• Title/Summary/Keyword: distributed controlled system

Search Result 188, Processing Time 0.028 seconds

Variation of Transient-response in Open-ended Microstrip Lines with Optically-controlled Microwave Pulses

  • Wang, Xue;Kim, Kwan-Woong;Kim, Yong-K.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.2
    • /
    • pp.53-57
    • /
    • 2009
  • In this paper we develop a method to observe faults in semiconductor devices and transmission lines by calculating the variation of the reflection function in a dielectric microstrip line that has an open-ended termination containing an optically induced plasma region. It is analyzed with the assumption that the plasma is distributed homogeneously in laser illumination. With the non linear material of degradation, the concentration of the carrier in the part of the material has changed. Since the input wave has produced the phenomenon of reflection, the input signal to the open-ended microstrip lines can be observed on reflection to identify the location of the fault. The characteristic impedances resulting from the presence of plasma are evaluated by the transmission line model. The variation of the reflection wave in the microwave system has been calculated by using an equivalent circuit model. The transient response has been also evaluated theoretically for changing the phase of the variation in the reflection. The variation of characteristic response in differentially localized has been also evaluated analytically.

Preparation of Nanoparticles in Drug Delivery System Using Guar Derivatives and Dialysis Method

  • Na, Kun;Kim, Yu-Eun;Lee, Ki-Young
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.1
    • /
    • pp.50-55
    • /
    • 1999
  • To develop a new form of controlled release dosage for administering for indomethacin (IND), two formulations of IND-loaded nanoparticles were designed based on polysaccharide (guar) derivatives. Nanoparticles prepared by the dialysis method were characterized with respect to morphology, size distribution, drug content, and in vitro drug release. Morphological studies by scanning electron microscopy (SEM) indicated that guar acetate (GA) nanoparticles were spherical in shape and had a smooth surface. The particle size distributions of formulation I (40mg of GA) and formulation II (80mg of GA) were shown to be $250.78\pm185.13nm$ and $718\pm145.90nm$ in distilled water ($20$^{\circ}C$), respectively. The drug loading efficiencies of nanoparticles were approximately 26% and 31% for formulations I and II, respectively. The differential scanning calorimetry (DSC) results indicated that the IND was perfectly distributed within GA nanoparticles. We also found, from the X-ray diffractometry analysis, that a decrease in the degree of crystallinity of the drug occurred in the nanoparticles. No changes between the original IND and the released IND from GA nanoparticles were detected by FT-IR. Using guar acetate, it is possible to design nanoparticles which allow the controlled release of IND over an extended period of time.

  • PDF

Study on the Relationship and Validity of the Management Evaluation Factors in Public Firms With a Focus on the Port Authorities

  • Lee, Sung-Yhun;Ahn, Ki-Myung
    • Journal of Navigation and Port Research
    • /
    • v.43 no.6
    • /
    • pp.450-461
    • /
    • 2019
  • According to the results of the management evaluation of the nation's public firms over the past seven years, the rating of the port corporation is generally insufficient. According to the results of the seven-year study 2011-2017, the average debt ratio of the port corporation was 34.5%, two to three times lower than that of the general public company, the operating profit ratio of sales was three times higher, and the value added per person was 1.6-1.9 times better. However, the aggregate score and grade were generally low, with 4.1% of the total number of employees of the general public corporation, 10% of the average total assets, and 1% of the average sales volume. The distributed analysis results and panel return analysis results show that the size significantly impacts the overall score and grade. Additionally, major business standards such as port volume, not controlled by the port corporation, appear to have a decisive influence on the low grade of the port corporation. Thus, it appears that improvement and supplementation of key business indicators of port construction are urgently needed in the management evaluation system, which can be properly controlled.

A study on development of Power Cable countermeasuring EFT IEC801-4 (EFT IEC801-4 대책용 전원케이블의 개발에 관한 연구)

  • 김형근;배대환;민경찬;김동일
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.2
    • /
    • pp.107-113
    • /
    • 1995
  • Since the most of the mal-functions in the industrial equipments controlled by processors have been occured by the Electrical Fast Transient(EFT), the International Electrotechnical Commision(IEC) prepare the dummy signal to test the immunity level of the equipments controlled by processors and recommend it for the measuring. In this paper, the defined dummy EFT signal by IEC are analyzed by the spectrum analyzer in the frequency domain and studied the developed countermeasuring parts. The new developed parts are consist of the feedthrough capacitors ( $C_y$ type ) in the input and materials with high permeaility which was wound or inserted in the second layer of the Power Cable in order to increase Common Mode inductance. And it is compared inserted Permalloy to material with high permeability increasing Common Mode inductance. We could gotten a excellent insertion loss on the wide band against EFT signal. Especially, we confirm that countermeasuring Power Cable have been an excellent dynamic characteristics in computer system above the 3.6Kv. This new parts could be effectively used for industrial, MIL, and medical equipments to reduce a mal-functions on the site. Furthermore, these parts also have a good characteristics for EMI countermeasuring over the 60MHz up to several GHz band, they are also expected to be used for all kind of EMS test with IEC801-2, 3, 5 and 6 on the power distributed line.

  • PDF

Implementation of Embedded Micro Web Server for Web based Remote Hardware Control and Monitor (웹 기반 하드웨어 원격감시 및 제어를 위한 초소형 내장형 웹 서버 시스템의 구현)

  • Han, Kyong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.104-110
    • /
    • 2006
  • In this paper, we proposed the micro web-server implementation on Strong ARM processor with embedded Linux. The parallel port connecting parallel I/O is controlled via HTTP protocol and web browser program HTTP protocol with Linux, the micro web server program and port control program are installed on-board memory using CGI to be accessed by web browser. The processor parallel input port is monitored and parallel output port is controlled from remote hosts via HTTP protocol. The result of the proposed embedded micro-web server can be used in remote automation systems, distributed control via internet using web browser.

Operating Method of BESS for Providing AGC Frequency Control Service Considering Its Availability Maximization (배터리 가용성 극대화를 고려한 BESS의 AGC 주파수제어 추종운영방안)

  • Choi, Woo Yeong;Yu, Ga Ram;Kook, Kyung Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1161-1168
    • /
    • 2016
  • Battery energy storage system(BESS) attract the attention of the power system operators with its fast response to a disturbance in spite of its limited energy capacity. This paper proposes the operating method of BESS for following the Automatic Generation Control(AGC) frequency control which is centrally distributed by a system operator. As BESS needs to just meet the control requirement from the system operator, it should be able to properly manage the state of charge(SOC) of BESS to be available to control signal. For doing these, the proposed method distributes the control requirement to available batteries in proportion to its SOC. In addition, unavailable batteries are controlled to recover the SOC to an appropriate range, and the recovering power is supplied by available batteries meeting the control requirement. Moreover, the proposed method manages the efficiency of power conversion system (PCS) by limiting the number of PCS to be assigned for the low control requirement. Finally, the case studies are carried out to verify the effectiveness of proposed strategy.

A study for IT Based Optimal Voltage Control Method of Distribution Systems with Distributed Generation (IT기반 분산전원 연계 배전계통의 최적전압조정에 관한 연구)

  • Kim, Jung-Nyun;Baek, Young-Sik;Seo, Gyu-Seak
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.4
    • /
    • pp.139-143
    • /
    • 2006
  • Recently, standard of living improved and Information-Communication industry developed rapidly. Thereby, interest about electric power quality is rising worldwide. So, research and Development to enhance electric power quality in various viewpoint until most suitable supply system from each kind device to improve electric power quality. And specially, interest about voltage quality is rising by diffusion increase of information communication appliance and minuteness control appliance etc. Also Power consumption is increasing, but expansion of large size generator by environmental and site security problem is difficult. So, introduction of distribution generation is investigated actively by electric-power industry reorganization. Voltage management of power system had been controlled by ULTC (Under Load Tap Changer) in substation and pole transformer on the high voltage distribution line. But, voltage control device on substation and distribution line is applied each other separatively. Therefore, efficiency of line voltage control equipment is dropping. Also, research about introduction upper limit of distribution generation is consisting continuously. This paper presents cooperation use way between voltage control device and introduction upper limit of distribution generation for most suitable voltage control in distribution power system.

Experiment of Distributed Optical Fiber Sensor Using Spatially-Selective Brillouin Scattering (공간 선택적 브릴루앙 산란을 이용한 분포형 광섬유 센서의 실험)

  • Seo, Min-Sung;Yun, Seung-Chul;Hyun, Jin-Young;Park, Hee-Gap
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.3
    • /
    • pp.223-230
    • /
    • 2006
  • We demonstrate a distributed fiber sensor system based on spatially-selective Brillouin scattering, using a single laser diode as a light source whose optical frequency is directly modulated by the injection current. The pump and the counter-propagating probe lights, which are sinusoidally frequency-modulated, are superposed in the fiber so that stimulated Brillouin scattering takes places only at a specific location along the fiber. Brillouin gain peak position is controlled by varying the modulation frequency. Distributions of Brillouin shift frequency are measured for the case of concatenated optical fibers of two different kinds and also for the case of temperature distribution. The temperature coefficient of the Brillouin shift frequency is measured to be $1.33MHz/^{\circ}C$.

Electroluminescence(EL)와 그의 응용

  • 이성오
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.4
    • /
    • pp.15-20
    • /
    • 1991
  • The paper considers a distributed adaptive control technique for industrial robots which contribute to the factory automation. The control object is to tracking for a desired trajectories under various load conditions., rapidly against load variation these control techniques divided whole system into subsystems which is controlled with the nominal and adaptation controllers, and also the asymptotic stability of these substem was proved. Simulation results shown that the proposed techniques was feasible in spite of nonlinear dynamics of robot manipulator and payload variations.

  • PDF

A Study On the Design Of Fuzzy Controller for the Steam Temperature Process in the Coal Fired Power Plant

  • Shin, Sang-Doo;Kim, Yi-Gon;Lee, Bong-Kuk
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.350-353
    • /
    • 2003
  • In this paper, we proposed the method to design fuzzy controller using the experience of the operating expert and experimental numeric data for the robust control about the noise and disturbance instead of the traditional PID controller for the main steam temperature control of the thermal power plant. The temperature of main steam temperature process has to be controlled uniformly for the stable electric power output. The process has the problem of the hunting for the cases of various disturbances. In that case, the manual action of the operator happened to be introduced in some cases. We adopted the TSK (Takagi-Sugeno-Kang) model as the fuzzy controller and designed the fuzzy rules using the informations extracted directly from the real plant and various operating condition to solve the above problems and to apply practically. We implemented the real fuzzy controller as the Function Block module in the DCS(Distributed Control System) and evaluated the feasibility through the experiment81 results of the simulation.

  • PDF