• Title/Summary/Keyword: discharge measurement method

Search Result 362, Processing Time 0.031 seconds

Effect of Breast-feeding Education and Follow-up care on the Breast-feeding Rate and the Breast-feeding Method - Focused on Home Visit and Phone Counselling - (모유수유교육과 추후간호방법이 산모의 모유수유실천율과 모유수유방법에 미치는 효과 - 가정방문과 전화상담을 중심으로 -)

  • Park, Sook-Hee;Koh, Hyo-Jung
    • Women's Health Nursing
    • /
    • v.7 no.1
    • /
    • pp.30-43
    • /
    • 2001
  • This was a pre-experimental study to confirm the breast-feeding ability and effect of follow up care on the breast-feeding rate and the breast-feeding method by the mother-infant breast-feeding assessment tool for the mothers who got the breast-feeding education. The subjects were 46 mothers who experienced normal delivery of infants at a college hospital in K-city, Kyungsangbuk-do, from July 1 to October 21, 2000. The instrument for data obtainment were The Mother-Infant Breast-Feeding Assessment Tool of Johnson et al. (1999), and The Breast- Feeding Method Measurement Tool of Jeong, Geum-hee(1997). This instrument was reliable, showing Cronbach $\alpha$.751. This study classified them into 3 groups: at high risk for breast-feeding failure, at risk for breast-feeding problems, and at low risk for breast-feeding failure by the mother-infant breast-feeding assessment tool on the day of discharge from the hospital after delivering individual breast-feeding education to the subjects. This study investigated the breast-feeding rate and the breast-feeding method through mail questionnaire at the four week after childbirth, and through the phone counselling and the home visit for follow up care at the first week and the second week after childbirth. The sixth week after childbirth, this study investigated the breast-feeding rate by phone. The data analyzed the hypothesizes by $x^2$-test, paired t-test, ANOVA, Wilcoxon signed rank test, Wilcoxon rank sum test and trend analysis using SPSS/PC+ WIN 10.0 program. The results were as follows : 1) Hypothesis 1-1, "there won't be any difference the breast-feeding rate of a group at risk for breast-feeding failure by the time elapsed" was supported through constant the breast-feeding rate, because changes in the breast-feeding rate by the time elapsed after childbirth wasn't statistically significant(t= -1.501, p=.270). Hypothesis 1-2, "there won't be any difference the breast-feeding rate of group at low risk for breast-feeding failure by the time elapsed" was supported through constant the breast-feeding rate, because changes in the breast-feeding rate by the time elapsed after childbirth wasn't statistically significant(t=-1.732, p=.225). 2) Hypothesis 2-1, "there won't be any difference between the breast-feeding method of group at risk for breast-feeding failure for four weeks after childbirth and just after childbirth” was rejected, because the mean point of post test appeared to be higher than that of pre test(t=-7.267, p=.000). Hypothesis 2-2, "there won't be any difference between the breast-feeding method of the group at low risk for breast-feeding failure for four weeks after childbirth and just after childbirth" was rejected, because the mean point of post test appeared to be higher than that of pre test(t=-2.501, p=.012). 3)The 3rd hypothesis, "there won't be any difference between breast-feeding method of groups at risk for breast-feeding problems and at low risk for breast-feeding failure at the 4th week after childbirth and just after childbirth" didn't show any difference between the breast-feeding method of groups at risk for breast-feeding problems and at low risk for breast-feeding failure in the advance test(t=-1.521, p=.130) but there was difference between them in post test (t=-2.012, p=.044). As a result, the 3rd hypothesis was supported by pre test, but it was rejected by post test. In conclusion, this study confirmed breast- feeding education and follow up care just after childbirth were effective for the breast-feeding rate and method. Accordingly, it is proposed that successful nursing intervention of breast-feeding to be necessary by continuously providing follow up care through the mother-infant breast-feeding assessment tool as well as to execute individual breast-feeding education to mothers just after childbirth.

  • PDF

Controlling the Work Functions of Graphene by Functionalizing the Surface of $SiO_2$ Substrates with Self-assembled Monolayers

  • Jo, Ju-Mi;Kim, Yu-Seok;Cha, Myeong-Jun;Lee, Su-Il;Jeong, Sang-Hui;Song, U-Seok;Kim, Seong-Hwan;Jeon, Seung-Han;Park, Jong-Yun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.400-401
    • /
    • 2012
  • 그래핀(Graphene)은 열 전도도가 높고 전자 이동도(200 000 cm2V-1s-1)가 우수한 전기적 특성을 가지고 있어 전계 효과 트랜지스터(Field effect transistor; FET), 유기 전자 소자(Organic electronic device)와 광전자 소자(Optoelectronic device) 같은 반도체 소자에 응용 가능하다. 그러나 에너지 밴드 갭이 없기 때문에 소자의 전기적 특성이 제한되는 단점이 있다. 최근에는 아크 방출(Arc discharge method), 화학적 기상 증착법(Chemical vapor deposition; CVD), 이온-조사법(Ion-irradiation) 등을 이용한 이종원자(Hetero atom)도핑과 화학적 처리를 이용한 기능화(Functionalization) 등의 방법으로 그래핀을 도핑 후 에너지 밴드 갭을 형성시키는 연구 결과들이 보고된 바 있다. 그러나 이러한 방법들은 표면이 균일하지 않고, 그래핀에 많은 결함들이 발생한다는 단점이 있다. 이러한 단점을 극복하기 위해 자가조립 단층막(Self-assembled monolayers; SAMs)을 이용하여 이산화규소(Silicon oxide; SiO2) 기판을 기능화한 후 그 위에 그래핀을 전사하면 그래핀의 일함수를 쉽게 조절하여 소자의 전기적 특성을 최적화할 수 있다. SAMs는 그래핀과 SiO2 사이에 부착된 매우 얇고 안정적인 층으로 사용된 물질의 특성에 따라 운반자 농도나 도핑 유형, 디락 점(Dirac point)으로부터의 페르미 에너지 준위(Fermi energy level)를 조절할 수 있다[1-3]. 본 연구에서는 SAMs한 기판을 이용하여 그래핀의 도핑 효과를 확인하였다. CVD를 이용하여 균일한 그래핀을 합성하였고, 기판을 3-Aminopropyltriethoxysilane (APTES)와 Borane-Ammonia(Borazane)을 이용하여 각각 아민 기(Amine group; -NH2)와 보론 나이트라이드(Boron Nitride; BN)로 기능화한 후, 그 위에 합성한 그래핀을 전사하였다. 기판 위에 NH2와 BN이 SAMs 형태로 존재하는 것을 접촉각 측정(Contact angle measurement)을 통해 확인하였고, 그 결과 NH2와 BN에 의해 그래핀에 도핑 효과가 나타난 것을 라만 분광법(Raman spectroscopy)과 X-선 광전자 분광법(X-ray photoelectron spectroscopy: XPS)을 이용하여 확인하였다. 본 연구 결과는 안정적이면서 패턴이 가능하기 때문에 그래핀을 기반으로 하는 반도체 소자에 적용 가능할 것이라 예상된다.

  • PDF

Plasma Etching Process based on Real-time Monitoring of Radical Density and Substrate Temperature

  • Takeda, K.;Fukunaga, Y.;Tsutsumi, T.;Ishikawa, K.;Kondo, H.;Sekine, M.;Hori, M.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.93-93
    • /
    • 2016
  • Large scale integrated circuits (LSIs) has been improved by the shrinkage of the circuit dimensions. The smaller chip sizes and increase in circuit density require the miniaturization of the line-width and space between metal interconnections. Therefore, an extreme precise control of the critical dimension and pattern profile is necessary to fabricate next generation nano-electronics devices. The pattern profile control of plasma etching with an accuracy of sub-nanometer must be achieved. To realize the etching process which achieves the problem, understanding of the etching mechanism and precise control of the process based on the real-time monitoring of internal plasma parameters such as etching species density, surface temperature of substrate, etc. are very important. For instance, it is known that the etched profiles of organic low dielectric (low-k) films are sensitive to the substrate temperature and density ratio of H and N atoms in the H2/N2 plasma [1]. In this study, we introduced a feedback control of actual substrate temperature and radical density ratio monitored in real time. And then the dependence of etch rates and profiles of organic films have been evaluated based on the substrate temperatures. In this study, organic low-k films were etched by a dual frequency capacitively coupled plasma employing the mixture of H2/N2 gases. A 100-MHz power was supplied to an upper electrode for plasma generation. The Si substrate was electrostatically chucked to a lower electrode biased by supplying a 2-MHz power. To investigate the effects of H and N radical on the etching profile of organic low-k films, absolute H and N atom densities were measured by vacuum ultraviolet absorption spectroscopy [2]. Moreover, using the optical fiber-type low-coherence interferometer [3], substrate temperature has been measured in real time during etching process. From the measurement results, the temperature raised rapidly just after plasma ignition and was gradually saturated. The temporal change of substrate temperature is a crucial issue to control of surface reactions of reactive species. Therefore, by the intervals of on-off of the plasma discharge, the substrate temperature was maintained within ${\pm}1.5^{\circ}C$ from the set value. As a result, the temperatures were kept within $3^{\circ}C$ during the etching process. Then, we etched organic films with line-and-space pattern using this system. The cross-sections of the organic films etched for 50 s with the substrate temperatures at $20^{\circ}C$ and $100^{\circ}C$ were observed by SEM. From the results, they were different in the sidewall profile. It suggests that the reactions on the sidewalls changed according to the substrate temperature. The precise substrate temperature control method with real-time temperature monitoring and intermittent plasma generation was suggested to contribute on realization of fine pattern etching.

  • PDF

A Study on Changes in Indoor Air Pollution by Educational Activities -Centering on Newly-Established Elementary Schools- (교육활동에 따른 실내오염도 변화에 관한 연구 -신설 초등학교를 중심으로-)

  • Jeon, Seok-Jin
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.6 no.2
    • /
    • pp.66-90
    • /
    • 2007
  • The purpose of this study is to measure and analyze primary causes of indoor air pollution, including carbon dioxide, minute dust, and total volatile organic compounds, for each room before the beginning of a class through the time of discharge after the end of the class in general classrooms, computer rooms, and science rooms of three newly-established schools that opened in 2006, examine properties of indoor air environment in each room by educational activities at school, and determine effective management schemes; the results of this study can be summarized as follows: 1) As for implications for each item found in the mean for each place, since minute dust (PM10) was more likely to occur in time slots full of students' activities, such as a traveling class and a recess, than in the middle of a class and could be expected fully, it is necessary to make a scheme for cleaning in order to reduce minute dust within a room, for example, by usually using a vacuum cleaner indoors. 2) While carbon dioxide was expected to vary with the differences in the amount of breath between higher-graders and lower-graders in a general classroom but showed insignificant difference by grades, showing differences in pollution by four times at a maximum according to the opening of a window as expected, it is necessary to implement artificial or natural ventilation and take a positive measure, for example, by presenting a concrete ventilation scheme, in order to improve indoor air pollution at a room practice. 3) Total volatile organic compounds were found to exceed the standard by more than twice in general classrooms, science rooms, and computer rooms of the schools because of building materials, furnitures including desks and chairs, panels and boards for environment beautification, and items which could be detected even from students' clothes; while a field directly-reading tool was used, obtaining high reliability for the results, it is necessary to apply an analytical method based on process test separately for actual correct measurement if a significantly great amount of total volatile organic compounds appear as compared with other schools due to measuring expenses and consecutive measurements. 4) Since formaldehyde (HCHO) was generally found to exceed the standard in general classrooms, science rooms, and computer rooms, it is necessary to establish and operate a ventilator during a class in a computer room which requires airtightness and a science room in which an organic compound should be used for a class.

  • PDF

Flood Inflow Estimation at Large Multipurpose Dam using Distributed Model with Measured Flow Boundary Condition at Direct Upstream Channels (직상류 계측유량경계조건과 분포형모델을 이용한 대규모 다목적댐 홍수유입량 산정)

  • Hong, Sug-Hyeon;Kang, Boosik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.1039-1049
    • /
    • 2015
  • The inflow estimation at large multipurpose dam reservoir is carried out by considering the water balance among the discharge, the storage change during unit time interval obtained from the observed water level near dam structure and area-volume curve. This method can be ideal for level pool reservoir but include potential errors when the inflow is influenced by the water level slope due to backwater effects from upstream flood inflows and strong wind induced by typhoon. In addition, the other uncertainties arisen from the storage reduction due to sedimentation after the dam construction and water level noise due to mechanical vibration transmitted from the electric power generator. These uncertainties impedes the accurate hydraulic inflow measurement requiring exquisite hydrometric data arrangement for reservoir waterbody. In this study, the distributed hydrologic model using UBC-3P boundary setting was applied and its feasibility was evaluated. Finally, the modeling performance has been verified since the calculated determination coefficient has been in between 0.96 to 0.99 after comparing with observed peak inflow and total inflow at Namgang dam reservoir.

Development of Continuous Rainfall-Runoff Model for Flood Forecasting on the Large-Scale Basin (대유역 홍수예측을 위한 연속형 강우-유출모형 개발)

  • Bae, Deg-Hyo;Lee, Byong-Ju
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.1
    • /
    • pp.51-64
    • /
    • 2011
  • The objective of this study is to develop a continuous rainfall-runoff model for flood prediction on a large-scale basin. For this study, the hourly surface runoff estimation method based on the variable retention parameter and runoff curve number is developed. This model is composed that the soil moisture to continuous rainfall can be simulated with applying the hydrologic components to the continuous equation for soil moisture. The runoff can be simulated by linking the hydrologic components with the storage function model continuously. The runoff simulation to large basins can be performed by using channel storage function model. Nakdong river basin is selected as the study area. The model accuracy is evaluated at the 8 measurement sites during flood season in 2006 (calibration period) and 2007~2008 (verification period). The calibrated model simulations are well fitted to the observations. Nash and Sutcliffe model efficiencies in the calibration and verification periods exist in the range of 0.81 to 0.95 and 0.70 to 0.94, respectively. The behavior of soil moisture depending on the rainfall and the annual loadings of simulated hydrologic components are rational. From this results, continuous rainfall-runoff model developed in this study can be used to predict the discharge on large basins.

Take advantage of ESWL in comparison measurement of Proximal stone against Mid Ureteral Stone according to its provability of pulverization (ESWL을 이용한 Proximal, Mid Ureteral Stone의 쇄석시 각 조건에 대한 쇄석율의 비교 측정)

  • Kang, Kwang-Soo;Lee, Sang-Bok;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.11-17
    • /
    • 2010
  • A urolithiasis, also called calculus, is one of the brutal illnesses, which has constantly harassed humanbeings from time immemorial. However, there is no appropriate method of prevention so far. So, Urological therapy must be followed upon those patients. The biggest problem of urolithiasis is usually causing harsh pain, fever, and throw up. The pain would be more intensified when something came through the ureter or the moment of convulsion caused beyond transmission of urinary calculus. Even strong painkillers, such as fentanyl and Pethidine, can not handle those harshly pain easily. Therefore, a prompt action of medical check up and its therapy must be required to those patients. This thesis paper has put the accent on the specific therapy, known as ESWL (Extracorpereal Shock Wave Lithotripsy), which have generated quite optimum resolution to patients, who received harsh pain from Proximal ureteral stone and Mid ureteral stone and because of its low provability of pulverization. The results of the experiment confirmed that the stone, located between Proximal and Mid ureter, has lower provability of pulverization than distal ureter, because its accuracy rate on shock wave, in respect of breathing, are low. However, decrease in discharge interval have enhanced provability of pulverization. it can also intensify probability of pulverization and its safety by discharging high power with appropriate intervals, and that is more efficient than discharging low power with frequent time.

CFD ANALYSIS OF TURBULENT JET BEHAVIOR INDUCED BY A STEAM JET DISCHARGED THROUGH A VERTICAL UPWARD SINGLE HOLE IN A SUBCOOLED WATER POOL

  • Kang, Hyung-Seok;Song, Chul-Hwa
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.382-393
    • /
    • 2010
  • Thermal mixing by steam jets in a pool is dominantly influenced by a turbulent water jet generated by the condensing steam jets, and the proper prediction of this turbulent jet behavior is critical for the pool mixing analysis. A turbulent jet flow induced by a steam jet discharged through a vertical upward single hole into a subcooled water pool was subjected to computational fluid dynamics (CFD) analysis. Based on the small-scale test data derived under a horizontal steam discharging condition, this analysis was performed to validate a CFD method of analysis previously developed for condensing jet-induced pool mixing phenomena. In previous validation work, the CFD results and the test data for a limited range of radial and axial directions were compared in terms of profiles of the turbulent jet velocity and temperature. Furthermore, the behavior of the turbulent jet induced by the steam jet through a horizontal single hole in a subcooled water pool failed to show the exact axisymmetric flow pattern with regards to an overall pool mixing, whereas the CFD analysis was done with an axisymmetric grid model. Therefore, another new small-scale test was conducted under a vertical upward steam discharging condition. The purpose of this test was to generate the velocity and temperature profiles of the turbulent jet by expanding the measurement ranges from the jet center to a location at about 5% of $U_m$ and 10 cm to 30 cm from the exit of the discharge nozzle. The results of the new CFD analysis show that the recommended CFD model of the high turbulent intensity of 40% for the turbulent jet and the fine mesh grid model can accurately predict the test results within an error rate of about 10%. In this work, the turbulent jet model, which is used to simply predict the temperature and velocity profiles along the axial and radial directions by means of the empirical correlations and Tollmien's theory was improved on the basis of the new test data. The results validate the CFD model of analysis. Furthermore, the turbulent jet model developed in this study can be used to analyze pool thermal mixing when an ellipsoidal steam jet is discharged under a high steam mass flux in a subcooled water pool.

Analysis of Applicability by Filter Technique for Water Level Correction of Agricultural Canal (농업용 수로부의 수위 보정을 위한 필터기법별 적용성 분석)

  • Joo, Donghyuk;Na, Ra;Kim, Ha-Young;Choi, Gyu-hoon;Yun, Hyung Chang;Park, Sang-Bin;Yoo, Seung-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.5
    • /
    • pp.51-68
    • /
    • 2023
  • Due to the recent integrated water management policy, it is important to identify a reliable supply amount for establishing an agricultural water supply plan. In order to identify the amount of agricultural water supply, it is essential to calculate the discharge by measuring the water level and flow velocity of reservoirs and canal agricultural water, and quality control to ensure reliability must be preceded. Unlike agricultural reservoirs, canal agricultural water are more sensitive to the surrounding environment and reservoir irrigation methods (continuous, intermittent irrigation, etc.), making it difficult to estimate general water level patterns and at the same time a lot of erroneous data. The Korea Rural Community Corporation is applying a filter technique as a quality control method capable of processing large quantities and real-time processing of canal agricultural water level data, and applicability evaluation is needed. In this study, the types of errors generated by the automatic water level measurement system were first determined. In addition, by using the manual quality control data, a technique with high applicability is derived by comparing and analyzing data calibrated with Gaussian, Savitzky-Golay, Hampel, and Median filter techniques, RMSE, and NSE, and the optimal parameters of the technique range was derived. As a result, the applicability of the Median filter was evaluated the highest, and the optimal parameters were derived in the range of 120min to 240min. Through the results of this study, it is judged that it can be used for quantitative evaluation to establish an agricultural water supply plan.

Off-Pump Total Arterial Revascularization Using the Skeletonized Right Gastroepiploic Artery as a Third Arterial Conduit; Early and Midterm Results (제3동맥 도관으로서의 골격화된 우위대망동맥을 사용하여 시행한 심폐바이패스를 사용하지 않는 관상동맥 우회술;초기 및 중기 결과)

  • 이현주;최재성;김기봉
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.659-665
    • /
    • 2003
  • The aim of this study was to evaluate the early and midterm results of off-pump total arterial revascularization using the skeletonized right gastroepiploic artery (RGEA) as a third arterial conduit. Material and Method: We prospectively analyzed 103 patients who underwent off-pump total arterial revascularization using bilateral internal thoracic arteries (ITAS) and RGEA. The RGEA was used as in situ graft in 88 patients, composite graft in 10 patients, and free graft in 5 patients. Postoperative coronary angiographies were performed before discharge in 100 patients, and at postoperative one year in 88 patients. Result: The RGEA showed a significantly higher free flow (130$\pm$95 ml/min) than that of right ITA(113$\pm$57 ml/min) or left ITA (107$\pm$55 ml/min), which was measured before anastomosis (p < 0.05). The total number of distal anastomoses was 3.8$\pm$0.7. The number of distal anastomoses per bilateral ITAs was 2.8$\pm$0.7 and the number of distal anastomosis per RGEA was 1.0. There were two morialities including one operative mortality. The late mortality was not related to cardiac events. Early postoperative morbidities were atrial fibrillation in 15 patients, bleeding reoperation in 4 patients, mediastinitis in 1 patients, perioperative myocardial infarction in 2 patient, and transient ARF in 3 patients. Postoperative coronary angiographies showed the early patency rate of 98.6% (272/276) for ITAs and 97.0% (97/100) for RGEA, respectively (p=ns), and the one-year patency rate of 95.9% (234/244) for ITAs and 88.6% (78/88) for RGEA, respectively (p=0.07). Flow competition between the RGEA and NCA (native coronary artery) was seen in 5 of the 100 patients (5.0%) immediate postoperatively and 7 of the 88 patients (8.0%) 1 year after surgery. Since July, 2000, we measured transit time flow intraoperatively and could reduce flow competition significantly Conclusion: The skeletonized RGEA demonstrated excellent early and midterm patency rates and could be used as a third arterial graft following the bilateral ITAs.