• Title/Summary/Keyword: distance relay

Search Result 238, Processing Time 0.024 seconds

A Study on Coil Misalignment in a 3-Coil Magnetic Resonance Wireless Power Transmission System of a Electric Vehicle (전기자동차의 3-코일 자기공진방식 무선전력전송 시스템에서 코일의 비 정렬에 관한 연구)

  • Hwang, In-Gab
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.1
    • /
    • pp.48-55
    • /
    • 2021
  • The 3-coil magnetic resonance wireless power transmission system was analyzed using an equivalent circuit model, and the |S21| of the system was expressed as the equation of the Q of the three coils, the coupling coefficient k between the transmitting coil and the relay coil, the relay coil and the receiving coil. It is suggested that the maximum efficiency can be obtained when the relay coil is located in the center of the transmitting and the receiving coil. When the distance between the transmitting and the receiving coil is 30 cm and the two coils are aligned, maximum efficiency of 9 % is obtained with the relay coil centered between the coils. If the transmitting coil and the receiving coil are misaligned during a wireless charging of an electric vehicle, the efficiency is expected to decrease significantly compared to the aligned case. It is expected that the efficiency can be increased by using a relay coil and by rotating the coil.

Study on 2BP Distance Bounding Protocol to Prevent Relay Attack in RFID environment (RFID 환경에서 중계공격을 방지를 위한 2BP Distance Bounding 프로토콜 연구)

  • Jung, Youn-Sung;Kim, Hyeong-Ju;Lee, A-Young;Jun, Moon-Seog
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.892-895
    • /
    • 2012
  • RIFD 시스템은 개체 인증, 전자결제 등 다양한 분야에서 사용되고 있다. 무선통신의 특성상 악의적인 공격자로부터 중계공격이 가능하여 공격자가 정당한 사용자로 가장할 수 있다. 이러한 중계공격을 예방하기 위하여 Distance Bounding이라는 개념의 프로토콜이 제안되어 왔다. 하지만, 기존 연구는 태그 ID 전달의 기밀성을 보장하지만 ID 검색의 비효율성 및 불필요한 두 번째 저속 단계가 존재하는 단점이 있다. 따라서 본 논문은 ID의 검색 없고, 시도 값과 응답 값을 2bits로 하여 마지막 저속 단계를 생략하며, 고속 단계에서 공격자의 공격 탐지 및 Terrorist 공격에 대하여 $(1/2)^n$의 공격 성공률을 갖는 2BP(2Bit 2Phase) Distance Bounding 프로토콜을 제안한다.

Design of 1× Optical Path Relay Adapter for Beam Splitting Prism used in Day & Night Scope (주야 관측경용 빔 분리프리즘을 위한 1× Optical Path Relay Adapter 설계)

  • Lee, Dong-Hee;Choi, Gyu-Jung;Jung, In;Park, Seung-Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.441-447
    • /
    • 2012
  • Purpose: This paper is about development and design of the 1x optical path relay adapter for the beam splitting prism by us the day & night scope. Methods: To product the day & night scope by using the beam splitting prism and the commercial zoom optical system with the C-mount lens barrel structure, the optical path relay adapter, which doesn't change the image size of the zoom optical system and can stretch the position of the image-forming surface, is needed. We could design the 1x optical path relay adapter by using the CodeV program in which the Lens Module mode is offered. Results: We could design the optical path relay adapter used in the day&night scope with the beam splitting prism, of which characteristics have the EFL of -56.0 mm, the magnification of +1.0x, the distance from the 1st lens surface to the last lens surface of about 20.4 mm. The resolution of this system is characterized by 30 lp/mm at 40% MTF. This is enough to accommodate the designed optical path relay adapter can overcome the resolution of the 3rd generation of image intesifier tubes. Conclusions: By designing and applying the optical path relay adapter of which optical characteristics have the EFL of -56.0 mm, the magnification of +1.0x, the distance from the 1st lens surface to the last lens surface of about 20.4 mm, and the resolution of 30 lp/mm at 40% MTF, we could develop the new type day&night scope consisting of the beam splitting, the commercial zoom optical system with the C-mount lens barrel structure, and the 3rd generation of image intesifier tubes.

Relay Protocol in DSRC System (DSRC 시스템에서 릴레이 프로토콜)

  • Choi Kwang-Joo;Choi Kyung-Won;Cho Kyong-Kuk;Yoon Dong-Weon;Park Sang-Kyu
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.9 s.351
    • /
    • pp.32-39
    • /
    • 2006
  • 5.8GHz DSRC(Dedicated Short Range Communications) is a short to medium range communications service that supports both public safety and private operations in roadside to vehicle and vehicle communication. However the 5.8GHz frequency may cause the shadowing effect or communication blocking problem when there is an obstacle or another vehicle between RSE (Road Side Equipment) and OBE (On Board Equipment). In this paper, to solve this problem of the 5.8GHz DSRC, we propose a relay protocol based on the standard of DSRC radio communication between RSE and OBE in the 5.8GHz band made by TTA (Telecommunication Technology Association). By using the proposed relay protocol to DSRC system and intervehicle communication, we also consider a fixed relay protocol and mobile relay protocol. We expect to apply this relay protocol for the DSRC intervehicle communication and video communication between drivers and safe distance among vehicles in the near future.

WAETER LEVEL CONTROL USING Z-80 MICROOMPUTER

  • Sugisaka, Masanori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1899-1903
    • /
    • 1991
  • This paper presents a water level control method using Z-80 microcomputer. The process considered in this paper is one tank system which is described by an unknown nonlinear differential equation. The water level is measured by the end of bar installed at a float passing through 8 pair of photointerrupters located at equal distance. Therefore, the input data to 8255 which is interface between Z-80 and photointerrupters is discrete value, namely, value under 1. values from 1 to 8, and value upper 8. The water is pumped into the tank from a reservoir by switching on a relay connected to a moter and pump driving system. The pumping is stopped by switching off the relay. Experimental studies for two types of controllers are performed in order to investigate the control performance of water level of the water pumping system.

  • PDF

A Study of Analysis of Fault Data in AC Electrical Railway Power System Based on COMTRADE Using PSCAD/EMTDC (PSCAD/EMTDC를 활용한 COMTRADE 기반의 교류철도 급전계통 사고 데이터 분석에 관한 연구)

  • Lee, Ji-Hye;Min, Myung-Hwan;An, Tae-Pung;Lee, Byeong-Gon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1542-1548
    • /
    • 2018
  • When any faults occurred in electrical railway system, operators need to analysis it quickly and accurately. Existing COMTRADE based analysis tools are not enough to analysis faults occurred in electrical railway system. In this paper, it presents some functions to fault analysis for electrical railway system based on fault data formatted COMTRADE. These functions are implemented in PSCAD/EMTDC and it can be shown that analyzed results against actual electrical fault cases which were occurred in the electrical railway power system.

Fault Detection Technique in Railway High Voltage Distribution Lines using Wavelet Transform (웨이브렛 변환을 이용한 철도 고압배전선로의 고장검출기법)

  • Jung Ho-Sung;Han Moon-Seob;Lee Chang-Mu;Kim Joorak;Lee Han-Min
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1274-1279
    • /
    • 2004
  • This paper proposes technique to detect ground fault in railway high voltage distribution lines. Overcurrent relay technique is widely used for detecting one line ground fault that occurs most frequently in railway high voltage distribution lines. However, ground fault in distribution line is usually high impedance fault with arc. Because the fault current magnitude measured in substation is very small, the conventional overcurrent relay can't detect the high impedance ground fault. Therefore this paper proposes the advanced technique using wavelet transform. It extracts D1 component from fault signals and detects fault comparing magnitude of D1 component in each phase. To evaluate this proposed technique, we model distribution system using PSCAD/EMTDC and extract various fault data. In conclusion this technique can detect ground fault including high impedance fault regardless of fault distance, fault impedance etc.

  • PDF

Two-Way Relaying-Based Two-Hop Two-User Multiple-Input Multiple-Output System

  • Cho, Young Seek;Choi, Seyeong
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.2
    • /
    • pp.67-74
    • /
    • 2014
  • In multi-hop communication systems, two-way relaying is one of the solutions to mitigate the spectral efficiency loss caused by a half-duplex transmission. In this paper, a simple two-way relaying scheme is proposed for two-hop two-user multiple input multiple output (MIMO) systems. In the proposed system, a base station and a relay station (RS), both equipped with two antennas, form a point-to-point MIMO channel, while the RS and two single-antenna mobile users form a point-to-multipoint multiuser (MU)-MIMO channel. Numerical examples show that the proposed system achieves a significant sum rate gain as compared to a one-way relaying system as the distance between a relay and the two users decreases. We also show that although we can expand the proposed scheme to more than two users, its performance gain as compared to that of one-way relaying decreases with an increase in the number of users.

Microprocessor based welding power meter (마이크로 프로세서를 이용한 용접전력 측정에 관한 연구)

  • 노창주;박상길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.33-40
    • /
    • 1987
  • Arc power is consumed energy per unit time between welding electrodes. The relations between consumed energy and electrode distance, current, voltage are nonlinear characteristics. Therefore commercial A.C. wattmeter cannot be used for measurement of the arc power. Most of arc energy measuring systems are developed for relay contact arc measurement. Relaly arc requires integrated instantaneous power because relay arc finishes in a short instant. But most of welding powers are continually consumed powers, therefore instantaneous power must be continually indicated in the form of averagy value. The author propose a new measurement method of power in which the current and voltage of welding electrode is multiplied and the resultant signal is passed to low pass filter in order to remove higher order frequency components. After integrating, the signal is devided by the integral interval and the results are stored in a computer memory.

  • PDF

Relay node selection algorithm consuming minimum power of MIMO integrated MANET

  • Chowdhuri, Swati;Banerjee, Pranab;Chaudhuri, Sheli Sinha
    • Advances in Computational Design
    • /
    • v.3 no.2
    • /
    • pp.191-200
    • /
    • 2018
  • Establishment of an efficient routing technique in multiple-input-multiple-output (MIMO) based mobile ad hoc network (MANET) is a new challenge in wireless communication system to communicate in a complex terrain where permanent infrastructure network implementation is not possible. Due to limited power of mobile nodes, a minimum power consumed routing (MPCR) algorithm is developed which is an integration of cooperative transmission process. This algorithm select relay node and support short distance communication. The performance analysis of proposed routing algorithm increased signal to noise interference ratio (SNIR) resulting effect of cooperative transmission. Finally performance analysis of the proposed algorithm is verified with simulated result.