• Title/Summary/Keyword: distribution modeling

검색결과 2,590건 처리시간 0.03초

자동차 방향지시등 렌즈설계를 우한 CAD 시스템의 개발에 관한 연구 (A study on the development of CAD system for the design of lens of the turn signal lamp)

  • 이재원;이우용
    • 오토저널
    • /
    • 제15권3호
    • /
    • pp.89-95
    • /
    • 1993
  • This paper presents the development of CAD system for the design of lens of the Turn Signal Lamp that can model and simulate its optical performance. The system consists of three main modules: skin surface modeling module, inner lens modeling module and optical performance simulation module. Skin surface geometry can be modeled by the input of data file and inner lens can be modeled by the input of only four parameter using its geometric characteristics. Also light distribution pattern, the barometer of optical performance is generated by means of finite ray tracing method. The system display modeled geometry, ray tracing and generated light distribution pattern.

  • PDF

PSCAD를 이용한 상시 루프배전시스템의 보호계전기 모델 (A PSCAD Modeling of Protection Relay of On-Line Distribution System)

  • 김진수;박진현;조보현;문원식;조성민;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.406-407
    • /
    • 2011
  • The closed-loop distribution system is more flexible and more reliable than radial system. If any type fault occurs, the reliability of system can be better by providing electrical energy through another distribution line. However, it needs protection device coordination of different type. Typically, it is available by using directional overcurrent relay (67). This paper gives a solution about loop protection relay modeling which can be used by the simulation tools.

  • PDF

배광데이터를 이용한 평면프리즘 조명기구의 배광 모델링 (The Luminous Intensity Distribution Modeling of Planar Prism Using Photometric Data)

  • 김유신;최안섭;김훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.14-18
    • /
    • 2005
  • It is important to select light sources and luminaires in the process of lighting design. Therefore, development of light sources has been constantly grown for a high efficacy and long life. And, the design of luminaires has been developed for the reflection of light mechanism. But it has been not enough to study for the refraction of light mechanism Therefore, the propose of this study is to study for the refraction of light mechanism. In addition, this study is modeling for the luminous intensity distribution of planar prism to use the results of photometric data that is able to obtain various luminous intensity distribution.

  • PDF

군속도 변화를 이용한 배관 두께 측정 (Estimation of the Pipe Thickness using the Variation of the Group Velocity)

  • 한승희;황종명;이장명
    • 로봇학회논문지
    • /
    • 제5권1호
    • /
    • pp.32-40
    • /
    • 2010
  • This paper proposes the technique of estimating the pipe thickness using the measured group velocity. To measure the group velocity from the accelerometer data in the frequency domain, Wigner-Ville distribution is utilized, which interprets the waveform of the shock wave. Using this measured group velocity, this paper proposes the technique to estimate the thickness of pipes with the impact on the pipe. The group velocity is estimated by the modeling correlation between the group velocity and the thickness of the pipe based on the propagation velocities. The correlation model between thickness and group velocity has been proved through the real experiments. The measured group velocity in the frequency-domain is the maximum at the center frequency of the bending waves in the modeling of the group velocity. In addition to these, a smoothing technique for analyzing lamb wave Wigner-Ville distribution has been introduced to improve the reliability of the data acquisition.

Relative Power Density Distribution Calculations of the Kori Unit 1 Pressurized Water Reactor with Full-Scope Explicit Modeling of Monte Carlo Simulation

  • Kim, Jong-Oh;Kim, Jong-Kyung
    • Nuclear Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.375-384
    • /
    • 1997
  • Relative power density distributions of the Kori Unit 1 pressurized water reactor are calculated by Monte Carlo modeling with the MCNP code. The Kori Unit 1 core is modeled on a three-dimensional representation of the one-eighth of the reactor in-vessel component with reflective boundaries at 0 and 45 degrees. The axial core model is based on half core symmetry and is divided into four axial segments. Fission reaction density in each rod is calculated by following 100 cycles with 5,000 test neutrons in each cycle after starling with a localized neutron source and ten noncontributing settle cycles. Relative assembly power distributions are calculated from fission reaction densities of rods in assembly. After 100 cycle calculations, the system converges to a k value of 1.00039 $\geq$ 0.00084. Relative assembly power distribution is nearly the same with that of the Kori Unit 1 FSAR. Applicability of the full-scope Monte Carlo simulation in the power distribution calculation is examined by the relative root moan square error of 2.159%.

  • PDF

저항형 초전도 한류기를 위한 배전개통의 모델링과 적용 (Distribution System modeling and Application for HTS Resistor type FCL)

  • 최흥관;윤재영;김종율;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.250-252
    • /
    • 2002
  • Nowadays, one of the serious Problems in KEPCO system is the more higher fault current than the SCC(Short Circuit Capacity) of circuit breaker. There are many alternatives to reduce the increased fault current. As the superconductivity technology has been develops, the HTS-FCL(High Temperature Superconductor-Fault Current Limiter) can be a one of the attractive alternatives to solve the fault current problem. Under the this background, this paper presents distribution system EMTDC modeling and the application of EMTDC model for resistance type HTS-FCL in the developed distribution system model.

  • PDF

와이퍼 블레이드의 누름압 해석 (Contact Pressure Analysis of a Windshield Wiperblade)

  • 이병수;신진용
    • 한국자동차공학회논문집
    • /
    • 제14권3호
    • /
    • pp.51-57
    • /
    • 2006
  • The contact pressure distribution between a rubber wiper blade and a glass windshield is a major factor for wiping performance. A modeling and simulation method has been developed to forecast the contact pressure distribution on a wiper blade. For modeling multi-body dynamics of an wiper linkage system and flexible nature of wiper blade, ADAMS and ADAMS/flex are employed. A simulation study has been also conducted to obtain contact pressure distribution. Comparison between simulation and measurement is provided to ensure fidelity of the model and the simulation method.

DSTATCOM의 순시 유효전력 보상을 이용한 선로의 전류 개선 (Improvement of line Current using Instantaneous Real Power Compensation of DSTATCOM)

  • 정수영;김태현;문승일;권욱현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권7호
    • /
    • pp.327-332
    • /
    • 2002
  • In this paper, conventional reactive power compensation is defined and instantaneous real control concept for shunt converters is proposed. This equipment incorporates the compensation function of harmonics at the distribution line by nonlinear load. These methodologies are applied to IEEE 13 distribution system with the modeling of nonlinear load using EMTEDC/PSCAD package. Simulation with EMTDC results presented to confirm that the new approach has better performance than those obtained by controllers based on traditional concepts of reactive power compensation.

EMTDC를 이용한 DSTATCON 설치 효과 분석 (Analysis of System Performance on DSTATCON Installation using EMTDC)

  • 유일도;최영준;홍순옥;이학성;전영수;이기선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.943-945
    • /
    • 1998
  • This paper presents a method of modeling of DSTATCON (Distribution-line Static Condenser) for installation in a specific plant and analyze the effectiveness of the DSTATCON from the viewpoints of voltage regulation and harmonic mitigation in a distribution line. For the reliable modeling, detailed information on distribution system and loads is performed by field measurements. The DSTATCON has been modeled according to the control algorithm of real controller. The effectiveness of the DSTATCON installation is verified by simulation using EMTDC.

  • PDF

Analysis and optimal design of fiber-reinforced composite structures: sail against the wind

  • Nascimbene, R.
    • Wind and Structures
    • /
    • 제16권6호
    • /
    • pp.541-560
    • /
    • 2013
  • The aim of the paper is to use optimization and advanced numerical computation of a sail fiber-reinforced composite model to increase the performance of a yacht under wind action. Designing a composite-shell system against the wind is a very complex problem, which only in the last two decades has been approached by advanced modeling, optimization and computer fluid dynamics (CFDs) based methods. A sail is a tensile structure hoisted on the rig of a yacht, inflated by wind pressure. Our objective is the multiple criteria optimization of a sail, the engine of a yacht, in order to obtain the maximum thrust force for a given load distribution. We will compute the best possible yarn thickness orientation and distribution in order to minimize the total fiber volume with some displacement constraints and in order to leave the most uniform stress distribution over the whole structure. In this paper our attention will be focused on computer simulation, modeling and optimization of a sail-shape mathematical model in different regatta and wind conditions, with the purpose of improving maneuverability and speed made good.