Performance Evaluations of Four MAF-Based PLL Algorithms for Grid-Synchronization of Three-Phase Grid-Connected PWM Inverters and DGs

  • Han, Yang;Luo, Mingyu;Chen, Changqing;Jiang, Aiting;Zhao, Xin;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1904-1917
    • /
    • 2016
  • The moving average filter (MAF) is widely utilized to improve the disturbance rejection capability of phase-locked loops (PLLs). This is of vital significance for the grid-integration and stable operation of power electronic converters to electric power systems. However, the open-loop bandwidth is drastically reduced after incorporating a MAF into the PLL structure, which makes the dynamic response sluggish. To overcome this shortcoming, some new techniques have recently been proposed to improve the transient response of MAF-based PLLs. In this paper, a comprehensive performance comparison of advanced MAF-based PLL algorithms is presented. This comparison includes HPLL, MPLC-PLL, QT1-PLL, and DMAF-PLL. Various disturbances, such as grid voltage sag, voltage flicker, harmonics distortion, phase-angle and frequency jumps, DC offsets and noise, are considered to experimentally test the dynamic performances of these PLL algorithms. Finally, an improved positive sequence extraction method for a HPLL under the frequency jumps scenario is presented to compensate for the steady-state error caused by non-frequency adaptive DSC, and a satisfactory performance has been achieved.

6th Harmonic Control Method for Reduction of Grid Current Harmonic Distortion in a Grid-Connected Inverter (계통연계형 인버터의 계통 전류 고조파 저감을 위한 6차 고조파 제어 기법)

  • Sin, Jiook;Bak, Yeongsu;Lee, Kyo-Beum
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.145-146
    • /
    • 2016
  • 본 논문에서는 계통연계형 인버터의 계통 전류 고조파 저감기법을 제안한다. 일반적으로 인버터의 계통연계를 수행할 때, 계통 측 전류는 주로 정지 좌표계 상의 5차 및 7차 고조파 성분을 포함한다. 계통 측 전류의 5차 및 7차 고조파 성분은 동기 좌표계 상에서 6차 고조파 성분으로 나타난다. 본 논문에서는 동기 좌표계 상의 6차 고조파 성분 제어를 적용하여 계통전류의 고조파를 저감하는 기법을 제안한다. 제안하는 기법의 타당성은 시뮬레이션을 통해 검증한다.

  • PDF

Analysis of Compressible Flow Fields in a High Voltage Gas Circuit Breaker (초고압 가스차단기 내부의 압축성 유동장 해석)

  • Lee, J.C.;Oh, I.S.;Kim, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.305-310
    • /
    • 2001
  • This paper presents the computational method for analyzing the compressible flow fields in a high voltage gas circuit breaker. There are many difficult problems in analyzing the gas flow in GCB due to complex geometry, moving boundary, shock wave and so on. In particular, the distortion problem of the grid due to the movement of moving parts can be worked out by the fixed grid technique. Numerical simulations are based on a fully implicit finite volume method of the compressible Reynolds-averaged Navier-Stokes equations to obtain the pressure, density, and velocity through the entire interruption process. The presented method is applied to the real circuit breaker model and the pressure in front of the piston is good agreement with the experimental one.

  • PDF

Modeling of shunt active power filter using PSCAD/EMTDC

  • Vu, Trung-Kien;Seong, Se-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.293-295
    • /
    • 2009
  • In this paper, a shunt active power filter (SAPF) has been used to eliminate the harmonic distortion and to improve the power quality of three-phase grid-connected power conditioning system (PCS). The adopted control strategy in active power filter system is based on the instantaneous reactive power theory (P-Q theory). Based on the theoretical analysis, the overall system of three-phase grid-connected with non-linear load PCS has been built and modeled using PSCAD$^{(R)}$/EMTDC$^{TM}$. The simulation results are shown to verify the high effective performance of the implemented SAPF in power system and to verify the reasonableness of the system structure.

  • PDF

An Applicability of Teager Energy Operator and Energy Separation Algorithm for Waveform Distortion Analysis : Harmonics, Inter-harmonics and Frequency Variation

  • Cho, Soo-Hwan;Hur, Jin;Chung, Il-Yop
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1210-1216
    • /
    • 2014
  • This paper deals with an application of Teager Energy Operator (TEO) and Energy Separation Algorithm(ESA) to detect and determine various voltage waveform distortions like harmonics, inter-harmonics and frequency variation. Because the TEO and DESA algorithm was initially proposed for speech or communication analysis, its applications are limited to some types of waveform in the power quality analysis area. For example, an undistorted voltage signal is similar with a pure sinusoid. A voltage fluctuation is very similar with an amplitude-modulated signal, from the viewpoint of signal theory. And a continuous frequency variation is similar with a frequency-modulated signal, which is also known as a chirp signal. This paper is written to show that the TEO and DESA algorithm can be used for detecting occurrences of the representative waveform distortions and determining their instantaneous information of amplitude and frequency.

A Hysteresis Current Controller for PV-Wind Hybrid Source Fed STATCOM System Using Cascaded Multilevel Inverters

  • Palanisamy, R.;Vijayakumar, K.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.270-279
    • /
    • 2018
  • This paper elucidates a hysteresis current controller for enhancing the performance of static synchronous compensator (STATCOM) using cascaded H-bridge multilevel inverter. Due to the rising power demand and growing conventional generation costs a new alternative in renewable energy source is gaining popularity and recognition. A five level single phase cascaded multilevel inverter with two separated dc sources, which is energized by photovoltaic - wind hybrid energy source. The voltages across the each dc source is balanced and standardized by the proposed hysteresis current controller. The performance of STATCOM is analyzed by connecting with grid connected system, under the steady state & dynamic state. To reduce the Total Harmonic Distortion (THD) and to improve the output voltage, closed loop hysteresis current control is achieved using PLL and PI controller. The performance of the proposed system is scrutinized through various simulation results using matlab/simulink and hardware results are also verified with simulation results.

Control of Three-Phase Three-Switch Buck-Type Rectifier in EV Rapid Charging Systems

  • Chae, Beomseok;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.189-190
    • /
    • 2015
  • This paper investigates an economic and highly efficient power converter topology and its modulation scheme for 60kW rapid EV charger system. The target system consists of three-phase three-switch buck-type rectifier topology. A new Carrier Based PWM scheme along with its simple implementation using logic gates is introduced in this paper. This PWM scheme replaces the diode rectifier equivalent switching state with an active switching state producing the effectively same current flowing path. As a result, the distortion of input current during the polarity reversal of capacitor line voltage can be mitigated. The proposed modulation technique is confirmed through simulation verification. The proposed modulation technique and its implementation scheme can expand the operation range of the three-phase three-switch buck-type rectifier having ac input and capacitor ripple current of high quality.

  • PDF

Islanding Detection for Grid-connected PV Inverter under Parallel Operation (계통연계형 태양광 인버터 병렬운전 상황에서의 단독운전 검출)

  • Jo, Yeong-Min;Kim, Dong-Gyun;Song, Seung-Ho;Choy, Ick;Lee, Young-Kwoun;Cho, Sang-Yoon;Choi, Ju-Yeop
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.283-289
    • /
    • 2016
  • Islanding protection of a grid-connected photovoltaic (PV) inverter is a key function for standards compliance. Unintentional islanding results in safety hazards, reliability, and many other issues. Therefore, many anti-islanding schemes have been examined. However, existing anti-islanding schemes have poor power quality and non-detection zone issues. Moreover, most schemes have problems that deteriorate the performance of islanding detection under parallel operation. Therefore, this paper proposes a novel anti-islanding scheme that has negligible power quality degradation and has no non-detection zone and islanding detection under a parallel operation. Both simulation and experimental results validate the proposed scheme.

A Novel Active Anti-islanding Method for Grid-connected Photovoltaic Inverter

  • Jung, Young-Seok;Choi, Jae-Ho;Yu, Gwon-Jong
    • Journal of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.64-71
    • /
    • 2007
  • This paper proposes a novel active frequency drift (AFD) method to improve the islanding detection performance with minimum current harmonics. To detect the islanding phenomenon of grid-connected photovoltaic (PV) inverters concerning the safety hazards and possible damage to other electric equipment, anti-islanding methods have been described. The AFD method that uses chopping fraction (cf) enables the islanding detection to drift up (or down) the frequency of the voltage during the islanding situation. However, the performance of the conventional AFD method is inefficient and causes difficulty in designing the appropriate cf value to meet the limit of harmonics. In this paper, the periodic chopping fraction based on a novel AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 929-2000 with power quality and islanding detection time. To verify the validation of the proposed method, the islanding test results are presented. It is confirmed that the proposed method has not only less harmonic distortion but also better performance of islanding detection compared with the conventional AFD method.

Analysis of a Synchronizing PLL System for Single-phase Grid-tie Inverters (단상 그리드연결형 인버터의 동기화를 위한 PLL 시스템 해석)

  • Tran, Quang-Vinh;Chun, Tae-Won;Lee, Hong-Hee;Kim, Heung-Geun;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.447-452
    • /
    • 2008
  • In the paper, the product-type PLL system, which is so suitable for synchronizing a single phase grid voltage is designed. The PLL system is modelled with the small signal analysis. Both the cut-off frequency of low pass filter and the optimal gain are derived by considering the transient response for synchronization as well as a distortion of synchronization signal. Through the simulation studies and experimental results, the transient response and ripple component of synchronization signal are investigated with a variation of both the cut-off frequency and gain in order to verify the performance of design.