• Title/Summary/Keyword: disc-plate method

Search Result 44, Processing Time 0.027 seconds

A study on improvement of 2. 3. 5-Triphenyl Tetrazolium Chloride(TTC) reduction test : disc plate method (2. 3. 5-Triphenyl Terazolium Chloride(TTC) 환원시험법의 개선에 관한 연구 : disc plate method)

  • 정동수;김동훈;이상목
    • Korean Journal of Veterinary Service
    • /
    • v.18 no.2
    • /
    • pp.163-176
    • /
    • 1995
  • Triphenyl Tetrazolium Chloride(TCC) reduction test is simple and sensitive to some residual antibiotics (especially to penicillin) in milk, but comparatively insensible to sulfo-namides. The volumn of sample is also large. Thus this study was undertaken to increase the detectable level of sulfonamides in raw milk. In this study, we used small transparent plastic hole and pulp disc instead of 10m1 test tube and made test medium in which was added 0.08%TTC, 0.3% agar, 10% skim milk, approximately $10^6$ CFU/ml streptococcus thermophilus and 5ppm Trimethoprim to enhance the sensitivity for sulfonamides The results of TCC reduction test by disc plate method were summarized as follows : 1. sensitivity to residual sulfonamides were much higher than official TCC reduction test. Detectable limites of sulfamethazine, sulfamerazine, sulfathiazole, sulfachloropy-ridazine, sulfadimethoxine, sulfamononethoxine, sulfadiazine and sulfaquinoxaline were 0.1-0.5ppm levels. 2. Detectable limites to some antibiotics were simillar or good than that of official method as 0.005-0.1ppm to three ${\beta}$ -lactams, 0.25-0.5ppm to one macrolide, 2-10ppm to three aminoglycosides, 0.2-0.5ppm to three tetracycline, 0.1-0.5ppm to chloramphenicol. 3. Only 0.1ml of milk was needed to test and the test medium could be stored appnoximatly 7days in the refrigerator. So test procedure was convenient than offcial method. 4. These results suggest that disc plate method is more useful to detect bacterial growth inhibition substances including sulfonamides in raw milk.

  • PDF

New Technical Tip for Anterior Cervical Plating : Make Hole First and Choose the Proper Plate Size Later

  • Park, Jeong-Yoon;Zhang, Ho-Yeol;Oh, Min-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.4
    • /
    • pp.212-216
    • /
    • 2011
  • Objective : It is well known that plate-to-disc distance (POD) is closely related to adjacent-level ossification following anterior cervical plate placement. The study was undertaken to compare the outcomes of two different anterior cervical plating methods for degenerative cervical condition. Specifically, the new method involves making holes for plate screws first with an air drill and then choosing a plate size. The other method was standard, that is, decide on the plate size first, locate the plate on the anterior vertebral body, and then drilling the screw holes. Our hypothesis was that the new technical tip may increase POD as compared with the standard anterior cervical plating procedure. Methods : We retrospectively reviewed 49 patients who had a solid fusion after anterior cervical arthrodesis with a plate for the treatment of cervical disc degeneration. Twenty-three patients underwent the new anterior cervical plating technique (Group A) and 26 patients underwent the standard technique (Group B). POD and ratios between POD to anterior body heights (ABH) were measured using postoperative lateral radiographs. In addition, operating times and clinical results were reviewed in all cases. Results : The mean durations of follow-up were $16.42{\pm}5.99$ (Group A) and $19.83{\pm}6.71$ (Group B) months, range 12 to 35 months. Of these parameters mentioned above, cephalad POD (5.43 versus 3.46 mm, p=0.005) and cephalad POD/ABH (0.36 versus 0.23, p=0.004) were significantly greater in the Group A, whereas operation time for two segment arthrodesis (141.9 versus 170.6 minutes, p=0.047) was significantly lower in the Group A. There were no significant difference between the two groups in caudal POD (5.92 versus 5.06 mm), caudal POO/ABH (0.37 versus 0.32) and clinical results. Conclusion : The new anterior cervical plating method represents an improvement over the standard method in terms of cephalad plate-to-disc distance and operating time.

Robust Design of the Back-plate Shape of the Disc Brake Pad for Reduction of Uneven Wear (디스크 브레이크의 편마모 저감을 위한 브레이크 패드의 백플레이트 형상 강건설계)

  • Park, Jin-Tack;Han, Seung-Wook;Choi, Nak-Sam
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.1
    • /
    • pp.8-19
    • /
    • 2014
  • In this paper, a robust design of the back-plate of the brake pad to decrease the uneven wear of the pad was studied. A finite element analysis was performed to analyze the pressure distributions on the contact surfaces. Optimized back-plate shape of the brake pad was determined using the Taguchi method. The effectiveness of the robust design was clarified by the wear tests with a dynamometer.

Studies on the Antibiotic Constituents of Korean Basidiomycetes(IV). Preliminary examination of the mycelial cultures of the 17 basidiornycetous strains

  • Chung, Kyeong-Soo;Chung, Soo-Hyun;Kim, Byong-Kak
    • Archives of Pharmacal Research
    • /
    • v.11 no.1
    • /
    • pp.61-64
    • /
    • 1988
  • To investigate the antibiotic constituents of Korean basidiomycetes the carpophores of the wood-rotting basidiomycetes were collected from several locations of Korea, and from them 17 mycelial strains were isolated on potato-dextrose-agar plates supplemented with tetracycline ($20\;{\mu}g/m{\ell}$. The isolated strains were shake-cultured in glucosepeptone-yeast extract medium and then the antibacterial activities of the culture filtrates were assessed by disc-plate method. Among them, 12 strains (70.6%) were active, and basidiomycete strain LMCB-109 (Daedalea quercina) and LMCB-116 showed potent activities against all the six bacterial target organisms including Serratia marcescens.

  • PDF

Testing Evaluation for Stand-Alone Cervical Cage (경추용 자립형 케이지의 실험적 평가)

  • Baek, Myong-Hyun;Lee, Mun-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.11
    • /
    • pp.937-941
    • /
    • 2016
  • Stand-alone cervical cage consists of a PEEK body, Ti plate, and screw, which are configured as a single-piece. Through a single operation, this implantable medical device is capable of completely fixing the cervical vertebral body. For example, instead of a plate, which is normally used, the intervertebral disc is removed and replaced with a cervical cage. It should be noted that in Korea, KFDA guidelines for a stand-alone cervical cage have not yet been suggested. Therefore, the aim of this study is to present the systematic study of the static compression test, static torsion test, dynamic compression test, and expulsion test. Further, the test method is designed to refer to the ASTM standard and relative literature.

Age-related Geometric Effects on the Human Lumbar Spine by the Finite Element Method (유한 요소법을 이용한 나이에 따른 척추의 형상 및 구조변화의 효과)

  • Kim Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.285-293
    • /
    • 2000
  • Age-related changes in the geometry of human lumbar spine would lead to changes of its mechanical behaviors. To investigate the effects of the geometric changes, no age-related changes in the material/mechanical properties were considered. Using the finite element method. two age-related models of lumbar spine segments (L3-L4) were constructed. The annulus of the models was modeled as laminate composite elements with 16 layers and 6 materials. The spinal stiffness and facet reaction of the lumbar spine increased with the age-related geometric changes in various combined loadings. Fiber and transverse tensile strains of the inner annulus. cancellous bone stress and end-plate stress decreased with the age-related geometric changes whereas fiber/layer compressive strains of the annulus. facet reaction. ligament reaction and end-plate rigidity increased. Consequently, it appears that in the normal age-related deterioration of discs, the age-related geometric change contributes to the increase of spinal stiffness (the decrease in range of the motion segment), preventing an excessive deformation of the disc.

  • PDF

Economical Analysis of Cervical Disc Disease by Anterior Inter-body Fusion Methods - Comparing of Bone Graft vs Plating - (경추간판 탈출 환자의 전방 고정술에 따른 경제적 분석 - 골 이식법과 금속판 고정 병행술의 비교 -)

  • Gill, Seung-Bae;Lee, Sang-Youl;Heo, Seung-Ho;Jang, Yeun-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.201-206
    • /
    • 2001
  • Objective : The purpose of this study was to assess the complications, duration of admission, cost effectiveness, radiologic stabilization of the anterior cervical bone fusion in the treatment of cervical disc disease with and without plating. Materials and Methods : Fifty-two surgically treated patients for cervical disc disease were reviewed. Group I consisted of consecutive treated patients with iliac auto-bone graft without instrumentation after anterior cervical discectomy. Group II consisted of consecutive treated patients with iliac autologous-bone graft with CASPER cervical plate fixations. Radiologic fusion was decided when loss of end plate boundary between graft bone and vertebral body and immobile, maintenance of the disc space were evident on simple dynamic plain films. The patients were discharged after the stabilization of cervical motion by films was of tained. These groups were analysed multiple variably with Mann-Whitney U-test. Results : Group I consisted of 18 patients, group II consisted of 34 patients. Mean age was $49.0{\pm}8.1years$, mean duration of admission was $17.27{\pm}10.51days$, mean costs for treatment was $1,970,000{\pm}475,000won$. In group I, mean age was 47.7(34-60) years, 16 patients had undergo on one-level operation, 2-patients had undergo on two-level operation, mean duration of admission was $28.7{\pm}10.4days$, mean costs for treatment was $2,194,473{\pm}561,639won$. The periods of stabilization was $6.6{\pm}3.36weeks$ on radiologic study. Mean periods of out patient follow up was 16.8(6-64) weeks after discharge. Mean period of radiologic follow up was 17.3(4-6) weeks after surgical operation. In group II, mean age was 49.7(37-62) years and 18 patients one-level operation, 14- patients had undergo on two-level operation and 2-patients three-level operation. Mean duration of admission was $11.24{\pm}3.29days$, mean costs for treatment was $1,850,823{\pm}389,372won$. The periods of stabilization was $5.88{\pm}7.07weeks$ on radiologic study. Mean period of out patients follow up was 16.7(4-60) weeks after discharge. Mean period of radiologic follow up was 12.4(3-52) weeks after surgical operation. The duration of admission showed statistical significance in Group II but other items showed no significant difference between two groups. Conclusions : The more economic, early life return and effective method of cervical disc disease in our series were evident in patients who had undergone, iliac bone graft and plate fixations after anterior discectomy.

  • PDF

Application of Solidification Analysis considering Volumetric Contraction to Riser Design of Steel Castings (주강품 압탕 설계에 체적 수축을 고려한 응고해석의 적용)

  • Kim, Ji-Joon;Kim, Ki-Young;Choi, Jeong-Kil;Hong, Chun-Pyo
    • Journal of Korea Foundry Society
    • /
    • v.15 no.5
    • /
    • pp.494-506
    • /
    • 1995
  • Test castings in plate, disc, and cubic shaped castings for 0.2wt.% carbon and stainless steel have been poured to examine the effects of the riser dimensions including riser neck on the casting soundness. Three empirical methods were chosen in risering of steel castings. A computer program of solidification analysis considering liquid and solidification contraction was developed to apply for riserdesign calculated by using their methods in plate, disc, and cubic shaped castings, and to calculate the position and dimension of shrinkage cavity in complex shaped casting. The potential of present method has been successfully demonstrated by comparing predicted cavity shapes with those obtained in a series of experimental castings. Three empirical methods can be used in a practical way to make a rapid estimation of tie minimum riser diameter, but they can not provide a criterion of casting soundness with shape and material on all occasions. The shape and position of shrinkage cavity can be successfully predicted both using the present method and using risering calculated by their methods regardless of the shape and cast material.

  • PDF

A Study on Estimating of Fretting Wear of a Spline Coupling (스플라인 커플링의 프레팅 마멸 예측에 관한 연구)

  • Kim, Eung-Jin;Lee, Sang-Don;Cho, Yong-Joo
    • Tribology and Lubricants
    • /
    • v.25 no.4
    • /
    • pp.256-260
    • /
    • 2009
  • Fretting is a kind of wear which effects on reliability and durability. When machine parts are joined joint in parts such as a bolt or a rivet or a pin, fretting phenomenon is occurred by micro relative movement. When fretting occurs in joint parts, there is wear which is the cause of fatigue crack. Recently, although the ways of assessment of fatigue and damage tolerance are established, there is no way to evaluate fatigue crack initiation life by fretting phenomenon. Consequently, the prediction of life and prevention plan caused by fretting are needed to improve reliability. The objective of this paper is to predict fretting wear by using a experimental method and contact analysis considering wear process. For prediction of fretting wear volume, systematic and controlled experiments with a disc-plate contact under gross slip fretting conditions were carried out. A modified Archard equation is used to calculate wear depths from the contact pressure and stroke using wear coefficients obtained from the disc-plate fretting tests.