• Title/Summary/Keyword: distribution parameter

Search Result 2,520, Processing Time 0.029 seconds

Measurements of Void Concentration Parameters in the Drift-Flux Model (상대유량 모델내의 기포분포계수 측정에 관한 연구)

  • Yun, B.J.;Park, G.C.;Chung, C.H.
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.91-101
    • /
    • 1993
  • To predict accurately the thermal hydraulic behavior of light water reactors during normal or abnormal operation, the accurate estimation of the void distribution is required. Up to date, many techniques for predicting void fraction of two-phase flow systems have been suggested. Among these techniques, the drift-flux model is widely used because of its exact calculation ability and simplicity. However, to get more accurate prediction of void fraction using drift-flux model, slip and flow regime effects must be considered more properly In the drift-flux method, these two effects are accounted for by two drift-flux parameters ; $C_{o}$ and (equation omitted). At earlier stage, $C_{o}$ is measured in a circular tube. In this study, $C_{o}$ is experimentally determined by measuring local void fraction and vapor velocity distribution in a rectangular subchannel having 4 heating rods which simulates nuclear subchannels. The measurements are peformed with two-electrical conductivity probes which are known to be adequate for measuring local parameters. The experiments are performed at low flow rate and the system pressure less than 3 atmo spheric pressure. In this experiment, (equation omitted), is not measured, but quoted from well-known empirical correlation to formulate $C_{o}$. Finally, $C_{o}$ is expressed as a function of channel averaged void fraction. fraction.

  • PDF

Comparison of Chukwooki and Modern data Using Annual Maximum Rainfall Event Series (연최대 호우사상 계열을 이용한 측우기자료 및 현대자료의 비교)

  • Park, Minkyu;Yoo, Chulsang;Kim, Hyeon Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2B
    • /
    • pp.137-147
    • /
    • 2010
  • In this study, Chukwooki and modern data were compared using annual maximum rainfall event series. Annual maximum series for specified rainfall duration in modern frequency analysis can not be constructed from Chukwooki data, so the concept of independent rainfall event is introduced to compare Chukwooki and modern data. Annual maximum rainfall event is determined by applying the bivariate exponential distribution and the parameters estimated annually are selected. The results using the annual parameter show that the hydrological meaning of the parameters is related to the variation of annual total rainfall amounts. For the whole independent rainfall events, the total rainfall and the rainfall intensity of Chukwooki data are greater than those of modern data, and rainfall duration of the two periods is similar. However modern annual maximum rainfall events show different characteristics that rainfall duration is much longer, rainfall intensity is similar and the total rainfall is greater than those of Chukwooki period. The increasing trend of rainfall duration and total rainfall of the modern annual rainfall events may be regarded as the one of components of the long-term cycle.

Elasto-plastic Earthquake Response Analysis of Beam-Shear Wall Structural System (보-전단벽식 구조 시스템의 탄소성 지진응답 해석)

  • 정명채;이정원
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.57-67
    • /
    • 1997
  • The objective of present paper is to investigate elasto-plastic behaviour and estimate the resistance capacity of a beam-shear wall structural system against earthquake ground accleration exciations. Pushover analysis is adopted to estimate inttiate and post stiffnesses and yielding point for inelastic response analysis in LPM (Lumped Parameter Mass) model, and modified Clough model is used as the hysteresis rule of each story. Three earthquake waves are used in the analysis but their peak ground accelerations are changed to be 0.12g, 0.24g. It is assumed that the earthquakes act in the longigtudianl direction of a 25 Story apartment building which consists of two some unit plan. The distribution of story ratio and ductility ratio are estimated and discussed within Korean, Japanese code and UBC.

  • PDF

Study on the Optimization of Pulse GTAW Process for Diaphragm with Thin Thickness (극박 다이아프램의 펄스 GTAW 공정 최적화에 관한 연구)

  • Park, Hyoung-Jin;Hwang, In-Sung;Kang, Mun-Jin;Rhee, Se-Hun
    • Journal of Welding and Joining
    • /
    • v.26 no.1
    • /
    • pp.63-68
    • /
    • 2008
  • This paper has aimed to prevent excessive heat input by controlling arc distribution and heat input capacity with pulse GTAW in order to improve weld quality in 0.08mm pressure gauge diaphragm and flange welding parts. A design of experiment was designed using Box-Behnken method to optimize a welding process. The pulse GTAW parameters such as pulse current, base current, pulse duty, frequency and welding speed were set to input variables while hydraulic pressure that represents welding characteristics in diaphragm and flange joint were set to output variables. Based on the test result, a second regression equation was obtained between input and output variables and turned out significant. Besides, an influence of parameters has been confirmed through response surface analysis using the second-order regression equation and optimum welding condition was obtained through a grid-search method. The optimum welding condition was set to pulse current 84.4(A), base current 29.6(A), pulse duty 58.8(%), frequency 10(%), and welding speed 596(mm/min). Then, decent bead shape was acquired with no excessive heat input under the $2.3kgf/cm^2$ of hydrostatic pressure.

Optimal Thresholds from Mixture Distributions (혼합분포에서 최적분류점)

  • Hong, Chong-Sun;Joo, Jae-Seon;Choi, Jin-Soo
    • The Korean Journal of Applied Statistics
    • /
    • v.23 no.1
    • /
    • pp.13-28
    • /
    • 2010
  • Assuming a mixture distribution for credit evaluation studies, we discuss estimating threshold methods to minimize errors that default borrowers are predicted as non defaults or non defaults are regarded as defaults. A method by using statistical hypotheses tests, the most powerful test and generalized likelihood ratio test, for the probability density functions which are defined with the score random variable and the parameter space consisted of only two elements such as the default and non default states is proposed to estimate a threshold. And anther optimal thresholds to maximize classification accuracy measures of the accuracy and the true rate for ROC and CAP curves are estimated as equations related with these probability density functions. Three kinds of optimal thresholds in terms of the hypotheses testing, the accuracy and the true rate are obtained from normal random samples with various means and variances. The sums of the type I and type II errors corresponding to each optimal threshold are obtained and compared. Finally we discuss about their efficiency and derive conclusions.

Parameter Study of Impact Characteristics for a Vacuum Interrupter Considering Dynamic Material Properties (동적 물성치를 고려한 진공 인터럽터 충격특성의 영향인자 분석)

  • Lim, Ji-Ho;Song, Jeong-Han;Huh, Hoon;Park, Woo-Jin;Oh, Il-Seong;Ahn, Gil-Young;Choe, Jong-Woong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.5
    • /
    • pp.924-931
    • /
    • 2002
  • Vacuum interrupters in order to be used in various switch-gear components such as circuit breakers, distribution switches, contactors, etc. spread the arc uniformly over the surface of the contacts. The electrodes of vacuum interrupters are made of sinter-forged Cu-Cr materials for good electrical and mechanical characteristics. Since the closing velocity is 1-2m/s and impact deformation of the electrode depends on the strain rate at that velocity, the dynamic behavior of the sinter-forged Cu-Cr is a key to investigate the impact characteristics of the electrodes. The dynamic response of the material at the high strain rate is obtained from the split Hopkinson pressure bar test using disc-type specimens. Experimental results from both quasi-static and dynamic compressive tests are Interpolated to construct the Johnson-Cook model as the constitutive relation that should be applied to simulation of the dynamic behavior of the electrodes. The impact characteristics of a vacuum interrupter are investigated with computer simulations by changing the value of five parameters such as the initial velocity of a movable electrode, the added mass of a movable electrode, the wipe spring constant, initial offset of a wipe spring and the virtual fixed spring constant.

Distribution of Weakness at the Lower Extremity of Hemiparesis Patients (편측부전마비환자의 하지에서의 위약증상의 분포)

  • Park, Gun-Ju;Hah, Jung-Sang;Kim, Wook-Nyeun
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.1
    • /
    • pp.101-110
    • /
    • 1997
  • The maximal voluntary strength of knee extension and flexion on both the right and left sides was measured in patients with hemiparesis of upper motor neuron type and in a group of normal subjects. Significant differences of maximal voluntary strength were found between male and female but the ratio of flexor to extensor strength did not vary significantly between the sides, between the sex in normal subjects. The maximal voluntary strength of uninvolved side were not reduced significantly but involved side reduced significantly in patients. The ratio of flexor to extensor strength in hemiparetic side was significantly less than the ratio for the normal subjects but not significant difference in uninvolved side of patients. According to the above results, the maximal voluntary strength of flexion was more reduced than that of the extension in lower extremity of hemiparesis patients. The strength ratio of flexion to extension was a useful parameter for guiding the rehabilitation of hemiparesis.

  • PDF

Distributed evacuation guide system based on positioning information of passengers in the subway station (승객 위치정보 기반 지하철 분산대피 안내 시스템)

  • Kim, Nammoon;Kim, Youngok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4528-4535
    • /
    • 2014
  • In this paper, a distributed evacuation system based on the positioning information of subway passengers is proposed. Recently, the subway station is becoming complicated by combining with shopping malls, and movie theaters. Compared to the increasing complexity of subway stations, evacuation systems are less complex. Subway passengers in each cell were estimated to use the access point in the subway cells and statistics information. The evacuation route is provided through a direction indicator and push alarm of a smart phone based on estimated the number of passengers and exit information of the subway station. Based on this schemes, a quick and safe evacuation system of subway passengers was proposed. The number of connection passengers was estimated using AP with OpenWrt embedded OS installed. The average error rate of the number of passenger was confirmed to be 15%, 17% and 23% at the confidence parameter of $1{\sigma}$, $2{\sigma}$, and $3{\sigma}$, respectively, through a simulation. The possibility of the system through a simple experiment was examined.

Use of Pyrosequencing for Characterizing Microbial Community at Phylum Level in Yeongsan River Watershed during Early Summer (Pyrosequencing을 이용한 하절기 영산강 유역의 Phylum 계층의 세균 군집 조사)

  • Chung, Jin;Park, Sang Jung;Unno, Tatsuya
    • Korean Journal of Microbiology
    • /
    • v.49 no.2
    • /
    • pp.150-155
    • /
    • 2013
  • We have conducted pyrosequencing for freshwater microbial community analyses. Fourteen sites along the Yeongsan river were selected for this study, and samples were collected monthly from May to July, 2012. Total 987,380 reads were obtained from 42 samples and used for taxonomic classification and OTU distribution analysis. Our results showed that high geographical and temporal variation in the phylum level bacterial composition, suggesting that microbial community is a very sensitive parameter affected by the surrounding environments including tributaries and land use nearby. In addition, we conducted an OTU-based Microbial Source Tracking to identify sources of fecal pollution in the same region. From this study Firmicutes was found to be the most influential taxa in this region. Here, we report that the use of pyrosequencing based microbial community analysis may give an additional information on freshwater quality monitoring, in addition to the currently used water quality parameters, such as BOD and pH.

Design Comparison of Strut Tie Model and ACI Traditional by Clear Span-to-Depth Ratio (지간-높이 비에 따른 스트럿-타이 모델과 ACI 고전적인 방법의 설계 비교)

  • Lymei, Uy;Son, Byung-Jik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2406-2413
    • /
    • 2014
  • Since clear span-to-depth ratio is used to define what is so called a deep beam, it is an important parameter ratio for study about deep beam. Deep beams can be designed by flexure design method, and shear provided by concrete ($v_c$) and by steel ($v_s$) for deep flexure members are provided in ACI 318-99 [1]. But in later version of ACI (from ACI 318-02) it is not provided and deep beams shall be designed either by taking into account nonlinear distribution of strain or by Appendix A of Strut-and-Tie Models (STM). The trend of deep beam design seems to be familiar with strut-and-tie model, but ACI traditional design is not forgotten. By comparing these two method, there should a point which definitely explain the different between the two methods. In this study, 68 samples result of steel, after reinforcement arrangement, are taken to be analyzed.