This study presents a numerical simulation investigating hydrodynamic characteristics of high-temperature hydrocarbon aviation fuel injected through a plain orifice injector. The analysis encompassed the temperature range up to the critical point, and the obtained results were compared with prior experimental observations. The analysis unveiled that the injector's exit pressure remains equivalent to the ambient pressure when the fuel injection temperature is below the boiling point. However, when the fuel temperature surpasses the boiling point, the exit pressure of the injector transitions to the saturated vapor pressure corresponding to the fuel injection temperature. Consequently, the exit pressure of the injector increases in tandem with the rapid increase of the saturation vapor pressure due to escalating fuel temperatures. This rise in the exit pressure necessitates a proportional increase in fuel injection pressure to ensure a fixed fuel mass flow rate. Furthermore, the investigation revealed that the discharge coefficient obtained by applying the exit pressure instead of the ambient pressure did exhibit no decrease, but rather was maintained at a nearly constant value, comparable to its level below the boiling point.
본 연구는 소양강댐 유역을 대상으로 LSTM 기반의 일유출량 추정 딥러닝 모형을 개발한 후, 모형구조 및 입력자료의 다양한 조합에 대한 모형의 정확도를 살폈다. 첫 12년(1997.1.1-2008.12.31) 동안의 유역평균 일강수량, 일기온, 일풍속 (이상 입력), 일평균 유량 (출력)으로 이루어진 데이터베이스를 기반으로 모형을 구축하였으며, 이후 12년(2009.1.1-2020.12.31) 동안의 자료를 사용하여 Nash-Sutcliffe Model Efficiency Coefficient (NSE)와 RMSE를 살폈다. 가장 높은 정확도를 보인 조합은 64개의 은닉유닛을 가진 LSTM 모형 구조에 가능한 모든 입력자료(12년치의 일강수량, 일기온, 일풍속)를 활용한 경우로서 검증기간의 NSE와 RMSE는 각각 0.862와 76.8 m3/s를 기록하였다. LSTM의 은닉유닛이500개를 초과하는 경우 과적합으로 인한 모형의 성능 저하가 나타나기 시작했으며, 1000개를 초과하는 경우 과적합 문제가 두드러졌다. 12년치의 일강수만 입력자료로 활용한 경우에도 매우 높은 성능(NSE=0.8~0.84)의 모형이 구축되었으며, 한 해의 자료만을 활용하여 학습한 경우에도 충분히 활용 가능한 정확도(NSE=0.63~0.85)를 가진 모형을 구축할 수 있었다. 특히 유량의 변동성이 큰 한 해의 자료만을 활용하여 모형을 학습한 경우 매우 높은 정확도(NSE=0.85)의 모형이 구축되었다. 학습자료가 중유량과 양극한의 유량을 모두 포함한 경우라면 5년 이상의 입력자료는 모형의 성능을 크게 개선시키지 못했다.
본 논문은 압축기 인버터 주파수 제어에 따른 CO2용 수냉식 열펌프의 성능 특성에 대해서 실험적으로 조사하였다. 실험장치는 압축기, 가스냉각기, 팽창밸브, 증발기, 내부 열교환기, 수액기로 구성된다. 실험장치에 사용된 모든 열교환기는 동관으로 제작된 이중관식 대향류형이다. 가스냉각기와 증발기는 2.4 m인 소시험부 6개와 4개로 각각 구성된다. 실험결과를 요약하면, 우선 증발기와 가스냉각기의 입구온도와 냉매유량이 일정한 조건하에서 압축기 인버터 주파수가 증가할수록 압축비와 토출압력이 증가한다. 또한 인버터 주파수가 증가할수록 난방능력과 압축일량은 증가하는 반면 성능계수는 감소한다. 그리고 증발기 입구 2차유체의 온도가 $15^{\circ}C$에서 $25^{\circ}C$로 증가함에 따라 압축비와 압축일량은 감소하지만 질량유량, 난방능력, 성능계수는 증가한다. 위의 이러한 경향은 종래의 프레온계 냉매 시스템의 성능 변화와 유사하다.
낙동강 중${\cdot}$하류수역에서 1997년 1월부터 1999년 12월사이 3년간의 수온, Chl. a, 유량변동을 모니터링하였다. 유량별 Chl. a 지점별 분포는 강수량에 따른 하천유량의 증감으로 인해 Chl. a 최대농도지점이 상${\cdot}$하류로 이동하였고, 수온별 Chl. a 의 최대농도 분포 역시 수온변화에 따라 상${\cdot}$하류로 이동하여 하천유속과 수온이식물플랑크톤 최대현존량(Chl. a)지점 형성에 큰 영향을 미치는 것으로 나타났다. 하천유하시간을 이용하여 식물플랑크톤 최대성장시간을 수온별로 구분한 결과 저수온시에는 평균적으로 380시간, 상온시는 240시간, 고수온시는 120시간 정도에서 최고농도에 이르는 것으로 나타났다. 낙동강 중 ${\cdot}$하류수역에서 식물플랑크톤 농도 예측을 위한 수온별 성장 및 사멸계수는 $10{\circ}^C$ 이하에서는 0.201과 $-0.012\; day^{-1}$, $10{\sim}20{\circ}^C$에서는 0.254와 $-0.128\;day^{-1}$ 그리고 $20{\circ}^C$ 이상에서는 0.289와 $-0.193\;day^{-1}$로 각각 산정되었다. 이러한 결과로부터 영양염 공급이 풍부한 낙동강 중 ${\cdot}$ 하류수계에서는 식물플랑크톤의 최대농도 지점이 수온과 유속에 크게 영향을 받으며, 따라서 상수원과 같은 특정지점에서 식물플랑크톤의 최대현존량이 형성되는 것을 막기 위해서는 댐 방류량 조절을 통해 최대현존량지점을 상 ${\cdot}$ 하류지역으로 이동시킴으로서 식물플랑크톤 농도를 줄이는 효과를 얻을 수 있을 것으로 추정된다.
본 연구에서는 산화구 방법으로 하수처리를 하는 공공 하수처리장을 선정하여 통계적인 방법으로 처리장의 수질 및 운영의 효율을 분석하였다. 얻어진 수질 데이터는 유입수 및 배출수의 pH, 온도, BOD, SS, T-N, ${NH_4}^+-N$ 및 T-P였다. 데이터 분석은 군집분석, 상관분석, ANOVA 분석, 클러스터 분석으로 수행되었다. 통계분석 결과, 하수 처리장의 유입 유량은 여름에 가장 높았으며 평균 유속은 $3.000m^3/s$이었다. Box plot 결과에 따르면, 하수의 COD, 총인 농도는 계절에 변화에 따라 크게 차이가 없었다. Pearson 상관관계 분석결과는 유입수에서 BOD, COD, T-N 및 T-P 간에 강한 양의 상관관계를 보였다. 계절변화에 따른 BOD와 T-N 농도는 겨울철에 가장 높았고, 계절에 따른 온도의 영향은 COD와 T-P가 가장 높았다. BOD는 수온과 음의 상관관계를 보였으나 HRT, SRT, C/N과 같은 공정인자는 양의 상관관계를 나타내었다. 유입수 온도가 높을수록 BOD 농도가 낮아지는 현상을 보였으며, 체류 시간이 단축될수록 BOD의 처리 효율이 저하되었다. T-N은 효율적인 처리를 위해 긴 체류 시간이 필요했으나 T-P는 공정인자의 변화에 따른 상관관계도에서 다소 적게 나타났다.
본 연구에서는 기후변화에 따른 메콩강 유출변화 분석을 목적으로 하고 있다. HadGEM3-RA로 부터 생산된 동아시아 지역 RCP 4.5 및 8.5 시나리오의 일 자료를 기반으로 편의보정을 통해 미래 기후변화 시나리오를 구축한 후, SWAT 모형을 이용하여 메콩강 주요지점인 Kratie(유역면적: $646,000km^2$, 메콩강의 연평균 유량의 88%)에서의 유출변화 모의하고 유황분석을 수행하였다. 기후변화 분석 결과 Kratie 유역의 미래 강수량은 기준 년 연평균 강수량 대비 미래 년 기간의 연평균 강수량은 두 시나리오 모두 증가하는 것으로 분석되었으며 월별 강수량 변화 분석을 통해 6월~11월에 강수량의 증가가 비교적 크게 나타나며 특히 RCP 8.5 시나리오에서 강수량의 변동 폭 및 증가량이 크게 나타남을 확인하였다. 시나리오별 월평균 최대 및 최소기온의 변화는 두 시나리오 모두 미래 기온의 상승을 전망하고 있으며 특히 RCP 8.5 시나리오의 온도증가 폭이 크게 나타나는 것을 확인 하였다. 또한 하천유황변화 분석결과 유역의 유량변동성이 더욱 커질 것으로 분석되었으며 저수계수 값이 52~57% 감소하고 갈수계수 값이 67~74% 감소하는 것으로 나타나 하천의 갈수상황이 지속되어 미래에 가뭄이 보다 심화될 것으로 분석되었다.
호수지역에서, 호수의 위치가 지하수 flux에 미치는 영향을 파악하고 지하수와 호소수와의 교류관계를 관측하기 위한 감시망 설계에 대한 지침을 제공하기 위하여 호수의 위치를 달리하는 3종류의 가상 지하수 시스템을 설계하였다. 각각의 지하수 시스템에 대하여 3차원정상 모의발생을 행하였으며 다음과 같은 결과를 얻었다: (1) 호수의 위치가 지하수 시스템의 상류측에 위치할 때 보다 하류측에 위치하는 경우가 호소수와 지하수와의 고류가 활발하다. (2) 대상지역의 호수는 존재하는 위치에 상관없이 지하수가 호수로 유출되는 양보다 호소수가 지하수를 함양하는 양이 많다. (3) 호수의 위치가 유역의 상류층에 위치 할수록 지하수 유출입량의 비가 커진다. (4) 호수의 바닥부분에서 지하수의 수평방향 flux에 의한 교류는 연직방향 flux에 의한 교류 보다 훨씬 더 활발하다.
Journal of Advanced Marine Engineering and Technology
/
제32권6호
/
pp.869-876
/
2008
A thermocompressor is the equipment which compresses a vapor to a desired discharge pressure. Since it was first used as the evacuation pump for a surface condenser, it has been widely adopted for energy saving systems due to its high working confidence. In the present study, the geometrical analysis of the shape between the jet nozzle and the diffuser inlet, the drag force was calculated by means of the integrated equation of motion and the computational fluid dynamic (CFD) package called FLUENT. The computer simulations were performed to investigate the effects by the various suction flow rates, the distance from jet nozzle outlet to the diffuser inlet and the dimensions of the diffuser inlet section through the iterative calculation. In addition, the results from the CFD analysis on the thermocompressor and the experiments were compared for the verification of the CFD results. In the case of a jet nozzle, the results from the CFD analysis showed a good agreement with the experimental results. Furthermore, in this study, a special attention was paid on the performance of the thermocompressor by varying the diffuser convergence angle of $0.0^{\circ}$, $0.5^{\circ}$, $1.0^{\circ}$, $2.0^{\circ}$, $3.5^{\circ}$ and $4.5^{\circ}$. With the increase of the diffuser convergence angle. the suction capacity was improved up to the degree of $1.0^{\circ}$ while it was decreased over the degree of $1.0^{\circ}$.
Experimental data are reported for charging and collection of NaCl aerosols in the 0.03- to $0.2{\mu}m$-geometric-mean-diameter range in 2-stage parallel-plate electrostatic precipitators. The NaCl aerosols are generated with geometric standard deviation of about 1.74 and particle generation rate of about 10^9 particles/see by the constant output atomizer and injected into the air flow in the clean wind-tunnel. The 2-stage parallel-plate electrostatic precipitator installed in the test section of the wind-tunnel is operated with a positive corona discharge. The NaCl aerosols in the channel flow are sampled and transported to the aerosol particle number concentration measurement system by using the isoaxial sampling and transport system constructed based on the Okazaki and Willeke design. The aerosol particle number concentration measurement system measures the size distribution of submicrometer aerosols by an electrical mobility detection technique. It is confirmed from comparing the measured collection efficiencies in this study and the predicted ones by our previous theoretical analysis that the predicted collection efficiencies agree well with the experimental ones. It is also found from the comparison that below about $0.02{\mu}m$ all particles are not charged and the uncharged particles are not collected, and consequently 2-stage parallel-plate electrostatic precipitators are not suitable for that particle size range.
The concentration of atmospheric carbon dioxide (CO2), which is one of the major greenhouse gases, continues to rise with the increase in fossil fuel consumption. In order to mitigate global warming the amount of CO2 discharge to the atmosphere must be reduced. Carbon dioxide capture and storage (CCS) technology is now regarded as one of the most promising options. To complete the carbon cycle in a CCS system, a huge amount of captured CO2 from major point sources such as power plantsshould be transported for storage into the marine or ground geological structures. Since 2005, we have developed technologies for marine geological storage of CO2,including possible storage site surveys and basic design of CO2 transport and storage process. In this paper, the design parameters which will be useful to construct on-shore and off-shore CO2 transport systems are deduced and analyzed. To carry out this parametric study, we suggested variations in thedesign parameters such as flow rate, diameter, temperature and pressure, based on a hypothetical scenario. We also studied the fluid flow behavior and thermal characteristics in a pipeline transport system.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.