• Title/Summary/Keyword: discharge flow rate

Search Result 755, Processing Time 0.032 seconds

Monitoring the Growth of Juvenile Chum Salmon (Oncorhynchus keta) Released to Taehwa River of Korea (태화강 내 연어(Oncorhynchus keta) 치어의 방류에 따른 성장 모니터링)

  • Hur, Jun Wook;Yoon, Ji Woo;Lim, Han Kyu
    • Journal of Marine Life Science
    • /
    • v.6 no.2
    • /
    • pp.106-116
    • /
    • 2021
  • To secure basic data by monitoring the growth of salmon (Oncorhynchus keta) released to the Taehwa River. After discharge, the characteristics of the young salmon distribution and migration rate habitat were investigated for two years. A total of 4 points [Sunbawi bridge (St.1), Guyeong bridge (St.2), Samho bridge (St.3), and Myeongchon bridge (St.4)] were investigated. The survey of 2017 indicating an increase of 10 mm in average length and 0.8 g in average weight, and the survey of 2018 indicating an increase of 10 mm in average length and 0.5 g in average weight. Among 39 species, 10 insectivorous and 12 omnivorous, are believed to compete with young salmon for food. 6, 5, 6 and 8 predatory fish species has emerged at each site, respectively. According to this study, it is believed that St.1 and St.2 points are more proper as discharge location of young salmon because these two points have less varied in depth, flow rate, salt concentration etc. In addition, it is thought that the night or dawn time in early January is the best discharge time of young salmon fish because predatory fish such as Korean piscivorous chub and bass etc. does not eat food actively at that time.

Development of a constant pressure feed system using a constant pressure proportional control mode (정압비례제어방식을 적용한 정압급수장치의 개발)

  • 김주명;김광열;이건기
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.1026-1031
    • /
    • 2003
  • Automatic feed pumps are operated and stopped by a pressure switch. Thus, because of repeated operations and stops of the pumps according to fluctuations of water volume, operation with constant rate and pressure is impossible. Moreover, because of repeated running of the pump, keeping up of constant pressure is impossible and damage and energy loss are weak points of the pimps. To make up for defects of an automatic feed pump, this paper designed and made a static pressure feed system which was composed of a feed water control valve, a flow sensor and a control system. The valve device plays an important part in reducing load of pumps by constant water supply regardless of outflow of water. Outflow of water is determined by infrared diode of the flow sensor. The control system is made of a 8 bit micro-processor and the pump was controled by a specific control algorithm. With the constant pressure feed system, discharge pressure was kept at fixed pressure, accurate operations and stops were smoothly accomplished and the pump was operated with constant pressure. Thus, the constant pressure feed system can be considered as an advanced system which made up for the weak points in the current automatic feed systems.

An Experimental Study on Characteristics of Droplet Generation by Electrospraying for Highly Viscous Liquids (정전분무에 의한 고점성 액체의 액적 생성 특성에 관한 실험적 연구)

  • Kim, Sang-Su;Gu, Bon-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.4
    • /
    • pp.604-613
    • /
    • 2002
  • Generation characteristics of electrospray droplets for highly viscous liquid have been investigated by measuring size distributions of droplets emitted from the Taylor cone using glycerol solutions with various conductivities. Because of very small volatility of glycerol, droplet sizes can be measured by an aerodynamic size spectrometer (TSI Aerosizer DSP) with negligible evaporation of droplets. For highly conducting and viscous liquid, the sizes of the droplets electrosprayed from the Taylor cone are found to be relatively insensitive to applied voltages and the electrosprays assisted by the corona discharge call produce monodisperse droplets as long as the corona intensity is not too high. Near the minimum flow rate where a liquid cone is stable, the spray tends to consist of a one -peak monodisperse distribution of drop lets. However, at high flow rates, the spray bifurcates into bimodal distributions, which are consistent with the result of the previous study for less viscous liquids than our liquids. For liquid flow rates (Q) below 1 nl/s, the measured droplet diameters by the aerosizer are in the range of 0.30 to 1.2 ${\mu}{\textrm}{m}$ for the glycerol solutions. The diameters of monodisperse droplets scale approximately with $r^*=Q_$\tau$(Q$\tau$){^1/3}$ where $r^*$ is a characteristic length and $\tau$is the electrical relaxation time of the fluid. However, when compared with several represe ntative scaling laws, the droplet diameters are two to six factors greater than those predicted by the scaling laws. This may be closely related to the combined effect of the much higher viscosity and the electrical charge on the jet breakup of glycerol so solution.

Analysis of Velocity Structure of Round Wall Jet (원형바닥젵의 유속구조 해석)

  • Kim, Dae-Geun;Seo, Il-Won
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.5
    • /
    • pp.467-475
    • /
    • 1997
  • In this study, breakwater model which has several outlet pipes to discharge heated water is settled in the experimental open channel and velocity distribution of wall jet is measured. Numerical simulation of velocity structure of wall jet using 3-dimensional computer model. Fluent model, is also carried out. The calculated results are verified with the experimental results and the flow characteristics of wall jet are investigated. The length of zone of flow establishment of wall jet is shorter than that of free jet, and the diminution rate of jet centerline longitudinal velocity is larger than that of free jet. Characteristics of buoyant jet and non-buoyant simple jet simulated by Fluent model are compared. Near the outlet pipe, in the region where x/lQ is over 15, this is reversed. Comparison of vertical distribution of longitudinal velocity shows that positive velocity of non-buoyant jet is bigger than that of buoyant jet in the bottom layer and in the upper layer, negative velocity of non-buoyant jet is bigger too. Flow separation in free surface of the buoyant jet occurs in smaller distances from the outlet than the non-buoyant jet. Buoyant jet expands faster than the non-buoyant jet in vertical direction.

  • PDF

Numerical Analysis on the Cavitation Performance of a Seawater Cooling Pump (해수냉각 펌프의 캐비테이션 성능에 대한 수치해석)

  • Tran, Bao Ngoc;Kim, Jun-ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.1
    • /
    • pp.130-137
    • /
    • 2019
  • In this study, a centrifugal seawater cooling pump was analyzed to investigate its cavitation behavior over different operating flow rates. 3D two-phase simulations were carried out with ANSYS-CFX commercial code. The $k-{\varepsilon}$ turbulence and Rayleigh-Plesset cavitation models were employed in the simulations. A head drop characteristics curves for three discharge rates was built based on numerical predictions. At higher flow rates, the impeller was more vulnerable to bubble cavitation. The 3 % head drop points of the pump working at 0.7Q, Q, and 1.3Q (Q: design flow rate) corresponded with NPSHa 1.21 m, 1.83 m, and 3.45 m, respectively. The volume of vapor bubbles was estimated and cavitation locations were anticipated to visualize the development of the cavity within the impeller. Moreover, the distribution of pressure coefficient and a blade loading chart are specifically presented, bringing out the harmful impacts of cavitation on the pump operation.

Differences in Treatment Outcomes According to the Insertion Method Used in Extracorporeal Cardiopulmonary Resuscitation: A Single-Center Experience

  • Han Sol Lee;Chul Ho Lee;Jae Seok Jang;Jun Woo Cho;Yun-Ho Jeon
    • Journal of Chest Surgery
    • /
    • v.57 no.3
    • /
    • pp.281-288
    • /
    • 2024
  • Background: Venoarterial extracorporeal membrane oxygenation (ECMO) is a key treatment method used with patients in cardiac arrest who do not respond to medical treatment. A critical step in initiating therapy is the insertion of ECMO cannulas. Peripheral ECMO cannulation methods have been preferred for extracorporeal cardiopulmonary resuscitation (ECPR). Methods: Patients who underwent ECPR at Daegu Catholic University Medical Center between January 2017 and May 2023 were included in this study. We analyzed the impact of 2 different peripheral cannulation strategies (surgical cutdown vs. percutaneous cannulation) on various factors, including survival rate. Results: Among the 99 patients included in this study, 66 underwent surgical cutdown, and 33 underwent percutaneous insertion. The survival to discharge rates were 36.4% for the surgical cutdown group and 30.3% for the percutaneous group (p=0.708). The ECMO insertion times were 21.3 minutes for the surgical cutdown group and 10.3 minutes for the percutaneous group (p<0.001). The factors associated with overall mortality included a shorter low-flow time (hazard ratio [HR], 1.045; 95% confidence interval [CI], 1.019-1.071; p=0.001) and whether return of spontaneous circulation was achieved (HR, 0.317; 95% CI, 0.127-0.787; p=0.013). Low-flow time was defined as the time from the start of cardiopulmonary resuscitation to the completion of ECMO cannula insertion. Conclusion: No statistically significant difference in in-hospital mortality was observed between the surgical and percutaneous groups. However, regardless of the chosen cannulation strategy, reducing ECMO cannulation time was beneficial, as a shorter low-flow time was associated with significant benefits in terms of survival.

Catalystic effect of Sludge on $NO_x$ removal in Packed bed reactor (Packed bed형 반응기에서 $NO_x$ 제거에 미치는 슬러지의 촉매효과)

  • Park, Jae-Yoon;Lee, Dong-Hoon;Koh, Hee-Suk;Jung, Jang-Gun;Bae, Myung-Whan;Kim, Jong-Dal
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1780-1782
    • /
    • 2001
  • In this experiment, an attempt to use the sludge pellets as catalyst for NO removal from simulated gas is experimentally investigated by using $BaTiO_3$-sludge packed-bed reactor of plate-plate geometry. An experimental investigation has been conducted for NO concentration of 50[ppm] balanced with air, a gas flow rate of 5[1/min]. $BaTiO_3$ pellets are filled at upstream of reactor for corona discharge and sludge pellets are put at downstream of reactor for catalystic effect. The volume rate of sludge pellets to $BaTiO_3$ pellets is 50[%] and AC voltage to dischare the gases was supplied. In the result, when sludge pellets is seperated to $BaTiO_3$ by other reactor and AC voltage is supplied to $BaTiO_3$ and sludge pellets NO, $NO_2$ removal rate is higher. When gas temperature increase from room temperature to 100[$^{\circ}C$], NO removal is decreased while $NO_2$ concentration is independent on gas temperature. This result suggest that the removal mechanism of active oxyzen species and $NO_2$ in sludge is not absorption, but chemical reaction. Temperature of heating treatment is on sludge pellets increased, $NO_x$ removal rate is decrease. It is thought that organic compound is removed by heating treatment.

  • PDF

Characterization Tests on the SIT Injection Capability of the ATLAS for an APR1400 Simulation (APR1400 모의를 위한 ATLAS 안전주입탱크의 주입 성능에 관한 특성 시험)

  • Park, Hyun-Sik;Choi, Nam-Hyun;Park, Choon-Kyung;Kim, Yeon-Sik
    • Journal of Energy Engineering
    • /
    • v.17 no.2
    • /
    • pp.67-76
    • /
    • 2008
  • A thermal-hydraulic integral effect test facility, ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation), has been constructed at KAERI (Korea Atomic Energy Research Institute). Recently several integral effect tests for the reflood period of a LBLOCA (Large Break LOss of Coolant Accident) of the APR1400 have been performed with the ATLAS. In the APR1400 a high flow condition is changed to a low flow condition due to an fluidic device during an operation of the SIT. As the self-controlled fluidic device was not installed in the ATLAS, a set of characterization tests was performed to simulate its injection capability from the SIT for the APR1400 simulation. In the ATLAS the required SIT flow rate in the high flow condition was acquired by installing orifices with an optimized flow area to throttle the SIT discharge line and the low flow condition was achieved by changing the opening of the flow control valve in the SIT injection line. The test results showed that the safety injection systems of the ATLAS could simulate the required high and low flow rates of the SIT for the APR1400 simulation efficiently.

Groundwater Flow Modeling and Suggestion for Pumping Rate Restriction around K-1 Oil Stockpiling Base with Geological Consideration (지질조건을 고려한 K-1 비축기지 주변의 지하수 모델링과 양수량 제한구역 제안)

  • Moon, Sang-Ho;Kim, Kue-Young;Ha, Kyoo-Chul;Kim, Young-Seog;Won, Chong-Ho;Lee, Jin-Yong
    • The Journal of Engineering Geology
    • /
    • v.20 no.2
    • /
    • pp.169-181
    • /
    • 2010
  • This study aimed at simulating several responses to stresses caused by the ground water level variations around the K-1 oil stockpile. For this simulation, we considered the characteristic hydrogeological condition including the special occurrence of long and thick acidic dyke, which is regarded as the main geological structure dominating the ground water flow system at this study area. We activated twenty-four imaginary wells which are located in northern and southern area around central K-1 site. Each neighboring distance is altogether 300 m and whole distance between K-1 site and remote wells is 1,200 m. Through the modeling, we operated the long-term and continuous pumping tests and finally categorized five zones based on maximum pumping rates for the imaginary wells; zone I within 300 meter distance from K-1 site with a pumping rate of 50 $m^3/day$; zone II between 300 to 600 meter distance from K-1 site with a pumping rate of 75 $m^3/day$; zone III between 600 to 900 meter distance from K-1 site with 150 $m^3/day$; zone IV between 900 to 1,200 meter distance from K-1 site with 300 $m^3/day$; and zone V of acidic dyke area. At zone V, especially because of their possibility of high transmissivity for groundwater flow, it is necessary to control and restrict groundwater discharge.

Evaluation of Field Feasibility and Efficiency of Hydraulic Ram Pump (수격펌프의 효율성 및 현장 적용성 평가)

  • Lee, Soo-Hyoung;Yoon, Heesung;Kim, Dong-Hun;Shin, Esther;Kim, YongCheol;Ko, Kyung-Seok;Ha, Kyoochul
    • Economic and Environmental Geology
    • /
    • v.49 no.3
    • /
    • pp.243-248
    • /
    • 2016
  • This study was conducted to evaluate the applicability and efficiency of water supply using hydraulic ram pump. Study area is the Imgok-ri, Hwanam-myeon, Sanju-si, Kyeongsangbuk-do. There is an abandoned coal mine, where groundwater is discharged from its entrance with a flow rate of approximately $260m^3/day$. Hydraulic ram pump uses the waterhammer phenomenon and utilizes the power of falling water for pumping part of that water to a higher elevation than the water sources without electric power. To determine the efficiency of hydraulic ram pump, the flow rate was measured at three points according to the altitude difference (${\Delta}h=19m$ (point 1), 30 m (point 2), 40 m (point 3)). Flow rate measured at 1, 2, and 3 were about $8.6{\sim}10.8m^3/day$, $3.98{\sim}4.39m^3/day$, and $2.35{\sim}2.59m^3/day$, respectively. The current results suggested that, hydraulic ram pump could be applicable for the water supply system in mountain areas without external power supply.