류가 고양이 치조골의 prostaglandin $E_2$에 미치는 영향에 관한 연구)

  • Kim, Jong-Tae;Kim, Joong-Soo;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.14 no.2
    • /
    • pp.203-215
    • /
    • 1984
  • This experiment was performed to explore the effect of electric currents and orthodontic forces on bone $PGE_2$ content and orthodontic tooth movement on cats. Stainless steel electrodes were connected a power pack consisting of five miniature batteries, a transistor, and a resistor. The current $(10{\pm}2{\mu}A)$ was provided by a constant source encased in a palatal acrylic plate. In first experiment, the cathode was placed mesial to the right maxillary canine tooth and the anode was positioned distal to the tooth, Sham electrodes were placed new the left cuspid, to serve as control. Nine cats were divided into three groups evenly. Groups of three animals were treated with electric currents only-for 1, 3 and 7 days, respectively. In second experiment, electric currents and the orthodontic forces of about 80 gm were applied to the right maxillary canine, and the orthodontic forces only were applied to the left maxillary canine. 3 groups of three cats each were treated in this experiment-for 1, 3 and 7 days, respectively. Alveolar bone samples were obtained from sites of tension and compression as well as from contralateral sites. Bone samples were extracted by homogenization in $40\%$ ethanal. The supernatant partitioned twice with 2 volumes of petroleum ether to remove neutral lipids and the aqueous supernatant partitioned in ethyl acetate. After drying the solvent, $PGE_2$ was measured by radioimmunoassay technique. The obtained results were as follows. 1. Teeth treated with combined force and electricity moved faster than those treated with force alone. 2. Alveolar bone $PGE_2$ content of electric stimulation was increased at both electrodes. 3. Alveolar bone $PGE_2$ content of mechanical stimulation at compression sites was gradually increased at all time period. At tension site, $PGE_2$ content increased after 1 day of mechanical stimulation remained elevated at all time period. 4. Alveolar bone $PGE_2$ content of compression sites was increased more than that of tension sites from mechanical stimulation as well as electrical stimulation.

  • PDF

Electromyographic studies on the masseter and temporal muscles during exchange of the deciduous teeth (유치 교환기의 교근 및 측두근의 근전도 연구)

  • Lee, Jong-Heun
    • The Korean Journal of Physiology
    • /
    • v.3 no.1
    • /
    • pp.33-44
    • /
    • 1969
  • Electoromyographic studies were performed on the action of the muscles of the temporomandibular joints following exfoliation of the deciduous teeth. The subjects examined, being 50 children. between the age of 6 and 13 years, divided into 5 groups. They were; 1) Deciduous dentition were complete in the first group. 2) Deciduous incisors were missing in either upper or lower jaw in the second group. 3) Deciduous canine and molars were missing in the left side of either upper or lower jaw in the third group. 4) Deciduous canine and molars were missing in the right side of either upper or lower jaw in the fourth group. 5) Permanent dentition completed in the fifth group(except third molars). Electromyogram was recorded with 4 channel polygraph (Grass model VII modified for 7P3). Electrodes which were the cup-typed gold discs, 9 millimeters in the diameter, were located on the anterior, middle and posterior lobes of the temporal muscles, and also on the superficial and deep layers of the masseter muscles. Paired electrodes were held by electrode cream so that they were pressed on the skin surface at right angle, adhesive tape being used to anchor them. The distance of the pair electrodes was about 5 millimeters. The results obtained were as follow: 1) In rest position of mandible; All groups showed slight, electrical activities in the muscles involved, but in the middle lobe of temporal muscle they were slightly higher. 2) In molar occlusion of mandible; High activity-anterior lobe of temporal muscle and superficial layer of masseter muscle. Moderate activity-deep layer of masseter muscle. Low activity-middle and posterior lobes of masseter muscle. There were no differences among the first, the second and the fifth groups. In the third group the muscle activity was weaker than that of the right, and in the fourth group opposite characteristics was revealed. 3) In incisal bite of mandreble; Hight activity-superficial layer of masseter muscle. Modertae activity-deep layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. The first, the third, the fourth and the fifth groups showed no differences but the second group showed less activity than those of others. 4) In protrusion of mandible; High activity-deep layer of masseter muscle Moderate activity-superficial layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. In the first, the fourth and the fifth groups, there were no differences in the activities, but the second group showed less activity than the others. 5) In retrusion of mandible; High activity-deep layer of masseter muscle. Moderate activity-superficial layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. In the first, the third, the fourth and the fifth groups, there were no differences but the second group showed less activity than the others. 6) In lateral excursion of the mandible (either direction); High activity-posterior lobe of temporal muscle. Moderate activity-anterior and middle lobes of temporal muscle. Low activity-superficial and deep layers of masseter muscle. The muscle action potentials were weaker than those of the right side in the third group and vice ver'sa in the fourth group. 7) In chewing movement; Temporal muscle activities were higher than those of masseter, especially in the middle lobe of temporal muscle the activity was highest. Right side muscle activities were higher than those of the left in the third group and, on the contrary, the left side was dominant over the right in the fourth group.

  • PDF

Contactless Suspension and Propulsion of Glass Panels by Electrostatic Forces

  • Jeon, Jong-Up;Park, Kyu-Yeol;Higuchi, Toshiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.950-955
    • /
    • 2004
  • In the manufacture of liquid crystal display devices, there is a strong demand for contactless glass plate handling devices that can manipulate a glass plate without contaminating or damaging it. To fulfill this requirement, an electrostatic transportation device for glass plates is proposed. This device can directly drive a glass plate and simultaneously provide contactless suspension by electrostatic forces. To accomplish these two functions, a feedback control strategy and the operational principle of an electrostatic induction motor are utilized. The stator possesses electrodes which exert electrostatic forces on the glass plate and are divided into a part responsible for suspension and one for transportation. To accomplish dynamic stability and a relatively fast suspension initiation time, the structure of the electrode for suspension possesses many boundaries over which potential differences are formed. In this paper, an electrode pattern suitable for the suspension of glass plates is described, followed by the structure of the transportation device and its operational principle. Experimental results show that the glass plate has been transported with a speed of approximately 25.6 mm/s while being suspended stably at a gap length of 0.3 mm.

  • PDF

The Kinetic and EMG Analysis about Supporting Leg of Uke in Judo (유도 허벅다리걸기 기술 발휘 시 지지발에 대한 근전도 및 운동역학적 분석)

  • Park, Jong-Yul;Kim, Tae-Wan;Choi, In-Ae
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.197-205
    • /
    • 2007
  • The purpose of this study is to analyze the muscle activations and Ground Reaction Force(GRF) in university judo players, and provide the guide of training in Judo. Using surface electrode electromyography(EMG), we evaluated muscle activity in 5 university judo players during the Judo Uke Movements. Surface electrodes were used to record the level of muscle activity in the Tibialis Anterior, Rectus Femoris, Elector Spinae, Gluteus Maximus, Gastrocnemius muscles during the Uke. These signals were compared with %RVC(Reference voluntary contraction) which was normalized by IEMG(Integrated EMG). The Uke was divided into four phases : Kuzushi-1, Kuzushi-2, Tsukuri, Kake. The results can be summarized as follows: 1. The effective Uke Movements needs to short time in the Kake Phase 2. The Analysis of Electromyography of Uke Movements in Supporting Leg; TA(Tibialis anterior) had Higher %RVC in the Kuzushi Phase, RF(Rectus Femoris) had Higher %RVC in the Tsukuri Phase, GM(Gluteus Maximus) had Higher %RVC in the Kake Phase 3. The ground reaction force for Z(vertical) direction was showed increase tendency in Kuzushi phase, Tsukuri phase and decrease tendency in Kake phase.

The Study on Explosion Phenomena of a Metal Wire by Rapid Heating in Water (초고속가열에 의한 금속세선의 폭발현상에 관한 연구)

  • Jang, In-Seon;Kim, Jong-Su
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.1
    • /
    • pp.27-37
    • /
    • 1997
  • The aim of the present study is to investigate experimentally the mechanism of an exploding wire in water and also to observe the bubble motion induced by an exploding wire. The experiment of an exploding wire is carried out in a water tank. As a metallic wire, a tungsten wire of 0.2mm in diameter and 10mm in length is employed. The electric energy of 50-300J is fed to the wire from a capacitor of 100$\mu$F charged up to 1-2.5kV. The explosion is recorded by a CCD camera with the resolution of 1$\mu$sec. The explosion process of metallic wire is divided into three phases. Phase 1 : As the voltage is applied to the wire, the temperature increases due to Joule heating and the wire emits light. Phase 2 : Then the wire melts and the cylindrical plasma is formed between the electrodes. Up to this stage, strong light emission is observed. Phase 3 : The light emission goes out and a vapor bubble begins to grow spherically. The radius of a bubble oscillates in time, but the amplitude of oscillation diminishes in several cycles.

  • PDF

Electrostatic Suspension and Transportation Device of Glass Panels (정전기력을 이용한 유리 판넬의 비접촉 지지 및 반송)

  • Jeon Jong-Up
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.3 s.180
    • /
    • pp.76-85
    • /
    • 2006
  • In the manufacture of liquid crystal display devices, there is a strong demand for contactless glass panel handling devices that can manipulate a glass panel without contaminating or damaging it. To fulfill this requirement, an electrostatic transportation device for glass panels is proposed. This device can directly drive a glass panel and simultaneously provide contactless suspension by electrostatic forces. To accomplish these two functions, a feedback control strategy and the operational principle of an electrostatic induction motor are utilized. The stator possesses electrodes which exert electrostatic farces on the glass panel and are divided into a part responsible for suspension and one for transportation. To accomplish dynamic stability and a relatively fast suspension initiation time, the structure of the electrode for suspension possesses many boundaries over which potential differences are formed. In this paper, an electrode pattern suitable for the suspension of glass panels is described, followed by the structure of the transportation device and its operational principle. Experimental results show that the glass panel has been transported with a speed of approximately 25.6 mm/s while being suspended stably at a gap length of 0.3 mm.

The Analysis of Electromyography and Kinematic of Kumdo Player's Head Hitting (검도 머리치기 동작의 근전도 및 운동학적 분석)

  • Park, Jong-Rul
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.1
    • /
    • pp.63-74
    • /
    • 2005
  • J. R. PARK. The Analysis of Electrimyography and Kinematic of Kumdo Player's Head Hitting. Korean Journal of Sport Biomechanics, Vol. 15, No. 1, pp. 63-74, 2005. The purpose of this study were to describe and compare the selected electromyographical muscle activities of arm and kinematic data of kumdo player's head hitting. Using surface electrode electromyography, we evaluated muscle activity in 6 male players during head hitting motion. Surface electrodes were used to record the level of muscle activity in the carpi radialis, deltoid, triceps, biceps muscles during the player's head hitting. These signals were compared with %RVC(Reference voluntary contraction) which was normalized by IEMG(Integrated EMG). The kumdo head hitting motion was divided into two phases: back swing, down swing. we observed patterns of arm muscle activity throughout two phases of the kumdo head hiting The results can be summarized as follows: right elbow angle had decreased and left deltoid muscle's activation had higher than right deltoid muscle's activation, right carpi radialis muscle's activation had higher than left carpi radialis muscle's activation in back swing phase, knee angle had decreased and left triceps muscle's activation had higher than right triceps muscle's activation, right deltoid muscle's activation had higher than left deltoid muscle's activation, right carpi radialis muscle's activation had higher than left carpi radialis muscle's activation in down swing phase