• Title/Summary/Keyword: distribution box

Search Result 441, Processing Time 0.028 seconds

A study to Find Factors of the Box Office Record in Korean Popular Music : by Control Effects of Management Companies and Distribution Companies (대중음악 흥행결정요인이 국내대중음악 흥행성과에 미치는 영향 : 기획사와 유통사의 조절효과를 중심으로)

  • Kim, Yang Sug;Lee, Sang Houck
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.1
    • /
    • pp.23-31
    • /
    • 2015
  • The purpose of this study is to find the factors of the box office record in Korean popular music. For this purpose, 1.239 musics were selected in the Gaon digital weekly album chart from second week July 2013 to first week July 2014. The result can be summarized as follows: First, entertainment of music company, distribution of music company, singer, OST(Original Sound Track), television show, SNS and high ranking in the first week of its release are the factors of the box office record in Korean popular music. Second, entertainment of a large number of music production company is more effective than the others, but there is no difference in the case of distribution music company. Third, musics of singers who have large number of music ranked Gaon digital chart and appearance of television show program are effective in the box office record in Korean popular music. Fourth, SNS are great factors to promote Korean popular music. Fifth, it is important to rank high position in the first week of its release.

  • PDF

Stress Distribution Behavior Hollow and Felled Circular Column Column-Box Beam Connections (비충전 및 충전 원형기둥-상자형보 접합부의 응력분포특성)

  • Hwang, Won Sup;Park, Yong Myung;Choi, Won Kyong;Kim, Young Pil
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.3
    • /
    • pp.433-441
    • /
    • 2002
  • This study present the stressdistribution of circular column-box beam connection in steel piers. Experiments were carried out for hollow and concrete filled connections, depending on the joint angle. To determine vertical and shear stress distribution, this study examined the equivalent web depth dc' that is mainly used in existing design equation. Lidewise, as additional equivalent web depth was introduced. Stress values that were calculated using equivalent wev depth were also compared with the test stress value. Results showed that stresses of hollow and filled connections have great differences. However, dc' has a limitation for some joint angles. Likewise, stress of filled connection was less than that of the hollow connection. The test value of filled connection was also compared with design equations that were introduced from the hollow connection.

Flow Analysis to Develop Uniform Thermal Flow Distributions of the Box Type Dryer for Agriculture Products (상자식 농수산물 건조기의 열풍 균일분배구조 실현을 위한 유동해석)

  • Eom Yong-Kyoon;Ahn Do-Won;Cheon Sung-Kook;Seo Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.7-16
    • /
    • 2006
  • Both the computational and experimental analysis have been conducted in this study to develop the high efficiency agriculture products dryer by the uniform thermal flow distribution in the drying room. It has been developed based on the results of the computation and experiment in the conventional dryer to improve the thermal flow distribution in drying room. The developed dryer can be prevented the local concentration of the heated wind and achieved the uniform flow distribution using the installation of vertical branch ducts, ribs, guide vanes and porous plates. As a result, the developed dryer reduced the fuel consumption up to $15\%$ and the electricity consumption up to $31.5\%$ compared with the conventional dryer.

Physical Properties of Corrugated Fiberboard and Estimation of Box Compression Strength with Changes of Relative Humidity (상대습도에 따른 농산물 포장용 골판지의 원지의 물리적 특성 변화 및 상자압축강도의 예측)

  • Jo, Jung-Youn;Shin, Jun-Sub;Kim, Jong-Kyoung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.11 no.2
    • /
    • pp.91-96
    • /
    • 2005
  • Determination of safety factor of corrugated fiberboard boxes used for agricultural products is very complicated process due to nature of living products. Moisture content is one of the most critical factors to determine overall physical strength of paper, so its influences on strength properties of corrugated board made from different raw materials must be quantified. The results obtained from the study were summarized as follows; 1. Results show a detrimental effect on bursting strength and compressive strength of liners with increasing relative humidity of environment and moisture content of liners. 2. The relevance of equilibrium moisture content at varying relative humidity levels was proved and its relationship was used as an important factor to estimate box compression strength. 3. Test results was statistically used for establish the relationship between relative humidity and moisture content of liners. Estimated compression strength of boxes at varying moisture content was similar to results of theoretical equations such as Kellicutt's. Further study could be carried out in order to determine a optimum safety factors of various corrugated board boxes for agricultural products.

  • PDF

Prediction of spatial distribution of air pollutants within tunnel (터널 내 대기오염물질의 공간분포 예측)

  • Park, Il-Gun;Hong, Min-Sun;Kim, Beom-Seok;Kang, Ho-Geun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.6
    • /
    • pp.607-616
    • /
    • 2012
  • The need for management of tunnel air quality is imminent considering the rapid increase of number and span of tunnels in Korea. To investigate spatial distribution of $CO_2$ within tunnels, $CO_2$ were measured and model simulations were performed in Namsan 1 tunnel. Results show that $CO_2$ concentrations were 250 ppm to 400 ppm higher in the exit than tunnel entrance. Also, $CO_2$ concentrations were 200 ppm to 300 ppm lower inside no ventilating vehicle than in the tunnel. Both experimental and model simulation results show that spatial distribution and concentration gradient of air pollutant inside tunnel are highly dependent on traffic density.

Properties and Fractal Analysis of Joints around the Moryang Fault (모량단층 주변 절리의 분포 특성과 프랙탈 해석)

  • 최한우;장태우
    • The Journal of Engineering Geology
    • /
    • v.9 no.2
    • /
    • pp.119-134
    • /
    • 1999
  • Joints developed around the Moryang fault were investigated by traverse and inventory methods in order to characterize their orientation, spacing and density. The results of the traverse method show that the orientation of the dominant joint sets of the study area is NNE and EW, and that joint spacing distribution is a negative exponential distribution to the center of the fault and a log-normal distribution to the margin of the fault. The results of the inventory method show that the orientation of the dominant joint sets on joint map is NW and NE, and that joint density tends to increase toward the center of the fault. Fractal dimension was determined by using Box-counting method and Cantor's dust method to quantify the distribution of joint network and to evaluate the dimension around the fault. The dimension determined by Box-counting method ranges from 1.31 to 1.70 and shows the tendency of increasing value toward the center of the fault. Comparing fractal dimension by Box-counting method with joint density, fractal dimension is directly proportional to joint density. Nevertheless, fractal dimension could be varied due to the different distribution patterns of the joints with same density. The dimensions determined by Cantor's dust method show different values with respect to the orientation of scan lines. This results form the anisotropy of joint distribution.

  • PDF

A Fundamental Study on Effective Width Evaluation of Laminated Composite Box Girder (복합적층 박스거더의 유효폭 산정을 위한 기초연구)

  • Chun, Kyoung-Sik;Ji, Hyo-Seon;Park, Won-Tae
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.3
    • /
    • pp.26-31
    • /
    • 2015
  • The domestic and foreign specifications presented the effective width based on flange length to width ratio only. The existing paper on the effective width grasped of the effect of span, load type and cross-section properties, but localized steel bridges. Recently, The studies are going on in progress for the application of fiber reinforced composite material in construction field. Therefore, it is required to optimum design that have a good grasp the deformation characteristic of the displacements and stresses distribution and predict variation of the effective width for serviceability loading. This research addresses the effective width of all composite material box girder bridges using the finite element method. The characteristics of the effective width of composite structures may vary according to several causes, e.g., change of fibers, aspect, etc. Parametric studies were conducted to determine the effective width on the stress elastic analysis of all composite materials box bridges, with interesting observations. The various results through numerical analysis will present an important document for construct all composite material bridges.

Seismic performances of three- and four-sided box culverts: A comparative study

  • Sun, Qiangqiang;Peng, Da;Dias, Daniel
    • Geomechanics and Engineering
    • /
    • v.22 no.1
    • /
    • pp.49-63
    • /
    • 2020
  • Studying the critical response characteristics of box culverts with diverse geometrical configurations under seismic excitations is a necessary step to develop a reasonable design method. In this work, a numerical parametric study is conducted on various soil-culvert systems, aiming to highlight the critical difference in the seismic performances between three- and four-sided culverts. Two-dimensional numerical models consider a variety of burial depths, flexibility ratios and foundation widths, assuming a visco-elastic soil condition, which permits to compare with the analytical solutions and previous studies. The results show that flexible three-sided culverts at a shallow depth considerably amplify the spectral acceleration and Arias intensity. Larger racking deformation and rocking rotation are also predicted for the three-sided culverts, but the bottom slab influence decreases with increasing burial depth and foundation width. The bottom slab combined with the burial depth and structural stiffness also significantly influences the magnitude and distribution of the dynamic earth pressure. The findings of this work shed light on the critical role of the bottom slab in the seismic responses of box culverts and may have a certain reference value for the preliminary seismic design using R-F relation.

3D FE modeling considering shear connectors representation and number in CBGB

  • Abbu, Muthanna A.;Ekmekyapar, Talha A.;Ozakca, Mustafa A.
    • Steel and Composite Structures
    • /
    • v.17 no.3
    • /
    • pp.237-252
    • /
    • 2014
  • The use of composite structures is increasingly present in civil building works. Composite Box Girder Bridges (CBGB), particularly, are study of effect of shear connector's numbers and distribution on the behavior of CBGBs is submitted. A Predicti structures consisting of two materials, both connected by metal devices known as shear connectors. The main functions of these connectors are to allow for the joint behavior of the girder-deck, to restrict longitudinal slipping and uplifting at the element's interface and to take shear forces. This paper presents 3D numerical models of CBGBs to simulate their actual structural behavior, with emphasis on the girder-deck interface. Additionally, a Prediction of several FE models is assessed against the results acquired from a field test. A number of factors are considered, and confirmed through experiments, especially full shear connections, which are obviously essential in composite box girder. A good representation for shear connectors by suitable element type is considered. Numerical predictions of vertical displacements at critical sections fit fairly well with those evaluated experimentally. The agreement between the FE models and the experimental models show that the FE model can aid engineers in design practices of box girder bridges. Preliminary results indicate that number of shear studs can be significantly reduced to facilitate adoption of a new arrangement in modeling CBGBs with full composition. However, a further feasibility study to investigate the practical and economic aspects of such a remedy is recommended, and it may represent partial composition in such modeling.

Flexural behaviors of full-scale prestressed high-performance concrete box girders

  • Gou, Hongye;Gu, Jie;Ran, Zhiwen;Bao, Yi;Pu, Qianhui
    • Structural Engineering and Mechanics
    • /
    • v.75 no.5
    • /
    • pp.595-605
    • /
    • 2020
  • In this study, the flexural behaviors of full-scale prestressed concrete box girders are experimentally investigated. Four girders were fabricated using two types of concrete (compressive strengths: 50 MPa and 70 MPa) and tested under four-point bending until failure. The measured parameters included the deflection, the stress and strain in concrete and steel bars, and cracks in concrete. The measurement results were used to analyze the failure mode, load-bearing capacity, and deformability of each girder. A finite element model is established to simulate the flexural behaviors of the girders. The results show that the use of high-performance concrete and reasonable combination of prestressed tendons could improve the mechanical performance of the box girders, in terms of the crack resistance, load-carrying capacity, stress distribution, and ductility.