• Title/Summary/Keyword: dispersive

Search Result 1,835, Processing Time 0.031 seconds

Synthesis, Structure and Characterization of Nd2XCd2-3XSiO4 (0.01≤X≤0.21) Solid-Solutions (Nd2XCd2-3XSiO4 (0.01≤X≤0.21) 고용체의 합성과 구조 규명)

  • Ramesh, S.;Das, B.B.
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.3
    • /
    • pp.502-508
    • /
    • 2011
  • Synthesis of $Nd_{2x}Cd_{2-3x}SiO_4$ ($0.01{\leq}x{\leq}0.21$) [S1-S3: x=0.01, 0.11 and 0.21] solid solutions were prepared by solgel method. Powder x-ray diffraction (XRD) results show monoclinic unit cell with space group P21/m. The average crystallite sizes are found to be 20 to 45 nm. The Scanning Electron Microcopy (SEM) images show morphology of the sample is in globular nature. The energy dispersive analysis of x-rays (EDX) and X-ray mapping results confirmed that all the constituent elements of the composites were present and that were distributed in uniformly. The optical absorption band at ~750 nm was due to $^4I_{9/2}{\rightarrow}^4F_{7/2}+^4S_{3/2}$ transition optically active $Nd^{3+}$ ions. Electron Paramagnetic Resonance (EPR) lineshapes of S1-S3 at 10, 40, 77 and 300 K show a broad unresolved isotropic lineshapes were observed due to rapid spin lattice relaxation of $Nd^{3+}$.

Sol-Gel Synthesis, Crystal Structure, Magnetic and Optical Properties in ZnCo2O3 Oxide

  • Das, Bidhu Bhusan;Barman, Bittesh
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.6
    • /
    • pp.453-458
    • /
    • 2019
  • Synthesis of ZnCo2O3 oxide is performed by sol-gel method via nitrate-citrate route. Powder X-ray diffraction (XRD) study shows monoclinic unit cell having lattice parameters: a = 5.721(1) Å, b = 8.073(2) Å, c = 5.670(1) Å, β = 93.221(8)°, space group P2/m and Z = 4. Average crystallite sizes determined by Scherrer equation are the range ~14-32 nm, whereas SEM micrographs show nano-micro meter size particles formed in ZnCo2O3. Endothermic peak at ~798 K in the Differential scanning calorimetric (DSC) trace without weight loss could be due to structural transformation and the endothermic peak ~1143 K with weight loss is due to reversible loss of O2 in air atmosphere. Energy Dispersive X-ray (EDX) analysis profile shows the presence of elements Zn, Co and O which indicates the purity of the sample. Magnetic measurements in the range of +12 kOe to -12 kOe at 10 K, 77 K, 120 K and at 300 K by PPMS-II Physical Property Measurement System (PPMS) shows hysteresis loops having very low values of the coercivity and retentivity which indicates the weakly ferromagnetic nature of the oxide. Observed X-band EPR isotropic lineshapes at 300 K and 77 K show positive g-shift at giso ~2.230 and giso ~2.217, respectively which is in agreement with the presence of paramagnetic site Co2+(3d7) in the oxide. DC conductivity value of 2.875 ×10-8 S/cm indicates very weakly semiconducting nature of ZnCo2O3 at 300 K. DRS absorption bands ~357 nm, ~572 nm, ~619 nm and ~654 nm are due to the d-d transitions 4T1g(4F)→2Eg(2G), 4T1g(4F)→4T1g(4P), 4T1g(4F)→4A2g(4F), 4T1g(4F)→4T2g(4F), respectively in octahedral ligand field around Co2+ ions. Direct band gap energy, Eg~ 1.5 eV in the oxide is obtained by extrapolating the linear part of the Tauc plot to the energy axis indicates fairly strong semiconducting nature of ZnCo2O3.

The Performance Comparison of MMA and S-MMA Adaptive Equalization Algorithm for QAM Signal (QAM 신호에대한 MMA와 S-MMA 적응 등화 알고리즘의 성능 비교)

  • Kang, Dae-Soo;Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.19-26
    • /
    • 2013
  • This paper deals with the performance comparison of blind adaptive equalization algorithm, the MMA and S-MMA, that is used for compensation of the amplitude and phase distortion simultaneously which occurs in the time dispersive channel. The present CMA algorithm is possible to compensates the amplitude only, but not in phase, so it needs to the another additional circuit for compensating the phase. In order to overcoming the abovemensioned shorthand, the improved cost function is applied to the MMA algorithm. In MMA algorithm, the error is consists of the dispersion constant only, but in S-MMA, the error is consists of the dispersion constant considering the output of decision device (sliced symbol) in order to updating the tap coefficients. By using the two kind error signal, the adaptive equalization algorithm has different performance. In this paper, we compare to the adaptive equalization algorithm performance by using the recovered constellation, residual isi, MD (Maximum Distortion) and SER as a index when the transmitting signal is 16 and 64-QAM and then passing through the same communication channel. As a result of simulation, the S-MMA can improving the Roburstness in SER performance compared to the MMA in the high order QAM signal.

The Performance Analysis of CCA Adaptive Equalization Algorithm for 16-QAM Signal (16-QAM 신호에 대한 CCA 적응 등화 알고리즘 성능 분석)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.27-34
    • /
    • 2013
  • This paper deals with the performance anlysis of CCA adaptive equalization algorithm, that is used for reduction of intersymbol interference at the receiving side which occurs in the time dispersive communication channel. Basically, this algorithm is borned for the solving phase unrecovery problem in the CMA equalizer, and the comines the concept of DDA (Decision Directed Algorithm) and RCA (Reduce Constellation Algorithm). The DDA has a stable convergence characteristics in unilevel signal, but not in the number of levels in multilevel signal such as QAM, so it has unstable problem. The RCA does not provide reliable initial convergence. And even after convergence, the equalization noise due to the steady state misadjustment exhibited by it is very high as compared to DDA. For the solving the abovemensioned point, the CCA adaptive eualization alogorithm has borned. In order to performance analysis of CCA algorithm, the recovered signal constellation that is the output of the equalizer, the convergence characteristic by the residual isi and MD (maximum distortion), the SER characteristic are used by computer simulation and it was compared with the DDA, RCA respectively. As a result of simulation, the DDA has superior performance than other algoithm, but it has a convergence unguarantee and unstability in the multilevel signal. In order to solving this problem, the CCA has more good performance than RCA in every performance index.

New fabrication of CIGS crystals growth by a HVT method (새로운 HVT 성장방법을 이용한 CIGS 결정성장)

  • Lee, Gang-Seok;Jeon, Hun-Soo;Lee, Ah-Reum;Jung, Se-Gyo;Bae, Seon-Min;Jo, Dong-Wan;Ok, Jin-Eun;Kim, Kyung-Hwa;Yang, Min;Yi, Sam-Nyeong;Ahn, Hyung-Soo;Bae, Jong-Seong;Ha, Hong-Ju
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.3
    • /
    • pp.107-112
    • /
    • 2010
  • The Cu$(In_{1-x}Ga_x)Se_2$ is the absorber material for thin film solar cell with high absorption coefficient of $1{\times}10^5cm^{-1}$. In the case of CIGS, the movable energy band gap from $CuInSe_2$ (1.00 eV) to $CuGaSe_2$ (1.68 eV) can be acquired while controlling Ga contain ratio. Generally, the co-evaporator method have used for development and fabrication of the CIGS absorption layer. However, this method should need many steps and lengthy deposition time with high temperature. For these reasons, in this paper, a new growth method of CIGS layer was attempted to hydride vapor transport (HVT) method. The CIGS mixed-source material reacted for HCl gas in the source zone was deposited on the substrate after transporting to growth zone. c-plane $Al_2O_3$ and undoped GaN were used as substrates for growth. The characteristics of grown samples were measured from SEM and EDS.

Characterization of manganese oxide supercapacitors using carbon cloth (Carbon Cloth을 이용한 이산화망간 슈퍼커패시터 특성 연구)

  • Lee, Seung Jin;Kim, Chihoon;Ji, Taeksoo
    • Journal of Digital Contents Society
    • /
    • v.18 no.6
    • /
    • pp.1199-1205
    • /
    • 2017
  • Global energy consumption is rapidly increasing yearly due to drastic industrial advances, requiring the development of new energy storage devices. For this reason, supercapacitors with fast charge-discharge, long life cycle and high power density is getting attention, and have been considered as one of the potential energy storage systems. In this research, we developed a supercapacitor that consists of amorphous manganese oxide($MnO_2$) electrodes deposited onto carbon cloth substrates using the hydrothermal method. The Fe-doped amorphous $MnO_2$ samples were characterized by X-ray diffraction(XRD), Energy Dispersive X-ray spectroscopy(EDX), as well as scanning electron microscopy(SEM). The electrochemical analysis of the prepared samples were performed using cyclic voltammetry and galvanostatic charge-discharge measurements in 1M $Na_2SO_4$ electrolyte. The test results demonstrate that the supercapacitor based on the Fe-doped amorphous $MnO_2$ electrodes has a specific capacitance as high as 163F/g at 1A/g current density, and good cycling stability of 87.34% capacitance retention up to 1000 cycles.

High Speed and Sensitive X-ray Analysis System with Automated Aberration Correction Scanning Transmission Electron Microscope

  • Inada, Hiromi;Hirayama, Yoichi;Tamura, Keiji;Terauchi, Daisuke;Namekawa, Ryoji;Shichiji, Takeharu;Sato, Takahiro;Suzuki, Yuya;Ohtsu, Yoshihiro;Watanabe, Keitaro;Konno, Mitsuru;Tanaka, Hiroyuki;Saito, Koichiro;Shimoyama, Wataru;Nakamura, Kuniyasu;Kaji, Kazutoshi;Hashimoto, Takahito
    • Applied Microscopy
    • /
    • v.45 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • We have developed a new HD-2700 (Hitachi High-Technologies Corp., Japan) scanning transmission electron microscope (STEM) that includes an automatic aberration correction function, and a large-solid-angle energy-dispersive X-ray spectroscopy detector that enables high-resolution and sensitive analysis. For observation with atomic resolution, using spherical-aberration-corrected STEM, in order that satisfactory performance of the device can be achieved readily, and within a short time, irrespective of the operator's skill level, a spherical-aberration-correction device with an automatic aberration-correction function was developed. This automatic aberration-correction function carries out the entire correction-related process (aberration measurement, selection and correction) automatically, with automatic selection of the aberrations that require correction, and automatic measurement of the appropriate corrections.

Monitoring of Veterinary Antibiotics in Agricultural Soils using Liquid Chromatography Coupled with Tandem Mass Spectrometry (LC-MS/MS를 이용한 농경지 토양 중 항생제 모니터링)

  • Lee, Young-Jun;Choi, Jeong-Heui;Chung, Hyung Suk;Lee, Han Sol;Park, Byung-Jun;Kim, Jang-Eok;Shim, Jae-Han
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.3
    • /
    • pp.166-174
    • /
    • 2016
  • BACKGROUND: The current study developed a monitoring method of 6 veterinary antibiotics (amoxicillin, ampicillin, enrofloxacin, tetracycline, chlortetracycline, oxytetracycline) in agricultural soils using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in positive electrospray ionization mode.METHODS AND RESULTS: Sample preparation was carried out using acidic acetonitrile and citrate salts followed by purification with dispersive solid phase extraction (d-SPE). Separation on Eclipse Plus C18 column was conducted in gradient of the mobile phase, 0.1% formic acid and 5 mM ammonium formate in methanol (A) and 0.1% formic acid and 5 mM ammonium formate in distilled water (B). The linearity of the matrix-matched calibrations expressed as the coefficient of determination was good with R2≥0.9900. The limit of quantifications (LOQs) ranged from 0.5 to 10 μg/kg for all analytes. Analysis of 51 agricultural soil samples taken in the Republic of Korea revealed concentrations less than 1.9 μg/kg for enrofloxacin, 75.5 μg/kg for chlortetracycline.CONCLUSION: The method was successfully applied to monitor 6 veterinary antibiotics from 51 field incurred agricultural soil samples in 17 provincial areas throughout the Republic of Korea. The developed method was simple, easy, and versatile and can be used for monitoring various veterinary antibiotics in soil.

Exposure Assessment and Asbestosis Pulmonum among Inhabitants near Abandoned Asbestos Mines Using Deposited Dust (폐석면광산 주변 지역의 주택 침적먼지의 석면 검출과 석면폐증의 관련성)

  • Ahn, Hoki;Yang, Wonho;Hwangbo, Young;Lee, Yong Jin
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.6
    • /
    • pp.369-379
    • /
    • 2015
  • Objectives: The lack of reliable information on environmental pollution and health impacts related to asbestos contamination from abandoned mines has drawn attention to the need for a community health study. This study was performed to evaluate asbestos-related health symptoms among residents near abandoned asbestos mines located in the Chungcheong Provinces. In addition, exposure assessment for asbestos is needed although the exposure to asbestos was in the past. Methods: Past exposure to asbestos among inhabitants near abandoned asbestos mines was estimated by using surface sampling of deposited dust in indoor and outdoor residences. A total of 54 participants were divided into two groups with (34 cases) and without (20 controls) diseases related to asbestos. Surface sampling of deposited dust was carried out in indoor and outdoor residences by collecting 105 samples. Deposited dust for sampling was analyzed by polarization microscope (PLM) and scanning electron microscope?energy dispersive x-ray spectrometer (SEM-EDX) to detect asbestos. Subsequently, the elements of the deposited dust with asbestos were analyzed by SEM-EDX to assess the contribution of sources such as abandoned mines, slate and soil. Results: Among the 105 samples, asbestos was detected by PLM in 29 (27.6%) sampling points, and detected by SEM in 56 (48.6%) sampling points. Asbestos in indoor residences was detected by PLM in four sampling points, and by SEM in 12 sampling points. Asbestos detection in indoor residences may be due to ventilation between indoors and outdoors, and indicates long-term exposure. The asbestos detection rate for outdoor residences in the case group was higher than that in the control group. This can be explained as the case group having had higher exposure to asbestos, and there has been continuous exposure to asbestos in the control group as well as the case group. Conclusion: Past residential asbestos exposure may be associated with asbestosis among local residents near abandoned asbestos mines. Odds ratios were calculated for asbestos detection in outdoor residence by logistic regression analysis. Odds ratio between asbestos detection and asbestosis pulmonum was 3.36 (95% CI 0.90-12.53) (p=0.072), adjusting for age, sex, smoking status and work history with multi-variable logistic regression by PLM analysis method.

SURFACE CHARACTERISTICS AND BIOLOGICAL RESPONSES OF HYDROXYAPATITE COATING ON TITANIUM BY HYDROTHERMAL METHOD: AN IN VITRO STUDY

  • Kim, Dong-Seok;Kim, Chang-Whe;Jang, Kyung-Soo;Lim, Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.363-378
    • /
    • 2005
  • Statement of problem. Hydroxyapatite(HA) coated titanium surfaces have not yet showed the reliable osseointegration in various conditions. Purpose. This study was aimed to investigate microstructures, chemical composition, and surface roughness of the surface coated by the hydrothermal method and to evaluate the effect of hydrothermal coating on the cell attachment, as well as cell proliferation. Material and Methods. Commercially pure(c.p.) titanium discs were used as substrates. The HA coating on c.p. titanium discs by hydrothermal method was performed in 0.12M HCl solution mixed with HA(group I) and 0.1M NaOH solution mixed with HA(group II). GroupⅠ was heated at 180 $^{\circ}C$ for 24, 48, and 72 hours. GroupⅡ was heated at 180 $^{\circ}C$ for 12, 24, and 36 hours. And the treated surfaces were evaluated by Scanning electron microscopy(SEM), Energy dispersive X-ray spectroscopy(EDS), X-ray photoelectron spectroscopy(XPS), X-ray diffraction method(XRD), Confocal laser scanning microscopy(CLSM). And SEM of fibroblast and 3-(4,5- dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide(MTT) assay were used for cellular responses of the treated surfaces. Results. The color of surface changed in both groups after the hydrothermal process. SEM images showed that coating pattern was homogeneous in group II, while inhomogeneous in group I. H72 had rosette-like precipitates. The crystalline structure grew gradually in group II, according to extending treatment period. The long needle-like crystals were prominent in N36. Calcium(Ca) and phosphorus(P) were not detected in H24 and H48 in EDS. In all specimens of group II and H72, Ca was found. Ca and P were identified in all treated groups through the analysis of XPS, but they were amorphous. Surface roughness did not increase in both groups after hydrothermal treatment. The values of surface roughness were not significantly different between groups I and II. According to the SEM images of fibroblasts, cell attachments were oriented and spread well in both treated groups, while they were not in the control group. However, no substantial amount of difference was found between groups I and II. Conclusions. In this study during the hydrothermal process procedure, coating characteristics, including the HA precipitates, crystal growth, and crystalline phases, were more satisfactory in NaOH treated group than in HCl treated group. Still, the biological responses of the modified surface by this method were not fully understood for the two tested groups did not differ significantly. Therefore, more continuous research on the relationship between the surface features and cellular responses seems to be in need.