• Title/Summary/Keyword: distal radial fracture

Search Result 11, Processing Time 0.025 seconds

Occupational Therapy Intervention for Malunion of Distal Radial Fracture: A Case Report

  • Noor Mohammad;Nahid Khan
    • CELLMED
    • /
    • v.13 no.6
    • /
    • pp.6.1-6.3
    • /
    • 2023
  • Objective: Malunion of distal radial fracture can result in pain, stiffness, and decreased function of the affected limb. Occupational therapy intervention can improve outcomes in these patients, but there is limited research on the effectiveness of such interventions. Case Description: This case report describes the occupational therapy intervention and outcomes for a 44-year-old female patient with malunion of left distal radial fracture. The patient received 8 weeks of occupational therapy intervention consisting of therapeutic exercises, joint mobilization, and fine motor activities. The patient demonstrated significant improvements in range of motion, grip strength, and activities of daily living (ADL) in her left hand. The patient also reported less pain and greater ease in performing activities of daily living. Conclusion: Occupational therapy intervention can be effective in improving outcomes for patients with malunion of distal radial fracture. This case report highlights the importance of early intervention and interdisciplinary collaboration among healthcare professionals to optimize patient outcomes. Further research is needed to explore the effectiveness of occupational therapy interventions for patients with malunion of distal radial fracture.

Clinical and Radiological Results of Treating Unstable Distal Radial Fractures with a Domestically Developed Volar Locking Plate That Has the Characteristic of Double-Tiered Subchondral Support (불안정성 원위 요골 골절의 치료에 있어 한국형 이중 연골하지지고정 전방 금속판의 임상적 및 방사선학적 결과)

  • Lee, Chul-Hyung;Jung, Deukhee;An, Chung-Han;Jeong, Uitak
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.495-502
    • /
    • 2020
  • Purpose: The aim of this study was to assess the effectiveness of domestically developed volar locking plate which has the concept of double-tiered subchondral support (DSS) in maintaining the reduction after distal radial fracture surgery. Materials and Methods: From July 2017 to December 2018, 54 patients were assessed. Plain radiographs were obtained immediately after surgery and at the last follow-up, and the radiographic parameters were measured in those images: radial length, radial inclination, volar tilt, ulnar variance, and distal dorsal cortical distance. The patients were subdivided into their age, type of fracture, and the position of the plate to evaluate the influence of each factors on the reduction maintenance. Results: Distal dorsal cortical distance in radiographs after the surgery was 5.91 mm (standard deviation, ±1.95 mm) on average. Significant differences in the radial length (p=0.038) and ulnar variance (p=0.001) were observed between immediately after surgery and at the last follow-up. When the parameters were evaluated by dividing the patients into subgroups according to the three specific factors, the ulnar variance showed a significant increase at the last follow-up when the patients were included 65-years-old or older. AO/OTA type C3 fracture, and Soong classification grade 0 plate position (p=0.007, p=0.012, p=0.046, respectively). Conclusion: Using the domestically developed DSS-type volar locking plate, significant reduction after distal radial fracture surgery could be maintained successfully. On the other hand, further study will be needed to determine about the reduction loss of the lunate facet identified in special cases that deal with fractures in elderly patients, unstable AO/OTA type C3 distal radial fractures, and Soong classification grade 0 plate position.

Hematogenous Osteomyelitis Following Open Fracture in a Cat

  • Hwang, Ya-Won;Lee, Jang-Mi;Choi, Seok-Hwa;Kim, Gon-Hyung
    • Journal of Veterinary Clinics
    • /
    • v.33 no.2
    • /
    • pp.135-137
    • /
    • 2016
  • A 6-month-old, weighing 2.8 kg, female, domestic short-haired cat presented with open fracture at right distal radius about a month ago. Based on radiological findings, hyperplasia at the right radioulna and left humerus was found. Results of the cytological examination were inflammatory reaction and reactive osteoblast. Distal radial ostectomy proceeded with necrotic bone debridement. Three weeks after operation, the radial bone lysis was seen on radiograph but clinical condition improved. Hyperplasia at the right radioulna and left humerus was dissolved. Two months after operation, she can use her both forelimbs despite right elbow have been diagnosed as arthrosclerosis because of periosteal reaction. Six months after operation, clinical symptoms of limbs were not detected. In this case, open fracture was treated through delayed surgical debridement procedure, therefore hematogenous osteomyelitis occurs at another forelimb. The longer a wound remains open, the more likely it is that infection will develop. The infection can occur to fracture bone and seed from hematogenous spread to another normal bone. In conclusion, when open fracture occurs, early antibiotic treatment and urgent surgical intervention are recommended.

Delayed Diagnosis of Volar Dislocation of the Distal Ulna after Treatment of the Radial Shaft Fracture (요골 간부 골절 치료 후 지연 발견된 원위 척골의 전방 탈구)

  • Jeon, Suk Ha;Lee, Sanglim
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.427-432
    • /
    • 2021
  • Delayed treatment of volar dislocation of the distal radioulnar joint can result in wrist pain, limited rotation of the forearm, and degenerative arthritis that could be managed only by salvage procedures. A 24-year-old male patient presented with wrist pain and a loss of forearm rotation after surgery for a radial shaft fracture. The shaft of the radius was fixed with a plate and screws with a volar angulation of 7°. The ulnar head was dislocated volar to the distal radius, and the bone defect in the ulnar head was impacted into the volar rim of the sigmoid notch of the radius, preventing the head from being reduced in the joint. Corrective osteotomy of the malunited radial shaft and sliding osteotomy of the proximal ulnar head were performed to fill the distal bone defect. Pain and range of the forearm rotation were improved at postoperative 19 months.

The Clinical usefulness of the tangential projection view of Radius groove after Distal Radius Fracture operation using the T-type Plat (전방 잠금형 금속판을 이용한 요골 원위부 골절수술 후 요골구 접선방향 촬영법의 임상적 유용성)

  • Seo, Sun-Youl;Cho, Jeong-Hee;Han, Man-Seok;Kim, Tae-Hyung;Yoo, Se-Jong;Kim, Yong-Kyun;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2760-2766
    • /
    • 2013
  • Introduction : The projection method to check existence and nonexistence of radius groove penetration of screw after distal radius fracture operation clinical using the T-type plate and the radiation of radial groove tangential is to propose a new test. Material and Methods : On the tangential projection view of radius groove, elevation angle of distal radius is 2.5, 5, 7.5, 10 degree. and forearm and radiation detector of angle is 60, 70, 80, degree each changed. that analyzed check existence and nonexistence of radius groove penetration of screw. Results : For the image of Radial groove tangential. the case of not radius groove penetration of screw(63.95%, n=55), medial penetration of radius groove(10.47%, n=9) or lateral penetration of radius groove(25.58%, n=22) was analysis. The radius groove penetrating of screw length was a range of 0.43 ~ 2.72mm, the average was 1.06mm. the check existence and nonexistence of radius groove penetration of medial or lateral was analysis that it accurate for the image of Radial groove tangential. the radiography of radial groove is well described elevation angle of distal radius 2.5 to 7.5 degree(90% over), forearm and radiation detector of angle 70degree(80%over) Conclusion : It is elevation angle of distal radius is 5degree, forearm and radiation detector of angle 70degree recommended.

A modified trans-anconeus approach to facilitate fixation of a posterior radial head fracture: a cadaveric feasibility study

  • Ahmed Mohamed Desouky;Ahmed Naeem Atiyya;Mohamed Elbishbishi;Marwa Mohamed El Sawy
    • Anatomy and Cell Biology
    • /
    • v.56 no.1
    • /
    • pp.39-45
    • /
    • 2023
  • Fixation of radial head fracture with minimally invasive posterior approach remains a significant challenge. The aim of this study was to determine the feasibility of trans-anconeus posterior elbow approach and to observe lateral ulnar collateral ligament (LUCL) in extended elbows. This cadaveric study was performed in twenty upper limbs of fresh fixed adult male cadavers. An oblique incision was made in the middle segment of anconeus until the lateral ligament complex and the joint capsule had been revealed. A deep dissection was explored to observe the anatomical relationship of the LUCL to the anconeus. Measurements of the LUCL were recorded while the elbow was fully extended. The mean distance between the edge of the radial head and the proximal insertion of the LUCL was 13.3 mm (11.5-16.2 mm); the mean distance between the edge of the radial head and the distal insertion of the LUCL was 20.9 mm (19.2-23.4 mm); the distance between the edge of the radial head and the distal edge of the annular ligament was 11.2 mm (8.22-11.7 mm). By estimate correlation of the previous measurements, the direct and accessible way to expose the posterolateral articular capsule of the elbow joint was through a window in medial 2/3 of the middle segment of anconeus muscle. These trans-anconeus approach is useful. It provides good visualization, facilitates applying the implants, and lessens the risk of radial nerve injury. Awareness of the anatomy is mandatory to avoid injury of LUCL.

Characteristics of Wrist Injuries in Snowboarding (스노보드 손상 환자에 있어서 손목 손상의 특성)

  • Kim, Yeong Jun;Lee, Kang Hyun;Cha, Kyoung Chul;Kim, Hyun;Hwang, Sung Oh;Oh, Jin Rok
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.29-36
    • /
    • 2009
  • Purpose: The purpose of this study was to analyze the characteristics and severity of wrist injuries in snowboarding. Methods: December 2005 to February 2008, Snowboarders who experienced wrist injures were included in this study. On the basis of the medical records and radiographic evaluation, the severity of distal radius fracture was classified according to the Arbeitsgemeinschaft fur Osteosynthesefragen/Association for the Study of Internal Fixation (AO/ASIF) classification. Results: Most of the injured snowboarders were a either of the beginner (35 cases, 46.1%) or the intermediate (27 cases, 35.5%) level. The most common cause of injury in snowboarding was a slip down (60 cases, 78.9%). Comminuted and articular fractures classified as AO types A3, B, and C, which required surgical reduction, made up 42.3% of the distal radial fractures in snowboarders. When we analyzed the differences in severity between the educated and the non-educated groups, an A2 type injury in the AO classification was the most common type of injury in the educated group (20 cases, 38.5%), it means less severe fractures ocurred in the educated group (p=0.045). The most frequent injury mechanism of fractures was slip down (48 cases, 63.2%), and a slip down backwards was the dominant type of slip down (36 cases, 75.0%) (p=0.031). Conclusion: Among the snowboarders in this study who suffered self-down injury to the wrist, more fractures were associated with a backwards slip down than with a forward slip down due to over extension. For educated snowboarders the severity of fracture was lower than it was for uneducated snowboarders.

Comparison of Three Surgical Method Outcomes for Dorsal Communition Distal Radial Fractures: External Fixation, External Fixation with Allogenous Bone Graft (DBM) and Volar Locking Plate Fixation (배측 분쇄가 있는 원위부 요골 관절내 골절의 3가지 수술적 치료 결과 비교: 외고정 기구 단독, 외고정 기구와 동종골이식 및 수장측 잠김 압박 금속판)

  • Choi, Joon-Cheol;Na, Hwa-Yeop;Lee, Young-Sang;Kim, Woo-Sung;Oh, Kyung-Soo;Song, Woo-Suk;Kim, Se-Jun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.115-120
    • /
    • 2009
  • Purpose: To evaluate the outcomes of three different surgical approaches in treating a distal radius fracture with dorsal communition. Materials and Methods: From April, 2006 to May, 2009, 49 patients over age of 60years old with unstable dorsal communition distal radius fracture were analyzed. We compared maintainability of reduction by radiological follow-up observations and clinical outcomes using Mayo wrist scores. One-Way ANOVA test was performed to examine the statistical correlation between the methods. Results: All three approaches provided satisfactory post-op reduction results. However, follow-up observations showed significant loss of reduction in the external fixation only group compared to the added bone graft group and the volar anatomical locking plate group (P<0.05). Mayo wrist score was indifferent between the three groups. Conclusion: Treatment of a distal radius fracture with severe dorsal communition using an external fixation only appears to be insufficient in maintaining reduction of a cancellous bone defect.

  • PDF

In vivo 3D Kinematics of Axis of Rotation in Malunited Monteggia Fracture Dislocation

  • Kim, Eugene;Park, Se-Jin;Jeong, Haw-Jae;Ahn, Jin Whan;Shin, Hun-Kyu;Park, Jai Hyung;Lee, Mi Yeon;Tsuyoshi, Murase;Sumika, Ikemototo;Kazuomi, Sugamoto;Choi, Young-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.25-30
    • /
    • 2014
  • Background: Normal elbow joint kinematics has been widely studied in cadaver, whilst in vivo study, especially of the forearm, is rare. Our study analyses, in vivo, the kinematics of normal forearm and of malunited forearm using a three-dimensional computerized simulation system. Methods: We examined 8 patients with malunited Monteggia fracture and 4 controls with normal elbow joint. The ulna and radius were reconstructed from CT data placing the forearm in three different positions; full pronation, neutral, and full supination using computer bone models. We analyzed the axis of rotation 3-dimentionally based on the axes during forearm rotation from full pronation to full supination. Results: Axis of rotation of normal forearm was pitch line, with a mean range of 2 mm, from full pronation to full supination, connecting the radial head center proximally and ulnar fovea distally. In normal forearm, the mean range was 1.32 mm at the proximal radioulnar joint and 1.51 mm at the distal radioulnar joint. However in Monteggia fracture patients, this range changed to 7.65 mm at proximal and 4.99 mm at distal radoulnar joint. Conclusions: During forearm rotation, the axis of rotation was constant in normal elbow joint but unstable in malunited Monteggia fracture patients as seen with radial head instability. Therefore, consideration should be given not only to correcting deformity but also to restoring AOR by 3D kinematics analysis before surgical treatment of such fractures.

Segmented Ulnar Transposition to Defect of Ipsilateral Radius in the Forearm (전완골 분절의 전위 이식술)

  • Chung, Duke-Whan;Han, Soo-Hong;Lee, Jae-Hoon;Kwon, Boo-Kyung
    • Archives of Reconstructive Microsurgery
    • /
    • v.16 no.2
    • /
    • pp.125-132
    • /
    • 2007
  • Introduction: Ulna is nearly equal to radius in function and bony architecture and strength in forearm. But in lower extremity, fibula is 1/5 of tibia in anatomic and functional point so we can find fibula transposition is commonly used in defect of tibia. We cannot find other article about segmental forearm bone transposition in man. The purpose of this study was to report our clinical and functional result of undergoing segmented transposition of ipsilateral ulna with its own vascular supply in defect of radius in 6 cases. Material and method: From June 1994 to October 2007, 7 segmented bone transpositional grafts in forearm were performed in Kyung Hee Medical Center. The distribution of age was from 20 years old to 73 years old. There was male in 6 cases and female in 1 case. The causes of operation were giant cell tumor in 1 case and traumatic origin in 6 cases; it was nonunion in 2 cases and fracture with severe comminution in 4 cases. Ipsilaterally segmented ulna keeping its own vascular supply was transported to defect of radius in severe traumatic patients and one patient whose tumor in radius had been excised. Transported ulna was fixed to proximal and distal radius remnants by plate and screw. In one case with giant cell tumor, transported ulna was connected to radius across wrist joint as wrist joint fusion. Joint preserving procedures were performed in 6 cases with crushing injury of radius. Results: We could obtain solid bony union in all cases and good functional results. The disadvantage was relative shortening of forearm, but we could overcome this problem. Conclusion: We think that ipsilateral segmented ulna transposition keeping its own vascular supply to radius can be perfomed with one of procedures in cases with wide defect in radius.

  • PDF