• 제목/요약/키워드: distribution of particle size

검색결과 1,934건 처리시간 0.028초

An Approach to the Influence of Particle Size Distribution of Leuco Vat Dye Converted by a Reducing Agent

  • Shim Woo-Sub;Lee Jung-Jin;Shamey Renzo
    • Fibers and Polymers
    • /
    • 제7권2호
    • /
    • pp.164-168
    • /
    • 2006
  • Three vat dyes have been applied to regular viscose rayon and their dyeing and wash fastness properties were evaluated. Particle size determination was undertaken to obtain information about the size of dye particles converted by a reducing agent, to see if dye particle size has an affect on dyeing properties of regular viscose rayon. It is observed that viscose rayon exhibits more dyeability with reducing agent concentrations between 5-7.5 g/l. Also, we found that the vat dyeing system is greatly affected by the particle size of the vat dye converted to leuco form by a reducing agent.

기-고 유동층에서 Gaussian 분포 입자군의 표준편차에 따른 유출 특성 (The Characteristics of Elutriation with Gaussian Particle Size Distributions in a gas-solid fluidized bed)

  • 장현태;차왕석
    • 한국산학기술학회논문지
    • /
    • 제10권11호
    • /
    • pp.3274-3279
    • /
    • 2009
  • 기-고 유동층에서 다입자경 입자의 입자분포 변화에 따른 비산유출 특성을 연구하였다. 다입자경 입자분포는 Gaussian 분포를 사용하여 실험을 수행하였다. 최소유동화속도에 대한 유속비와 Gaussian 입자분포의 표준편차에 따른 비산유출상수를 구하였으며, 이때 조업시간에 따른 압력요동의 특성치를 구하였다. 측정된 유동층의 압력요동 특성치로부터 압력요동의 표준편차, 평균압력, Power spectrum density function, 주진동수 등을 계산하였다. 입자분포군에 따라서 유출입자의 입자분포 및 압력요동 특성치는 크게 영향을 받는 것으로 나타났으며 이러한 결과로부터 압력요동 특성치로부터 유출특성의 해석이 가능함을 알 수 있었다.

축류형 사이클론을 이용한 공기역학경과 광학직경 상관관계 분석에 관한 연구 (A Study on Correlation Analysis between Aerodynamic Diameter and Optical Diameter Using Axial Flow Cyclone)

  • 김은정;박경려;허지은;조철희;조윤행
    • 한국입자에어로졸학회지
    • /
    • 제19권4호
    • /
    • pp.155-164
    • /
    • 2023
  • APS (Aerodynamic Particle Sizer) and OPC (Optical Particle Counter) have been widely used to real-time measurement of indoor and outdoor aerosols. The APS measures the size distribution based on an aerodynamic diameter, while the OPC uses optical diameter to measure the size distribution of aerosols. Since obtaining a size distribution based on aerodynamic diameter is important to understand aerosol characteristics, lots of researcher had been developed experimental equations which can convert optical diameter into aerodynamic diameter. However, previous studies have conducted repeated experiments on particles having a single diameter. In this study, an experimental method of converting optical diameter into aerodynamic diameter through a single experiment was presented. The collection efficiencies of an axial cyclone were measured using APS and OPC at the same time, and the correlation equation between aerodynamic diameter and optical diameter was driven through a theoretical model. Using the proposed method, the size distribution of NaCl particles measured by OPC showed a high correlation with the size distribution obtained by APS (0.93 of R-squared value). In the tests conducted on ISO A1, A2, and A4 test particles, the converted OPC size distribution tended to be similar to the APS size distribution, and for each of test particles (ISO A1, A2, and A4), the R-squared values for the APS particle size distribution were 0.75, 0.86, and 0.89, respectively.

후처리 장치에 의한 디젤엔진 배출가스의 미세 입자 입경분포 변화 (Influence of Aftertreatment System on the Size Distribution of Diesel Exhaust Particulate Matter)

  • 권순박;김민철;이규원;류정호;엄명도;김종춘;정일룩
    • 한국자동차공학회논문집
    • /
    • 제7권7호
    • /
    • pp.113-121
    • /
    • 1999
  • Diesel particulate matter is known to be one of the major harmful emissions produced by diesel engines. Diesel particulates are subject to diesel emission regulations and have lately become the focus in the diesel emission control technology. Thus, the aftertreatment system is adopted at the diesel engine exhaust to reduce the particulate emission. Although this benefit is recognized, it is not clear how the aftertreatment system influences quantitatively the particle size distribution distribution. In this study, the particle size distributions of diesel exhaust were measured using the scanning mobility particle sizer with and without the aftertreatment system. There results showed that the diesel particulate filter and plasm system reduced the number of emitted particles by more than 90% and about 80% respectivley in the particle size range of 20nm∼600nm. On the other hand no significant effect of the diesel oxidation catalyst on the particle number concentration was detected.

  • PDF

Tethered-Balloon Package System 개발 및 대기 에어로졸의 연직 분포 측정 (Development of Tethered-Balloon Package System for Vertical Distribution Measurement of Atmospheric Aerosols)

  • 은희람;이홍규;이양우;안강호
    • 한국입자에어로졸학회지
    • /
    • 제9권4호
    • /
    • pp.253-260
    • /
    • 2013
  • For a vertical atmospheric aerosol distribution measurement, a very compact and light particle sampling package is developed. This package includes a compact optical particle counter (Hy-OPC), a light and small condensation particle counter (Hy-CPC), sensors (GPS, wind velocity, temperature, humidity), and a communication and system control board. This package is attached to He balloon and the altitude is controlled by a winch. Using this system the vertical particle size distribution was measured. The test results showed that the ground base atmospheric particle measurement result may be a lot different from that high above the ground.

입자크기분포 설정 및 멀티스레딩을 통한 소외사고영향분석 최적화 타당성 평가 (Feasibility Study on the Optimization of Offsite Consequence Analysis by Particle Size Distribution Setting and Multi-Threading)

  • 김승환;김성엽
    • 한국안전학회지
    • /
    • 제39권1호
    • /
    • pp.96-103
    • /
    • 2024
  • The demand for mass calculation of offsite consequence analysis to conduct exhaustive single-unit or multi-unit Level 3 PSA is increasing. In order to perform efficient offsite consequence analyses, the Korea Atomic Energy Research Institute is conducting model optimization studies to minimize the analysis time while maintaining the accuracy of the results. A previous study developed a model optimization method using efficient plume segmentation and verified its effectiveness. In this study, we investigated the possibility of optimizing the model through particle size distribution setting by checking the reduction in analysis time and deviation of the results. Our findings indicate that particle size distribution setting affects the results, but its effect on analysis time is insignificant. Therefore, it is advantageous to set the particle size distribution as fine as possible. Furthermore, we evaluated the effect of multithreading and confirmed its efficiency. Future optimization studies should be conducted on various input factors of offsite consequence analysis, such as spatial grid settings.

조리과정에서 생성된 미세먼지의 크기분포 특성 (Size Distribution Characteristics of Particulate Matter Emitted from Cooking)

  • 주상우;지준호
    • 한국입자에어로졸학회지
    • /
    • 제16권1호
    • /
    • pp.9-17
    • /
    • 2020
  • The characteristics of particulate matter made from daily cooking at a Korean residential apartment house with three dwellers had been investigated for about 3 months. All data were recorded by an optical particle counter every minute at the kitchen. Types of cooking such as boiling, frying, and grilling that performed in the house were listed. Boiling only was used in 32% cases among total 234 meals. Frying and grilling were 14% and 11%, respectively. From an initial indoor particulate matter smaller than 10 ㎛ in diameter, the increases due to cooking are reported by size. In case of boiling, PM at 1-10 ㎛ size and under 1 ㎛ size little increased. Normally, particles from oil or combustion in a process of frying or grilling increased indoor PM. In a case of grilling, particle mass concentration in a region of 1-10 ㎛ in diameter increased as much as 295 ㎍/㎥. Mass concentration of particles smaller than 1 ㎛ increased as much as 33 ㎍/㎥.

충격식 코로나 방전 플라즈마를 이용한 배연가스로부터 먼지제거에 대한 특성 (The Characteristics of Dust Removal in Flue Gas by the Plasma of Impulse Streamer Corona)

  • 김은호
    • 한국환경과학회지
    • /
    • 제12권12호
    • /
    • pp.1261-1267
    • /
    • 2003
  • On the basis of the distribution of particle size measured by laser diffraction spectrometers, this research was carried out to investigate the characteristics of mist removal with the change of operating condition in the plasma reactor of impulse streamer corona. The operating parameters in this experiment were power of impulse streamer corona, gas velocity, impulse generation time, gas temperature, and SOx/NOx concentration. The collection efficiency T(d) was estimated by the distribution of particle size in the collection zone through the advanced model.

저온플라즈마에 의한 배연 가스내의 미스트 처리기술 (The Technology of Mist Removal in Flue Gas by the Plasma of Impulse Streamer Corona)

  • 하상안;김일배;강신묵
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.69-76
    • /
    • 1999
  • This research was carried but to investigate the characteristics of mist removal with the change of operating conditions in the plasma reactor of impulse streamer corona based on the distribution of particle size measured by laser diffraction spectrometers. The operating conditions in this experiment were power of impulse streamer corona, gas velocity, collection time, and SOx/NOx concentration. The collection efficiency T(d) was estimated by distribution of particle size in the collection zone through the advanced model.

  • PDF

Effect of Nozzle Tip Size on the Fabrication of Nano-Sized Nickel Oxide Powder by Spray Pyrolysis Process

  • Kim, Donghee;Yu, Jaekeun
    • 한국재료학회지
    • /
    • 제23권9호
    • /
    • pp.489-494
    • /
    • 2013
  • In this study, by using nickel chloride solution as a raw material, a nano-sized nickel oxide powder with an average particle size below 50 nm was produced by spray pyrolysis reaction. A spray pyrolysis system was specially designed and built for this study. The influence of nozzle tip size on the properties of the produced powder was examined. When the nozzle tip size was 1 mm, the particle size distribution was more uniform than when other nozzle tip sizes were used and the average particle size of the powder was about 15 nm. When the nozzle tip size increases to 2 mm, the average particle size increases to roughly 20 nm, and the particle size distribution becomes more uneven. When the tip size increases to 3 mm, particles with an average size of 25 nm and equal to or less than 10 nm coexist and the particle size distribution becomes much more uneven. When the tip size increases to 5 mm, large particles with average size of 50 nm partially exist, mostly consisting of minute particles with average sizes in the range of 15~25 nm. When the tip size increases from 1 mm to 2 mm, the XRD peak intensities greatly increase while the specific surface area decreases. When the tip size increases to 3 mm, the XRD peak intensities decrease while the specific surface area increases. When the tip size increases to 5 mm, the XRD peak intensities increase again while the specific surface area decreases.