디젤발전 자켓냉각시스템 열성능 향상 연구 (Performance Research of a Jacket Cooling Water System in a Diesel Electric Generation)

  • 이재근;문전수;윤석원;박필양
    • 한국수소및신에너지학회논문집
    • /
    • 제20권6호
    • /
    • pp.534-539
    • /
    • 2009
  • One of the most efficient techniques improving the heat transfer performance of a diesel electric generation is a corrosion control in jacket cooling water system. The environmental parameters most affecting corrosion are dissolved salt concentration, temperature, and pH of cooling water. No corrosion occurs in carbon steel probe at pH 11 in normal operating condition of diesel electric generation cooling water. pH control agent in this study is trisodium phosphate. pH control appears to be the most convenient way to enhance the thermal performance of a diesel electric generation.

군산 연안 해역에서의 부영양화 제어에 관한 연구 (A study on Eutrophication control in coastal area of Gunsan)

  • 김종구;정태주
    • 한국환경과학회지
    • /
    • 제12권9호
    • /
    • pp.957-966
    • /
    • 2003
  • Gunsan coastal area is one of region increasing pollution problems. To improve water quality, the reduction of these nutrients loads should be indispensible. In this study, the three-dimensional numerical hydrodynamic and ecosystem model were applied to analyze the processes affecting the eutrophication. In field survey, the average concentrations of dissolved inorganic nitrogen (DIN) and dissolved inorganic phosphorus(DIP) at surface waters were found to be 0.43mg/$\ell$ and 0.03mg/$\ell$ respectively, which were exceeding second grade of water quality criteria. In hydrodynamic modelling, the comparison between the simulated and observed tidal ellipses showed fairly good agreement. The ecosystem model was calibrated with the observed data in study area. The simulated results of DIN were fairly good coincided with the observed values within relative error of 32.39%, correlation coefficient(r) of 0.99. In the case of DIP, the simulated results were fairly good coincided with the observed values within relative error of 24.26%, correlation coefficient(r) of 0.82. The simulations of DIN and DIP concentrations using ecosystem model were performed under the conditions of 20∼80% reductions for pollutant loading. At simulation results, concentration of DIN and DIP were reduced to 20∼80% and under 10% in case of the 80% reduction of pollutant loading, respectively.

Monitoring bridge scour using dissolved oxygen probes

  • Azhari, Faezeh;Scheel, Peter J.;Loh, Kenneth J.
    • Structural Monitoring and Maintenance
    • /
    • 제2권2호
    • /
    • pp.145-164
    • /
    • 2015
  • Bridge scour is the predominant cause of overwater bridge failures in North America and around the world. Several sensing systems have been developed over the years to detect the extent of scour so that preventative actions can be performed in a timely manner. These sensing systems have drawbacks, such as signal inaccuracy and discontinuity, installation difficulty, and high cost. Therefore, attempts to develop more efficient monitoring schemes continue. In this study, the viability of using optical dissolved oxygen (DO) probes for monitoring scour depths was explored. DO levels are very low in streambed sediments, as compared to the standard level of oxygen in flowing water. Therefore, scour depths can be determined by installing sensors to monitor DO levels at various depths along the buried length of a bridge pier or abutment. The measured DO is negligible when a sensor is buried but would increase significantly once scour occurs and exposes the sensor to flowing water. A set of experiments was conducted in which four dissolved oxygen probes were embedded at different soil depths in the vicinity of a mock bridge pier inside a laboratory flume simulating scour conditions. The results confirmed that DO levels jumped drastically when sensors became exposed during scour hole evolution, thereby providing discrete measurements of the maximum scour depth. Moreover, the DO probes could detect any subsequent refilling of the scour hole through the deposition of sediments. The effect of soil permeability on the sensing response time was also investigated.

Ozoflotation 공정의 정수처리 적용에 관한 연구 (A Study on the Ozoflotation Process for Drinking Water Treatment)

  • 강태희;오병수;이훈;변규식;권순범;손병용;안효원;강준원
    • 한국물환경학회지
    • /
    • 제21권5호
    • /
    • pp.528-534
    • /
    • 2005
  • Ozone, a powerful oxidant, is widely used to remove microorganisms, pesticides, taste and odor compounds effectively. Dissolved air flotation (OAF) has been known as an economical process for treating algae and low turbid water quality. An ozoflotation system, combining ozone and OAF processes, has a merit which can operate the ozonation and flotation process simultaneously in a single compartment. This study investigated the application of the ozoflotation process for advanced water treatment by carrying out the pilot-plant experiment. During the test, ozone microbubbles were generated through a OAF pump and many kinds of parameters were evaluated under several conditions, such as raw water flow rate and ozone dose. As a result of the test, the optimum operating conditions of ozoflotation were decided to be 1.2 mg/L ozone dose and about 34 minute Hydraulic retention time (HRT). Finally, it could be demonstrated that the ozoflotation system can effectively improve the drinking water quality.

토양/수체 내 양이온 계면활성제와 용존유기물이 소수성유기화합물의 분포에 미치는 영향 연구 (Effect of Dissolved Organic Matter and Cationic Surfactant on the Distribution of HOC in soil/water system)

  • 문정원;박재우
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 추계학술대회
    • /
    • pp.281-285
    • /
    • 2000
  • The effect of the presence of dissolved organic matters(DOM) on the binding of phenanthrene to cetylpyridinium chloride(CPC) coated sand was investigated. The distribution coefficient of phenanthrene increased with increase of sufactant coverage, and decreased with the presence of dissolved organic matters except for the 1.600mg/g coverage case. Both Aldrich humic acid and extracted dissolved organic matter showed the similar tendency. For the quantification of the overall distribution coefficient, this study presented mass distribution model and estimated the sorption equilibrium coefficients of hydrophobic organic compounds(HOCs) in multi system. The suggested model combined a series of sorption equilibrium relationships including the adsorption of DOMs on sorbents, the binding between HOCs and DOMs, and the sorption of HOCs on sorbents with or without DOMs.

  • PDF

광양만의 용존성 및 입자성 미량금속의 분포특성 (Distribution characteristics of dissolved and particulate trace metals in Kwangyang Bay, Korea)

  • 진용현;김경태;김석현;양동범;홍기훈;이광우
    • 한국물환경학회지
    • /
    • 제16권4호
    • /
    • pp.421-430
    • /
    • 2000
  • To study the distribution and the behavior of trace metals in Kwangyang Bay, surface water samples were collected four times from August 1997 to May 1998 and were analyzed for trace metals (Cd, Co, Cu, Fe, Ni, Pb, Zn) by Atomic Absorption Spectrometer and Inductively Coupled Plasma Mass Spectrometer. Dissolved Co and Fe concentrations were comparatively high near the Seomjin River mouth. Particulate trace metal contents were relatively high near the Sueochun River mouth and near the Yeochun industrial complex. Distribution coefficients ($K_d$; $Lkg^1$) between dissolved and particulate phases of Fe, Pb, Co, Zn, Ni, Cu and Cd were $1.67{\times}10^8$, $1.37{\times}10^6$, $7.25{\times}10^5$, $4.43{\times}10^5$, $1.39{\times}10^5$, $9.1{\times}10^4$ and $1.8{\times}10^4$, respectively. In Kwangyang Bay, particulate trace-metal concentrations were as high as dissolved ones and showed seasonal and geographic variations.

  • PDF

탈산소제 차단 수처리에 의한 배열회수보일러 저압증기발생기 연결배관내의 유동가속부식 저감 (Reduction of the Flow Accelerated Corrosion within Low Pressure Evaporator Connection Pipe by Interception of Hydrazine for Water Treatment)

  • 손병관;이재헌
    • 플랜트 저널
    • /
    • 제9권4호
    • /
    • pp.26-30
    • /
    • 2013
  • 유동가속부식에 의해 배관이 파손된 500 MW급 A 복합발전소 배열회수보일러 저압증기발생기 배관을 모델로 삼아 배관급수 내의 용존산소 부족이 유동가속부식의 주요 원인임을 도출하고 용존산소를 증가시키기 위해 적용된 하이드라이진 차단 수처리에 대한 적용효과를 분석하였다. 수처리 적용 1년 후 급수의 용존산소는 0.15 ppb에서 3~5 ppb로 상승되고, 산화환원전위도 -245 mV에서 170 mV로 산화성으로 상승되었다. 또한 유동가속부식에 의한 부식생성물인 철분함유량은 18.5 ppb에서 5~7 ppb로 감소되었다. 따라서 하이드라이진 차단 수처리로 급수의 용존산소가 증가되며 유동가속부식에 의한 배관의 부식생성물인 철분함유량이 감소됨을 확인하였다.

  • PDF

순산소와 Vortex Aerator를 이용한 도심하천의 수질 및 악취 관리 (Urban Streams' Water Quality and Odor Control Using Pure Oxygen and Vortex Aerator)

  • 윤다인;최미정;박성혁
    • 대한토목학회논문집
    • /
    • 제41권5호
    • /
    • pp.493-504
    • /
    • 2021
  • 와류에 의해 물과 산소의 충돌을 반복적으로 일으켜 산소를 용존시키는 Multistage Vortex Aerator를 하천 정화에 적용하였다. 본 연구의 대상 현장인 괴정천은 부산시 사하구 도심을 흘러 낙동강 하구로 연결되는데, 우천 시에는 비점 오염물질이 유입되고 평시에도 하수 슬러지가 일부 유입되어 퇴적을 반복함에 따라 하천수의 용존산소 농도가 혐기성 상태에 가까웠다. 산소농도가 최소 0.1 ppm인 하천수를 흡입하여 22 ppm 이상으로 산소를 용존시켜 분당 1 m3을 순환시켰을 때, 하천에 나타나는 수질과 악취 변화를 2개월간 모니터링하였다. 운영 결과, 용존산소가 하천 전체적으로 약간 나쁨(4)~나쁨(5)에서, 좋음(1b)~보통(3) 등급으로 개선되었고, 총인 농도는 평균 76 % 감소되었다. 복합악취는, 하천 전체가 혐기화된 측정일에 최대 84.5 % 저감을 관찰할 수 있었다.

시화호 중 다환방향족탄화수소(PAHs)의 농도와 매질별 분배 특성 (Concentration and Partitioning of Polycyclic Aromatic Hydrocarbons(PAHs) in the Lake of Sihwa)

  • 김종국;김형섭;김경심;이동수
    • 대한환경공학회지
    • /
    • 제27권7호
    • /
    • pp.690-696
    • /
    • 2005
  • 시화호를 대상으로 수계 중 다환방향족탄화수소(PAHs)의 농도와 분포특성을 조사하였다. 용존상과 입자상으로 분리된 물시료와 저질 시료를 분석한 결과 시화호의 상류인 반월지역과 하류인 시화지역의 물 시료 중 PAHs 농도는 각각 $21.9{\sim}49.6\;ng/L$, $19.4{\sim}99.7\;ng/L$로 나타났으며, $85{\sim}90%$ 정도가 용존상에 존재하였다. 또한 저질시료에서는 반월지역이 $51.7{\sim}325\;ng/g-dry$, 시화지역이 $13.4{\sim}72.3\;ng/g-dry$으로 다소 지역적 차이가 있는 것으로 나타났다. 수중 용존상은 저분자와 중간 분자량대 화합물이 주를 이루고 수중 입자상과 저질은 중간 분자량과 고분자량대 화합물이 주를 이루고 있었다. 옥탄올/물 분배계수에 대한 수중 용존상/입자상 분배계수로부터 얻어진 회귀직선의 기울기는 $0.73{\pm}0.12$로 나타났으며, 물/저질 분배계수로부터 얻어진 기울기는 $0.59{\pm}0.10$으로 나타났다. 이러한 결과로부터 저질/물 사이의 분배현상 뿐만 아니라 수중 용존/입자 상 분배 현상도 평형에 도달하고 있지 못한 것을 알 수 있었다.

양식장 배출수 수질관리를 위한 용존공기부상 공법의 운전 인자 영향 분석 (Analysis of the operating factors of dissolved air flotation (DAF) process for effluent quality improvement from aquaculture rearing tank)

  • 기재홍;김형준;이주영;한무영;강희웅
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.107-113
    • /
    • 2012
  • Pollutants in aquaculture system effluent mostly originated from solid wastes including uneaten feed and excreta of cultured species. In this research, DAF(Dissolved Air Flotation) unit is suggested as an integrated solid control unit especially as a form of IIBG(Inline Injection Bubble Generation) process in aquaculture system. Solid removal performance of DAF unit was examined under various operation and salinity conditions with turbidity and suspended solid. Solid waste removal efficiencies were found to be affected by operation conditions including saturator pressure, recycle ratio, coagulant concentration. Solid removal efficiency was higher under higher saturator pressure and recycle ratio under which condition larger number of bubbles is generated. Coagulant is thought to have important role in creating bubble-particle aggregate by showing better removal efficiency with higher concentration. However higher saline water showed less effectiveness in removing solids by DAF(IIBG). Application of DAF(IIBG) process also showed additional effect in phosphate removal and DO(Dissolved Oxygen) supply. Phosphate existed in polluted water was removed up to 46% after treatment, which is thought to attribute to aluminium phosphate precipitation. And DO concentration was found to increase over 50% of initial saturation concentration after the injection of micro-bubbles. Through experiments on solid removal from aquaculture effluent, DAF(IIBG) process is estimated to be effective solid control method. This property can help aquaculture system being installed and operated simply and effectively.