• Title/Summary/Keyword: dispensing error

Search Result 15, Processing Time 0.04 seconds

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF

The Study of RIA Development Direction using Suggestion System (제안제도를 활용한 RIA 발전 방향에 관한 연구)

  • Shin, Young-Kyun;Chun, Jun-Hong;Kim, Yeon-Ok;Lee, Seon-Ho;Kim, Seong-Ho;Yoo, Seon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.106-112
    • /
    • 2011
  • Purpose: Until now, the process was improved by the needs of experimenters personally. But recently, suggestion system in hospital has been activated in various ways. So the department of nuclear medicine laboratory is also aware of the need of operation improvement using suggestion system. It is intend to assist in the development by sharing excellent suggestion cases with other hospitals. Material & Method: A total of 124 suggestion cases from January 2007 to March 2010 were analyzed. Suggestion cases were divided into customer satisfaction, cost reduction, improved testing methods, equipment, environmental improvement, and computational system. Result: Suggestion cases of environmental improvement and computational system were accounted for 26.6% as 33 cases, respectively. Suggestion for customer satisfaction is 25.8% as 32 in a total of 124 cases. Conclusion: Activation of the awareness of operation improvement is induced by suggestion system. By securing system of operation improvement, employees' ideas can lead to the production and systematization. Furthermore, it enhances hospital competitiveness and promotes the development of the hospital.

  • PDF

Developing national level high alert medication lists for acute care setting in Korea (국내 급성기 의료기관 고위험 의약품 목록 도출)

  • Han, Ji Min;Heo, Kyu-Nam;Lee, Ah Young;Min, Sang il;Kim, Hyun Jee;Baek, Jin-Hee;Rho, Juhyun;Kim, Sue In;Kim, Ji yeon;Lee, Haewon;Cho, Eunju;Ah, Young-Mi;Lee, Ju-Yeun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.32 no.2
    • /
    • pp.116-124
    • /
    • 2022
  • Background: High-alert medications (HAMs) are medications that bear a heightened risk of causing significant patient harm if used in error. To facilitate safe use of HAMs, identifying specific HAM lists for clinical setting is necessary. We aimed to develop the national level HAM list for acute care setting. Methods: We used three-step process. First, we compiled the pre-existing lists referring HAMs. Second, we analyzed medication related incidents reported from national patient safety incident report data and adverse events indicating medication errors from the Korea Adverse Event Reporting System (KAERS). We also surveyed the assistant staffs to support patient safety tasks and pharmacist in charge of medication safety in acute care hospital. From findings from analysis and survey results we created additional candidate list of HAMs. Third, we derived the final list for HAMs in acute care settings through expert panel surveys. Results: From pre-existing HAM list, preliminary list consisting of 42 medication class/ingredients was derived. Eight assistant staff to support patient safety tasks and 39 pharmacists in charge of medication safety responded to the survey. Additional 44 medication were listed from national patient safety incident report data, KAERS data and common medications involved in prescribing errors and dispensing errors from survey data. A list of mandatory and optional HAMs consisting of 10 and 6 medication classes, respectively, was developed by consensus of the expert group. Conclusion: We developed national level HAM list for Korean acute care setting from pre-existing lists, analyzing medication error data, survey and expert panel consensus.

Induced Prism by the Categories of Spectacle Frames (안경테 종류에 따른 유발프리즘)

  • Park, Woo-Jung;Kim, Soo Woon;Hwang, Hae-Young;Yu, Dong-Sik;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.311-319
    • /
    • 2012
  • Purpose: One of the critical aspects on dispensing glasses is to match the center of pupils to the optical center of lenses as the mismatched glasses are able to induce uncomfortable effects called prism which has been known to induce phoria, a main cause for asthenopia in many cases. Therefore, we investigated the induced prism occurred by mismatching centers between the center of pupils and the optical center of lenses. Methods: In this study, total 103 subjects were examined whether the center of pupils and the optical center of lenses are matched in horizontal and vertical directions, and then, the data was categorized into 4 groups based on the structural components of glasses. Total amount of prism was compared to show the effect of the glasses frame on the prism induction, and the value of measured prism was compared with the German RAL-RG 915 regulations. Results: The results in respect to the horizontal component showed that the induced prism was not found in 10.7% of total subjects. 73.8% of total subjects were influenced by induced prism, the range of prism was in a tolerance level. However, the 15.5% of total subjects seemed to be influenced by prism which is out of the criterion of tolerance. In case of vertical component, 23.3% of total subjects showed no effects of prism while early adopting glasses, 54.4% of total subjects showed a little prism effect within the criterion of tolerance, and 22.3% of total subjects showed the prism effect out of the tolerance range. This data indicates that group A and B that are less likely adjustable by fitting induce more prism than group C and D in horizontal and vertical components. Conclusions: In higher refractive error condition, it was found that aligning the optical center of lenses with the center of pupils by pre-fitting of glasses frame minimized prism induction in horizontal and vertical components, which ameliorates ocular fatigue. Therefore, appropriate optometric dispensing through fitting by opticians and precise design about monocular PD and monocular Oh are necessary to improve visual perception.

Analysis of the Eyeglasses Supply System for Ametropes in ROK Military (한국군 비정시자용 안경의 보급체계 분석)

  • Jin, Yong-Gab;Koo, Bon-Yeop;Lee, Woo-Chul;Yoon, Moon-Soo;Park, Jin-Tae;Lee, Hang-Seok;Lee, Kyo-Eun;Leem, Hyun-Sung;Jang, Jae-Young;Mah, Ki-Choong
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.579-588
    • /
    • 2018
  • Purpose : To analyze the eyeglasses supply system for ametropic soldiers in ROK military. Methods : We investigated and analyzed the supply system of eyeglasses for the ametropic soldiers provided by the Korean military. The refractive powers and corrected visual acuity were measured for 37 ametropic soldiers who wear insert glasses for ballistic protective and gas-masks supplied by the military based on their habitual prescriptions. Full correction of refractive error was prescribed for subjects having less than 1.0 of distance visual acuity, and comparison was held for inspecting the changes in corrected visual acuity. Suggestions were provided for solving the issues regarding current supplying system, and this study investigated the applicabilities for utilizing professional optometric manpower. Results : The new glasses supplied by army for ametropic soldiers were duplicated from the glasses they worn when entering the army. The spherical equivalent refractive powers of the conventional, ballistic protective and gas-mask insert glasses supplied for 37 ametropic soldiers were $-3.47{\pm}1.69D$, $-3.52{\pm}1.66D$ and $-3.55{\pm}1.63D$, respectively, and the spherical equivalent refractive power of full corrected glasses was $-3.79{\pm}1.66D$, which showed a significant difference(p<0.05). The distant corrected visual acuity measured at high and low contrast(logMAR) of conventional, ballistic protective and gas-mask insert glasses were $0.06{\pm}0.80$, $0.21{\pm}0.82$, $0.15{\pm}0.74$, $0.34{\pm}0.89$, $0.10{\pm}0.70$ and $0.22{\pm}0.27$, respectively, while the corrected visual acuity by full corrected glasses were increased to $0.02{\pm}1.05$, $0.10{\pm}0.07$, $0.09{\pm}0.92$, $0.26{\pm}0.10$, $0.04{\pm}1.00$ and $0.19{\pm}1.00$, respectively. There was a significant difference(p<0.05) except for the case of the low contrast corrected visual acuity of the conventional and gas-mask insert glasses. The procedure for ordering, dispensing, and supplying military glasses consists of 5 steps, and it was found that approximately two weeks or more are required to supply from the initial examination. Conclusion : The procedure of supplying the military glasses showed three issues: 1) a lack of refraction for prescription system, 2) relatively long length of time required for supplying the glasses, 3) an inaccurate power of supplied glasses. In order to solve those issues, in the short term, education is necessarily required for soldiers on the measurement of the refractive powers, and in the near future, further standard procedures for prescription of glasses as well as the securement of optometric manpower are expected.