• 제목/요약/키워드: display panel

검색결과 1,760건 처리시간 0.026초

AC PDP의 온도에 따른 방전 특성 연구 (A Study on the Temperature-Dependent Discharge Characteristics in Alternating Current Plasma Display Panel)

  • 이석현;김지용
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.577-582
    • /
    • 2007
  • The plasma display panel is an image expression display using gas discharge plasma. However, gas discharge characteristics vary with temperature as gas discharge is sensitive to temperature. The discharge time lag extends a lot in low temperature and it is known as the cause which hinders high speed addressing which is essential for the size enlargement of the panel. Accordingly this research aims at identifying the temperature-dependent discharge characteristic. The lower temperature becomes, the longer addressing discharge time lag becomes. Particularly the statistical time lag extends much in low temperature. The increasing of electric field shortens discharge time lag in low temperature. Also, when priming particles are sufficiently supplied, stable discharge can be performed regardless of the influence of temperature.

AC 플라즈마 디스플레이패널의 방전개시전압에 모델과 실험의 비교에 관한 연구 (Comparision Study Between Modeling and Experiment of the Breakdown Voltage for AC Plasma Display Panel)

  • 박장식
    • 한국전기전자재료학회논문지
    • /
    • 제13권12호
    • /
    • pp.1039-1044
    • /
    • 2000
  • Breakdown voltage model and expertiments are compared for discharge cells of AC plasma display panel. In the model, discharge paths are assumed to be initial electric field lines and the one-dimensional continuity equation is applied to the charged particle transport at each field line. The comparisons are performed in the wide range of gas pressure (50-600torr), Xe partial pressure over total pressure (1-6%), sustain electrode gap(100-1000$\mu\textrm{m}$), wall height(130, 300$\mu\textrm{m}$), and voltage pulse width(2-6${\mu}$s). The presented breakdown voltage model well agree with experiments in the above wide range. The increase of breakdown voltage with the decrease of the width(L) of protruding electrode is also described by the model.

  • PDF

Single-Scan Plasma Display Panel(PDP)를 위한 고속 어드레스 에너지 회수 기법 (A High Speed Address Recovery Technique for Single-Scan Plasma Display Panel(PDP))

  • 이준영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.239-242
    • /
    • 2005
  • A high speed address recovery technique for AC plasma display Panel(PDP) is proposed. By removing the GND switching operation, the recovery speed can be increased and switching loss due to GND switch also becomes to be reduced. The proposed method is able to perform load-adaptive operation by controlling the voltage level of energy recovery capacitor, which prevents increasing inefficient power consumption caused by circuit loss during recovery operation. Thus, the technique shows the minimum address power consumption according to various displayed images, different from Prior methods operating in fixed mode regardless of images. Test results with 50" HD single-scan PDP(resolution = 1366$\times$768) show that less than 350ns of recovery time is successfully accomplished and about 54% of the maximum power consumption can be reduced, tracing minimum power consumption curves.

  • PDF

FPD용 박막 두께 자동 측정을 위한 지능화 알고리즘 (Intelligent algorithm for automatical measuring FPD thickness)

  • 문찬우;최우경;김성현;김용민;전홍태
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2006년도 춘계학술대회 학술발표 논문집 제16권 제1호
    • /
    • pp.231-234
    • /
    • 2006
  • 과거 디스플레이 장치로서 사용되던 CRT를 대신하여, 상대적으로 두께가 않고 가벼운 영상장치인 평판 디스플레이(Flat Panel Display, FPD)의 사용이 급증하고 있다. 이렇게 평판표시장치(Flat Panel Display) 산업의 폭발적인 성장과 함께 새로운 공정개발을 통해 짧은 시간에 더 많은 양을 생산하고, 불량률을 낮추는가에 생산업체의 사활이 달려있다. 본 논문은 FPD 공정에서 품질을 결정하는 여러 요인 가운데 비중이 큰 박막 두께의 제어를 지능화 알고리즘을 통해 해결하고자 한다. 이는 불필요한 과정을 줄여 공정경비를 절감 및 소요시간을 단축하고, 정밀하게 두께를 측정하는 것을 가능하게 한다. 마지막으로, 제안한 알고리즘을 광 간섭 두께 측정기를 통해 얻은 실제 값을 가지고 시료의 두께를 측정한다.

  • PDF

Comparative study on one and two-path single energy recovery circuit for plasma display panel (PDP)

  • Yi, Kang-Hyun;Choi, Seong-Wook;Moon, Gun-Woo;Park, Jung-Pil;Jung, Nam-Sung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.256-259
    • /
    • 2006
  • Comparison of one two-path single energy recovery circuit for plasma display panel (PDP) is shown in this paper. A single energy recovery circuit (SERC) is proposed to reduce cost for manufacturing PDP and there are two ways, one and two-path, in driving this circuit. Compared with one-path SERC, there are low power consumption, low surge current and high performance in two-path SERC. The results will be shown with 42-inch HD panel.

  • PDF

Nano-porous $Al_2O_3$ used as a protecting layer of AC Plasma Display Panel

  • Park, Sung-Yun;Hong, Sang-Min;Shin, Bhum-Jae;Cho, Jin-Hoon;Kim, Seong-Su;Park, Sung-Jin;Lee, Kyu-Wang;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.359-361
    • /
    • 2003
  • Nano-porous alumina was investigated as a protecting layer in an AC Plasma Display Panel. A 2 ${\mu}m$ thick nano-porous $Al_2O_3$ layer inserted with MgO was formed on the dielectric layer instead of the conventional 500 nm-thick MgO thin film. Both nano-porous $Al_2O_3$layer and inserted MgO were prepared by wet process. The luminance and luminous efficiency of 3-inch test panel adopting nano-porous $Al_2O_3$ was higher than that of the conventional PDP.

  • PDF

플라즈마 디스플레이 패널을 위한 레이저 직접 패터닝 (Laser-Direct Patterning for Plasma Display Panel)

  • 안민영;이경철;이홍규;이천
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.99-102
    • /
    • 1999
  • A mixture which was made from organic gel, glass powder and ceramic powder was masklessly etched for fabrication of barrier rib of PDP(Plasma Display Panel) by focused Ar$^{+}$ laser( λ =514 nm) and Nd:YAG(λ =532, 266 nm) laser irradiation at the atmosphere. The depth of the etched grooves increases with increasing a laser fluence and decreasing a scan speed. Using second harmonic of Nd:YAG laser, the threshold laser fluence was 6.5 mJ/$\textrm{cm}^2$ for the sample of PDP barrier rib softened at 12$0^{\circ}C$. The thickness of 130 ${\mu}{\textrm}{m}$ of the sample on the glass was clearly removed without any damage on the glass substrate by fluence of 19.5 J/$\textrm{cm}^2$....

  • PDF

Plasma Display Panel 제조장치 기술 동향 (A technical trend of manufacture apparatus of Plasma Display Panel)

  • 최영욱;김광훈;이홍식;임근희;강도현;김용주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2150-2152
    • /
    • 2000
  • In this report, a technical trend of manufacture apparatus of PDP (Plasma Display Panel) was described. Though the manufacture process of PDP was not yet established, a big progress was achieved by much maker recently. Final target for PDP of much maker is focused on the cost down of PDP.

  • PDF

Single-Scan Plasma Display Panel(PDP)를 위한 고속 어드레스 에너지 회수 기법 (A High Speed Address Recovery Technique for Single-Scan Plasma Display Panel(PDP))

  • 이준용
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권9호
    • /
    • pp.450-453
    • /
    • 2005
  • A high speed address recovery technique for AC plasma display panel(PDP) is proposed. Replacing GND switch by clamping diode. the recovery speed can be increased by saving GND hold-time and switching loss due to GND switch also becomes also be reduced. The proposed method is able to perform load-adaptive operation by controlling the voltage level of energy recovery capacitor, which prevents increasing inefficient power consumption caused by circuit loss during recovery operation. Test results with 50' HD single-scan PDP(resolution = 1366$\times$768) show that less than 3sons of recovery time is successfully accomplished and about$54\%$ of the maximum power consumption can be reduced, tracing minimum power consumption curves.

공기부상 FPD 이송장치에서 다공질판과 글래스 사이의 공기유동 해석 (Air Fluid Analysis between Porous PE-Plate and Glass in Air-Floating FPD Conveyor System)

  • 노태정;손태영
    • 한국산학기술학회논문지
    • /
    • 제9권4호
    • /
    • pp.878-885
    • /
    • 2008
  • 최근에 많은 수요와 각광을 받고 있는 디스플레이 장치에서 CRT는 곡면이며 무겁고 큰 부피 때문에 LCD, PDP, OLED와 같은 평판디스플레이(FPD)로 대체되고 있다. FPD는 $0.6\sim0.8mm$ 두께의 대면적 글래스에 여러 공정을 거친 후에 최종 제품 규격으로 절단하여 제작하기 때문에 글래스의 면적이 크면 클수록 FPD의 생산성이 높다는 밀접한 관계를 갖는다. 따라서 FPD 제조 업계에서는 글래스 면적을 증가시키기 위하여 노력하고 있으며, 예를 들면, 현재 8세대 LCD인 경우 약 $2,200mm\times2,600mm$의 면적을 가진다. 이러한 글래스를 이송하는 대표적인 장치로서 공기부상 컨베어시스템은 압축공기를 이용해서 FPD용 대면적 글래스 등을 약 $0.3\sim0.5mm$ 정도 부상시켜 비접촉으로 이송할 수 있는 장치이다. 이 때 글래스와 다공질판 표면 사이의 공기 유동이 모델링되고 해석되며, 이것으로부터 글래스의 공기부양 조건이 예측될 수 있다. 글래스를 이송시 전기공급 중단에 의하여 압축공기가 공급되지 않아 부상판과 접촉이 발생하였을 때, 자기윤활 특성을 가진 다공질판 위의 글래스는 1mm 홀을 많이 가진 사각덕트 부상판 위의 글래스와 조사, 비교된다.