A study on the estimation of TMDL run-off pathway coefficients for livestock resources (축분자원화물의 총량관리지침 배출구조계수 산정에 관한 연구)

  • Han, Gee-Bong;Lee, Young-Sin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.3
    • /
    • pp.99-107
    • /
    • 2013
  • In this study, field scale test was conducted to estimate the TMDL coefficients (runoff and leachate:(${\beta}4$)(${\beta}5$)(${\beta}8$)) for the livestock resources applying to agricultural crop land as fertilizer, and the results were obtained as follows. Each waste reduction coefficient(${\beta}4$) was shown to be in the range of 0.94~0.75 for public waste treatment plants and 0.99~0.83 for private waste treatment in the analysis of BOD, COD, SS, T-N, T-P, TOC. Thus private plants showed higher rate. Waste treatment discharge into the land coefficient (${\beta}5$) was also shown to be in the range of 0.4.~0.24 for public plants and 0.75~0.16 for private plants, so it is much lower than other coefficients. However SS and T-P were shown to be much higher for land discharge in private plants than in public plants. Treatment coefficient in the public plants (${\beta}8$) appeared to be average 0.75 for T-P but over 90% treatment efficiency and also large deviation were observed due to 0.2 of some other treatment plants.

A Study on the Reliability of In-hospital Patient Death Information in Health Insurance Claims: Acute Myocardial Infarction and Coronary Artery Bypass Graft Patients (요양급여 명세서 (병원내) 사망정보의 신뢰성분석 : 급성심근경색증과 관상간우회로조성술 환자를 대상으로)

  • Lee, Kwang-Soo;Lee, Sang-Il
    • Health Policy and Management
    • /
    • v.16 no.3
    • /
    • pp.37-51
    • /
    • 2006
  • This study evaluates the reliability of the discharge status variable m health insurance claims for identifying in-hospital patient deaths. This study used 2002 national health insurance claims and the cause of death statistics from Korean national statistical office. The Study data set included acute myocardial infarction (AMI) and coronary artery bypass graft (CABG) surgery patients in 133 general and tertiary hospitals. The gold standard containing patient death information was made and then compared with that of claims data. The hospitals were classified into four groups based on the number of deaths in each hospital. Simple kappa coefficients were calculated to evaluate the agreements of patient deaths between the gold standard and the insurance claims. CABG (83.9%) showed higher agreements than AMI(73.0%) in matched in-hospital patient death information between data sets. Simple kappa coefficients of CABG (0.63) and AMI (0.59) showed moderate or good agreements. The agreements, however, varied depending on the disease or hospital types. The fact that the agreements are only moderate to good indicates that the accuracy of in-hospital death information in claims is not high. n the variable is used to identify patient deaths, it may mislead people. Therefore, efforts should be made to improve the reliability of the discharge status variable in health insurance claims.

Evaluation of Residential Radiation Doses from Korean Atomic Power Plants - Effect of Socioenvironmental Inputs (국내 원전주변 주민 방사선 피폭선량 평가 - 입력변수의 영향)

  • 조대철;이갑복
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.223-229
    • /
    • 2003
  • Annual radiation dose of residential individuals near 4 nuclear power plants in Korea was calculated via K-DOSE 60 based on the updated ICRP-60. The critical exposure variables were chosen as radionuclides, exposed organs and intake pathways. From the calculation results, the critical nuclides were found to be $^3$H, $^{133}$ Xe, $^{60}$ Co for Kori plants and $^{14}$ C, $^{41}$ Ar for Wolsung plants. The most critical pathway was 'vegetable intake' for adults and 'milk intake' for infants. However, there was no preference in the effective organs. Sensitivity analyses showed that the chemical composition in a nuclide much more influenced upon the radiation dose than any other input parameters such as food intake, radiation discharge, and transfer/concentration coefficients by more than 10$^2$ factor. The effect of transfer/concentration coefficients on the radiation dose was negligible. All input parameters showed highly estimated correlation with the radiation dose, approxinated to 1.0.

  • PDF

Adaptability Analysis of Granule Fertilizer Applicator for Rapeseed Broadcasting (입제 비료살포기의 유채 파종 적용성 분석)

  • Lee, C.K.;Choi, Y.;Jun, H.J.;Lee, C.S.;Kim, Y.J.;Lee, S.K.;Oh, S.H.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.2
    • /
    • pp.106-113
    • /
    • 2009
  • This study was carried out to test feasibility of a granule fertilizer applicator for rapeseed seeding in paddy fields. The metering plate of a conventional applicator was modified for rapeseed seeding. The modified plate had new three seeding openings with total area of $342mm^2$. Average target discharging rates ranged from 6.3 to 21.0 g/s and correlated with opening areas. Application patterns of the rapeseed seeding showed M-shape. The coefficients of variation of the application showed 70.5% at 0.99 m/s of forwarding speed and 14.3 g/s of a discharge rate, and 77.7% at 1.72 m/s of a forwarding speed and 8.23 g/s of a discharge rate. The coefficients of variation in the direction of transverse of the tractor ranged from 7.3 to 47.7%. In rapeseed seeding tests using the applicator, seed damages rates were less than 15% due to the agitator, the seed hopper and the seeding plate break. Therefore, improvements of the applicator blow heads and seeding equipments were required in order to apply rapeseed efficiently.

Analysis of Flow Duration Characteristics due to Environmental Change in Korea River Basin (우리나라 하천유역 환경변화가 유황특성에 미치는 영향 분석)

  • Lee, Jae-Joon;Kim, Young-Jun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.67-75
    • /
    • 2011
  • The purpose of this study is to evaluate the flow duration characteristics of Nakdong, Seomjin and Geum river due to environmental change. The water level gauging stations of Nakdong, Seomjin and Geum river were selected to analyze the change of flow duration. The construction period of multipurpose dam was considered to analyze flow duration characteristics. As the result of this study, it show that ninety-five day flow, normal flow, low flow and drought flow were increased by multipurpose dam construction at all stations except a Jukpo gauging station. Especially, improved effect of flow duration in downstream part was bigger than that in upstream and midstream part. The coefficients of river regime of Nakdong, Seomjin and Geum river were decreased and also coefficients of flow duration were decreased after the multipurpose dam construction. However decline of coefficient of flow duration was smaller than coefficient of river regime because coefficient of flow duration is less affected by maximum discharge and minimum discharge than coefficient of river regime, It was confirmed that multipurpose dam on upstream and midstream has a useful effect for improving the flow duration characteristics.

A Study on the Estimation of Discharge Coefficients with Variations of Side Weir Angle (횡월류 위어 유입각 변화에 따른 유량계수 추정 기초 연구)

  • Wan-Seop Pi;Hyung-Joon Chang;Kye-Won Jun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.1
    • /
    • pp.81-89
    • /
    • 2023
  • Recently, due to global warming and urbanization due to the influence of abnormal weather, weather changes are increasing worldwide. Various measures have been proposed to reduce flood damage as flood volume increases due to problems such as an increase in impermeable area due to urbanization and reckless development. In this study, flow characteristics and overflow volume were analyzed using FLOW-3D, a three-dimensional CFD model, in accordance with changes in the cross-flow weir inlet angle installed in the meandering river section, and a basic study was conducted to evaluate the overflow capacity and calculate the flow coefficient. As a result of the analysis, the smaller the inflow angle of the transverse overflow, the lower the water level and flow rate of the main water flow after passing the transverse overflow, and the higher the inflow angle, the higher the water level and the flow rate. In addition, it was confirmed that the direct downstream flow rate decreased compared to the upstream flow rate when the inflow angle of the transverse overflow was 40° or higher.

Study on Estimation for Discharge Coefficient of Diagonal Weir (경사 위어의 유량계수 산정에 대한 연구)

  • Im, Jang-Hyuk;Jin, Sin-Wook;Song, Jai-Woo
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.5
    • /
    • pp.375-383
    • /
    • 2009
  • This study examined hydraulic characteristics on diagonal weirs with hydraulic experiment and presented a discharge coefficient equation utilizing multiple regression analysis for various design conditions. This study had a object in designing efficiently diagonal weirs utilizing this equation. Diagonal weirs maintained uniformly upstream water level than rectangular suppressed weirs. Also, as installation degrees of diagonal weirs increased, diagonal weirs increased maintenance effects of a upstream water level. Because of these characteristics, diagonal weirs were suitable to canal system. This study presented discharge coefficient equations for diagonal weirs utilizing simple regression analysis. But, these equations are some restrictions on degrees. Therefore, this study presented an equation to estimate directly discharge coefficients to various degrees utilizing multiple regression analysis. This equation was verified by making use of analyses of $R^2$, the sum of residuals, MAPE. Therefore, this equation is enable to make good use of a design in diagonal weirs.

Effect Of Substituted-Fe for the Charge-discharge behavior Of $LiMn_{2}O_{4}$cathode materials (Fe 치환이$LiMn_{2}O_{4}$정극 활물질의 충방전 특성에 미치는 영향)

  • 정인성;김민성;구할본;손명모;이헌수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.548-551
    • /
    • 2000
  • Spinel phase LiF $e_{y}$M $n_{2-y}$ $O_4$samples are synthesized by calcining a LiOH.$H_2O$, Mn $O_2$and F $e_2$ $O_3$mixture at 80$0^{\circ}C$ for 36h in air. Preparing LiF $e_{y}$M $n_{2-y}$ $O_4$showed spinel phase with cubic phase. The ununiform distortion of the crystallite of the spinel LiF $e_{y}$M $n_{2-y}$ $O_4$was more stable than that of the pure. The discharge capacity of the cathode for the Li/LiF $e_{0.1}$M $n_{1.9}$ $O_4$cell at the first than that of the pure. The discharge capacity of the cathode for the Li/LiF $e_{0.1}$M $n_{1.9}$ $O_4$cell at the first cycle and at the 70th cycle was about 113 and 90mAh/g, respectively. This cell capacity was retained about 82% of the first cycle after 70th cycle. Impedance profile of this cell was more stable than that pure. The resistance, the capacitance and chemical diffusion coefficients of lithium ion showed approximately 80$\Omega$, 36133.87$\mu$F ; 1.4$\times$10$^{-8}$ c $m^2$ $s^{-1}$ , respectively. , respectively.ely.

  • PDF

Hospital-Acquired Pressure Injury: Clinical Characteristics and Outcomes in Critical Care

  • Hyun, Sookyung;Moffatt-Bruce, Susan;Newton, Cheryl;Hixon, Brenda
    • International Journal of Advanced Culture Technology
    • /
    • v.7 no.2
    • /
    • pp.28-33
    • /
    • 2019
  • Electronic health records (EHRs) enable us to use and re-use electronic data for various multiple purposes, such as public reporting, quality improvement, and patient outcomes research. Current hospital-acquired pressure injury (HAPI) risk assessment instruments have not been specifically developed for intensive care unit (ICU) patients and showed false positive rates in this specific populations. Previous research studies report a number of risk factors; however, it is still not clear what factors influence ICU HAPI in this population. As part of a larger research study, we performed an exploratory analysis by using a large electronic health record data. The aims of this study were to compare characteristics of patients who developed HAPIs during their ICU stay with those who did not, and to determine whether the two groups were different in the aspects of length of ICU stay, discharge disposition, and discharge destinations. We conducted chi-square test and t-test for group comparison. Association was examined by using bivariate analyses. Pearson correlation coefficients were used to examine correlation between LOS and number of medications. Our findings suggest a number of consistent and potentially modifiable risk factors, such as sedation, feeding tubes, and the number of medications administered. The mortality of the HAPI group was significantly higher than the non-HAPI group in our data. Discharge disposition was significantly different between the groups. 67% of the HAPI group transferred to intermediate or long-term care hospitals whereas 57.7% of the non-HAPI group went home after discharge. Awareness of these risk factors can lead to clinical interventions that can be preventative in the ICU setting.

Development of river discharge estimation scheme using Monte Carlo simulation and 1D numerical analysis model (Monte Carlo 모의 및 수치해석 모형을 활용한 하천 유량 추정기법의 개발)

  • Kang, Hansol;An, Hyunuk;Kim, Yeonsu;Hur, Youngteck;Noh, Joonwoo
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.4
    • /
    • pp.279-289
    • /
    • 2022
  • Since the frequency of heavy rainfall is increasing due to climate change, water levels in the river exceed past historical records. The rating-curve is to convert water level into flow dicscharge from the regression analysis of the water level and corresponding flow discharges. However, the rating-curve involves many uncertainties because of the limited data especially when observed water level exceed past historical water levels. In order to compensate for insufficient data and increase the accuracy of flow discharge data, this study estimates the flow discharge in the river computed mathematically using Monte Carlo simulation based on a 1D hydrodynamic numerical model. Based on the existing rating curve, a random combination of coefficients constituting the rating-curve creates a number of virtual rating curve. From the computed results of the hydrodynamic model, it is possible to estimate flow discharge which reproduces best fit to the observed water level. Based on the statistical evaluation of these samples, a method for mathematically estimating the water level and flow discharge of all cross sections is porposed. The proposed methodology is applied to the junction of Yochoen Stream in the Seomjin River. As a result, it is confirmed that the water level reproducibility was greatly improved. Also, the water level and flow discharge can be calculated mathematically when the proposed method is applied.