• 제목/요약/키워드: dispersed flow

검색결과 210건 처리시간 0.029초

Recycling of Suspended Particulates by Atmospheric Boundary Depth and Coastal Circulation (대기경계층과 연안순환에 의한 부유입자의 재순환)

  • Choe, Hyo
    • Journal of Environmental Science International
    • /
    • 제13권8호
    • /
    • pp.721-731
    • /
    • 2004
  • The dispersion of suspended particulates in the coastal complex terrain of mountain-inland basin (city)-sea, considering their recycling was investigated using three-dimensional non-hydrostatic numerical model and lagrangian particle model (or random walk model). Convective boundary layer under synoptic scale westerly wind is developed with a thickness of about I km over the ground in the west of the mountain, while a thickness of thermal internal boundary layer (TIBL) is only confined to less than 200m along the eastern slope of the mountain, below an easterly sea breeze circulation. At the mid of the eastern slop of the mountain, westerly wind confronts easterly sea breeze, which goes to the height of 1700 m above sea level and is finally eastward return flow toward the sea. At this time, particulates floated from the ground surface of the city to the top of TIBL go along the eastern slope of the mountain in the passage of sea breeze, being away the TIBL and reach near the top of the mountain. Then those particulates disperse eastward below the height of sea-breeze circulation and widely spread out over the coastal sea. Total suspended particulate concentration near the ground surface of the city is very low. On the other hand, nighttime radiative cooling produces a shallow nocturnal surface inversion layer (NSIL) of 200 m thickness over the inland surface, but relatively thin thickness less than 100m is found near the mountain surface. As synoptic scale westerly wind should be intensified under the association of mountain wind along the eastern slope of mountain to inland plain and further combine with land-breeze from inland plain toward sea, resulting in strong wind as internal gravity waves with a hydraulic jump motion bounding up to about 1km upper level in the atmosphere in the west of the city and becoming a eastward return flow. Simultaneously, wind near the eastern coastal side of the city was moderate. Since the downward strong wind penetrated into the city, the particulate matters floated near the top of the mountain in the day also moved down along the eastern slope of the mountain, reaching the. downtown and merging in the ground surface inside the NSIL with a maximum ground level concentration of total suspended particulates (TSP) at 0300 LST. Some of them were bounded up from the ground surface to the 1km upper level and the others were forward to the coastal sea surface, showing their dispersions from the coastal NSIL toward the propagation area of internal gravity waves. On the next day at 0600 LST and 0900 LST, the dispersed particulates into the coastal sea could return to the coastal inland area under the influence of sea breeze and the recycled particulates combine with emitted ones from the ground surface, resulting in relatively high TSP concentration. Later, they float again up to the thermal internal boundary layer, following sea breeze circulation.

Calculation of Radius of Influence and Evaluation of Applicability of Air Sparging/Soil Vapor Extraction system for the Remediation of Petroleum Contaminated Rail Site (유류로 오염된 철로지역의 지중정화를 위한 영향반경 산정과 공기주입법/토양증기추출법의 적용성 평가)

  • Cho, Chang-Hwan;Park, Joung-Ku;Kim, Yong-Deok;Seo, Chang-Il;Jin, Hai-Jin;Choi, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • 제20권1호
    • /
    • pp.1-6
    • /
    • 2015
  • The objectives of this study were to calculate the radius of influence (ROI) of well for an air-sparging (AS)/soil vapor extraction (SVE) system and to evaluate the applicability of the system applied for the remediation of the petroleum contaminated rail site. For air permeability test, three monitoring wells were installed at a location of 1.3 m, 2.3 m, 3.0 m from the extraction well. And the pressure of each monitoring well was measured by extracting air from the extraction well with the pressure and flow of $(-)2,600mmH_2O$ and $1.58m^3/min$. The ROI for an extraction well was calculated as 4.31 m. Air was injected into the injection well with the pressure and flow of $3,500mmH_2O$ and $0.6m^3/min$ to estimate the radius of influence for oxygen transfer. Oxygen concentrations of air from three monitoring wells were measured. The ROI of an injection well for oxygen transfer was calculated as 3.46 m. The 28 extraction wells and 19 injection wells were installed according to the ROI calculated. The AS/SVE system was operated eight hours a day for five months. The rail site was contaminated with the petroleum and concentrations of benzene, toluene, and xylene were over the 'Worrisome Standard' of the 'Soil Environment Conservation Act'. The contaminated area was estimated as $732m^2$ and contaminants were dispersed up to (-)3 m from the ground. During the operation period, soil samples were collected from 5 points and analyzed periodically. With the AS/SVE system operation, concentrations of benzene, toluene, and xylene were decreased from 7.5 mg/kg to 2.0 mg/kg, from 32.0 mg/kg to 23.0 mg/kg, from 35.5 mg/kg to 23.0 mg/kg, respectively. The combined AS/SVE system applied to the rail site contaminated with volatile organic compounds (VOCs) exhibited a high applicability. But the concentration of contaminants in soil were fluctuated due to the heterogeneous of soil condition. Also the effect of the remediation mechanisms was not clearly identified.

A Study on Characteristics of Precipitated Calcium Carbonate Prepared by the Nozzle Spouting Method (분사법으로 제조된 침강성 탄산칼슘 특성에 관한 연구)

  • Park, Joo-Won;Kim, Joon-Seok;Ahn, Ji-Whan;Han, Choon
    • Applied Chemistry for Engineering
    • /
    • 제17권1호
    • /
    • pp.67-72
    • /
    • 2006
  • Precipitated calcium carbonate (PCC) was prepared in a cylindrical reactor by the nozzle spouting method. The reactor was filled with $CO_2$ and $Ca(OH)_2$ suspensions were circulated through a nozzle to prepare PCC. This method has several advantages such as provision of large contact area between suspension and $CO_2$ and production of large number of nuclei in short time. By changing suspension concentrations, suspension temperature, flow rates of $CO_2$ and nozzle sizes, PCC from homogeneously dispersed $0.1{\mu}m$ to heterogeneous $0.3{\mu}m$ can be obtained. According to XRD analyses, most PCC formed was calcite with small amount of aragonite depending on the reaction conditions. Usually, the reaction proceeded at high pH and electric conductivities initially. Then, pH and electric conductivities decreased rapidly to the saturation condition. Results indicated that the specific conditions (temperature: $25^{\circ}C$, suspension concentration: 0.5 wt%, $CO_2$ flow rate: 1 L/min, nozzle size: 0.4 mm) were required to prepare uniform particle size (particle diameter: $0.1{\mu}m$) of PCC.

The Analysis of Growth Environment on Corylopsis coreana Community in Hallyeohaesang National Park (한려해상국립공원 히어리군락의 생육환경 분석)

  • Shin, Seoung-Ho;Kim, Jong-Sub;Kim, Jong-Myung;Seo, Dong-Jin;Kang, Hee-Gon;Kim, Min-Kyu;Jo, Gye-Jung;Goo, Chur-Hyun;Park, Eun-Hee
    • Journal of agriculture & life science
    • /
    • 제45권5호
    • /
    • pp.49-56
    • /
    • 2011
  • This study was conducted to provide data for the maintenance of the Corylopsis coreana community within the Hallyeohaesang National Park. Survey site of Corylopsis coreana community was located at a valley, which composed of over 60% exposed rock. As this result, much of the species was damaged or washed away due to the water flow from rainfall. The tree layers dominant species were Quercus serrata and Pinus densiflora. while the subtree layers dominant species were Corylopsis coreana, Acer pseudosieboldianum, Sapium japonicum, Chamaecyparis obtusa and Cornus kousa etc. The shrub layers dominant species were Callicarpa japonica and Smilax china etc., and herbaceous layers dominant species were Disporum smilacinum etc. Increased precipitation and rainfall days were observed from May to September in this valley during 2008~2010, which likely increased soil erosion and damage. Because water flow pattern was dispersed the Corylopsis coreana seed and the soil floor was shallow, and population of Corylopsis coreana seedlings were diminished.

Measurement of Terminal Velocity for Scatter Prevention of Powder in the Voloxidizer for Oxidation of UO$_{2}$ Pellet (UO$_{2}$ 펠릿 산화로의 분말 비산 방지를 위한 최종속도 측정)

  • Kim Young-Hwan;Yoon Ji-Sup;Jung Jae-Hoo;Jin Jae-Hyun;Hong Dong-Hee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • 제3권2호
    • /
    • pp.77-84
    • /
    • 2005
  • A voloxidizer for a hot cell demonstration, that handles spent fuels of a high radiation level in a limited space should be small and spent fuel powders should not be dispersed out of the equipment involved. In this study a density rate equation as well as the Stokes'equation has been proposed in order to obtain the theoretical terminal velocity of powders. The terminal velocity of U$_{3}$O$_{8}$ has been predicted by using the terminal velocity of SiO$_{2}$, and then determination has been the optimum air flow rate which is able to prevent powders from scattering. An equation which has shown a relationship between theoretical terminal velocities of U$_{3}$O$_{8}$ and SiO$_{2}$ has been derived with the help of the Stokes'equation, and then an experimental verification made for the theoretical Stokes' equation of SiO$_{2}$ by means of an experimental device made of acryl. The theoretical terminal velocity based on the proposed density rate equation has been verified by detecting U$_{3}$O$_{8}$ powders in a filter installed in the mock-up voloxidizer. As the results, the optimum air flow rates seem to be 20 LPM by the Stokes'equation while they are 14.5 L/min by the density rate equation. At the experiments with the mock-up voloxidizer, a trace amount of U$_{3}$O$_{8}$ seems to be detectable at the air flow rate of 14.5 L/min by the density rate equation, but U$_{3}$O$_{8}$ powders of 7$\mu$m diameter seem detectable at the air flow rate of 20 L/min by the Stokes'equation. It is revealed that 14.5 L/min is the optimum air flowe rate which is capable of preventing U$_{3}$O$_{8}$ powders from scattering in the UO$_{2}$ voloxidizer and the proposed density rate equation is proper to calculate the terminal velocity of U$_{3}$O$_{8}$ powders.

  • PDF

A Study on Chemical Compositions of Sediment and Surface Water in Nakdong River for Tracing Contaminants from Mining Activities (광해오염원 추적을 위한 낙동강 지역 퇴적물 및 하천수의 화학조성 연구)

  • Kim, Jiyun;Choi, Uikyu;Baek, Seung-Han;Choi, Hye-Bin;Lee, Jeonghoon
    • Journal of the Korean earth science society
    • /
    • 제37권4호
    • /
    • pp.211-217
    • /
    • 2016
  • There have been found mine tailings, wastes, and mining drainage scattered in the area of Nakdong River due to the improper maintenance of the abandoned mines. These contaminants can flow into rivers during the heavy rain periods in summer. Along the study area beginning Seokpo-myeon, Bonghwa-gun of Gyeongsangbuk-do untill Dosan-myeon, Andong-si, there are one hundred five mines including sixty metalliferous mines and forty-five nonmetal mines, which can adversely affect the adjacent rivers. To verify the contamination, we collected sediments, seepage water and surface water for a year both in rainy season and dry season. This study found that sediments, containing high concentrations of heavy metals caused by mining activities, are dispersed throughout the entire river basin (68 sample points with pollution index, based on the concentration of trace element, (PI) >10 among the total of 101 samples). The results of river water analysis indicated the increased concentrations of arsenic and cadmium at branches from Seungbu, Sambo, Okbang and Janggun mine, which concerns that the river water may be contaminated by mining drainage and tailing sediments. However, it is difficult to sort out the exact sources of contamination in sediments and waters only by using the chemical compositions. Thus the control of mining pollution is challenging. To prevent water from being contaminated by mining activities, we should be able to divide inflow rates from each origin of the mines. Therefore, there should be a continued study about how to trace the source of contaminants from mining activities by analyzing stable isotopes.

Liquid-Liquid Dispersion of an Immiscible Liquid Phase (n-Hexane/Water) System in a Stirred Tank (교반조에서 비혼화성 액상(n-헥산/물)계의 액-액분산)

  • Kim, Tae-Ok;Kim, Dong-Uk;Chun, Jong-Han
    • Applied Chemistry for Engineering
    • /
    • 제4권3호
    • /
    • pp.537-543
    • /
    • 1993
  • The effect of agitation on liquid-liquid dispersion was investigated in an immisible liquid phase(n-hexane/water) system. Four different types of six-bladed turbine impellers were used: a flat blade, two screen blades and a solid edged 60 mesh screen blade. We found that the extent of dispersion of organic phase and power consumption of agitator were decreased in the order of flat, solid edged, 60 mesh, and 40 mesh blades at same agitation speed. And the minimum agitation speed for complete dispersion of organic phase was increased with increasing volume fraction of organic phase. Also, mean diameter of liquid droplets of dispersed phase was decreased with increasing agitation speed and it was increased in the order of solid edged, flat, 60 mesh, and 40 mesh screen blades at same agitation speed. At complete dispersion, the minimum power consumption was not vary significantly with impeller blade types, but the solid edged screen blade impeller gave the smallest and uniform sizes of liquid droplets, and it had a good performance for liquid-liquid dispersion. In this condition, Power number was not affected by Reynolds number and it was constant in turbulent flow region, and Sauter mean diameter($d_{32}$) of liquid droplets was expressed as a function of volume fraction of organic phase(${\phi}$) and Weber number($N_{We}$) as follows: $d_{32}/D=a(1+b{\phi})N_{We}{^{-0.6}}$.

  • PDF

A Study on the Soil Contamination(Maps) Using the Handheld XRF and GIS in Abandoned Mining Areas (휴대용 XRF와 GIS를 이용한 폐광산 지역의 토양오염에 관한 연구)

  • Lee, Hyeon-Gyu;Choi, Yo-Soon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • 제17권3호
    • /
    • pp.195-206
    • /
    • 2014
  • In this study, soil contamination maps related to Cu and Pb were created at the Busan abandoned mine in Korea using a handheld X-Ray Fluorescence(XRF) and Geographic Information Systems(GIS). Hydrological analysis was performed using the Digital Elevation Model(DEM) of the study area to identify the flow directions of surface runoff where pollutants can be dispersed from the soil contamination sources. 24 locations for measuring the soil contamination related to Cu and Pb were selected by considering the result of hydrological analysis. The results measured at the 24 locations using the handheld XRF showed that the highest value of Cu contamination is 8,255ppm and that of Pb is 2,146ppm. The field investigation data were entered into ArcGIS software, and then soil contamination maps regarding Cu and Pb with a 5m grid-spacing were created after performing spatial interpolations using the ordinary kriging method. As a result, we could know that high concentrations of Cu and Pb are presented at the waste and tailings dumps around the abandoned mine openings. This study also showed that the handheld XRF and GIS can be utilized to create soil contamination maps related to Cu and Pb in the field.

Population Genetic Structure of Japanese Anchovy (Engraulis japonicus) in Korean waters Based on Mitochondrial 12S Ribosomal RNA Gene Sequences (미토콘드리아 12S 리보종 RNA 유전자배열에 의한 한국해역 멸치 개체군의 유전자 구조)

  • Kim Jin Yeong;Cho Eun Seob;Kim Woo Jin
    • Journal of Life Science
    • /
    • 제14권6호
    • /
    • pp.938-950
    • /
    • 2004
  • We used portions of mitochondrial 125 ribosomal RNA gene sequences (339 bp) to investigate the phylogenetic and population genetic characteristics of the Japanese anchovy, Engraulis japonicus, in Korean waters. A total of 35 mtDNA haplotypes were obtained from the samples collected in 3 locations (the southern area of the Yellow Sea, the western coast of Jejudo, and the eastern area of the South Sea) in Korean waters. One haplotype, AN8T103, obtained from the southern area of the Yellow Sea, was formed according to an independent phylogenetic individual in the PAUP analysis, which was separated from the others by a $0.2-4.1\%$ sequence divergence. This distinct haplotype appeared to be one that was carried by immigrants from another study area, but further study is necessary. Genetic divergence, except for AN8T103, was moderate to substantial $(0.2-3.8\%)$ and nucleotide diversity within populations was 0.015 for Yellow Sea, 0.013 for Jejudo, and 0.D15 for South Sea, respectively. The female gene flow was substantial or high (Nm=25.5-36.4), and the genetic distances between regions were not statistically significant $(P>0.01)$. These results indicated that the Japanese anchovy populations occurring in Korean waters were consisted of individuals randomly dispersed over geographic areas.

Evaluation Method for Protection Coordination of PV Systems Interconnected with Primary Feeders (태양광전원이 연계된 고압배전선로의 보호협조 평가 방안에 관한 연구)

  • Kim, Byungki;Kim, Sohee;Ryu, Kyungsang;Rho, Daeseok
    • Journal of the Korea Convergence Society
    • /
    • 제2권4호
    • /
    • pp.29-37
    • /
    • 2011
  • Dispersed generation (DG) such as wind power (WP) and Photovoltaic systems (PV) that has been promoted at the national level recently is mainly being introduced into distribution systems adjacent to consumers because it is generation on a small scale when compared to current generation. Due to its characteristics, DG can be operated by interconnection with distribution systems to present security of more stable power and efficient use of power facilities and resources. Problems on protection coordination of distribution systems by reverse flow of DG can roughly be divided into three possibilities: excess in rated breaking capacity (12.5KA) of protective devices by a fault in DG current supply, failure to operate protective devices by an apparent effect that can occur by reduction in impedance parallel circuit fault current due to interconnection of DG, and malfunction of protective devices by interconnection transformer connection type. The purpose of this study is to analyze problems in protection coordination that can occur when DG is operated by interconnection with distribution systems by conducting modeling and simulations by using theoretical symmetrical components and MATLAB/SIMULINK to present methods to improve such problems.