• Title/Summary/Keyword: dissolution testing

Search Result 38, Processing Time 0.022 seconds

Development of Dissolution Testing Method for Piracetam Tablets and Fenoterol Hydrobromide Tablets in Korean Pharmaceutical Codex (고시 수재 의약품 중 피라세탐 정 및 브롬화수소산페노테롤 정의 용출시험법 개발)

  • Kim, Eun-Jung;Lee, Jin-Ha;Park, Chan-Ho;Sohn, Kyung-Hee;Kim, In-Kyu;Kim, Dong-Sup;Sah, Hong-Kee;Choi, Hoo-Kyun
    • YAKHAK HOEJI
    • /
    • v.55 no.4
    • /
    • pp.324-331
    • /
    • 2011
  • Although the dissolution test can serve as an effective tool for quality control and predictor of in vivo performance, there are a number of drugs with no established dissolution specifications in Korean Pharmaceutical Codex (KPC). Among those commercially available, Piracetam Tablets and Fenoterol hydrobromide Tablets were selected to develop the dissolution testing method. The dissolution condition was determined based on the "Guidelines on Specifications of Dissolution tests for Oral dosage forms" of Korea Food & Drug Administration (KFDA). The dissolution test for Piracetam Tablets was carried out under sink condition with distilled water as dissolution medium, paddle rotation speed at 50 rpm and medium volume of 900 ml. More than 80% of its label claim was released within 30 min. In case of Fenoterol hydrobromide Tablets, distilled water was also found to be suitable to ensure sink condition. The rotation speed of 50 rpm and 900 ml of dissolution medium were used to evaluate the dissolution profile. The dissolution rate of fenoterol hydrobromide was over 90% in 15 min. The HPLC analysis methods were validated in terms of accuracy, precision, specificity, linearity, quantitation limit and range. The results suggested that the analytical methods used are simple and suitable to measure the dissolution rate of piracetam and fenoterol hydrobromide. Therefore, the analysis methods could be utilized in setting dissolution specifications of Piracetam Tablets and Fenoterol hydrobromide Tablets in the revised version of KPC.

Development of the Dissolution Tests for Nafronyl Oxalate Capsules and Tramadol Hydrochloride Capsules (수산나프로닐 캡슐 및 염산트라마돌 캡슐의 용출시험에 관한 연구)

  • Hwang, Joung-Boon;Moon, Hyun-Ju;Go, Seo-Youn;Jang, Gi-Uk;Lee, Kyu-Ha;Sohn, Kyung-Hee;Kim, In-Kyu;Cho, Dae-Hyun
    • YAKHAK HOEJI
    • /
    • v.55 no.5
    • /
    • pp.411-418
    • /
    • 2011
  • The dissolution test method and an analytical procedure by HPLC were developed and validated for nafronyl oxalate capsules and tramadol hydrochloride capsules. These drugs were not yet characterized by the dissolution specifications in the Korean Pharmaceutical Codex. So, with each reference and test drugs, we did the preliminary and standard experiments based on the Korean Pharmacopeia Guideline of dissolution testing for solid oral dosage forms. The dissolution test for nafronyl oxalate capsules was carried out under sink conditions as follows: dissolution medium phosphate buffer pH 6.8, paddle rotation speed 100 rpm and vessel volume 900 ml. More than 80% of its label amount was released within 30 min in this method. Also the dissolution test for tramadol hydrochloride capsules was carried out under sink conditions as follows: dissolution medium water, paddle rotation speed 50 rpm and vessel volume 900 ml. More than 90% of its label amount was released within 15 min in this method. The dissolution samples were analyzed with a validated HPLC analytical procedure. The analytical methodology showed acceptable values in terms of specificity, linearity, precision and accuracy. The dissolution test methods described above were adequate for the purpose and may be proposed as a pharmacopeial standard to assess the performance of nafronyl oxalate capsules and tramadol hydrochloride capsules. Furthermore, the outcomes of this study were expected to help create an environment where safe and high quality drugs would be distributed on the domestic market making contributions to advancing public health.

Development of the Dissolution Test for Dobesilate Calcium Tablets and Acepifylline Tablets (도베실산칼슘 정 및 아세피필린 정의 용출시험법 개발)

  • Park, Chan-Ho;Lee, Jin-Ha;Kim, Eun-Jung;Sohn, Kyung-Hee;Kim, Young-Ok;Kim, Dong-Sup;Song, Young-Me;Sah, Hong-Kee;Choi, Hoo-Kyun
    • YAKHAK HOEJI
    • /
    • v.55 no.2
    • /
    • pp.131-137
    • /
    • 2011
  • The dissolution test method and an analytical procedure by HPLC were developed and validated for dobesilate calcium tablets and acepifylline tablets. These drugs were not yet characterized by the dissolution specifications in Korean Pharmaceutical Codex. So, with each reference and test drugs, we did the preliminary and standard experiments based on the Korean Pharmacopeia Guideline of dissolution testing for solid oral dosage forms. The dissolution test for dobesilate calcium tablets was carried out under sink conditions as following: dissolution medium water, paddle rotation speed 50 rpm and vessel volume 900 ml. More than 90% of its label amount was released within 30 min in this method. Also the dissolution test for acepifylline tablets was carried out under sink conditions as follows: dissolution medium water, paddle rotation speed 100 rpm and vessel volume 900 ml. More than 90% of its label amount was released within 45 min in this method. The dissolution samples were analyzed with a precise and accurate HPLC method. The developed dissolution test showed specificity, linearity, precision and accuracy within the acceptable range. The dissolution testing method described above was adequate for the purpose and may be proposed as a pharmacopeial standard to assess the performance of dobesilate calcium tablets and acepifylline tablets.

Determination of Forward Dissolution Rate of Glass by a Single-Pass Flow-Through Test (Single-Pass Flow-Through Test방법에 의한 유리의 정용해율 측정)

  • Kim Seung-Soo;Chun Kwan-Sik;Choi Jong-Won;Kim Sung-Ki;Hahn Pil-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.335-340
    • /
    • 2005
  • The forward dissolution rate of a borosilicate waste glass was determined as an interlaboratory study(ILS) testing program for the evaluation of precision in the measurement of the dissolution rate or a waste glass using a single-pass flow-through(SPFT) test, whose conducting practice has been written for standardization through American Society for Testing and Materials (ASTM). A simulated low-activity waste glass powder with a size of 100/200 mesh was dissolved by lithium buffer solution (pH=10) at 70? under Ar atmosphere. By plotting the dissolution rates as a function of silicon and boron concentration in eluate, the forward dissolution rate of the glass was obtained as about $2.7\times10^{-5}g{\cdot}m{\cdot}s^{-1}$ in our laboratory.

  • PDF

Development of the Dissolution Test for Viquidil Hydrochloride Capsules and Alibendol Tablets (염산비퀴딜 캡슐 및 알리벤돌 정의 용출시험에 관한 연구)

  • Hwang, Joung-Boon;Koo, Eun-Joo;Go, Seu-Youn;Cho, Kyung-Chul;Moon, Hyun-Ju;Cho, Soo-Yeul;Kang, Chan-Soon;Shon, Yeo-Won;Kim, Young-Ok;Sohn, Kyung-Hee;Cho, Dae-Hyun
    • YAKHAK HOEJI
    • /
    • v.54 no.5
    • /
    • pp.348-353
    • /
    • 2010
  • The dissolution test method and an analytical procedure by HPLC were developed and validated for viquidil hydrochloride capsules and alibendol tablets. These drugs were not yet characterized by the dissolution specifications in Korean Pharmaceutical Codex. So, with each reference and test drugs, we did the preliminary and standard experiments based on the Korean Pharmacopeia Guideline of dissolution testing for solid oral dosage forms. The dissolution test for viquidil hydrochloride capsules was carried out under sink conditions as follows: dissolution medium water, paddle rotation speed 50 rpm and vessel volume 900 ml. More than 90% of its label amount was released within 30 min in this method. Also the dissolution test for alibendol tablets was carried out under sink conditions as follows: dissolution medium water, paddle rotation speed 100 rpm and vessel volume 900 ml. More than 90% of its label amount was released within 45 min in this method. The dissolution samples were analyzed with a precise and accurate HPLC method. The developed dissolution test showed specificity, linearity, precision and accuracy within the acceptable range. The dissolution testing method described above was adequate for the purpose and may be proposed as a pharmacopeial standard to assess the performance of viquidil hydrochloride capsules and alibendol tablets.

In vitro/In vivo Correlation of Sustained Release Diltiazem (딜티아젬서방정을 이용한 In vitro/In vivo 상관성)

  • Choi, Myoeng-Sin;Kang, Chan-Soon;Choi, Bo-Kyung;Hong, Chong-Hui;Kim, Kil-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.4
    • /
    • pp.321-325
    • /
    • 2002
  • IVIVC (In vitro/in vivo correlation) is useful for predicting in vivo results from in vitro data. The aim of this study was to develop IVIVC of sustained release diltiazem. For this purpose, three types of diltiazem tablets with different in vitro dissolution rates were prepared. An in vitro dissolution testing method comprising of paddle apparatus, 50 rpm, water as dissolution medium was developed. Under these condition, we demonstrated that AUCinf could be predicted by evaluating $d_{70%}$ (time dissolved 70%) in vitro since the in vivo AUCinf was correlated with the in vitro $d_{70%}$ (r=-0.9981).

Dissolution Resistance Property of Modified Asphalt Waterproofing Sheet Coated with Polyamide Film by SEM-EDX Analysis (폴리아마이드 필름이 코팅된 개량 아스팔트 방수시트의 SEM-EDX 분석을 통한 유기용제 저항성 확인)

  • An, Ki-Won;Yoo, Jae-Yong;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.5
    • /
    • pp.437-444
    • /
    • 2017
  • In the composite waterproofing method in which a polyurethane coating waterproofing material is applied on the modified asphalt waterproofing sheet, the organic solvent is diluted in the coating waterproofing material in order to improve the workability. However, since the organic solvent is not volatilized before the curing of the polyurethane coating waterproofing material, the organic solvent causes dissolution of asphalt layer, thereby causing oil leakage. As a result, a polyamide film having a high dissolution resistance property was laminated on modified asphalt sheet, and through testing the dissolution resistance was visually confirmed and quantitative analysis of the polyamide film by SEM-EDX analysis was also used to confirmed the dissolution resistance of the polyamide film.

Establishment of Dissolution Specifications for Octylonium Bromide Tablets and Pinaverium Bromide Tablets (브롬화옥틸로늄 정과 브롬화피나베륨 정의 용출규격 설정)

  • Lee, Ryun-Kyung;Lee, Yoon-Ae;Shim, Jee-Youn;Kim, Min-A;Sohn, Kyung-Hee;Park, Hye-Rim;Kim, Hee-Sung;Song, Young-Mi;Lee, Su-Jung;Sah, Hong-Kee;Choi, Hoo-Kyun;Kim, Young-Ok;Kim, Dong-Sup;Cho, Tae-Yong
    • YAKHAK HOEJI
    • /
    • v.55 no.5
    • /
    • pp.419-425
    • /
    • 2011
  • To secure the good quality of pharmaceutical products, dissolution specifications for Octylonium bromide tablets and Pinaverium bromide tablets are needed to be established, which are enrolled in KPC (Korea Pharmaceutical Codex) with having no appropriate specifications. For establishing dissolution specifications, a number of experiments based on the "Guideline of Dissolution Testing for Solide Oral Dosage Forms" were performed. The results of this study will be used for revising KPC and it is expected to contribute to the incessant production of quality ensured drugs.

Development of Automated Diffusion Cell for Determining In Vitro Drug Release from Transdermal Device (경피흡수제형의 in vitro 약물방출실험을 위한 연속확산 장치의 개발)

  • Byun, Young-Rho;Choi, Young-Kweon;Jeong, Seo-Young;Kim, Young-Ha
    • YAKHAK HOEJI
    • /
    • v.34 no.3
    • /
    • pp.161-165
    • /
    • 1990
  • An automated, simple, and reliable method was developed for determining in vitro drug release rate from transdermal delivery dosage forms. The patch is held in position in the heating block by sandwiching it between the middle plate and the bottom plate of diffusion cell. The dissolution profile of the commercially available transdermal scopolamine patch was determined over a 72-h period, and the results were compared with those obtained with other methods; paddle-over-disk method, reciprocating method, and diffusion cell method. It was demonstrated that the flow-through method is equivalent in terms of release rate profile and accumulated released drug amount over the lifetime of the dosage form tested. Also this method is simple, reliable and reproducible. Therefore, this technique can be used in a quality control for assuring product uniformity.

  • PDF

Carbohydrate-electrolyte drinks exhibit risks for human enamel surface loss

  • de Melo, Mary Anne Sampaio;Passos, Vanara Florencio;Lima, Juliana Paiva Marques;Santiago, Sergio Lima;Rodrigues, Lidiany Karla Azevedo
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.4
    • /
    • pp.246-254
    • /
    • 2016
  • Objectives: The aim of this investigation was to give insights into the impact of carbohydrate-electrolyte drinks on the likely capacity of enamel surface dissolution and the influence of human saliva exposure as a biological protective factor. Materials and Methods: The pH, titratable acidity (TA) to pH 7.0, and buffer capacity (${\beta}$) of common beverages ingested by patients under physical activity were analyzed. Then, we randomly distributed 50 specimens of human enamel into 5 groups. Processed and natural coconut water served as controls for testing three carbohydrate-electrolyte drinks. In all specimens, we measured surface microhardness (Knoop hardness numbers) and enamel loss (profilometry, ${\mu}m$) for baseline and after simulated intake cycling exposure model. We also prepared areas of specimens to be exposed to human saliva overnight prior to the simulated intake cycling exposure. The cycles were performed by alternated immersions in beverages and artificial saliva. ANOVA two-way and Tukey HDS tests were used. Results: The range of pH, TA, and ${\beta}$ were 2.85 - 4.81, 8.33 - 46.66 mM/L and 3.48 - $10.25mM/L{\times}pH$, respectively. The highest capacity of enamel surface dissolution was found for commercially available sports drinks for all variables. Single time human saliva exposure failed to significantly promote protective effect for the acidic attack of beverages. Conclusions: In this study, carbohydrate-electrolyte drinks usually consumed during endurance training may have a greater capacity of dissolution of enamel surface depending on their physicochemical proprieties associated with pH and titratable acidity.