• 제목/요약/키워드: distal extension removable partial denture

검색결과 36건 처리시간 0.025초

직접유지장치 설계 변화에 따른 하악 후방연장 국소의치 지지조직의 광탄성 응력분석 (PHOTOELASTIC STRESS ANALYSIS ON THE SUPPORTING TISSUE OF MANDIBULAR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE WITH VARIOUS DESIGN OF DIRECT RETAINERS)

  • 이창호;김광남;장익태
    • 대한치과보철학회지
    • /
    • 제30권2호
    • /
    • pp.203-224
    • /
    • 1992
  • The purpose of this study was to evaluate the stress distribution developed in supporting structures by distal extension removable partial denture with 4-types of direct retainer. The direct retainers examined were Akers clasp, RPI clasp, RPA clasp and RPL clasp in bilateral & unilateral free end case. 3-dimensional photoelastic stress analysis was used to record the isochromatic fringe patterns and to calculate the compressive stress at measuring points. The results were as follows. 1. In bilateral free end case, RPI clasp exhibited the similar stress distribution on distal and mesial alveolar crest but Akers clasp exhibited higher stress concentration on distal alveolar crest than mesial alveolar crest. 2. In bilateral free end case, RPA clasp and RPL clasp exhibited the similar stress distribution on distal and mesial alveolar crest and RPL clasp exhibited higher stress concentration on buccal alveolar crest than lingual alveolar crest. 3. Akers clasp produced high stress concentration on residual alveolar ridge distally, but RPI clasp, RPA clasp and RPL clasp produced even stress distribution on residual alveolar ridge. 4. Removable partial denture in unilateral free end case exerted higher stress on abutment tooth root apex than bilateral distal extension removable partial denture.

  • PDF

임플란트를 이용한 국소의치 수복 (Implants in conjunction with removable partial denture)

  • 김성균;유수연;박인필;이주희
    • 대한치과의사협회지
    • /
    • 제49권2호
    • /
    • pp.77-84
    • /
    • 2011
  • The benefits of implant supported overdenture are readily apparent for the fully edentulous patients and have been well documented, however, there is deficiency of the studies regarding the combination of implants with removable partial dentures for partially edentulous patients. The purpose of this article is to review the literature concerning implants with removable partial dentures and evaluate the evidence for this clinical approach. Through many clinical case reports and studies we have searched from a broad variety of journals, we present the six considerations needed to contemplate respecting implants with removable partial denture in partially edentulous patients. First, the connection between abutment tooth and removable partial denture has to be rigid and the link between implant and removable partial denture should be hinged. Second, a mesial rest acts better in the point of force distribution for distal extension removable partial denture and splinting between implants is also a favorable choice. Third, T bar has an advantage for implants which are used as abutments in distal extension removable partial denture. Forth, as we all known functional impression is better way to reproduce movement for distal extension removable partial denture. Fifth, indirect retainer and guiding plane on the proximal surfaces of terminal abutment teeth are important in preventing denture base lifting. Sixth, implants in conjunction with removable partial denture is superior in the esthetic and phonetic as well as cost-effective point of view. We also suggest that which place we should install implants for force distribution and which diameter and length of implants should be used. in this review article, we recommend to locate the implant near of the abutment tooth for esthetics or near of first molar position for good stress distribution. The diameter and length of implant also influence to stress distribution. When we compare to conservative partial denture, patients go for removable partial denture using implants due to convenience, better support and retention according to several studies. But it is true that we need to study more on this subject and collect long term follow up cases before we discuss on it. So it is enough to bring this subject into the surface of prosthetic treatment by this article.

후방연장 국소의치에서 지대치의 splinting에 따른 치주조직의 응력 변화에 관한 유한요소법적 연구 (FINITE ELEMENT ANALYSIS OF STRESS PATTERNS ON PERIODONTIUM OF SPLINTED ABUTMENTSFOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE)

  • 황재웅;장익태;김광남
    • 대한치과보철학회지
    • /
    • 제33권2호
    • /
    • pp.241-268
    • /
    • 1995
  • Splint therapy, the immobilization of teeth, has been done for patient's masticatory comforts and an adjunctive aid in periodontal therapy. Mandibular premolars are frequently splinted in many distal extension removable partial denture cases. But splinting is an extensive restoration that may not be conservative of tooth structure and may prove to be quite costly to the patient. The two dimensional finite element analysis method was used to determine the magnitude and mode of distribution of the stresses of the periodontal ligament and supporting alveolar bone when abutments with different periodontal supports were splinted and distal-extension removable partial denture was subjected to different loading schemes. The results were as follows : 1. When abutments were splinted, stresses moved from apico-distal to apico-mesial of terminal abutment on a vertical force and from disto-alveolar crest to apex on a distally directed force. But stresses were generally diminished on a mesially directed force. 2. As vertical bone loss was proceeding, most of stresses were transmitted to residual ridge and the rest of stresses were concentrated on apex of distal abutment. But these apical stresses were minimized when abutments were splinted. 3. As mesially inclined bone loss was proceeding, it seemed to be dangerous that many stresses were concentrated on the distal alveolar crest, especially in the distally directed load case. Abutments splinting decreased the alveolar crestal stresses but not enough. 4. For all vertical stresses were effectively decreased on splinting, stresses were concentrated as highly on apico-mesial area of distal abutment in distally directed load cases as the distal inclination of bone level was severe. 5. The directions and magnitudes of abutment movements were decreased with teeth splinting.

  • PDF

유리단 국소의치에서 Suprabulge Clasp와 Infrabulge Clasp가 지대치 동요에 미치는 영향에 관한 연구 (Effect of Suprabulge Clasp and Infrabulge Clasp on the Mobility of Abutment Teeth for Distal Extension Removable Partial Dentures)

  • 임순호
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.39-45
    • /
    • 1981
  • Distal-extension removable partial dentures have long been implicated in the increase in mobility and the destruction of the supporting structures of the primary abutment teeth. Various clasping systems have traditionally been used to retain distal extension removable partial dentures, and other designs have been proposed to minimize torquing forces on the abutment teeth. Most recent studies investigating the effects of removable partial dentures on abutment teeth have been performed in it laboratory setting. Results obtained from in vitro research have given dentists insight into removable partial denture design, but laboratory test model cannot be constructed that simulates actual functional or parafunctiona1 movements and forces. The purpose of this study was to clinically evaluate the degree of tooth mobility produced by two clasping systems (suprabulge type and infrabulge type) used for distal extension removable partial dentures. Akers clasp and R.P.I. system were selected for the evaluation, and four patients required a distal extension removable partial denture on the mandibular arch were selected for participation in the study. Two partial dentures were constructed in the same condition expect the design of clasp. All abutments in the study were mandibular first or second premolars. Measurements of mobility were made with a research tool designed by $M\"{u}hlemann$. This instrument, periodontometer, measures tooth mobility in the mouth by means of a dial gauge accurated to 0.01mm when the tooth is stressed with a force meter. Lingual and buccal deflection of abutment tooth was measured using buccal and lingual pressure. The amount of force applied was 500gm. Tooth mobility tests were made at four key stages; 1. Before insertion of the first removable partial denture, baseline mobility was establsihed. 2. After wearing of the first prosthesis, measurement was made at weekly intervals for 4 weeks. 3. The removable partial denture was then taken from the patient, and tooth mobility was measured again at weekly intervals until the patient's established baseline mobility had returned. 4. The second prosthesis of different clasp design was worn for a month and evaluated in the same manner as the first. The sequence of placement of clasping system was alternated between patients. The following results were obtained from this study; 1. The mobility of abutment tooth increased during the initial stage of wear and returned to baseline mobility after removal of removable partial dentures. 2. The mobility of abutment tooth showed no difference between Akers clasp and I-bar clasp during the 4-week test period. 3. All teeth tested showed greater mobility toward the buccal than the lingual direction.

  • PDF

STRAIN ON THE LABIAL PLATES AROUND ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES WITH VARIOUS PROSTHETIC DESIGNS: AN IN VITRO STUDY

  • Kim, Seong-Kyun
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.322-330
    • /
    • 2005
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1 : Clasp-retained mandibular removable partial denture with unsplinted abuhnents Group 2 : Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge Group 3 : Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm close to the abutments. Two vertical experimental loadings (100N and 200N) were applied subsequently via two miniature load cells that were placed at mandibular first molar regions. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Duncan test was used as post hoc comparisons. Results. Strain values increased as the applied load increased from 100N to 200N for all groups (p<.05). The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Under 100N loading, group 1 showed higher strain values than group 3 in absolute quantity (p<.05). Under 200N loading, group 3 showed higher strain values than group 1 and 2 in absolute quantity (p<.05). Group 1 showed higher strain values than group 2 (p<.05). Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments. Strain of bar-retained removable partial denture increased much more as applied load increased, but was compressive in nature.

하악 편측 소수치 잔존 환자에서 임플란트 고정성 보철물을 사용하여 양측성 후방 연장 국소의치로 수복: 증례보고 (Restoration of bilateral distal extension removable partial denture using a fixed implant prosthesis in unilateral partial edentulous patient: A case report)

  • 기원진;박재호;임현필;윤귀덕;박상원
    • 대한치과보철학회지
    • /
    • 제57권2호
    • /
    • pp.176-181
    • /
    • 2019
  • 편측 부분 무치악에서 소수의 치아로 지대치를 형성하여 가철성 국소의치 제작 시 환자의 불편함 및 지대치 손상 등으로 인해 만족도가 낮아질 수 있다. 최근 편측 부분 무치악에서 임플란트 고정성 보철물을 지대치로 사용하여 양측성 후방 연장 국소의치로 제작하는 방법이 보고되고 있다. 본 증례에서 임플란트 고정성 보철물을 사용하여 환자의 수직 악간관계를 보존하고 본인의 치아와 같은 형태를 부여하여 환자에게 심리적 안정감을 주며 향상된 저작 기능의 결과를 제공하였다. 또한 임플란트 고정성 보철물을 통하여 예후가 불량할 것으로 예상되는 편측성 후방 연장 국소의치를 역학적, 기능적으로 유리한 양측성 후방 연장 국소의치를 제작하였다. 국소의치의 지지, 유지, 안정 요소의 향상을 가져왔으며 환자에게 경제적 및 사용 시 만족감을 가져왔다.

전방 임플란트 써베이드 고정성 보철물과 후방연장 국소의치를 이용한 전악 보철 치료의 3년 경과 관찰 증례 (Three-year follow-up of full mouth rehabilitation with anterior implant surveyed bridges and distal extension removable partial denture)

  • 길기성;이효경;김경아;이정진;서재민
    • 대한치과보철학회지
    • /
    • 제56권3호
    • /
    • pp.218-226
    • /
    • 2018
  • 부분 무치악 환자에게 소수의 임플란트를 전략적인 위치에 식립하여 추가적인 유지와 지지를 얻는 임플란트 보조 국소의치(Implant-assisted removable partial denture, IARPD)를 제작할 수 있다. 최근 이러한 임플란트 보조 국소의치로 치료한 여러 증례와 임상가이드라인을 보면 후방 무치악 부위에 임플란트를 식립하는 것이 추천된다. 그러나 실제 임상에서는 구치부의 심한 치조골 흡수나 해부학적 이유로 외과적 수술(상악동거상술, 골 이식술 등)이 부가적으로 필요한 경우가 많다. 이에 대해 후방의 무치악 부위는 가철성 국소의치로 수복하되, 소수의 치아가 잔존하는 전방 무치악 부위는 임플란트 고정성 보철물로 수복하여 지대주로 활용하는 치료방법이 대안으로 제시될 수 있다. 본 증례는 상악 구치부 치아의 상실과 잔존치열에 중등도 이상의 마모를 보이는 환자에 대한 증례로 상악 전방부에 3개의 임플란트를 식립하고 잔존하는 상악 전치부 자연치와 더불어 각각 써베이드 고정성 보철물을 제작하였으며 상악 후방연장 국소의치를 제작하였다. 그와 함께 손상된 하악 자연치는 고정성 보철물로 전악수복하였다. 이로써 감소된 수직고경 및 붕괴된 교합평면을 회복하여 기능적, 심미적으로 향상되었으며 지속적인 경과관찰 중이다. 본 증례를 통해 전방부 임플란트 써베이드 고정성 보철물과 후방연장 국소의치에 의한 보철치료 증례의 3년 경과관찰 결과를 보고하고자 한다.

국소의치 유지장치의 설계변화에 따른 지지조직의 3차원적 유한요소법 응력분석 (A 3-DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS ON THE SUPPORTING TISSUES OF REMOVABLE PARTIAL DENTURES WITH VARIOUS RETAINER DESIGNS)

  • 김기숙;김광남;장익태
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.413-439
    • /
    • 1995
  • The purpose of this study was to evaluate the stress distribution developed in the supporting structures by mandibular distal extension removable partial dentures with 2 different direct retainer designs and with or without indirect retainer and abutment splinting. The examined direct retainers on the second bicuspid abutment tooth were Akers clasp and RPA clasp, the indirect retainer was located on the mesial fossa of the first bicuspid, and the first and second bicuspid were splinted in case of tooth splinting. Total 8 cases were compared and analyzed with 3-dimensional finite element method. 150N were applied vertically on the artificial teeth of the removable partial denture, and then stress distribution patterns were analyzed and compared. The results were as follows : 1. The forces transmitted to the abutment tooth were primarily from the occlusal rests. 2. The abutment tooth was displaced distally when the force was applied. The compressive stress was observed at the distal root surface of the abutment tooth and the tensile stress, at the mesial root surface. 3. The denture base was displaced posteriorly and inferiorly when the force was applied. At the more distal portion of the denture base, the greater displacement was observed.And the anterior portion of the major connector was displaced superiorly. 4. The occlusal rest placed on the distal part of the abutment tooth tended to tip the tooth more posteriorly than did one on the mesial part of that tooth. 5. Severe superior displacement was observed at the anterior portion of the major connector in case of removable partial dentures without indirect retainer. 6. In case of tooth-splinting, the stress was distributed through all the root surface of both abuments. In case of no tooth-splinting, the stress was concentrated on the distal root surface of the primary abutment.

  • PDF

telescope형 및 Clasp형 유지장치를 이용한 국소의치 지지조직의 응력분포에 관한 삼차원 유한요소법적 연구 (A STUDY ON THE STRESS DISTRIBUTION OF ABUTMENT TEETH AND RESIDUAL RIDGE AREA BETWEEN TELESCOPIC AND CLASP TYPE RPD BY FEM METHOD)

  • 곽재영;김광남;장익태;허성주
    • 대한치과보철학회지
    • /
    • 제37권1호
    • /
    • pp.104-126
    • /
    • 1999
  • The purpose of this study was to compare and evaluate the stress distribution and displacement developed in the abutment teeth and residual ridge area by madibular unilateral distal extension removable partial denture with 2 different retainer designs. The retainers on right and left canine and right 2nd molar were Alters clasp in one model and telescopic crown in the other model. The stress distribution of abutment teeth and residual ridge area on two model were compared and analyzed with 3-dimensional finite element method. 150N and 400N forces were applied vertically, 30 degree and horizontally on the central fossa area of left 1st molar of the removable partial denture, and then stress distribution patterns were analyzed and compared. The results were as follows 1. As the magnitude and angulation of applied force were increased, the magnitude of stress on the right and central residual ridge area and the right canine of the telescopic type increased and comparing to those of the Alters clasp type. 2. As the magnitude and angulation of applied force were increased, the mesial direction of displacement on the right residual ridge area and the right tooth of the telescopic type increased and the distal direction of displacement on left residual ridge area and the left canine increased comparing to those of Akers clasp type. 3. As the vertical force was applied, the distal direction of the displacement of the right tooth were greater and that of the left canine was smaller and the upward displacement of the right canine was greater in telescopic partial denture than those of Akers clasp type. 4. As the 30 degree force was applied, the mesial direction of the displacement of the right tooth were greater and the distal direction of the displacement of the left canine was smaller and the upward displacement of the right canine was greater in telescopic partial denture than those of Akers clasp type. In the horizontal force the results were same in right area tooth but the distal direction of displacement was greater in left canine. 5. In both removable partial dentures, as the magnitude and degree of force were increased, the stress and displacement were increased. The compressive force was dominative than the ten sile force. 6. In both removable partial dentures, the magnitude of stress was greater on mucosal tissue area than that of the alveolar bone area on distal extension residual ridge area but the result was reversed on anterior residual ridge area. The displacement was always greater on mucosal tissue area than that of alveolar bone area.

  • PDF

Rehabilitation of Partial Edentulism with a Crown-type Implant-assisted Removable Partial Denture through Guided Implant Surgery: A Case Report with a 12-month Follow-up

  • Jun, Ji Hoon;Oh, Kyung Chul;Li, Jiayi;Moon, Hong Seok
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.75-83
    • /
    • 2022
  • Crown-type implant-assisted removable partial dentures (CIRPDs) can be a feasible treatment option for partially edentulous patients. Here we report a case with remaining unilateral mandibular teeth. Two implants were placed in the posterior portion of the mandible using a surgical guide, and a distal-extension removable partial denture with implant-supported surveyed crowns was fabricated. After 12 months, both the abutment teeth and implants were in good condition. The treatment outcomes were satisfactory in terms of masticatory function and esthetics. The advantages of CIRPDs and considerations for obtaining successful clinical outcomes with these dentures are also discussed.