• Title/Summary/Keyword: distal value

Search Result 138, Processing Time 0.027 seconds

Interaction Effect Between Temporal Proximity of Utility Value and Self-efficacy on Interest (과제 유용가치의 시간적 근접성과 자기효능감의 상호작용이 흥미에 미치는 영향)

  • Woo, Yeon-kyoung;Kim, Sung-il;Bong, Mimi
    • (The) Korean Journal of Educational Psychology
    • /
    • v.28 no.1
    • /
    • pp.1-21
    • /
    • 2014
  • Two studies were conducted to investigate the interactive effect between temporal proximity of utility value and self-efficacy on situational interest and reengagement motivation. In study 1, university students were provided with either proximal or distal values of mental calculation task. Hierarchical regression analyses showed a significant interaction effect between distal utility value and high self-efficacy, indicating that distal utility value was more effective to induce situational interest and reengagement motivation for students with higher level of self-efficacy. In study 2, we replicated study 1 with high school students to investigate developmental differences and found the same results. These findings suggest that it is important to consider the level of self-efficacy and proximity of utility value in designing value intervention program.

Results of Minimal Incision Distal Metatarsal Osteotomy for Moderate to Severe Hallux Valgus (중등도 이상의 무지 외반증에서 최소 절개를 이용한 원위 중족골 절골술의 결과)

  • Huh, Jung-Wook;Eun, Il-Soo;Ko, Young-Chul;Park, Man-Jun;Park, Sook-Hyun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.2
    • /
    • pp.51-57
    • /
    • 2015
  • Purpose: Minimal incision distal metatarsal osteotomy (MIDMO) is known to be an effective surgical procedure for mild to moderate hallux valgus. However, the result of MIDMO on moderate to severe hallux valgus is controversial; therefore, we investigated the radiological and clinical results of MIDMO on moderate to severe hallux valgus. Materials and Methods: We reviewed 51 feet (48 patients) with moderate to severe hallux valgus. The mean age was 67.0 years and the mean follow-up period was 32.2 months. Radiological data of hallux valgus angle, first intermetatarsal angle, and distal metatarsal articular angle on plain radiographs were analyzed. Recurrence, union, lateral translation of distal fragment and angulation were also analyzed. The clinical data were obtained using American Orthopaedic Foot and Ankle Society (AOFAS) score of preoperation and last follow-up. Receiver operating characteristic (ROC) curve was used to determine a cut-off value. Results: The mean hallux valgus angle measured at preoperation was $37.7^{\circ}$ and $15.9^{\circ}$ at last follow-up. The mean first intermetatarsal angle of preoperation and last follow-up were $15.2^{\circ}$ and $8.3^{\circ}$. The mean distal metatarsal articular angle changed from $12.6^{\circ}$ at preoperation to $7.8^{\circ}$ at last follow-up. Preoperative hallux valgus angle (p=0.0051) and distal metatarsal articular angle (p=0.0078) were statistically significant factors affecting postoperative AOFAS score. Cut-off value of each was $37^{\circ}$ and 13o, respectively. Lateral translation of distal fragment in 5 recurrent cases was 23.0% compared to 45.3% of 46 non-recurrent cases. The result was statistically significant and the cut-off value was 38%. Conclusion: Sufficient lateral translation over 38% in MIDMO on moderate to severe hallux valgus patients with preoperative hallux valgus angle under $37^{\circ}$ and distal metatarsal articular angle under $13^{\circ}$ can lead to good clinical results without recurrence.

Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study

  • Lim, Joon-Ryul;Yoon, Tae-Hwan;Lee, Hwan-Mo;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.66-71
    • /
    • 2021
  • Background: Extra-articular distal humerus locking plates (EADHPs) are precontoured anatomical plates widely used to repair distal humeral extra-articular diaphyseal fractures. However, EADHPs frequently cause distal protrusion and resulting skin discomfort. The purpose of this study was to predict the occurrence of anatomic fit mismatch. We hypothesized that the smaller the humerus size, the greater the anatomic fit mismatch with EADHP. Methods: Twenty humeri were analyzed in this study. Humeral length and distal humeral width were used as parameters of humeral size. Plate protrusion was measured between the EADHP distal tip and the distal humerus. We set the level of unacceptable EADHP anatomic fit mismatch as ≥10 mm plate protrusion. Results: A significant negative linear correlation was also confirmed between humeral size and plate protrusion, with a coefficient of determination of 0.477 for humeral length and 0.814 for distal humeral width. The cutoff value of humeral length to avoid ≥10 mm plate protrusion was 293.6 mm (sensitivity, 88.9%; specificity, 81.8%) and for distal humeral width was 60.5 mm (sensitivity, 100%; specificity, 81.8%). Conclusions: Anatomic fit mismatch in distal humeral fractures after EADHP fixation has a negative linear correlation with humeral length and distal humeral width. For patients with a distal humeral width <60.5 mm, ≥10 mm plate protrusion will occur when an EADHP is used, and an alternative implant or approach should be considered.

A STUDY OF THE CHANGE OF MANDIBLE POSITION AND THE STABILITY AFTER ORTHOGNATHIC SURGERY (악교정 수술후 하악 근원심 골편의 위치 변화와 안정성에 관한 연구)

  • Nam, Kwang-Ho;Lee, Sang-Chull
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.2
    • /
    • pp.95-101
    • /
    • 2003
  • The purpose of this study was to evaluate the patterns of skeletal changes of proximal and distal segments after one jaw surgery and two jaw surgery with posterior impaction using SSRO on mandible in order to determine the skeletal origin of relapse and compare the stability of surgical methods in anterior open bite. The points and lines from lateral cephalometrics were measured before, after surgery, and at least 6-month follow up period. And then, the positional change of the proximal and distal segment were evaluated respectively. The results obtained were as follows; In cases of two jaw surgery, the results were stabler because they had less relapse factors. In cases of one jaw surgery, the value of APD were increased but it didn't relapse to the original value. Both of proximal and distal segments were responsible for the relapse tendency. But in one jaw surgery, the rotation of proximal segment was more responsible, and in two jaw surgery, the rotation of distal segment was.

Correction of Sesamoid after Proximal Metatarsal Osteotomy and Distal Soft Tissue Procedure in Hallux Valgus (무지외반증 치료에서 근위 중족골 절골술과 원위 연부조직 교정술 후 종자골의 교정정도)

  • Jung, Hwa-Jae;Shin, Hun-Kyu;Chang, Il-Sung;Lee, Jong-Keun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.74-80
    • /
    • 2005
  • Purpose: A retrospective review of the radiographs of the proximal metatarsal osteotomy and distal soft tissue procedure for hallux valgus, evaluating the correction of the tibial sesamoid, was undertaken. We evaluated the correlation between the reduction of the tibial sesamoid and the clinical outcomes. Materials and Methods: 17 patients (23 cases) with moderate to severe hallux valgus deformity underwent the proximal metatarsal osteotomy and distal soft tissue procedure. The preoperative and last follow-up radiographs were reviewed according to the tibial sesamoid grade classification recommended by the Research Committee of the American Orthopedic Foot and Ankle Society (AOFAS). We divided them into two groups according to the reduction of the tibial sesamoid. We anaylyzed the clinical outcomes in each group according to Mayo Clinic Forefoot Scoring System (FFSS). Results: In all of the patients, the preoperative tibial sesamoid position were grade 2 or greater. At the last follow-up, 52% (n=12) were grade 1 or less (Group I) and 48% (n=11) were grade 2 or greater (Group II). In group I, the forefoot score was improved from preoperative mean value of 32.0 points to final follow-up value of 66.3 points. In group II, the forefoot score was improved from preoperative mean value of 31.7 points to final follow-up value of 65.9 points. There was no statistical significance between postoperative, average scores in group I and II (p>0.05). Conclusion: The position of the tibial sesamoid was corrected insufficiently in almost half of all cases. In view of clinical outcomes, there was no significant difference between the corrected group and the other group.

  • PDF

The Effects of Retinoic Acid on the Regenerating Limbs of the Larval Korean Newt (Hynobius leechii) (한국산의 도롱뇽(Hynobius leechii) 유생의 다리재생에 미치는 Retinoic Acid의 효과)

  • 이해광;김원선
    • The Korean Journal of Zoology
    • /
    • v.33 no.3
    • /
    • pp.322-329
    • /
    • 1990
  • The effects of retinoic acid (RA) on the regenerating limbs of Korean newt (Hynobius leechii) larvae have been studied. Intraperitoneal injection of RA at 4 days post-amputation caused the proximalization of regenerate structures in the proximodistal (PD) axis of the limbs amputated through either the distal zeugopodium or the distal stylopodium. The mean level of proximalization (MLP) increased as a dose-dependent manner, and the MLP was also dependent on the level of amputation at a given dose of RA. At the dose of 150 $\mu$ g/g body wt., MLP's in either amputation level reached close to a peak value, and an increasing number of inhibition of regeneration or duplication in the transverse plane occurred at the dose of 200 $\mu$ g/ g body wt. and above. The changes induced by RA treatment suggest that positional values in the cells of the regenerating limbs have been modified in the three cardinal axes including PD and transverse axes in a graded mode. Furthermore, from the comparison of data in two different amputation levels, it can be speculated that the sensitivity of cells to RA effect along the PD axis might not be linear.

  • PDF

The Value and Limitation of the Modified Mau Osteotomy (30 Cases Follow Up Report) (변형 마우 절골 술기의 유용성과 한계점 (30예 추시 보고))

  • Bae, Su-Young;Kim, Byoung-Min;Nam, Hee-Tae;Choi, Hee-Joon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • Purpose: To evaluate the value and limitation of modified Mau osteotomy through the review of 30 feet treated by this procedure. Materials and Methods: We retrospectively analyzed 30 cases treated with modified Mau osteotomy since 2002. The mean duration of follow-up was 10 months. We reviewed medical records to describe each case and select several clinical factors which related with surgical procedure and could influence on final results. We measured radiographic parameters such as hallux valgus angle (HVA), intermetatarsal angle (IMA), distal metatarsal articular angle (DMAA), sesamoid position and also assessed clinical outcomes by AOFAS score and satisfaction degrees. Results: The mean preoperative HVA and IMA were $40.4^{\circ}$, $17.4^{\circ}$ and the mean amounts of correction were $31.2^{\circ}$ and $11.5^{\circ}$. Amounts of delayed loss of correction were 16.8% in HVA and 19.2% in IMA. Initial HVA, rotational angle and translation distance of the distal fragment, stability of fixation, first ray instability were revealed as significant factors for the final result from this procedure. DMAA was increased by rotation of the distal fragment and decreased by adding translation on the rotation. Conclusion: Modified Mau osteotomy is an effective procedure to get enough correction. But, it is important to try to avoid excessive rotation of the distal fragment because it may worse joint congruity. It may be worthwhile to pay close attention to the direction of saw and stability of fixation.

  • PDF

The Reliability of Kinematic Analysis for Distal Upper Extremity in Normal Person (정상인의 상지 원위부에 대한 운동학적 분석의 신뢰도)

  • Byun, Jae-Hyun;Hong, Wan-Ki
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.147-154
    • /
    • 2016
  • Purpose: To evaluate statistical differences among three measurements of range of motion (ROM) with Rapael Smart Glove (RSG) group 1, 2 and manual goniometer group. To investigate reference value of the kinematic analysis for range of motion (ROM) of distal upper extremity with Rapael Smart Glove (RSG). Methods: Sixteen normal persons without limitation of motion (LOM) enrolled in the study. The study was performed at two separate times and by two investigators on 16 normal adults. We compared ROM with RSG for measuring joint angles. We compared degrees of forearm supination/pronation, wrist flexion/extension and radial deviation/ulnar deviation during ROM of 16 participants using RSG. After one week, degrees of each motion were measured in the same way by other investigator to evaluate the reliability. Results: Statistical differences among three groups were showed. Most results of paired t-test between two RSG groups were over 0.05 and exceptions are supination, extension, and finger %. Conclusion: Our findings demonstrate that ROM of normal persons obtained by kinematic analysis with RSG are not valid as normal reference value for distal upper extremity motion. But, the reliability of between two RSG groups was showed with paired t-test and Pearson's correlation except supination, extension and finger %.

The Risk Factors Associated with Nonunion after Surgical Treatment for Distal Fibular Fractures (원위 비골 골절의 수술 후 발생한 불유합의 관련 인자)

  • Lee, Jun Young;Choi, Kwi Youn;Kang, Sinwook;Ko, Kang Yeol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.3
    • /
    • pp.95-99
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the radiologic outcomes of distal fibular fractures and to analyze the risk factors associated with nonunion. Materials and Methods: Between January 2009 and March 2016, 13 patients who had final nonunion with ankle fracture were included. In the control group, 370 patients who had undergone bony union and removed metal implants were included. All patients underwent the same surgical procedure and had the same treatment method, ultimately achieving satisfactory open reduction results with less than 2 mm fracture gap. Surgical treatment of fracture was considered to have the same effect on nonunion, and factors that might be associated with nonunion were evaluated. SPSS ver. 13.0 (SPSS Inc., USA) was used for all statistical analyses. Pearson's chi-square test and multi-variate regression analysis were performed to determine the factors affecting nonunion of distal fibular fracture. A p-value less than 0.05 was considered statistically significant, and relative risk was assessed. Results: The mean age of 13 patients was 46.9 years (range, 16~57 years); there were 8 men and 5 women. Among the 13 patients with nonunion, atrophic was the most common (12 cases). The association between the injury mechanism and the Lauge-Hansen classification and diabetes mellitus was not statistically significant. Distal fibular fractures with tibia shaft fracture (p=0.015) and Danis-Weber type C fracture (p=0.023), open fracture (p=0.011), and smoking (p=0.023) were significantly associated with nonunion. Conclusion: In this study, the combined injury of the ipsilateral tibia shaft fracture, open fracture, and Danis-Weber type C fracture may increase the possibility of nonunion. Therefore, caution is advised to prevent nonunion.

Assessment of Compensator Thickness in Proton Therapy (양성자 치료 시 사용되는 Compensator의 Thickness에 대한 적정성 평가)

  • Park, Yong Soo;Jang, Jun Yeong;Cho, Gwang Hyeon;Park, Yong Cheol;Choi, Byeong Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.35-40
    • /
    • 2018
  • Purpose : The range of force differs from the size of proton energy used in our hospital. The compensator enables to change energy size based on distal thickness which also makes changes in dose rate. Therefore, the purpose of this study is to evaluate the effect of changing the thickness of compensator distal on dose range and beam on time. Subject and Methodology : Five low energy patients who have received proton therapy were selected as subjects for this study. Beam on was checked for the selected patients during the existing therapy. After then, the thickness of distal of compensator was increased by 2 cm up to 14 cm through proton therapy plan system(TPS) for comparative analysis. For the evaluation of dose range, the value of the target's conformity index(CI) and the maximum dose of rear side target's organ at risk(OAR) were compared. Furthermore, to evaluate the effect of therapy time, beam on time was compared by making compensator distal in each thickness. Result : The result of homogeneity index and conformity index of the increased compensator distal showed the same level in all patients. The comparison results of OAR of target rear side showed 7 cGy at spine cord of abdomen at maximum, 88 cGy at eyeball's RT lens, 391 cGy at RT lens of nasal cavity 51 cGy at trachea of the mediastinum, and 661 cGy at a small bowl of the pelvis. The comparison results of the beam on time showed a reduction from 126 seconds to 62 seconds for the abdomen, from 105 seconds to 37 seconds for the eyeball, from 187 seconds to 134 seconds for nasal cavity, from 100 seconds to 40 seconds for mediastinum, from 440 seconds to 118 seconds for the pelvis. Conclusion : The research result showed that as the distal thickness of compensator increased, the size of energy increased. In addition, beam on decreased due to the increase of dose rate. It is expected that the result would help reduce the treatment time and increase the convenience of patients if it is applied to liver patients who need respiratorygated therapy and pediatric patients. However, distal penumbra increased as the size energy increased. Therefore, in treating cases where OAR is in the vicinity of the target rear side, the influence of penumbra should be taken into account in adjusting thickness level of the compensator in proton therapy plan.

  • PDF