• 제목/요약/키워드: distance calibration

검색결과 271건 처리시간 0.026초

격자형 선폭들의 투영변화비를 이용한 카메라 교정 파라메터 추정 (Camera calibration parameters estimation using perspective variation ratio of grid type line widths)

  • Jeong, Jun-Ik;Choi, Seong-Gu;Rho, Do-Hwan
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.30-32
    • /
    • 2004
  • With 3-D vision measuring, camera calibration is necessary to calculate parameters accurately. Camera calibration was developed widely in two categories. The first establishes reference points in space, and the second uses a grid type frame and statistical method. But, the former has difficulty to setup reference points and the latter has low accuracy. In this paper we present an algorithm for camera calibration using perspective ratio of the grid type frame with different line widths. It can easily estimate camera calibration parameters such as lens distortion, focal length, scale factor, pose, orientations, and distance. The advantage of this algorithm is that it can estimate the distance of the object. Also, the proposed camera calibration method is possible estimate distance in dynamic environment such as autonomous navigation. To validate proposed method, we set up the experiments with a frame on rotator at a distance of 1, 2, 3, 4[m] from camera and rotate the frame from -60 to 60 degrees. Both computer simulation and real data have been used to test the proposed method and very good results have been obtained. We have investigated the distance error affected by scale factor or different line widths and experimentally found an average scale factor that includes the least distance error with each image. The average scale factor tends to fluctuate with small variation and makes distance error decrease. Compared with classical methods that use stereo camera or two or three orthogonal planes, the proposed method is easy to use and flexible. It advances camera calibration one more step from static environments to real world such as autonomous land vehicle use.

  • PDF

Pushing precision and accuracy of RR Lyrae variables as distance indicators

  • Bhardwaj, Anupam;Yang, Soung-Chul
    • 천문학회보
    • /
    • 제46권2호
    • /
    • pp.80.3-81
    • /
    • 2021
  • RR Lyrae variables are excellent distance indicators thanks to their visual magnitude-metallicity relation and well-defined Period-Luminosity Relations (PLRs) at infrared wavelengths. These population II variables together with the tip of the red giant branch provide primary calibration for the first-rung of the population II distance ladder. We will present new empirical calibration of RR Lyrae PLRs at near-infrared wavelengths using our data from the ongoing CFHT-WIRCam RR Lyrae program. We will discuss the systematic uncertainties involved in the calibration of these relations based on the latest Gaia EDR3 parallaxes and the implication for the cosmic distance scale.

  • PDF

선폭들의 투영변화율을 이용한 카메라 교정 파라메터 추정 (The Camera Calibration Parameters Estimation using The Projection Variations of Line Widths)

  • 정준익;문성룡;노도환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2372-2374
    • /
    • 2003
  • With 3-D vision measuring, camera calibration is necessary to calculate parameters accurately. Camera calibration was developed widely in two categories. The first establishes reference points in space, and the second uses a grid type frame and statistical method. But, the former has difficulty to setup reference points and the latter has low accuracy. In this paper we present an algorithm for camera calibration using perspective ratio of the grid type frame with different line widths. It can easily estimate camera calibration parameters such as focal length, scale factor, pose, orientations, and distance. But, radial lens distortion is not modeled. The advantage of this algorithm is that it can estimate the distance of the object. Also, the proposed camera calibration method is possible estimate distance in dynamic environment such as autonomous navigation. To validate proposed method, we set up the experiments with a frame on rotator at a distance of 1,2,3,4[m] from camera and rotate the frame from -60 to 60 degrees. Both computer simulation and real data have been used to test the proposed method and very good results have been obtained. We have investigated the distance error affected by scale factor or different line widths and experimentally found an average scale factor that includes the least distance error with each image. It advances camera calibration one more step from static environments to real world such as autonomous land vehicle use.

  • PDF

자동차 안전운전 보조 시스템에 응용할 수 있는 카메라 캘리브레이션 방법 (Camera Calibration Method for an Automotive Safety Driving System)

  • 박종섭;김기석;노수장;조재수
    • 제어로봇시스템학회논문지
    • /
    • 제21권7호
    • /
    • pp.621-626
    • /
    • 2015
  • This paper presents a camera calibration method in order to estimate the lane detection and inter-vehicle distance estimation system for an automotive safety driving system. In order to implement the lane detection and vision-based inter-vehicle distance estimation to the embedded navigations or black box systems, it is necessary to consider the computation time and algorithm complexity. The process of camera calibration estimates the horizon, the position of the car's hood and the lane width for extraction of region of interest (ROI) from input image sequences. The precision of the calibration method is very important to the lane detection and inter-vehicle distance estimation. The proposed calibration method consists of three main steps: 1) horizon area determination; 2) estimation of the car's hood area; and 3) estimation of initial lane width. Various experimental results show the effectiveness of the proposed method.

멀티뷰 카메라를 사용한 외부 카메라 보정 (Extrinsic calibration using a multi-view camera)

  • 김기영;김세환;박종일;우운택
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 신호처리소사이어티 추계학술대회 논문집
    • /
    • pp.187-190
    • /
    • 2003
  • In this paper, we propose an extrinsic calibration method for a multi-view camera to get an optimal pose in 3D space. Conventional calibration algorithms do not guarantee the calibration accuracy at a mid/long distance because pixel errors increase as the distance between camera and pattern goes far. To compensate for the calibration errors, firstly, we apply the Tsai's algorithm to each lens so that we obtain initial extrinsic parameters Then, we estimate extrinsic parameters by using distance vectors obtained from structural cues of a multi-view camera. After we get the estimated extrinsic parameters of each lens, we carry out a non-linear optimization using the relationship between camera coordinate and world coordinate iteratively. The optimal camera parameters can be used in generating 3D panoramic virtual environment and supporting AR applications.

  • PDF

정밀 켈리브레이션 정합을 위한 화상측징계 (The Image Measuring System for accurate calibration-matching in objects)

  • 김종만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.357-358
    • /
    • 2006
  • Accurate calibration matching for maladjusted stereo cameras with calibrated pixel distance parameter is presented. The camera calibration is a necessary procedure for stereo vision-based depth computation. Intra and extra parameters should be obtain to determine the relation between image and world coordination through experiment. One difficulty is in camera alignment for parallel installation: placing two CCD arrays in a plane. No effective methods for such alignment have been presented before. Some amount of depth error caused from such non-parallel installation of cameras is inevitable. If the pixel distance parameter which is one of Intra parameter is calibrated with known points, such error can be compensated in some amount and showed the variable experiments for accurate effects.

  • PDF

2차원 격자 오차 데이터 기반의 선형 보정 함수들을 이용한 적외선 레인지 파인더 PBS-03JN의 보정 (alibration of Infra-red Range Finder PBS-03JN Using Piecewise Linear Function Based on 2-D Grid Error)

  • 김진백;김병국
    • 제어로봇시스템학회논문지
    • /
    • 제17권9호
    • /
    • pp.922-931
    • /
    • 2011
  • An efficient calibration algorithm for mobile robot localization using infrared range finder is proposed. A calibration is important to guarantee the performance of other algorithms which use sensor data because it is pre-process. We experimentally found that the infrared range finder PBS-03JN has error characteristics depending on both distance and scan angle. After obtaining 2-D grid error characteristic data on distance and scan angle, we proposed a simple and efficient calibration algorithm with a 2-D piecewise linear function set. The performance of our proposed calibration algorithm is verified by experiments and simulation.

큰 베이스라인을 가진 전방향 스테레오 카메라의 교정 방법 (Calibration Method for Omnidirectional Stereo Camera with Large Baseline)

  • 이강산;강현수
    • 한국콘텐츠학회논문지
    • /
    • 제10권6호
    • /
    • pp.10-17
    • /
    • 2010
  • 본 논문은 전방향 스테레오 카메라를 이용한 거리 측정을 위해 반드시 수행되어야 하는 전방향 카메라의 교정방법에 관해 기술한다. 전방향 스테레오 카메라의 교정에 있어서, 두 대의 전방향 카메라를 각각 독립적으로 교정하거나 두 대의 카메라의 베이스라인이 크지 않은 경우의 교정은 기존의 연구된 다양한 방법을 통해 가능하다. 그러나 전방향 스테레오 카메라를 이용하여 원거리를 측정하기 위해서는 베이스라인이 충분히 커야 하며, 충분히 큰 베이스라인은 두 대의 전방향 카메라를 동시에 교정하는 것이 매우 힘들다. 이는 두 대의 전방향 카메라에서 촬영된 교정을 위한 테스트패턴의 크기가 최소한 한 대의 전방향 카메라에서 매우 작은 크기로 나타나기 때문이다. 따라서 본 논문에서는 베이스라인이 큰 두 대의 전방향 카메라의 교정을 위한 방법을 제안하고 실험을 통해 검증한다.

단층촬영영상을 이용한 T.O.D Calibration의 정확성과 유용성에 관한 비교연구 (Comparative Study on Accuracy and Usefulness of Calibration Using CT T.O.D)

  • 서정범;김동현;이정범
    • 대한디지털의료영상학회논문지
    • /
    • 제13권1호
    • /
    • pp.39-48
    • /
    • 2011
  • Uses a Tomographic scan image and Table Object Distance(TOD) price after measuring, uses accuracy and usability of blood vessel diameter(Vessel Diameter) measurement under comparison evaluating boil TOD Calibration. The patient who enforces Prosecuting Attorney abdomen Tomographic scan in the object the superior mesentery artery uses PACS View from abdomen fault image and from blood vessel diameter and the table measures the height until of the blood vessel. Uses Angio Catheter from Angiography(5 Fr.) and enforces is measured from PACS View the height until of the table which and the blood vessel at TOD Calibration price and the size of the superior mesentery artery inputs measures an superior mesentery artery building skill. Catheter Calibration input Agnio Catheter where uses in Angiography the size of the superior mesentery artery at Catheter Calibration price and they measure. Produced an accuracy from monitoring data and comparison evaluated. The statistical program used SPSS. TOD Calibration accuracy was 96.53%, standard deviation is 0.03829. Catheter Calibration accuracy of 92.91%, standard deviation is 0.05085. Represents a statistically significant difference(p = 0). According to age and gender was not statistically significant(p > 0.05). TOD Calibration correlation coefficient R-squared of 88.8%, Catheter Calibration of the R-squared is 75.5%. High accuracy of both methods. Through this study, CT images using the measured distance between the table and the Object, TOD Calibration accuracy higher than two Catheter Calibration was measured. TOD and Catheter Calibration represents a statistically significant difference(p = 0).

  • PDF

레이저 간섭계를 이용한 광파거리측정기의 교정과 특성분석 (Calibration and Performance Test of Electro-optical Distance Meters Using a Laser Interferometer)

  • 김재완;엄태봉;서호성
    • 한국측량학회지
    • /
    • 제22권4호
    • /
    • pp.367-374
    • /
    • 2004
  • 대형 구조물의 측량에 널리 사용되는EDM(Electro-optical distance meter,광파 거리 측정기)의 측정값이 신뢰성을 가지기 위해서는 반드시 EDM의 교정이 필요하다. 본 연구에서는 EDM의 교정을 위한 소급체계를 확립하였는데, 이는EDM이 미터 정의로 부터의 소급성을 가지게 하는 것을 의미한다. 미터 정의에 따라 길이 표준기로 사용되는 요오드 안정화 헬륨­네온 레이저로 레이저 간섭계를 교정하고, 이 레이저 간섭계로 기준 EDM을 교정한 후, 기준 EDM과 기선장에 의해 교정 대상 EDM이 교정됨으로써 미터 정의로의 소급성을 유지한다. 레이저 간섭계를 이용한 EDM의 배율과 길이 측정값에 대한 교정 불확도는 각각 6$\times$$10^{-6}$과 0.2 mm이다. 기선장을 이용한 교정법과 EDM의 변조 주파수를 교정하는 교정법을 병행하여 그 결과를 비교하였다.