• 제목/요약/키워드: distribution characteristics of PCBs

검색결과 14건 처리시간 0.025초

입자상 PCBs 건식침적량과 입경분포 특성: 1999년 가을 측정 (Characteristics of the dry deposition fluxes and ambient particl size distributions of PCBs: The measurements on fall, 1999)

  • 신혜정;김용표;이승묵
    • 한국입자에어로졸학회지
    • /
    • 제5권4호
    • /
    • pp.179-188
    • /
    • 2009
  • The dry deposition fluxes of particulate polychlorinated biphenyls (PCBs) were measured along with their mass size distributions at Seoul and Incheon in fall in 1999. The dry deposition fluxes of PCBs were in the range of $16.7{\sim}62.2ng/m^2/day$. The ambient concentrations of particulate PCBs were in the range of 0.07 to $0.20ng/m^3$. Generally, the mass size distribution of particulate PCBs shows bi-modal distribution. The mass fraction of PCBs in the fine particle fraction ($D_p<2.1 {\mu}m$) was over than 55% of the total PCBs concentrations. It was found that Seoul and Incheon were not the major source of PCBs emissions in Korea. Based on the comparison with the measurement data in summer, 1999, it is likely that both the dry deposition fluxes and ambient particulate PCBs concentrations were not site-specific.

  • PDF

Measurement of Atmospheric Dry Deposition and Size Distribution of Particulate PCBs in 1999 at Seoul

  • Park, Seong-Suk;Shin, Hye-Joung;Yi, Seung-Muk;Kim, Yong-Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제22권E1호
    • /
    • pp.35-43
    • /
    • 2006
  • Ambient particle size distributions of PCBs and their dry deposition fluxes were measured at a site in Seoul to quantify dry deposition fluxes of PCBs and size characteristics of PCBs in the air, and to estimate ambient concentrations of gaseous PCBs and dry deposition fluxes. The dry deposition plate was used to measure dry deposition fluxes of particulate mass and PCBs and a cascade impactor and rotary impactor were used to measure ambient particle size distributions for small ($D_p<9{\mu}m$) and large ($D_p>9{\mu}m$) particles, respectively. Six sample sets were collected from April to July 1999. The fluxes of particulate total PCBs (the sum of 43 congeners) ranged from 160 to $607ng\;m^{-2}day^{-1}$. The size distribution of total PCBs was bimodal with two peaks in small particle size ($D_p{\sim}0.6\;and\;6{\mu}m$, respectively) and, thus, mass concentration being dominant in small particles. The mean particulate PCBs concentration was $6.9{\mu}g$ PCBs/g. The concentrations of PCB homologues in the gas phase were estimated based on the particle/gas partition coefficient ($K_p$) with the measured values of particulate PCBs in this study and they were comparable to those observed in other previous studies. Dry deposition fluxes were estimated by calculating dry deposition velocities.

동해남부 대마난류계에서의 염소화 Biphenyls의 분포특성 (Distribution Chara Cteristics of Polychlorinated Biphenyls in the Southern Korea)

  • 이동인;옥곤;양한섭;장윤석
    • 한국수산과학회지
    • /
    • 제30권4호
    • /
    • pp.679-686
    • /
    • 1997
  • 본 연구조사는 동해남부 대마난류계에서의 PCBs의 분포특성을 파악하기 위하여 1996년 8월과 10월에 걸쳐 5개 정점을 선정하여 각 정점의 수심별의 수온, 염분 및 용존산소를 측정하여 수괴 분석을 실시하였으며, 또한, 각 정점별, 수심별의 PCBs의 분석을 실시하였다. 수괴의 분포특성을 조사한 결과 수온 및 염분약층은 수심 30m부분에 존재하고 있었으며, 대마난류 중층수는 30m이하로 간주되었으며, 대마난류의 표층수는 한국근해에서 대마도쪽으로 확장되는 양상을 보였다. PCBs의 분석결과 표층수는 8월의 경우 대마도쪽으로 갈수록 농도가 약간 낮아지는 경향을 보이다가, 대마도쪽에서 다시 약간의 증가경향이 관찰되었다. 표층 해수중에서의 PCBs의 평균농도는 $0.29\;ng/\ell$정도 였으며, 중층에서의 평균농도는 $0.31\;ng/\ell$정도로 표층에 비교하여 중층에서의 농도가 약간 증가하는 것으로 나타났다. 해수중 PCBs의 농도는 부유물질의 농도변화 경향과 유사성을 나타났으며, 농도의 수평 및 연직변화는 그다지 크게 나타나지 않아 비교적 균일한 농도분포를 나타내고 있었다. 해수의 수심별 PCBs의 상대농도 조성비는 표층에서 Di- 및 Tri-PCBs의 비율이 높았지만, 심층으로 갈수록 Peta-PCBs의 상대농도 조성비율이 높은 것으로 나타나, 수심의 변화에 따른 PCBs의 구성비와 소실에 차이가 있는 것으로 사료된다.

  • PDF

낙동강 유역에 서식하는 붕어와 황소개구리 체내의 Polychlorinated biphenyls의 축적도와 분포특성 (Accumulation Levels and Distribution Characteristics of Polychlorinated Biphenyls in Crucians and Leopard Frogs from the Nakdong River Basin)

  • 문지용;이성인;송희영;이경진;최경희;정기호
    • 분석과학
    • /
    • 제17권4호
    • /
    • pp.347-354
    • /
    • 2004
  • 본 연구에서는 낙동강과 그 유역에 서식하는 붕어와 황소개구리 체내의 polychlorinated biphenyls (PCBs)의 축적도와 분포특성을 조사하였다. 낙동강의 구미부터 하구언까지 모두 5개 지점에서 붕어와 황소개구리를 채집하였으며, 이들의 근육 부분을 최종 분석시료로 하였다. PCBs의 정량분석은 GC-MSD 시스템으로 처리하였으며, PCBs 총농도를 대변할 수 있는 62개 congener를 분석항목으로 선정하였다. 붕어에서는 모두 24개의 congener가 검출되었고 총 PCBs 농도는 0.74~5.41 ng/g wet weight 범위로 나타났다. 황소개구리에서는 낙동강 하구언 1개 지점에서 단지 2개의 congener가 검출되었고 그 농도도 0.24 ng/g wet weight로서 붕어보다 약 22배 정도 낮게 검출되었다. 전체적으로, PCB 153이 가장 높게 검출된 congener이고, penta- 및 hexa-CBs가 총 PCBs의 78%를 차지하였다.

The Distribution Characteristics of Polychlorinated Biphenyls in Rural Atmosphere

  • Yeo, Hyun-Gu;Park, Minkyu;Chun, Man-Young;Young Sunwoo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제18권E3호
    • /
    • pp.143-151
    • /
    • 2002
  • Atmospheric concentrations of polychlorinated biphenyl (PCB) congeners were measured every two weeks from July, 1999 to January, 2000 at Hankyong University in Ansung, Kyounggi-do. Atmospheric concentrations of ∑$_{24}$PCB showed a range of 19.8~71.9 pg/m3. The highest concentration of PCB homolog was tri-CBs (sum of PCB 18, 27, 28, 33, 38) which had a comparatively higher vapor pressure than other homologs. The contribution ratio of lighter PCB homologs (tri-CBs) to total PCBs was 44.5%, and these homologs were the main components of PCBs. The ratio PCB homologs/deca-CB (PCB 209) suggested that the contribution of vapor phase PCBs increased greatly in summer relative to other seasons. In addition, the regression lines for PCB homologs/deca-CB (PCB 209) and temperature ($^{\circ}C$) appeared as an exponential function with high correlation (R2>0.67, p< 0.01). This suggests that the concentration of vapor phase PCB homologs increases steeply with increasing temperature.

주요 하천 및 호수에 서식하는 붕어 (Carassius auratus and Carassius cuvieri) 근육에 축적된 2,3,7,8-치환 PCDDs, PCDFs 및 DL-PCBs 분석 (Analysis of 2,3,7,8-substituted PCDDs, PCDFs, and DL-PCBs in muscle of crucian carp (Carassius auratus and Carassius cuvieri) from major rivers and lakes)

  • 정기호;문지용;문동호
    • 분석과학
    • /
    • 제24권6호
    • /
    • pp.484-492
    • /
    • 2011
  • 우리나라 주요 하천수계의 대표적인 지점 한 곳씩 선정하여 이곳에 서식하는 붕어에 대한 PCDDs, PCDFs 및 DL-PCBs의 체내 축적 정도를 분석하고 분포특성을 살펴보았다. 회수율은 PCDDs 및 PCDFs는 50.6%~88.3%, DL-PCBs는 52.3%~93.2%이었으며, 붕어 체내에 축적된 PCDDs, PCDFs 및 DL-PCBs를 모두 합한 ${\sum}$dioxins은 평균 0.39 pg TEQ $g^{-1}$ wet wt., 중앙값 0.14 pg TEQ/g wet wt., 그리고 농도 범위는 0.047-1.0 pg TEQ/g wet wt.으로 나타났다. PCDDs 및 PCDFs는 일부 시료에서 검출된 반면, DL-PCBs는모든 시료에서 검출되었으며 ${\sum}$dioxins에 대한 기여도가 83.6%로서 가장 높았다. 다음으로 PCDFs와 PCDDs가 각각 ${\sum}$dioxins의 12.7%와 3.7%를 기여하고 있었다.

폐 PCBs의 미분쇄 공정 적용에 따른 유가금속 분포 특성 및 금속 침출 향상에 관한 연구 (A Study on Improvement of Valuable Metals Leaching and Distribution Characteristics on Waste PCBs(Printed Circuit Boards) by Using Pulverization Process)

  • 한영립;최영익
    • 한국환경과학회지
    • /
    • 제24권2호
    • /
    • pp.245-251
    • /
    • 2015
  • The main objective of this study is to recovery valuable metals with metal particle size distributions in waste cell phone PCBs(Printed Circuit Boards) by means of pulverization and nitric acid process. The particle size classifier also was evaluated by specific metal contents. The PCBs were pulverized by a fine pulverizer. The particle sizes were classified by 5 different sizes which were PcS1(0.2 mm below), PcS2(0.20~0.51 mm), PcS3(0.51~1.09 mm), PcS4(1.09~2.00 mm) and PcS5(2.00 mm above). Non-magnetic metals in the grinding particles were separated by a hand magnetic. And then, Cu, Co and Ni were separated by 3M nitric acid. Particle diameter of PCBs were 0.388~0.402 mm after the fine pulverizer. The sorting coefficient were 0.403~0.481. The highest metal content in PcS1. And the bigger particle diameter, the lower the valuable metals exist. The recovery rate of the valuable metals increases in smaller particle diameter with same leaching conditions. For further work, it could improve to recovery of the valuable metals effectively by means of individual treatment, multistage leaching and different leaching solvents.

제주항내 퇴적물의 PCBs 분포특성 (Distribution Characteristics of Polychlorinated Biphenyls in Sediments inside Jeju Harbor)

  • 허륜용;감상규;조은일
    • 해양환경안전학회지
    • /
    • 제22권2호
    • /
    • pp.220-227
    • /
    • 2016
  • 본 연구에서는 제주도에서 규모가 가장 큰 항구인 제주항내 퇴적물을 대상으로 PCBs의 분포특성을 연구하였다. 연구 결과, 제주항 내 표층퇴적물에서 PCBs 화합물의 농도범위는 1.62~4.45 ng/g dw로 낮은 농도로 분포하고 있었고, PCBs의 동족체 패턴 분석을 보면 제주항은 선박 활동으로 유래되는 고염소화된 CBs(Hexa-CBs 이상)이 주로 분포하였다. 퇴적물에서 PCBs 화합물의 분포에 미치는 유기물의 영향을 평가하기 위하여 퇴적물 내 유기탄소 함량과 PCBs 화합물의 농도와의 상관관계를 검토한 결과, $R^2$이 0.8387로 높게 나타나 유기탄소 함량과 PCBs 농도는 매우 유의한 상관성을 보이는 것을 알 수 있었다. PCBs 화합물의 농도분포와 입자크기와의 관계에서 역질, 사질, 니질로 나누어 조사하였는데 니질의 함량이 증가할수록 PCBs의 농도도 높게 분포하였다. 그리고 연구지역의 표층퇴적물에서 분포하고 있는 PCBs의 농도를 국외에서 적용하고 있는 퇴적물오염기준(sediment quality guidenes, SQGs)의 ERL(effect range-low)과 TEL(Threshold Effects Level) 값과 비교한 결과, 훨씬 낮은 값을 보여 생태독성학적 관점에서 저서생물에 미치는 영향은 미미한 것으로 사료된다.

충격형 분쇄기 에 의한 폐프린트배선기판(PCBs) 중 금속성분의 분쇄 특성 (The Grinding Characteristics of the Metal Components in Printed Circuit Boards(PCBs) Scrap by the Swing-Hammer Type Impact Mill)

  • 이재천;길대섭;남철우;최철준
    • 자원리싸이클링
    • /
    • 제11권2호
    • /
    • pp.28-35
    • /
    • 2002
  • 충격형 분채기에 의한 폐프린트배선기판(PCBs)의 분쇄과정에서 일어나는 금속성분의 분쇄특성에 대한 연구가 수행되었다. PCBs로부터 금속성분들을 단체분리하기 위하여 -3 mm로 파쇄한 다음 충격형 분쇄기를 사용하여 분쇄하였으며 햄머의 회전속도가 금속성분의 분쇄에 미치는 영향을 관찰하였다. 동과 땜납 등과 같은 금속성분들의 입도분포 및 단체분리도를 조사하였다. 경사진동판을 사용하는 PCBs 분쇄물로부터 금속입자들의 형상분리에서 햄머의 회전속도와 입자크기가 미치는 영향을 검토하였다 61.3 m/s 햄머속도에서 동 성분은 +297$\mu$m 입자가 80% 이었지만 땜납성분은 -297$\mu$m 입자가 90%에 달했다. 형상분리법에 의한 금속입자의분리 시 햄머의 회전속도가 클수록 회수위치가 짧았으며 +297 $\mu$m 입자의 회수위치가 -297~+149$\mu$m 입자보다 짧았다. 회수위치가 짧을수록 금속입자의 구형도가 좋았으며 KI 값은 KI=1 로 증가하고, $\phi_{c}$ 값은 $\phi_{c}$ =1로 감소하였다.

하천 퇴적물 중 PCBs 농도분포 및 발생원 해석 (The Concentration Distribution and Source Identification of Polychlorinated Biphenyls in River Sediment)

  • 김영호;오정근;김종국;김경수
    • 대한환경공학회지
    • /
    • 제32권11호
    • /
    • pp.995-1000
    • /
    • 2010
  • 하천 퇴적물 중 PCBs 농도수준 파악과 발생원 추정을 위해 낙동강 수계를 대상으로 21개 지점을 선정하고 지점당 3개씩 총 63개의 샘플을 분석한 결과 퇴적물 표층에서 검출된 DL-PCBs 농도분포는 3.0~6,600(평균440) pg/g-dry의 범위였고 TEQ값은