• Title/Summary/Keyword: district heating system

Search Result 235, Processing Time 0.022 seconds

A Study on the Transition & Expectation through Survey for Existing Building and Engineer's Opinion (기존 사무소 건물 및 설비전문가 조사를 통한 설비시스템의 변화와 전망에 대한 연구)

  • Lee, Gwan-Ho;Kim, Nam-Gyu;Park, Jin-Chul;Rhee, Eon-Ku
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.63-69
    • /
    • 2005
  • This study is the survey of a transition procedure of building services systems(heat source, HVAC, water supply) through the survey of existing office buildings, building design documents. The preference & major consideration of system selection is the engineer's opinions. The results of this survey can be used in selection of building services system design. In this survey, "Hot & cold water generator system" and "single duct CAV+FCU system", "Elevated water tank system" are selected. The most important consideration in system selection is the energy saving in heat source system, and comfort in HVAC system, and water pressure in water supply system. They prefer "steam boiler+absorption chiller system" for heat source system, "steam boiler+ice thermal storage system", "hot & cold water generator system", "district heating+absorption chiller system" : "single duct CAV+FCU system" and "single duct VAV+convector system" for HVAC system: and "booster pump system" for water supply system.

Development of a Failure Probability Model based on Operation Data of Thermal Piping Network in District Heating System (지역난방 열배관망 운영데이터 기반의 파손확률 모델 개발)

  • Kim, Hyoung Seok;Kim, Gye Beom;Kim, Lae Hyun
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.322-331
    • /
    • 2017
  • District heating was first introduced in Korea in 1985. As the service life of the underground thermal piping network has increased for more than 30 years, the maintenance of the underground thermal pipe has become an important issue. A variety of complex technologies are required for periodic inspection and operation management for the maintenance of the aged thermal piping network. Especially, it is required to develop a model that can be used for decision making in order to derive optimal maintenance and replacement point from the economic viewpoint in the field. In this study, the analysis was carried out based on the repair history and accident data at the operation of the thermal pipe network of five districts in the Korea District Heating Corporation. A failure probability model was developed by introducing statistical techniques of qualitative analysis and binomial logistic regression analysis. As a result of qualitative analysis of maintenance history and accident data, the most important cause of pipeline damage was construction erosion, corrosion of pipe and bad material accounted for about 82%. In the statistical model analysis, by setting the separation point of the classification to 0.25, the accuracy of the thermal pipe breakage and non-breakage classification improved to 73.5%. In order to establish the failure probability model, the fitness of the model was verified through the Hosmer and Lemeshow test, the independent test of the independent variables, and the Chi-Square test of the model. According to the results of analysis of the risk of thermal pipe network damage, the highest probability of failure was analyzed as the thermal pipeline constructed by the F construction company in the reducer pipe of less than 250mm, which is more than 10 years on the Seoul area motorway in winter. The results of this study can be used to prioritize maintenance, preventive inspection, and replacement of thermal piping systems. In addition, it will be possible to reduce the frequency of thermal pipeline damage and to use it more aggressively to manage thermal piping network by establishing and coping with accident prevention plan in advance such as inspection and maintenance.

Characteristic Analysis of Hybrid Desiccant Cooling System for District Heating in Residential Environment (지역난방에 연계된 하이브리드 제습냉방시스템의 주거환경에서의 성능 분석)

  • Ahn, Joon;Kim, Jaeyool;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.7
    • /
    • pp.571-579
    • /
    • 2014
  • A series of field tests on hybrid desiccant cooling systems were conducted in July-August, 2013. The temperature and humidity of the supply and return air, power, and heat consumption were monitored and transferred in real time through the Internet. The performance parameters of the cooling system, namely, cooling capacity and COP (coefficient of performance), were evaluated from the measured data and their variations under outdoor conditions was analyzed. It was found that with increase in the outdoor temperature, the total energy decreases and cooling capacity increases whereas the latter decreases with increase in the outdoor humidity. The COP was also found to increase with the increase in outdoor temperature.

Study on OTEC System using Condenser Effluent from Nuclear Power Plant (원자력발전소 온배수를 이용한 해양온도차발전에 대한 연구)

  • Seo, Hyang-Min;Park, Sung-Seek;Shin, Sang-Ho;Kim, Chong-Bo;Kim, Nam-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1267-1272
    • /
    • 2008
  • OTEC power plants are studied as a viable option for the supply of clean energy. In this paper, the thermodynamic performance of OTEC system was calculated. The results show that the working fluids such as R32 and R125 would be alternatives based upon cutting down the system size, environmental preservation, and conditions without having a severe penalty in efficiency. the initial cost significantly. The regeneration system increase in energy efficiency, and the system can generate electricity when the difference in warm and cold seawater inlet temperatures are greater than $15^{\circ}C$. Also, the system efficiency of OTEC power plant using the condenser effluent from nuclear power plant instead of the surface water increased about 2%.

  • PDF

Virtual Analysis of District Heating System Using ENetPLAN (EnetPLAN을 이용한 지역난방시스템 가상 운전 분석)

  • Ahn, Jeongjin;Lee, Minkyung;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.18-25
    • /
    • 2019
  • In this study, in order to solve the problem of the program of calculating code input by experienced users in the power generation, the wide area energy network research group developed the local heating operation analysis program EntPLAN, which can be easily used by anyone, including scalability, with domestic technology. Therefore, the Commission intended to compare the heat sources, heat demand, and the results of operation of the combined heat plant (CHP) on the energy network through simulation with the EnetPLAN and the program A on the market. The results showed that the heat and power output on the energy network of the EnetPLAN and A programs were mostly similar in pattern in the simulation results of the heat supply and the operation method of the accumulator. This enabled the application of the simulation for the various operation modes of the cogeneration facilities existing on the energy network. It is expected that EntPLAN, which was developed with domestic technology, will be easily applied in the field in the future and will present efficient operation simulation results.

A study on the temperature of District Heating System related to Energy Consumption of Combined Heat & Power (지역난방 공급온도의 변화가 열병합발전 에너지소비량에 미치는 영향에 관한 연구)

  • 정찬교
    • Journal of Energy Engineering
    • /
    • v.3 no.2
    • /
    • pp.179-186
    • /
    • 1994
  • 본 연구는 지역난방용 열병합발전시스템의 열에너지 이용을 최대화하므로 1차에너지의 소비량을 감소시키는데 그 목적이 있으며, 이를 위한 한가지 방안으로 열추종 운전범위내에서 온도에 따른 지역난방 운전방법을 분석검토하였다. 운전가능한 지역난방 공급 및 회수온도에 따른 지역난방 운전방법을 분석검토하기 위하여 수치해석 프로그램 CHPSIM을 사용하여 열병합발전시스템의 열적상태와 열추가소비량을 계산하였다. 지역난방의 온도수준을 120/$65^{\circ}C$에서 95/4$0^{\circ}C$로 저하시킴으로서 년간 열추가 소비량을 24.7% 감소시킬 수 있으며, 90/4$0^{\circ}C$로 저하시키면 29.6%의 절약이 가능하다.

  • PDF

An Analysis on Policy Trends of the Use and Development of Nuclear Power in Nuclear Advanced Countries (주요국의 원자력이용개발 정책동향 분석)

  • 차종희;조흥곤;양맹호
    • Journal of Korea Technology Innovation Society
    • /
    • v.6 no.4
    • /
    • pp.462-479
    • /
    • 2003
  • The policy trends of use and the development of nuclear power in the United States, France, United Kingdom. Germany, Russia, China, Japan and Korea are briefly investigated. Nuclear power technology has been developed as the national policy in the nuclear-advanced countries. 50 years has passed since the declaration of "Atoms for Peace" by USA President Eisenhour in December 1953. Recently, it appears to revitalize the nuclear power program in world major countries in order to recover the shortage of electric power and to curb the excess emission of carbon dioxide as well as to secure competitiveness in electricity markets. Advanced countries are making new initiatives for the development of the fourth generation nuclear power system. Furthermore, wide-ranged use and development of nuclear power technologies are expected in district heating in commercial sectors, power in the space exploration, and propulsion power of large tankers and spaceships. High temperature gas cooled nuclear power reactor will be applied for mass production of hydrogen energy in the future.

  • PDF

A study on the principal cost of district heating transportation system related to low supply temperature (공급온도 저하에 따른 지역난방 배관망 기초비용에 관한 연구)

  • 김석순;정찬교;최기련
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.11a
    • /
    • pp.82-87
    • /
    • 1995
  • 국내 지역난방의 역사는 서구의 역사와 비교하여 짧기 때문에 아직 기술 도입의 의존도가 높고 설계에 있어서도 서구의 설계기준을 그대로 도입하여 지역난방 시스템을 운전하고 있다. 따라서 우리나라 실정에 맞는 시스템설계가 필요하다고 하겠다. 특히 열원시설과 수용가 시설사이에서 열을 운송하는 열운송시설, 즉 배관망(이후 배관망으로 칭한다.)에서의 공급 및 회수온도가 유럽의 대류난방방식에 따라 설계되어 높게 설정되어 있다. 공급 및 회수온도가 높다는 것은 열운송시 열손실이 많다는 것을 의미한다. 이에 이 연구에서는 일정 배관망 모델을 선정하여 공급 및 회수온도를 낮추어 운전할 때 발생되는 비용변화를 기초로 공급 및 회수온도 저하운전 가능성을 제시하고자 하였다. 그 결과 배관망에서 공급 및 회수온도를 동일 구배로 낮추는 것이 년간 총 비용을 감소시키므로, 운전온도의 저하가 가능함을 알 수 있었다.

  • PDF

Prediction of Possibility of Indoor Pipe Freezing in Heat Only Boiler Room through Thermal Analysis (열분석을 통한 열전용 보일러동 실내배관의 동파 가능성 예측)

  • Lim, Byoung-Ik;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.3
    • /
    • pp.19-28
    • /
    • 2012
  • In a heat only boiler system of a steam power plant, outdoor air required for combustion is made to pass through indoor space for increasing the boiler efficiency. Due to heat generated by various equipments, temperature of the air that enters the boiler will increase resulting in combustion efficiency. If the outdoor air temperature is low, however, this will cause freezing and bursting of pipes which are filled with water. It is especially fatal to small diameter pipes and pipes connected to measuring instruments. The purpose of this study is find operation and outdoor conditions where this phenomena can happen and also establish preventive measures to avoid this problem.

Biomass to Energy: Renewable Fuel Production Processes for Clean Combustion (바이오매스 에너지화: 청정 연소를 위한 신재생 연료 생산 공정)

  • Jeong, Jaeyong;Kim, Youngdoo;Yang, Won;Lee, Uendo;Jeong, Suhwa;Bang, Byungryul;Moon, Jihong;Hwang, Jeongho;Chang, Wonsuk
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.285-285
    • /
    • 2015
  • Utilization of biomass as a substitute fuel for conventional energy systems have been grown larger everyday in the world. In particular, co-firing of biomass in a large coal power plant are common in Korea after the introduction of RPS since 2012, and the application of biomass-derived fuel is now spreading to district heating and power, industrial energy supply, and transportation sectors. For biomass to energy, appropriate conversion process is needed to satisfy the fuel requirements of a specific energy system. In this study, various kinds of thermochemical conversion technologies will be presented for renewable fuel productions from biomass.

  • PDF