• 제목/요약/키워드: discharging water

검색결과 228건 처리시간 0.022초

다관형 잠열축열장치의 축열특성연구 -물을 매체로 한 축열 및 방열과정 분석- (Study on the Thermal Storage Characteristics of a Multi-capsule type LTES System -Analysis for Heat Charging and Discharging Process for Water Flow-)

  • 김영복
    • Journal of Biosystems Engineering
    • /
    • 제19권1호
    • /
    • pp.62-69
    • /
    • 1994
  • This study was designed to seek information on the heat charging and discharging characteristics of a multi-capsule type LTES(Latent Heat of Fusion Thermal Energy Storage) system, and especially prediction equation of outlet water temperature from the system. During heat charging process, the water temperature in the LTES tank increased very slowly in comparison with a predicted one and was kept near the melting point of the PCM for about 25 minutes. During heat discharging process, the latent heat discharging period of the outlet water temperature became longer as the inlet water temperature became higher and/or mass flow rate became lower. The dimensionless temperature of the outlet water was predicted by linking three equations of ${\theta}=1.1Exp(-{\tau}/0.82)$, ${\theta}=-0.06{\tau}+0.3$, ${\theta}=0.8Exp(-{\tau}/1.4)$ ($r^2{\leq}0.88$) depending on discharging period regardless of mass flow rates on the case of the inlet water temperature at $21.5^{\circ}C$.

  • PDF

영산강 하구둑과 영암-금호방조제 방류에 의한 목포항 주변 수역의 수질변화에 관한 연구 (A Study on the Change of Water Quality in the Vicinity of Mokpo Harbor Due to the Discharges from Yongsan River Estuary Weir and Yongam-Kumho Sea Dike)

  • 정대득;이중우;국승기
    • 한국항만학회지
    • /
    • 제13권2호
    • /
    • pp.419-426
    • /
    • 1999
  • It is essential for port planning, coastal zone management and environmental impact study to analyze the variation of current and water quality due to the development of water area and discharged water from estuary barrage and basin etc. Mokpo sea area downstreams from a long river and two large basins, the Yongsan river and Yongam-Kumho basins discharging much of water through water gates for the purpose of flood control and prohibition of salt intrusion to the inland fresh water area. In this study, the numerical calculations were carried out for the analysis of diffusion characteristics due to discharging operation, adapting the results of tidal current simulation ADI methord is applied to the governing equation for the movement of sea water and diffusion and 6-point method to the advection terms of diffusion equation. As the results of this study, it is known that the discharging operation causes increasing and/or decreasing of current velocity and enlarging and/or depressing of pollutant diffusion limits depending on the distance from the discharging gates and the mode of discharging operation. To utilize these result, the linked gate operation and the method increasing exchange of sea water must be considered.

  • PDF

영산강 하구둑과 영얌-금호방조제 방류에 의한 목포항 주변 수역의 수질변화에 관한 연구 (A Study on the Charge of Water Quality in the Vicinity of Mokpo Harbor due to the Discharges from Yongsan River Estuary Weir and Yongam-Kumho Sea Dike)

  • 정대득;이중우;국승기
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1999년도 추계학술대회논문집
    • /
    • pp.253-261
    • /
    • 1999
  • It is essential for port planning, coastal zone management and environmental impact study to analyze the variation of current and water quality due to the development of water area and discharged water from the estuary barrage and basin, etc. Mokpo sea area has downstream from a long river and two large basins, the Yongsan river and Yongam-Kumho basins, discharging much of water through water gates for the purpose of flood and prohibition of salt intrusion to the inland fresh water area. In this study, the numerical calculation were carried out for the analysis of diffusion characteristics due to discharging operation, adopting the results of tidal current simulation. ADI method is applied to the governing equation for the movement of sea water and diffusion and 6-point method to the advection terms of diffusion equation. As the results of this study, it is known that the discharging operation causes increasing and/or decreasing of current velocity and enlarging and/or depressing of pollutant diffusion limits depending on the distance from the discharging gates and the modes of discharging operation. To utilize these result, the linked gate operation and the method increasing exchange of sea water must be considered.

다공성 수침-평판전극간의 수적 방출 특성 (Water Droplet Ejection Characteristics of a Wet Porous Point-Plate Airgap)

  • 정재승;이우석;문재덕
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2005-2010
    • /
    • 2009
  • Water droplet ejection characteristics of a point-to-plate airgap, with a wet porous point as a corona electrode, has been investigated. And the water droplet traces, charge, mass and number were measured experimentally. More particles are observed with wet porous point than metal point because the corona-discharging wet porous point can eject a number of water droplets. The water droplets ejected from the positive-corona-discharging wet porous point showed very fine traces as compared with those from the negative-corona-discharging wet porous point. Moreover, the water droplets ejected from the AC-corona-discharging wet porous point showed granular-like larger traces. It was shown that the weak corona discharge can eject smaller water droplets with larger ratio of mass-to-charge than the intense corona discharge.

Heat Transfer Characteristics of the Spherical Capsule Storage System Using Paraffins

  • Cho, Keum-Nam;Choi, S. H.
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.113-123
    • /
    • 1998
  • The present study is to investigate the effect of experimental parameters on the heat transfer characteristics of a spherical capsule storage system using paraffins. N-Tetradecane and mixture of n-Tetradecane 40% and n-Hexadecane 60% were used as paraffins. Water with inorganic material was also tested for the comparison. The experimental parameters were varied for the Reynolds number from 8 to 16 and for the inlet temperature from -7 to 2$^{\circ}C$. Measured local temperatures of spherical capsules in the storage tank were utilized to calculate charging and discharging times, dimensionless thermal storage amount, and the average heat transfer coefficients in the tank. Local charging and discharging times in the storage tank were significantly different. The effect of inlet temperature on charging time was larger than that on discharging time, but the effect of Reynolds number on charging time was smaller than that on discharging time. Charging time of paraffins was faster by 11~72% than that of water with inorganic material, but little difference of discharging time was found among them. The effect of Reynolds number on the dimensionless thermal storage was less during charging process and more during discharging process than the effect of inlet temperature. The effect of the inlet temperature and the Reynolds number on the average heat transfer coefficient of the storage tank was stronger during discharging process than during charging process. The average heat transfer coefficients of the spherical capsule system using paraffins were larger by 40% than those using water.

  • PDF

2계면 플라즈마 방전시스템(DBD System)의 특징 및 소독제로서 방전수의 사용가능성에 대한 연구 (Study on the Characteristics of Dielectric Barrier Discharging System and Usability as a Disinfectant)

  • 류승민;박희경;이봉주
    • 상하수도학회지
    • /
    • 제18권4호
    • /
    • pp.529-536
    • /
    • 2004
  • Innovated technique to inactivate microorganisms has been developed. This technique uses plasma discharge in 2-phase (Air-Water). Dielectric Barrier (two phase) Discharging system is able to produce new oxidants for microorganisms. Products from discharging are $HNO_2$, $NO_2{^-}$, $HNO_3$, $NO_3{^-}$ and ozone but many other radicals can be generated as well. DBD water has low concentration of ozone (about 0.5mg/L), $NO_2{^-}$, $NO_3{^-}$ (about 10mg-N/L, 20mg-N/L respectively) and lots of $H^+$. These products play an important role in oxidation. Oxidation power by KI titration methods is approximately equivalent to $50mg-O_3/L$. Surprisingly stored DBD water could oxidize KI and maintain stable pH (about pH3) even after several days. Stored DBD water for 5 days has also more than 4log disinfection power to E. coli. However, DBD water cannot be used for drinking water directly due to it's toxicity. Additional process to neutralize pH and decrease toxicity must be applied.

염수농도에 따른 휴대폰 배터리의 방전특성과 화재 위험성 분석 (Analysis of Discharge Characteristics and Fire Risk of Mobile Phone Batteries according to the Concentration of Salt Water)

  • 우진수;소수현
    • 한국화재소방학회논문지
    • /
    • 제34권1호
    • /
    • pp.66-71
    • /
    • 2020
  • 리튬-이온 배터리를 폐기하는 방법으로 흔히 사용되고 있는 염수를 이용한 방전 방법은 자칫 화재로 이어질 개연성이 있음에도 불구하고 배터리의 염수 방전 과정의 화재 위험성에 대한 연구는 많지 않다. 본 연구에서는 리튬-이온 배터리 중 휴대폰 배터리를 대상으로 하여 염수에 배터리를 담가 방전 시킬 때 방전특성과 발열에 의한 화재 발생 가능성을 확인하고자 염수농도와 배터리의 개수를 변화시킨 여러 조건에서 실험을 수행하였다. 각 조건에서 방전전압 및 배터리의 발열온도를 측정하여 방전 과정 및 발열에 의한 화재 위험성을 예측하였다. 실험 결과로는, 염수농도가 높을수록 휴대폰 배터리의 방전이 더 잘 되었으며, 발열온도 또한 높게 측정 되었고, 염수에 침수된 배터리 1개의 발열온도보다 중첩된 배터리의 발열온도가 더 높게 측정되었다. 또한, 배터리의 가장 높은 발열이 발생하는 부분은 (+),(-)전극에서 발생하는 것을 알 수 있었다.

수질분야 환경영향평가의 개선방안 - 환경오염시설의 통합관리와 대비하여 - (Water Quality Impact Assessment in Korea - Comparing with the Integrated Control of Pollutant-Discharging Facilities -)

  • 이종호;조재현
    • 환경영향평가
    • /
    • 제26권5호
    • /
    • pp.331-343
    • /
    • 2017
  • 본 연구는 수질관리 측면에서 주요한 여건 변화 즉 환경오염시설의 통합관리의 도입 시행에 유의하여 수질분야 환경영향평가 개선방안을 모색하였다. 이를 위해 먼저 환경영향평가시 적용되는 배출허용기준, 방류수수질기준, 수질오염총량관리, 수질보전을 위한 토지이용규제를 고찰하였다. 그리고 환경오염시설의 통합관리에 따라 도입된 최대배출기준, 허가배출기준, 한계배출기준 등을 고찰한 후, 최적가용기법과 미국의 최적가용기법 및 관련 제어기술과 비교하며, 수질분야 환경영향평가와 환경오염시설의 통합관리를 비교하였다. 수질분야 환경영향평가 개선방안으로 첫째 영향예측과 평가에 배출영향분석기법과 허가배출기준설정의 반영, 둘째 협의기준에 허가배출기준의 반영으로 강화된 농도규제와 대상 수질항목이 확대된 수질오염 총량관리의 구현, 셋째 저감방안에 통합관리사업장의 배출원 성격과 수질오염물질 특성에 따른 최적가용기법의 다양한 운영, 넷째 저감방안에 영양염류제어를 위한 질산염취약지구와 같은 토지이용규제의 도입, 다섯째 환경영향평가서 수질분야 항목과 토지이용분야 항목간의 연계성 강화 등을 제시하였다.

수조로 방출되는 기포 거동에 대한 수치해석 (Numerical Simulation on the Behavior of Air Cloud Discharging into a Water Pool)

  • 김환열;김영인;배윤영;송진호;김희동
    • 에너지공학
    • /
    • 제11권3호
    • /
    • pp.237-246
    • /
    • 2002
  • 한국형차세대원자로 APR-1400의 안전감압계통이 작동하면 물, 공기 및 증기가 sparger를 통해 격납건물 내 핵연료재장전 수조로 차례로 방출된다. 방출 과정 중 생기는 여러 현상 중에서 수조 내의 공기 기포군은 저주파, 고진폭의 진동 하중을 발생하며, 주파수가 침수 구조물의 고유 주파수와 거의 같은 경우에는 구조물에 심각한 영향을 줄 수 있다. 이러한 현상은 복잡하기 때문에 주파수와 하중에 대한 규명은 주로 실험에 의존해 왔으며 수치해석적 연구는 이루어지지 않았다. 본 연구에서는 sparger를 통해 수조 내로 방출되는 공기 기포군의 거동에 대한 수치해석을 상용 열수력 해석 코드인 FLUENT Version 4.5를 사용하여 수행하였다. 다상유동 해석모델중 VOF(Volume Of Fluid)모델을 사용하여 물, 공기 및 증기 등의 다상유동을 모의하였다. 해석결과를 sparger 개발을 위해 ABB-Atom이 수행하였던 실험결과와 비교하여 만족할만한 결과를 얻었다.

파라핀 축열재를 사용한 구형캡슐 시스템의 전열성능 (Thermal performance of the spherical capsule system using paraffin as the thermal storage material)

  • 조금남;최승학
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.354-363
    • /
    • 1997
  • The purpose of the present work is to show the best thermal storage material and the sensitivity of the parameters on the thermal performance by experimentally investigating the effects of the parameters on the thermal performance of the spherical capsule system using paraffins superior to the commercial one. The paraffins were n-Tetradecane and the mixture of n-Tetradecane 40% and n-Hexadecane 60%. The experimental parameters were the Reynolds number of 8, 12, and 16 and the inlet temperature of-7, -4, -1, and $2^{\circ}C$. The charging and the discharing time, the dimensionless thermal storage amount, and the averge heat transfer coefficient in the tank were obtained by utilizing the local temperature variation in the tank. The local charging and discharging time in the tank was axially and radially different a lot. The effects of the inlet temperature on the charging and the discharging time were larger during the charging process than during the discharging process, but the effects of the Reynolds number on the charging and the discharging time were in reverse order. The paraffins were better by 11~72% than the water with the inorganic material in the charging time aspect, but no difference in the discharging time aspect. The effects of the Reynolds number on the dimensionless thermal storage amount were smaller than the effects of the inlet temperature during the charging process, but in reverse order during the discharging process within the working range of the experimental parameters. The effects of the inlet temperature and the Reynolds number on the average heat transfer coefficient were larger during the discharging process than during the charging process. The average heat transfer coefficient for the paraffins was larger by 40% maximum than that for the commercial material during the charing and the discharging process.

  • PDF