• Title/Summary/Keyword: distributed power conversion

Search Result 75, Processing Time 0.03 seconds

Development of an Real-time Multi-machine Power System Simulator using Personal Computers and Fast Ethernet (개인용 컴퓨터와 고속 이더넷을 이용한 다기 다모선 전력 시스템 실시간 시뮬레이터 개발에 관한 연구)

  • Kim, Joong-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.63-68
    • /
    • 2009
  • As the complexity of the power system becomes higher, tests of the new devices, such as exciter and PCS(Power Conversion System) of the distributed generation sources, in the real operating condition are more important. However tests of the unverified devices in the real power system may cause hazardous malfunction of the system. In order to avoid this problem, power devices may be tested with the real-time simulators instead of the real power system. This paper presents an real-time multi machine power system simulator using PCs(Personal Computer) and Fast Ethernet. Developed real-time simulator performs the electro-mechanical dynamic simulation of multi-machine power system by the network distributed computing technique. Because the simulator consists of usual PCs and Fast Ethernet, it is possible to make up a simulation system very cheaper than the conventional real-time simulator which consists of dedicated expensive hardware devices. The performance of the developed simulator is tested and verified with the scaled model excitation system. The test which adjust the control parameters of the exciter is performed with the well-known New England 10 generator 39 bus sample power system.

LED Driver Circuit using Distributed Power Conversion (분산형 전력변환을 이용한 LED 구동 회로)

  • Kim, Sang-Eon;Roh, Chung-Wook
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.333-334
    • /
    • 2012
  • 본 논문은 LED 구동회로에서 DC/DC 컨버터회로를 분산하여 저발열, 부피저감이 가능한 새로운 구조의 LED 구동회로를 제안한다. 제안된 회로의 특징은 기존 벅컨버터에서 발열이 높고 부피가 큰 부품들을 제거하여 발열을 낮추고 부피를 줄이는 효과가 있다. 또한 전력을 분산시킴으로써 기존회로보다 소자의 전압, 전류스트레스가 감소한다. 제안한 회로를 검증하기 위해 이론적 분석결과를 통해 타당성을 검토하였고 전장용 LED 구동회로에 적용하여 실험을 통해 우수성을 검증하였다.

  • PDF

An Experimental and Numerical Analysis on Performance Comparison of a Trigeneration Desiccant System and Conventional Air-conditioning System (Trigeneration 제습공조시스템과 일반공조시스템의 성능 비교 실험 및 수치해석)

  • Kim, Hyoung-Tae;Chae, Jungmin;Cho, Young-Ah;Park, So-jin;Song, Geun-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.32-37
    • /
    • 2018
  • Recently, the distributed power generation market using natural gas is expected to expand gradually according to the government's future energy conversion policy. Distributed power generation means small power generation source near the power demand site, which has the advantage of reducing the construction costs of the transmission and distribution infrastructure, operating cost and power loss. A typical example of distributed generation using natural gas is the trigeneration system. In this study, we conducted a basic study on the performance analysis of trigeneration desiccant system for dehumidifying / cooling / heating in the air conditioner room by using the cold and engine waste heat energy generated in the trigeneration system. It shows that the system efficiency increases and the energy consumption decreases as the temperature difference between the inlet and outlet of the trigeneration system increases compared with the general air conditioning system.

Analysis and Design of a New Topology of Soft-Switching Inverters

  • Chen, Rong;Zhang, Jia-Sheng
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.51-58
    • /
    • 2013
  • This paper proposes the power conversion mechanism of a bailer-charge-transfer zero-current-switching (CT-ZCS) circuit. The operation modes are analyzed and researched using state trajectory equations. The topology of CT-ZCS based on soft-switching inverters offers some merits such as: tracking the input reference signal dynamically, bearing load shock and short circuit, multiplying inverter N+1 redundancy parallel, coordinating power balance for easy control, and soft-switching commutation for high efficiency and large capacity. These advantages are distinctive from conventional inverter topologies and are especially demanded in AC drives: new energy generation and grid, distributed generation systems, switching power amplifier, active power filter, and reactive power compensation and so on. Prototype is manufactured and experiment results show the feasibility and dynamic voltage-tracking characteristics of the topology.

High Power Density, High Frequency, and High Voltage Pulse Transformer

  • Kim, S.C.;Jeong, S.H.;Nam, S.H.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.4
    • /
    • pp.180-184
    • /
    • 2001
  • The high operation frequency mainly reduces transformer volume in the power supply. A high frequency and high voltage pulse transformer is designed, fabricated, and tested. Switching frequency of the transformer is 100 kHz. Input and output voltages of the transformer are 250 V and 4 kV, respectively. Normal operation power of the transformer is 3 kW. Maximum volume of the transformer is 400 $cm^3$. The power density is thus 7.5 W/$cm^3$. The transformer will be installed in a metal box that has nominal operation temperature of 85 degree centigrade. The transformer and other high voltage components in the box will be molded with Silicon RTV(Room Temperature Vulcaniza) that has a very low thermal conductivity. Procedure of design and test results are discussed. Analytical as well as experimental results of varous paramters such as transformer loss, leakage inductance, distributed capacitance are also discussed. In addition, thermal analysis results from ANSYS code for three different operation conditions are discussed.

  • PDF

Analysis of the Virtual Power Plant Model Based on the Use of Emergency Generators in South Korea

  • Chung, Beom Jin;Kim, Chang Seob;Son, Sung-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.38-46
    • /
    • 2016
  • This study analyzes the economic efficiency of the virtual power plant (VPP) model that aims to integrate a number of emergency generators installed at the consumer end and operate them as a single power plant. Several factors such as the demand response benefits from VPP operation and costs incurred for converting emergency generators into VPP are considered to assess the economic efficiency of the proposed VPP model. Scenarios for yearly VPP conversion are prepared based on the installed capacities of the emergency generators distributed in South Korea, while the costs and benefits are calculated from the viewpoints of participants and power companies in accordance with California Test Methods. Furthermore, a sensitivity analysis is conducted on the cost factors among those affecting the economic efficiency of VPP business because these two factors have a great impact on benefits.

Assesment of Renewable Energy materials and equipment (신재생 기기 재료)

  • Lee, Sang-Heon;Koo, Kyoung-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1442-1442
    • /
    • 2011
  • Increase the cost of electricity generation compared to (30 million won / KW) can only be used in standalone or distributed, but in the same area of photovoltaic conversion efficiency is much higher than with a large Stirling engine development has economic value of the infinite. Commercialization 25KW level or above Stirling engine production or introduction is necessary solar power in the various application and effect analysis for further empirical studies or regional energy projects, demonstration of business expansion and conductor, Stirling engines.

  • PDF

Amplitude Distortion Characteristics of Microwave Frequency Multiplier (마이크로파 주파수 체배기의 진폭 왜곡 특성)

  • Choi, Won;Koo, Kyung-Heon
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.294-297
    • /
    • 2003
  • This paper describes the design and the simulation of a frequency doubler for millimeter-wave applications using distributed amplifier technology. The designed frequency multiplier has 10% bandwidth at 58GHz output. This paper investigates nonlinear analysis of pHEMT frequency multipliers utilizing AM-AM and AM-PM distortion characteristics of frequency doubler. The conversion loss is 2.1dB and harmonic suppression is larger than 18.6dBc with 5dBm input power

  • PDF

A Study on Distributed Generation Output Smoothing (분산전원 출력 smoothing에 관한 연구)

  • Ryu, Ki-Hwan;Shin, Hee-Sang;Kang, Byoung-Wook;Chae, Hui-Seok;Lee, Bo-Bae;Choo, Dong-Wook;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.328-329
    • /
    • 2011
  • To promote the introduction of wind power conversion systems, which have an unstable power output, the adoption of energy storage system is being considered to mitigate variations of wind power output. This paper presents the results of analyzed data obtained by the wind power output smoothing tests.

  • PDF

An Assessment on Harmonics Effect in Customer and the Distributed Power System during Grid Connection of Residential Fuel Cell System (가정용 연료전지 시스템의 계통연계 시 수용가 및 배전계통에서의 고조파 영향 평가)

  • Park, Chan-Eom;Jung, Jin-Soo;Han, Woon-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1280-1285
    • /
    • 2011
  • Recently, due to the use of fossil fuels for electric power production, carbon emissions increased excessively. Thereby, in order to replace fossil fuels, many studies about fossil fuels such as solar and fuel cell energy source are progressing. Fuel cell system has high energy conversion efficiency. Also, fuel cell system is environmentally friendly system because the carbon emission is almost not occur. Therefore, the fuel cell system is considered as the core technology of in the fields of the future energy and environmental. Fuel cell system has an effect on distribution power system because another power source of other than large power plants. So, fuel cell system can be degradation reason of power quality in the power system. In this paper, we constructed the system for an assessment on harmonics effect. The system is composed with power source, harmonics generation and linear load, fuel cell system. we also performed assessment on harmonics effect in customer and the distributed power system during grid connection of residential fuel cell system. An assessment cases are divided into three. A Case 1 is state that residential load and fuel system are connected to grid, Case 2 is state that residential load and harmonics load are connected to grid, and Case 3 is state that all loads are connected to grid. As a output of fuel cell system is increase, analysis results based on assessment system showed that power quality became more aggravation as effect of harmonics.