• Title/Summary/Keyword: discharge suppression

Search Result 58, Processing Time 0.031 seconds

Application of wavelet filtering for Suppression of noise from PD signals (부분방전신호로부터 노이즈의 제거를 위한 웨이블렛필터링 기법의 적용)

  • Lee, K.W.;Park, C.H.;Kang, S.H.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1845-1848
    • /
    • 2003
  • PD(Partial Discharge) signal have the range from several kHz to several GHz. External noises don't give any interference to discerning PD signals with high frequency bandwidth between several hundreds MHz to several GHz but, in the range between several decades kHz to several MHz, are big obstacles to prevent from discriminating PD signals. Therefore, selecting appropriate filter to decrease the influence of noise is important problem. PD signals have the characteristics both short duration and non-continuous pulse train. For separating PD signals from External noises, some different filtering methods different from conventional ones are needed and wavelet filtering method was convinced to be suitable filtering method in various investigations. This paper has simulated PD signal and various noises and investigated the influences for the performance of wavelet filter by varying the components relative to designing of wavelet filter and constructed suitable one. For the purpose of convincing the performance of wavelet filter, real PDs were produced in needle to plane electrode structure. This small PD signal was mixed with external noises and filtered with wavelet filter. We have obtained apparent PD signals and noises are well suppressed by wavelet filter.

  • PDF

Application of Technique Discrete Wavelet Transform for Acoustic Emission Signals (음향방출신호에 대한 이산웨이블릿 변환기법의 적용)

  • 박재준;김면수;김민수;김진승;백관현;송영철;김성홍;권동진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.585-591
    • /
    • 2000
  • The wavelet transform is the most recent technique for processing signals with time-varying spectra. In this paper, the wavelet transform is utilized to improved the assessment and multi-resolution analysis of acoustic emission signals generating in partial discharge. This paper especially deals with the assessment of process statistical parameter using the features extracted from the wavelet coefficients of measured acoustic emission signals in case of applied voltage 20[kv]. Since the parameter assessment using all wavelet coefficients will often turn out leads to inefficient or inaccurate results, we selected that level-3 stage of multi decomposition in discrete wavelet transform. We applied FIR(Finite Impulse Response)digital filter algorithm in discrete to suppression for random noise. The white noise be included high frequency component denoised as decomposition of discrete wavelet transform level-3. We make use of the feature extraction parameter namely, maximum value of acoustic emission signal, average value, dispersion, skewness, kurtosis, etc. The effectiveness of this new method has been verified on ability a diagnosis transformer go through feature extraction in stage of acting(the early period, the last period) .

  • PDF

Electrical Properties of Silicone Rubber with Different Particle Size and Amount of ATH (ATH의 입자크기 및 첨가량에 따른 실리콘 고무의 전기적 특성)

  • Park, Hoy-Yul;Kang, Dong-Pil;Ahn, Myeong-Sang;Myung, In-Hae;Lee, Tae-Hui;Lee, Tae-Joo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.227-230
    • /
    • 2003
  • Silicone rubber has very excellent chemical stability and hydrophobicity. A hydrophobic surface can prevent the formation of continuous water films on the surface in wet and heavily contaminated conditions. This phenomenon contributes to the suppression of leakage current and partial discharges on insulator surfaces. Silicone rubber has been used much for housing materials of polymer insulators. ATH is added to the silicone rubber for improvement of its resistance against surface discharge. In this paper, ATH with different particle size and content was added to the silicone rubber during compounding. Silicone rubber was deteriorated by a corona treatment. Hydrophobicity recovery rate after corona treatment and arc resistance of silicone rubber were investigated. Hydrophobicity recovery rate of silicone rubber was evaluated by the measurement of contact angle. Arc resistance was evaluated by measuring weight loss of silicone rubber after arc resistance test. It was observed that the hydrophobicity recovery rate and arc resistance of silicone rubber were different when different particle size and content of ATH were added.

  • PDF

Case report : Administration of amiodarone for polymorphic ventricular tachycardia due to long QT syndrome during out-of-hospital advanced cardiac life support (병원 밖 전문 심장소생술에서 긴QT증후군에 의한 Polymorphic Ventricular Tachycardia에 아미오다론이 투여된 1예)

  • Kang, Min Seong;Kim, Ji-Won
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.3
    • /
    • pp.155-160
    • /
    • 2020
  • Torsades de pointes refers to polymorphic ventricular tachycardia (PMVT), which is caused by the suppression of potassium channels owing to genetic and electrolytic abnormalities, resulting in the extension of the QT interval. Symptoms range from spontaneous circulation recovery to fainting and sudden death. Defibrillation, magnesium correction, and the use of lidocaine as an antiarrhythmic agent are recommended as treatments for persistent torsades de pointes. Currently, only amiodarone is available in the ambulance; however, torsades de pointes does not respond efficiently to amiodarone because it suppresses potassium channels and increases the refractory period of the myocardium. Lidocaine, in contrast, reduces the relative refractory period of the myocardium caused by suppressing sodium channels; thus, it inhibits the occurrence of and treats arrhythmia. In cases where PMVT did not respond to defibrillation, the administration of lidocaine showed no difference in survival and discharge rates compared to amiodarone. Thus, ambulances must be equipped with provisions to administer lidocaine.

A Study on the Extinguishing Performance of Water Mist with Additives (첨가제가 혼합된 미세물분무의 소화성능에 관한 연구)

  • 이경덕;신창섭
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • Halogen-based fire suppressing agents have environmental problems because they cause the stratospheric ozone depletion and globe warming. Hence, fire suppression system using fine water mist became the center of interest as a substitution of halon. As a study about this, it is in progress to make the optimum droplet size by using water mist nozzles and to improve the extinguishing performance of water mist by using additives. Before this study, the extinguishing time of ethanol and n-heptane pool fire was measured with changing of water mist droplet size, flow density, discharge pressure, and fire size. In this study, on adding the additives to improve physical and chemical extinguishing performance of water mist, the extinguishing performance would evaluate and the optimum condition would find out. As a result, in case of ethanol pan 1 pool fire, the extinguishing time of the water mist by adding of 2.5 wt% NaCl and 0.3% AFFF got shorter 27% and 60% than the pure water mist. Adding of AFFF was to decrease the flame temperature by forming thin film on the fuel surface and to decrease the evaporation of n-heptane fuel. In case of NaCl, alkali salt crystals showed on the flame surface.

A Numerical Study to Analyze Safety of Pressure Leakage Monitoring System of Gas Extinguishing Agent (가스소화약제 압력누기감시장치의 안전성 분석을 위한 수치적 연구)

  • Go, A-Ra;Lim, Dong-Oh;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.103-110
    • /
    • 2016
  • While the demand for the gas system fire extinguishers increases every year, there are insufficient safety measures for assessing the extinguishing performance, such as system safety and reliability in the preparation of increasing demand, which has emerged as a social problem. One of the most critical causes of accidents occurring with the gas extinguishing system is pressure leakage from the extinguishing agent storage container. This is considered to be one of the critical factors on which the success of fire suppression depends. In this study, its safety measure was studied, Because it was deemed urgently necessary. The newly developed pressure leakage monitoring system is a system monitoring storage condition, pressure, leakage and discharge of the storage container related to agent concentration, which is one of the critical factors for fire suppression. This was developed to be applicable to the $CO_2$ and HFC-23 systems. Therefore, for structural safety analysis, the safety performance was verified by the fluid structure coupling analysis of the safety problems that may occur when the pressure leakage monitoring system is applied to the gas fire extinguisher. For analysis programs, the FloEFD program from Mentor Graphics was used for computational fluid dynamics analysis and ABAQUS from Dassault Systems was used for structural analysis. From the result of numerical analysis, the structure of $CO_2$ did not develop plastic deformation and its safety was verified. However, plastic deformation and deviation issue occurred with the HFC-23 monitoring system and therefore verified the structural safety of pressure leakage monitoring system by data obtained from redesigning and adjusting the condition of numerical interpretation three times.

EEG can Predict Neurologic Outcome in Children Resuscitated from Cardiac Arrest (심정지 후 회복된 소아 환자에서 뇌파를 통한 신경학적 예후 예측)

  • Yang, Dong Hwa;Ha, Seok Gyun;Kim, Hyo Jeong
    • Journal of the Korean Child Neurology Society
    • /
    • v.26 no.4
    • /
    • pp.240-245
    • /
    • 2018
  • Purpose: Early prediction of prognosis of children resuscitated from cardiac arrest is a major challenge. We investigated the utility of electroencephalography (EEG) and laboratory studies for predicting of neurologic outcome in children resuscitated from cardiac arrest. Methods: We retrospectively analyzed medical records of patients who were resuscitated from cardiac arrest from 2006 to 2015 at the Gil Medical Center. Patients aged one month to 18 years were included. EEG analysis included background scoring, reactivity and seizure burden. EEG background was classified score 0 (normal/organized), score 1 (slow and disorganized), score 2 (discontinuous or burst suppression), and score 3 (suppressed and featureless). Neurologic outcome was evaluated by Pediatric Cerebral Performance Category (PCPC) at least 6 months after cardiac arrest. Results: Total 26 patients were evaluated. Nine patients showed good neurologic outcome (PCPC 1, 2, 3) and 17 patients showed poor neurologic outcome (PCPC 4, 5, 6). Patients of poor neurologic outcome group showed EEG background score 3 in 88.2%, whereas 44.4% in patients of good neurologic outcome group (P=0.028). Electrographic ictal discharges except non-convulsive status epilepticus were presented in 44.4% of good neurologic outcome group and 5.9% of poor neurologic outcome group (P=0.034). Ammonia and lactate levels were higher and pH levels were lower in poor outcome group than good neurologic outcome group. Conclusion: Suppressed and featureless EEG background is associated with poor neurologic outcome and electrographic seizures are associated with good neurologic outcome.

Patterning Zooplankton Dynamics in the Regulated Nakdong River by Means of the Self-Organizing Map (자가조직화 지도 방법을 이용한 조절된 낙동강 내 동물플랑크톤 역동성의 모형화)

  • Kim, Dong-Kyun;Joo, Gea-Jae;Jeong, Kwang-Seuk;Chang, Kwang-Hyson;Kim, Hyun-Woo
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.1 s.115
    • /
    • pp.52-61
    • /
    • 2006
  • The aim of this study was to analyze the seasonal patterns of zooplankton community dynamics in the lower Nakdong River (Mulgum, RK; river kilometer; 27 km from the estuarine barrage), with a Self-Organizing Map (SOM) based on weekly sampled data collected over ten years(1994 ${\sim}$ 2003). It is well known that zooplankton groups had important role in the food web of freshwater ecosystems, however, less attention has been paid to this group compared with other community constituents. A non-linear patterning algorithm of the SOM was applied to discover the relationship among river environments and zooplankton community dynamics. Limnological variables (water temperature, dissolved oxygen, pH , Secchi transparency, turbidity, chlorophyll a, discharge, etc.) were taken into account to implement patterning seasonal changes of zooplankton community structures (consisting of rotifers, cladocerans and copepods). The trained SOM model allocated zooplankton on the map plane with limnological parameters. Three zooplankton groups had high similarities to one another in their changing seasonal patterns, Among the limnological variables, water temporature was highly related to the zooplankton community dynamics (especially for cladocerans). The SOM model illustrated the suppression of zooplankton due to the increased river discharge, particularly in summer. Chlorophyll a concentrations were separated from zooplankton data set on the map plane, which would intimate the herbivorous activity of dominant grazers. This study introduces the zooplankton dynamics associated with limnological parameters using a nonlinear method, and the information will be useful for managing the river ecosystem, with respect to the food web interactions.

Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test (Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가)

  • Joung, Suckhwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.47-56
    • /
    • 2019
  • Recently, in order to overcome the difficulty of entering a fire source due to the occurrence of a large amount of smoke in the event of a fire in a parking lot, it has used that a method of discharge smoke using air supply, exhaust fans and jet fans installed for ventilation of parking lots. In this study, the variation of flow in the smoke layer was observed using CCTV under two conditions, in which only the air supply fan operates and the manned fan operates together, and the temperature around the plume was compared to Albert eq. to assess its suitability as a parking lot ventilation performance evaluation method. As a result, it was found that the smoke layer could be disturbed if the Jet Fan was operated at the same time, which could lead to the possibility of an initial evacuation disturbance. However, the additional operation of the Jet Fan has been confirmed by the observation CCTV that the emission performance is improved, which is believed to help conduct the suppression operation. The temperature around the plume was measured and compared to Alpert eq, and was analyzed to be about $2^{\circ}C$ lower at the center axis of the plume and $9.0^{\circ}C$ higher at 8 m in the direction of the discharge of smoke. The results of temperature measurements around the plume were lower than the maximum temperature expected in AS 4391 and did not exceed the expected temperature risk caused by the experiment. As with these results, the temperature risk from the progression of hot smoke tests is foreseeable, so it will be available as one of the general evaluation methods for assessing smoke control performance in a parking lot without relevant criteria.

Effects of $Ca^{2+}-antagonists$ on the electrical activity of guinea-pig taenia coli (결장뉴 전기활동도에 대한 칼슘 길항제의 영향)

  • Kim, Ki-Whan;Kim, Woo-Gyeum
    • The Korean Journal of Physiology
    • /
    • v.19 no.1
    • /
    • pp.1-13
    • /
    • 1985
  • The influences of $Ca^{2+}-antagonists$, verapamil and $Mn^{2+}$, upon the spontaneous electrical activity and contractions were studied in guinea-pig taenia coli. Spontaneous contractions were recorded with force transducer, and spike action potentials were measured extracellularly by use of suction electrode. All experiments were performed in tris-buffered Tyrode solution Which was aerated With 100% $O_2$ and kept at $35^{\circ}C$. The results obtained were as follows : 1) Verapamil suppressed the frequency and amplitude of spontaneous contractions dose dependently, and blocked completely mechanical responses at the concentration of 1 mg/1. 2) The frequency of bursts of spike discharge(bursts frequency) and the number of spikes in a burst(spikes frequency) were reduced in a dose·dependent manner within the concentration range of $10^{-5}$ to $10^{-3}g/l$, and bursts frequency was affected more readily at a low concentration of $10^{-5}g/l$ verapamil. 3) The verapamil_induced suppression of spontaneous contractions in the Tyrode solution containing 1 mM $Ca^{2+}$ was completely antagonized by the addition of extra $Ca^{2+}$ to the Tyrode solution $(2\;m\;MCa^{2+})$. 4) $Mn^{2+}$ suppressed the amplitude of spontaneous contractions, whereas $Mn^{2+}$ accelerated the frequency dose-dependently within the range of low concentrations$(10^{-7}\;to\;10^{-4}\;M\;Mn^{2+})$. 5) The bursts frequency determining frequency of spontaneous contractions was increased in a dose-dependent manner, whereas the spikes frequency known to determine the contractions amplitude was reduced within the range of low concentrations. At a high concentration of 1 mM $Mn^{2+}$, however, all spontaneous contractile responses were blocked simultaneously with the disapperance of electrical activity. 6) The frequency and amplitude of spontaneous contractions altered by $Mn^{2+}$ in 1mM $Ca^{2+}$ Tyrode were increased by extra $Ca^{2+}(2mM)$.

  • PDF