• Title/Summary/Keyword: distance-to-agreement

Search Result 342, Processing Time 0.023 seconds

Wind Turbine Power Performance Testing using Nacelle Transfer Function (나셀 변환 함수를 이용한 풍력터빈 출력성능평가)

  • Kim, Hyeon-Wu;Ko, Kyung-Nam;Huh, Jong-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.51-58
    • /
    • 2013
  • A study on power performance testing of a wind turbine which has no met-mast at a distance of 2~4 rotor diameter was carried out using the Nacelle Transfer Function, NTF, according to IEC 61400-12-2. The wind data for this study was measured at HanKyoung wind farm of Jeju Island. The NTF was modeled using the correlation between wind speeds from the met-mast and from the wind turbine nacelle within 2~4 rotor diameter from the met-mast. The NTF was verified by the comparison of estimated Annual Energy Productions, AEPs, and binned power curves. The Nacelle Power Curve, NPC, was derived from the nacelle wind speed data corrected by NTF. The NPC of wind turbine under test and the power curve offered by the turbine manufacturer were compared to check whether the wind turbine is properly generating electricity. Overall the NPC was in good agreement with the manufacturer's power curve. The result showed power performance testing for a wind turbine which has no met-mast at a distance of 2~4 rotor diameter was successfully carried out in compliance with IEC 61400-12-2.

Cephalometric landmark variability among orthodontists and dentomaxillofacial radiologists: a comparative study

  • Durao, Ana Paula Reis;Morosolli, Aline;Pittayapat, Pisha;Bolstad, Napat;Ferreira, Afonso P.;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.213-220
    • /
    • 2015
  • Purpose: The aim this study was to compare the accuracy of orthodontists and dentomaxillofacial radiologists in identifying 17 commonly used cephalometric landmarks, and to determine the extent of variability associated with each of those landmarks. Materials and Methods: Twenty digital lateral cephalometric radiographs were evaluated by two groups of dental specialists, and 17 cephalometric landmarks were identified. The x and y coordinates of each landmark were recorded. The mean value for each landmark was considered the best estimate and used as the standard. Variation in measurements of the distance between landmarks and measurements of the angles associated with certain landmarks was also assessed by a subset of two observers, and intraobserver and interobserver agreement were evaluated. Results: Intraclass correlation coefficients were excellent for intraobserver agreement, but only good for interobserver agreement. The least reliable landmark for orthodontists was the gnathion (Gn) point (standard deviation [SD], 5.92 mm), while the orbitale (Or) was the least reliable landmark (SD, 4.41 mm) for dentomaxillofacial radiologists. Furthermore, the condylion (Co)-Gn plane was the least consistent (SD, 4.43 mm). Conclusion: We established that some landmarks were not as reproducible as others, both horizontally and vertically. The most consistently identified landmark in both groups was the lower incisor border, while the least reliable points were Co, Gn, Or, and the anterior nasal spine. Overall, a lower level of reproducibility in the identification of cephalometric landmarks was observed among orthodontists.

Application of a Statistical Interpolation Method to Correct Extreme Values in High-Resolution Gridded Climate Variables (고해상도 격자 기후자료 내 이상 기후변수 수정을 위한 통계적 보간법 적용)

  • Jeong, Yeo min;Eum, Hyung-Il
    • Journal of Climate Change Research
    • /
    • v.6 no.4
    • /
    • pp.331-344
    • /
    • 2015
  • A long-term gridded historical data at 3 km spatial resolution has been generated for practical regional applications such as hydrologic modelling. However, overly high or low values have been found at some grid points where complex topography or sparse observational network exist. In this study, the Inverse Distance Weighting (IDW) method was applied to properly smooth the overly predicted values of Improved GIS-based Regression Model (IGISRM), called the IDW-IGISRM grid data, at the same resolution for daily precipitation, maximum temperature and minimum temperature from 2001 to 2010 over South Korea. We tested various effective distances in the IDW method to detect an optimal distance that provides the highest performance. IDW-IGISRM was compared with IGISRM to evaluate the effectiveness of IDW-IGISRM with regard to spatial patterns, and quantitative performance metrics over 243 AWS observational points and four selected stations showing the largest biases. Regarding the spatial pattern, IDW-IGISRM reduced irrational overly predicted values, i. e. producing smoother spatial maps that IGISRM for all variables. In addition, all quantitative performance metrics were improved by IDW-IGISRM; correlation coefficient (CC), Index Of Agreement (IOA) increase up to 11.2% and 2.0%, respectively. Mean Absolute Error (MAE) and Root Mean Square Error (RMSE) were also reduced up to 5.4% and 15.2% respectively. At the selected four stations, this study demonstrated that the improvement was more considerable. These results indicate that IDW-IGISRM can improve the predictive performance of IGISRM, consequently providing more reliable high-resolution gridded data for assessment, adaptation, and vulnerability studies of climate change impacts.

Development and Evaluation of an Self-Operated Face Capturing System (자가 안면영상 촬영장치 개발 및 검증)

  • Jeon, Young-Ju;Do, Jun-Hyeong;Kim, Jang-Wong;Kim, Sang-Gil;Lee, Hae-Jung;Lee, Yu-Jung;Kim, Keun-Ho;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.17 no.2
    • /
    • pp.115-120
    • /
    • 2011
  • Objectives : The purpose of this study is to develop an apparatus which can take a facial image by self-operated capturing technique. The user can obtain one's facial image immediately after adjusting facial tilt and focusing distance. The system has been designed for classifying Sasang typology based on facial image. Methods : The system is composed of a Webcam, one-way glass mirror and mini LCD. The Webcam takes a facial image which is displayed on the mini LCD. Then the user can see and adjust to the right position in the real time through the image mirror-reflected from the mini LCD. The optical sensor is used to estimate the proper focusing distance. To verify the performance of the system, 11 characteristic points on the facial image are used and compared with high performance DSLR camera(D700) by applying the coefficient of variance and Bland-Altman Plot. Results : The developed system and D700 show enough agreement with the small coefficient of variance to analyse constitutional types with a facial im mage. However, the result of Bland-Altman plot shows that the width parameters have distortions owing to short focusing distance. Conclusions : The system is expected to be utilized on u-healthcare services for home environment after improving the distortion in the width parameters.

Sensitivity Analysis of Ordinary Kriging Interpolation According to Different Variogram Models (베리오그램 모델 변화에 따른 정규 크리깅 보간법의 민감도분석)

  • Woo, Kwang-Sung;Park, Jin-Hwan;Lee, Hui-Jeong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.3
    • /
    • pp.295-304
    • /
    • 2008
  • This paper comprises two specific objectives. The first is to examine the applicability of Ordinary Kriging interpolation(OK) to finite element method that is based on variogram modeling in conjunction with different allowable limits of separation distance. The second is to investigate the accuracy according to theoretical variograms such as polynomial, Gauss, and spherical models. For this purpose, the weighted least square method is applied to obtain the estimated new stress field from the stress data at the Gauss points. The weight factor is determined by experimental and theoretical variograms for interpolation of stress data apart from the conventional interpolation methods that use an equal weight factor. The validity of the proposed approach has been tested by analyzing two numerical examples. It is noted that the numerical results by Gauss model using 25% allowable limit of separation distance show an excellent agreement with theoretical solutions in literature.

Duration Magnitude and Local-Duration Magnitude Relations for Earth-quakes of 1979-1998 Recorded at KMA Network (한반도 지진의 지속규모식에 관한 연구)

  • 박삼근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.421-435
    • /
    • 1998
  • An empirical formula for estimating duration magnitude(MD)is determined by analyzing 619 epicentral distance-duration data set, obtained from earthquakes of 1989-1998 recorded at the KMA network. Based on two assumptions: 1) observed signal duration decreases with increasing epicentral distance, and 2) seismographs of KMA are set at low-gain and therefore inclusion of sensitivity correction term in the equation is not necessary, scaling predicted duration at epicenter to Tsuboi's local magnitude yielded the duration magnitude equation: MD =2.0292$\times$log$\tau$+0.00123Δ-1.4017 for 1/0$\leq$ML$\leq$5.0, where $\tau$is total signal duration(sec)and Δis epicentral distance(km). Event by event comparison of ML values against MD estimates for t152 events shows that for events having a same ML the difference in MD estimates reaches as high as 1.1 magnitude units. So, to test the usefulness of the duration magnitude equation, we have calculated ML-MD relations by which duration magnitude estimates are converted to local magnitudes ("predicted" ML, say) which are then compared with the directly determined local magnitude values. Except for events with stations where duration is anomalously reestimates(predicted ML) which are in an agreement within a 0.2 magnitude units with the corresponding ML values. Although this study could gain some insights into magnitudes of the past events, we still need to re-examine all the observables in order to obtain more reliable and precise information about magnitude and hypocenter location. So we will pursue a new local-magnitude scaling, as well as refinement of the duration magnitude equation, starting soon with re-reading the amplitudes-arrival time records of (and hence relocating) 250+earthquakes of 1979-present recorded at the KMA network. Thus, with more reliable and precise earthquake parameters determined we would better understand the recent seismicity and related tectonic process within and adjacent region to the Korean peninsula.peninsula.

  • PDF

Safety Management of Steel Pipe Scaffold using UAV (무인항공기(UAV)를 활용한 건설현장 가시설물 안전관리)

  • Jun, Byong-Hee;Kim, Nam-Gyun;Jun, Kyo-Won;Choi, Bong-Jin
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.3
    • /
    • pp.59-67
    • /
    • 2019
  • In this study, the UAV (Unmammed Aerial Vehicle) was applied for the photogrammetry of the construction site and the safety management of steel pipe scaffold. The research site is a temporary facility for building reinforcement on Samcheok Campus of Kangwon National University. The installation condition of the steel pipe scaffold was investigated, and the pillar distance, the beam distance and the wale distance were surveyed. As a result, it was found that the beam distance of the scaffold in the longitudinal direction was in good agreement with the standard, but the pillar distance and the wale distance were found to be less than the standard. Three-dimensional data can be used in drone shooting to enable three-dimensional measurement, so that it is possible to measure facilities hidden or located inside other facilities. Through the drone shooting, the condition of the site can be quickly recorded and the surveying can be carried out without interfering with the work of the field personnel. Although the installation of the temporary structure must be strictly observed to ensure the safety of the workers, it is found that the installation standards are still neglected in the field. In order to prevent this practice, it was thought that the legal system should be supplemented so that it could be checked periodically by using UAV in the field process management.

Comparative Analysis of Heavy Metal Exposure Concentrations and Volatile Organic Compound Metabolites among Residents in the Affected Area According to Residential Distance from a Coal-fired Power Plant (화력발전소 영향권 주민 거주지의 이격 거리별 중금속 및 휘발성유기화합물 대사체 노출 농도 비교 분석)

  • Jee Hyun Rho;Byoung-Gwon Kim;Jung-Yeon Kwon;Hyunji Ju;Na-Young Kim;Hyoun Ju Lim;Seungho Lee;Byeng-Chul Yu;Suejin Kim;Young-Seoub Hong
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.1
    • /
    • pp.25-35
    • /
    • 2024
  • Background: There are concerns about the health effects of various environmental pollution exposures among residents living near coal-fired power plants (CFPP). Objectives: This study attempted to compare the concentrations of heavy metals in blood and urine and those of urinary volatile organic compound (VOC) metabolites according to the residential separation distance. Methods: Participants in the study totaled 334 people who have lived for more than 10 years in areas within 10 km of a CFPP. The separation distance was analyzed in quartiles by dividing it into Q1 (88 people), Q2 (89 people), Q3 (89 people), and Q4 (68 people). We explained the purpose of this study to the participants and collected blood and urine after obtaining signatures on a participation agreement. Results: The study participants were 102 males (30.5%) and 232 females (69.5%), with an average age of 71. The average length of residence and distance were 43.8 years and 4,800 meters. The geometric mean concentrations of Pb, Cd, and Hg in blood and As and Cd in urine were respective 1.35 ㎍/dL, 1.43 ㎍/L, 3.16 ㎍/L. They were 167.88 ㎍/g for creatinine and 1.58 ㎍/g creatinine. The metabolite concentrations of VOCs were 50.67 ㎍/g creatinine in t, t-muconic acid (t, t-MA), 10.73 ㎍/g creatinine in benzyl mercapturic acid, 317.05 ㎍/g creatinine in phenylglyoxylic acid, 123.55 ㎍/g creatinine in methylhippuric acid, and 190.82 ㎍/g creatinine in mandelic acid. The concentration of Pb in the blood and Cd and t, t-MA in the urine of residents within affected area of the CFPP showed statistically significant differences among distance groups. Conclusions: The concentration of urinary VOCs metabolites, especially t, t-MA, differed according to the distance groups of residents within the affected area of CFPP (p<0.05).

Determination of the Magnetic Moment of ${\alpha}-Fe_{2}O_{3}$ of the Parasitic Ferromagnetism by the Proton Relaxation in Water (물의 양성자완화에 의한 기생 강자성 ${\alpha}-Fe_{2}O_{3}$의 자기능률 결정)

  • Yong-Jin Kim;Jung-Gi Kim
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.3
    • /
    • pp.282-284
    • /
    • 1994
  • A theoretical expression for determining the effective magnetic moment of hematite(${\alpha}-Fe_{2}O_{3}$) particle of the parasitic ferromagnetism by the proton relaxation in water is derived. In deriving the expression it is found that the mathematical procedures are exactly the same as those applied for aqueous solutions containing free paramagnetic ions, except that the distance between the proton spin of water molecule and the corresponding electronic spin of the particle must be considered to be a radius vector rather than a relative distance. And it is also found that the average effective magnetic moment of the particle calculated by the expression is in good agreement with the experimental value determined by Hirai.

  • PDF

Pulse-echo response of ultrasonic transducer fabricated with PZT-polymer 3-3 type composite (PZT-고분자 3-3형 복합압전체 소자로 제작된 초음파 트랜스듀서의 펄스에코 응답특성)

  • 박정학;최헌일;손무현;사공건
    • Electrical & Electronic Materials
    • /
    • v.9 no.10
    • /
    • pp.1053-1059
    • /
    • 1996
  • The pulse-echo response of the piezoceramics PZT-polymer 3-3 type composite transducers with various PVA additions were investigated. The PZT powder was prepared by the molten salt synthesis method. The porous PZT specimens will be used as a filler to make 3-3 type comosite were prepared from a mixture of PZT and polyvinylalcohol(PVA) sphere by utilizing BURPS(Bumout Plastic Sphere) technique. It was shown that the transmitting and receiving sensitivity of 3-3 type piezoelectric composite transducers could be improved than that of solid PZT transducers. The reason is that 3-3 type piezoelectric composite have low dielectric constant, density and acoustic impedance. The distance between transducer and reflector was in good agreement with the distance calculated from the longitudinal velocity of the specimens and receiving time observed pulse-echo responses on the ultrasonic transducer analyzer.

  • PDF