• Title/Summary/Keyword: discontinuous

Search Result 1,399, Processing Time 0.032 seconds

Bond characteristics by joint condition between old and. new concrete (신ㆍ구 콘크리트의 접합면 조건에 다른 부착특성)

  • 주봉철;김영진;김병석;박성룡;김덕진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.859-864
    • /
    • 2003
  • In these days, the deterioration of bridges make it necessary for decks to be replaced and it is inevitable to apply the precast decks to minimize the traffic control induced from the deck placement. This precast deck construction makes the physically discontinuous interface between old and new concrete. Usually, the adhesive force at this interface are ignored. However, for crack behavior and reliable long term behavior, it is required to evaluate the exact value of the cohesive force at the interface. This research investigates the cohesive characteristics at the interface. Four different interface surface conditions are tested and three different methods are used to measure the cohesive strength at the interface. In addition, cohesive characteristic at the surface between precast panels are investigated with different interface surface conditions.

  • PDF

Preparation of $\gamma-LiAlO_2$ Short Fibers by the Sol-Gel Method (졸-겔법에 의한 $\gamma-LiAlO_2$ 단섬유의 제조)

  • 현상훈;이재현;홍성안
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.10
    • /
    • pp.1079-1088
    • /
    • 1996
  • Discontinuous ${\gamma}$-LiAlO2 fibers for fiber-reinforcing MCFC matrixes have been produced by the sol-gel process using the centrifugal spinning apparatus of the Rotary type. Gel fibers could be obtained through spinning of stable LiAlO2 complex polymetric sols under the optimum spinning conditions (hollow-disc rotating velocity 9000 rpm sol feeding rate of 4ml/min flowing N2 temperature of 4$0^{\circ}C$ and flowing N2 pressure of 4 bar). It was found that defect free and densified ${\gamma}$-LiAlO2 fibers with the relative density of 98% and the mean diameter of 4.7${\mu}{\textrm}{m}$ were prepared when the spinned fibers were heat-treated to 100$0^{\circ}C$ on the specified heating schedule. in particular the mean diameter and length of fibers could be controlled by the pressure of flowing N2 and the chopping-sieving method respectively.

  • PDF

Effect of solenoid valves on the response characteristics of a hydraulic position-control system (솔레노이드 밸브가 유압위치제어 시스템의 응답특성에 미치는 영향)

  • 장효환;안병홍
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.364-369
    • /
    • 1987
  • It has recently shown that a solenoid valve can be utilized in a hydraulic position-control system by discontinuous control methods. The objective of this study is to investigate the effects of solenoid valves on the response characteristics of a hydraulic position-control system by applying two kinds of discontinued control methods i.e., Simple On-Off (SOF) and Pusating On-Off(POF) controls. Three types of solenoid valves i.e. low-frequency, closed-center type (LF/C), high-frequency, closed-center type (HF/C), low-frequency, tandem-center type(LF/T) were used in this study. Effects of loading conditions and control parameters on the response characteristics were experimentally examined and compared each other. Pressure transients within the actuator were also studied.

  • PDF

Static Output Feedback Sliding Mode Control Design for Linear Systems with Mismatched Uncertainties (비정합 불확실성을 갖는 선형 시스템을 위한 정적 출력 궤환 슬라이딩 모드 제어기 설계)

  • Choi, Han-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.1
    • /
    • pp.15-18
    • /
    • 2007
  • We consider the problem of designing a static output feedback sliding mode control law for linear dynamical systems with mismatched uncertainties in the state matrix. We assume that an output dependent sliding surface guaranteeing the quadratic stability of the sliding mode dynamics is given, the reachability condition is not required to be satisfied globally, and the output feedback sliding mode control law complises both linear and discontinuous parts. We reduce the problem of designing the linear part of the sliding mode control law to a simple LMI problem which offers design flexibility for combining various useful convex design specifications. Our approach does not require state transformation and it can be applied to mismatched uncertain systems.

Load Characteristic of Three-phase AC/DC Boost Converter Using a $PRS^2$. ($PRS^2$를 사용한 3상 AC/DC 컨버터의 부하특성)

  • Kang, Wook-Jung;Lee, Hyun-Woo;Suh, Ki-Young;Beak, Soo-Hyun;Han, Kyung-Hee;Chun, Jung-Ham
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.438-440
    • /
    • 1997
  • This paper proposed a partial resonant switching three-phase high power factor converter using a $PRS^2$(Partial Resonant Soft Switch). The proposed converter has a merit of simple controlled circuit because the input current control DCM(Discontinuous Conduction Mode). And it is improve to input power factor that the snubber capacitor's energy regenerate to the AC source side. This topology is reduced a current/voltage stresses of resonant devices in addition to a partial resonant strategy. The result of simulations with the proposed topology included in this paper.

  • PDF

Comparative Analysis of Charging Modes of Series Resonant Converter for an Energy Storage Capacitor (에너지저장 커패시터의 최적 충전을 위한 직렬공진형 컨버터의 운용 모드 비교)

  • Lee, Byung-Ha;Kang, Tae-Sub;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.394-400
    • /
    • 2012
  • In this paper, charging modes of series resonant converter for a high voltage energy storage capacitor are compared in terms of charging time, peak resonant current, normalized peak resonant current and voltage in each operation mode. Operating principles of the full bridge series resonant converter with capacitor load are explained and analyzed in discontinuous and continuous operation mode. Based on the analysis and simulation result, $0.6{\omega}_r$ < ${\omega}_s$ < $0.75{\omega}_r$ and $1.3{\omega}_r$ < ${\omega}_s$ < $1.4{\omega}_r$ are evaluated to the best range of switching frequency for charging of an high voltage energy storage capacitor. 1.8 kJ/s SRC prototype is assembled with TI 28335 DSP controller and 40 kJ, 7 kV energy storage capacitor. Design rules based on the comparative analysis are verified by experiment.

An Efficient Foot-Force Distribution Algorithm for Straight-Line Walking of Quadruped Robots with a Failed Leg (고장 난 다리가 있는 사족 보행 로봇의 평탄 직선보행을 위한 효율적인 다리 힘 배분 알고리즘)

  • Yang, Jung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.896-901
    • /
    • 2008
  • This paper addresses the foot force distribution problem for quadruped robots with a failed leg. The quadruped robot has fault-tolerant straight-line gaits with one leg in locked-joint failure, and has discontinuous motion with respect to the robot body. The proposed method is operated in two folds. When the robot body stands still, we use the feature that there are always three supporting legs, and by incorporating the theory of zero-interaction force, we calculate the foot forces analytically without resort to any optimization technique. When the robot body moves, the conventional pseudo-inverse algorithm is applied to obtain the foot forces for supporting legs. Simulation results show the validity of the proposed scheme.

Analysis on characteristic of Microstrip Line which has a discontinuous region (불연속 구조를 가지는 Microstrip Line 전송선로의 특성 분석)

  • Jeong, Jonghee;Kim, Kwangho;Nah, Wansoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.131-132
    • /
    • 2015
  • 현대 사회의 기술 발달에 따라서 회로의 집적도 대비 이용하는 주파수가 매우 높아지고 있다. 즉, 회로의 이용 주파수가 높아짐에 따라서 파장이 신호를 전달하는 전선만큼 짧아져 기존의 회로이론을 기반으로 하는 집중 정수 회로적 관점으로 해석할 수 없다. 따라서 전송선로 이론에 따라 해석하여야 하지만, 최근 전자기기들은 높은 집적도나 여러 모듈(Module)을 종합해서 만들기 때문에 전기적 특성이 일정한 전송선로의 이론을 적용하기가 힘들며, 따라서 이는 불연속을 고려한 전송선로의 분석이 이루어져야 함을 시사한다. 이에 본 논문에서는 전송선로에서 불연속 구간이 존재할 경우 기존의 전송선로 이론을 적용한 전기파라미터 변환에 미치는 영향을 알아보기 위해서 불연속 구간이 존재하는 마이크로 스트립 구조를 설계해 VNA(Vector Network Analyzer)를 이용해서 산란계수(S-Parameter)를 측정 및 분석하였다.

  • PDF

The Evaluation of the Fracture Criterion having an Effect on Crack Extension Simulation for a Thin Sheet (박판시험편의 균열성장 시물레이션에 미치는 파괴기준 평가)

  • 권오헌
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.15-19
    • /
    • 2000
  • The exact estimation of the ductile crack growth in a thin sheet would be needed in part of the commercial transport aircraft industry fields. A 2-dimensional elastic plastic finite element analysis was carried out to simulate a stable crack extension in a thin sheet 2024 aluminium alloy. Two kinds of crack modeling were used to evaluate curves of the stable crack extension. And then CTOA(crack tip opening angle) and CTED(crack tip energy density) were calculated in order to determine whether they can be used as useful crack extension criterions in a thin sheet. Results indicate that stable crack extension behaviors were simulated well and CTED is more admirable even though CTOA also is reasonable as a criterion for a stable crack extension in a thin 2024 aluminium alloy sheet.

  • PDF

Effect of Width and Thickness Ratio on the Fatigue Crack Arrest Behavior of SA-508 Pressure Vessel Steel Variable Thickness Plates (SA-508 압력용기용강 변후재의 피로균열 Arrest 거동에 대한 변후 형상비의 영향)

  • 이환우;이갑래;최용식
    • Journal of the Korean Society of Safety
    • /
    • v.6 no.4
    • /
    • pp.45-52
    • /
    • 1991
  • The purpose of a fatigue crack arrest desing is to prvent a fatigue fracture of machine and structure resulted from unstable crack growth. In all cases of load transfer to second elements such as stringers, doublers or flangers, crack arrest is possible; arrest occuring when the fatigue crack reaches the second element. In the present work, the possibility of crack arrest and the design criterion of fatigue crack arrest in the variable thickness plates are examined numericaiiy by using fatigue crack arrest thresthod $\Delta$K$_{th}$of SA-508 reactor vessel steel and stress intensity factor which was obtained in the previous work as a result of 3-dimensional finite element analysis for CT type variable thickness plates having discontinuous interface.e.

  • PDF