• 제목/요약/키워드: distributed controlled system

검색결과 188건 처리시간 0.026초

$Al_2O_3-ZrO_2-Spinel$계 복합체의 미세구조 및 물성제어: II. 용액침투법에 의한 $Al_2O_3-ZrO_2-Spinel$ 복합소결체 (Control of Microstructures and Properties of Composites of the $Al_2O_3-ZrO_2-Spinel$ System: II. $Al_2O_3-ZrO_2-Spinel$ Composites Prepared by the Solution Infiltration Method)

  • 현상훈;송원선
    • 한국세라믹학회지
    • /
    • 제30권10호
    • /
    • pp.811-818
    • /
    • 1993
  • Al2O3/ZrO2-Spinel composites were prepared by infiltrating magnesium sulfate solution into the porous preform made from Al2O3-20wt% ZrO2 composite powders derived through an emulsion route. The microstructure and composition of the modified composites could be controlled by manipulating the presingtering temperature of the preform, infiltration time, and so on. It was found that spinel phases were concentrated near the surface than in the interior of the Al2O3/ZrO2-Spinel composites infiltrated for 6hrs, while spinel phases were uniformly distributed in the comosites infiltrated for 2 days. The relative density and fracture toughness of the composite infiltrated for 6 hrs were 98.6% and 7.2MN/m3/2, respectively.

  • PDF

Comparison of Two Different Smoke Extraction Schemes of Transversely Ventilated Tunnel Fire

  • Rie, Dong-Ho;Kim, Hyung-Taek;Yoo, Ji-Oh;Shin, Hyun-Jun;Yoon, Sung-Wook
    • International Journal of Safety
    • /
    • 제4권2호
    • /
    • pp.30-35
    • /
    • 2005
  • In case of tunnel fire, one of the most effective facilities to save lives is the smoke control system. In this study, two different smoke extraction schemes of transversely ventilated tunnel were compared. One is the smoke extraction using the fixed exhaust ports on the false ceiling to achieve the uniform and distributed smoke extraction (uniform exhaust). The other is that using the remote controlled smoke extraction where only vents close to the fire is opened whereas the others are closed to enhance the limitation of the smoke spread (localized exhaust). A number of numerical simulations were performed to find out the optimal smoke extraction rate at each smoke extraction scheme to allow the tunnel users to escape to the safe area without endangering their lives by smoke.

직류 마이크로그리드에서 펄스형 부하 보상용 슈퍼커패시터 무순단 제어법 (A Seamless Control Method for Supercapacitor to Compensate Pulsed Load in DC Microgrid)

  • 담두이헝;이홍희
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.265-272
    • /
    • 2018
  • This paper proposes a new control method for the supercapacitor (SC) to compensate the pulsed load and to enhance the power quality of the DC microgrid. By coordinating the operating frequency, the SC is controlled to handle the surge current, while the low-frequency current component is dealt with by the remaining sources in the system. The operation mode of the SC unit is automatically changed based on the state of charge and DC bus voltage level. Meanwhile, the mismatch in the power demand is covered by the SC unit by regulating the DC bus voltage level. The effectiveness of the proposed method is verified experimentally by the prototype with two distributed generators and one SC unit.

Transient stability improvement using quasi-multi pulse BTB-STATCOM

  • Vural, Ahmel M.;Bayindi, Kamil C.
    • Advances in Energy Research
    • /
    • 제2권1호
    • /
    • pp.47-59
    • /
    • 2014
  • Back-to-back STATCOM configuration is an extension of STATCOM in which the reactive power at two-sides and the real power flow through the DC link can be controlled concurrently and independently. This flexible operation brings many advantages to the micro-grids, distributed generation based systems, and deregulated power systems. In this paper, the dynamic control characteristics of the back-to-back STATCOM is investigated by simulating the detailed converter-level model of the converters in PSCAD. Various case studies in a single-machine test system are studied to present that the real power control feature of the BtB-STATCOM, even with a simple controller design, can enhance the transient stability of the machine under different fault scenarios.

ULTC 와 SVR 이 설치된 배전계통에서 LDC Parameters 을 고려한 최대 DG 용량 산정 (The Installable Maximum DG Capacity Considering LDC Parameters of ULTC and SVR in Distribution Systems)

  • 김미영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.27-28
    • /
    • 2008
  • For stable and sustainable energy supply, distributed generator (DG) has become an essential and indispensable element from environmental and energy security perspectives. However, installation of DG in distribution systems may cause negative affects on feeders because power outputs of DG could be changed irregularly. One of major negative affects is variation in voltage profile. In general, voltage regulation devices such as under load tap changer (ULTC) at distribution substation and step voltage regulator (SVR) along feeder in distribution system are used to maintain customers' receiving voltage within a predetermined range. These regulators are controlled by line drop compensation (LDC) method which calls for two parameters; the equivalent impedance and the load center voltage. Therefore, consideration of DG outputs in the LDC parameter design procedure may give large impact on the installable DG capacity. This paper proposes a method that estimates maximum Installable DG capacity considering LDC parameters of ULTC and SVR. The proposed algorithm is tested with model network.

  • PDF

Feasibility Study of Distributed Auxiliary Resonant Commutation Snubber Linked Three Phase Voltage Source ZVS Inverter with Digital Servo Control Implementation

  • Hiraki, E.;Hattori, H.;Nakaoka, M.;Horiuchi, T.;Sugawara, Y.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.341-345
    • /
    • 1998
  • This paper presents performance and loss analysis of Auxiliary Resonant Commutation Snubber-linked (ARCS) three phase voltage source soft switching inverter which is operated under a condition of Zero Voltage Switching (ZVS). The system performances of this ARCS soft switching inverter which is controlled on optimal type I digital servo scheme are illustrated and evaluated on the basis of experimental results.

  • PDF

직류배전의 전력품질 향상 대책 (Improvement measures for power quality of DC distribution)

  • 한석우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.536-537
    • /
    • 2010
  • If DC voltage adjustment can be controlled very easily, it is much more effective rather than AC in transmission efficiency. The main reason why DC is more effective than AC, DC has the same role as the 70[%] of AC whenever the same power send. In addition, AC streams the surface of electrical wire, but DC streams overall of electrical wire. Digital load, which is operated by DC, has increased in modern times. The step of convert of AC-DC has to be reduced. When we turn the dispersed AC-DC converters into the concentrated AC-DC converter, it can improve the effective of the whole system. Further more, if digital society develops more than now and the time of electric vehicle comes, the need of DC will increase much more than these days. This paper suggests that DC output of distributed power source and high efficient 3 phase PWM converter can control the adjustment of output voltage, harmonic restraint, power factor improvement and dump power.

  • PDF

객체지향 방법론을 이용한 제품정보관리(PDM) 시스템에서의 워크플로우 설계 (Workflow Design on Product Data Management System Using Object-Oriented Modeling Technique)

  • 최종윤;최경희;안병하
    • 한국전자거래학회지
    • /
    • 제4권1호
    • /
    • pp.145-157
    • /
    • 1999
  • The challenge is to maximize the time-to-market benefits of concurrent engineering while maintaining control of data and distributing it automatically to the people who need it when they need it. The way PDM systems cope with this challenge is that master data is held only once in a secure vault where its integrity can be assured and all changes to it monitored, controlled and recorded. The structure of PDM is various from vendor, but they have common module. That is PDM and it is most important. The goal is to design the workflow in PDM using object-oriented modeling method. The past methods have concentrated on the flow between workflow engine and agent, but this paper will focus on task. We will model task as individual object. This paper uses OMT(Object Modeling Technique) by James Rumbaugh for base modeling tool and uses DCOM(Distributed Component Object Model) for base ORB(Object Request Broker). Research object is to design the static object model, to design state change by dynamic model and to design data transition by functional model.

  • PDF

보급형 자동옥습기 개발을 위한 설계 및 제작 (Design and Fabrication for the Development of the Distributed Auto Edging Machine)

  • 이영일;김정희;박지현
    • 한국안광학회지
    • /
    • 제16권2호
    • /
    • pp.107-115
    • /
    • 2011
  • 목적: 안경렌즈 조제가공을 위한 보급형 전자동 옥습기 개발을 위해 설계하고 제작하고자 한다. 방법: 보급형 전자동 옥습기의 주요 설계도를 캐드로 그려서 제작에 필요한 정보를 얻었다. 이 데이터를 기본으로 보급형 자동옥습기 개발을 위해 시제품을 제작 하였다. 결과: 무패턴 모드는 외부 자동 취형기에서 안경테의 렌즈삽입부 정보를 RS232C 전송방식으로 형판 없이도 작동할 수 있었고, 패턴 모드는 형판을 이용해서 개발품의 좌측에 장착하여 작동할 수 있었다. 보급형 자동옥습기는 헤드부, 오토암부, 형판고정부 그리고 연삭부와 같은 주요 요소들로 구성되었다. 헤드부는 좌우모터와 상하모터의 작동을 이용하여 안경렌즈의 연삭을 제어하였다. 연삭부는 유리 재질, 플라스틱 재질, V-홈 그리고 광택을 낼 수 있는 연삭휠로 구성하였다. 슬라이드는 고정된 형판의 하부에 구비되었고, 고정 샤프트에 의해 회전되는 형판이 슬라이드부에 의해 지지할 수 있었다. 형판고정부는 안경사의 수동적인 조작에 의해 헤드파트를 승강 및 좌우 이동시킬 수 있게 하였다. 연삭휠의 분당 회전수를 3,600 rpm으로 최적화 하였다. 결론: 패턴리스와 패턴 렌즈 가공이 가능한 보급형 자동옥습기를 설계 및 제작하여 시제품 제작에 성공하였다. 최소의 비용으로 효율적이고 간편하게 조제가공이 가능하여 안경사들에게 큰 도움이 될 수 있을 것으로 예상된다.

해창만의 수질환경변동 및 담수방류의 영향평가 (Effect of the Freshwater Discharge on Water Quality Variation and in Haechang Bay, Korea)

  • 이대인;조현서;이문옥
    • 환경영향평가
    • /
    • 제12권5호
    • /
    • pp.341-348
    • /
    • 2003
  • Seasonal characteristics of water quality and effect of the freshwater discharge during open the tide embankment in Haechang Bay were evaluated. In the freshwater, where interior of the tide embankment, COD and Chl-a exceeded about 4mg/L and $10mg/m^3$, respectively, independent of season, while in the seawater they showed high values in April and July in contrast to the other period due to input of freshwater and increase of phytoplankton, respectively. The content of seawater inorganic nitrogen maintained a relatively high level at inner part of the bay, whereas high values of inorganic phosphorus content was distributed at all over the bay. The limiting factor for algal growth was nitrogen with respect to the N/P ratio. The compass of influence by the freshwater discharge in April was quite different with water pollutants. As a result of the salinity variation with time, the freshwater extended strongly to offshore from the surface layer without mixing with depth when open the tide embankment, and reached within about one hour at a station which is 3.5km from the tide embankment. To effective water quality management of Haechang Bay, discharge rate and pollutant loads should be controlled.