건축물에 시설되는 수변전설비의 지진 대책에 대한 조사 분석 (Analysis of earthquake countermeasure for electrical facility at building)

  • 김기현;이상익;전현재;배석명
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.359-362
    • /
    • 2008
  • Middle domestic the occurrence size which stews recently from the Korean Peninsula circumference country is augmenting on a large scale about earthquake about safe countermeasure part from the existing Natural Countermeasure Law 2008. Refers with the Earthquake Disaster Countermeasure Law to be new standard contents establishment by law and strengthened in March. Consequently the research is propelled about electric equipment earthquake-proof plan and countermeasure. The present paper investigated an equipment by domestic facility present condition about the change disappointment electric equipment which can supply all the member in the building an investigation analysis about problem point and improvement fact. Also about overseas electric equipment investigated about earthquake-proof plan relation system and facility present condition. Investigated the electric equipment earthquake-proof plan pertinent data which is advanced from like this existing nation and the equipment and application direction must apply to domestic presented. With character presents following the guide about electric equipment earthquake-proof plan becomes feed with the fact that will be able to use.

  • PDF

오염물질에 따른 HFIX 절연전선 피복의 특성 변화에 관한 연구 (Characteristics of HFIX Insulated Wire Sheaths Contaminated by Pollutants)

  • 최수길;남영재;진세영;김시국
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.8-17
    • /
    • 2020
  • 본 논문은 오염물질에 따른 HFIX 절연전선 피복의 특성변화에 관한 연구이다. HFIX 절연전선 피복을 오염시키기 위해 전선의 내수성시험 항목인 KS C IEC 60811-1-3 규격을 인용, 오염물질을 선정하고 선정된 오염물질에 시료를 노출시켜 주차 별 최대 4주간 노출된 실험시료를 제작하였다. 그 후 주차 별 시료들을 대상으로 최대인장하중 및 신장률을 측정하였다. 오염노출 기간이 길어짐에 따라 최대인장하중이 상온시료의 경우 6.22%, 고온시료 6.52%, 방청윤활제 19.94% 감소하였고, 신장률 또한 급격하게 감소하여 피복 특성저하가 뚜렷하게 나타났다. 추가적인 주사전자현미경을 이용한 표면 분석결과 오염기간이 길어짐에 따라 천공, 갈라짐, 용융 등의 구조 변경 현상이 발생되어 기계적 특성이 감소되는 것으로 나타났다. 따라서 절연전선의 성능저하를 방지하기 위해 검사주기 및 보수시기의 마련이 필요할 것으로 생각된다.

환기 및 희석을 적용한 폭발위험장소 검토에 관한 연구 (A Study on the Examination of Explosion Hazardous Area Applying Ventilation and Dilution)

  • 김남석;임재근;우인성
    • 한국가스학회지
    • /
    • 제22권4호
    • /
    • pp.27-31
    • /
    • 2018
  • 폭발위험장소의 구분은 인화성 물질을 취급하는 사업장에서 비용 및 안전 측면에서 매우 중요하다. 위험장소의 반경에 따라 전기기계 기구의 방폭기기 설치 여부가 결정되기 때문이다. 2017년 11월 6일부터 KS C IEC-60079-10-1:2015가 발행되어 새로운 기준으로 적용된다. 기존의 기준과 새로운 기준에 대한 차이를 이해하여 적용하는 것이 중요한 시점이다. 누출량 계산식에 누출계수 및 압축인자가 추가되었고 증발 풀 누출량 계산식, 누출공 크기 적용, 폭발위험장소의 모양이 추가 적용되었다. 안전계수 K값의 범위도 변경되었다. 또한 위험장소의 반경에는 기존기준은 가상체적에 환기횟수를 적용하였지만 개정기준은 누출 특성 값을 이용하여 산정된다. 본 연구에서는 환기 및 희석의 관점에서 기존 기준과의 차이점을 살펴보고 위험장소의 반경에 미치는 영향을 검토하였다. 기존 폭발위험장소를 선정한 기준과 개정기준을 기준으로 적용하여 비교 및 분석을 실시하였다. 연구결과 환기 및 희석이 잘 된다하더라도 실질적으로 위험반경에 영향이 없을 경우가 발생함을 알 수 있었다.

카본제조 부생가스 배출 안전성에 관한 연구 (A Study on the Safety of Carbon Manufacturing By-product Gas Emissions)

  • 주종율;정필훈;김상길;이성은
    • 대한안전경영과학회지
    • /
    • 제26권1호
    • /
    • pp.99-106
    • /
    • 2024
  • In the event of an emergency such as facility shutdown during process operation, the by-product gas must be urgently discharged to the vent stack to prevent leakage, fire, and explosion. At this time, the explosion drop value of the released by-product gas is calculated using ISO 10156 formula, which is 27.7 vol%. Therefore, it does not correspond to flammable gas because it is less than 13% of the explosion drop value, which is the standard for flammable gas defined by the Occupational Safety and Health Act, and since the explosion drop value is high, it can be seen that the risk of fire explosion is low even if it is discharged urgently with the vent stock. As a result of calculating the range of explosion hazard sites for hydrogen gas discharged to the Bent Stack according to KS C IEC 60079-10-1, 23 meters were calculated. Since hydrogen is lighter than air, electromechanical devices should not be installed within 23 meters of the upper portion of the Bent Stack, and if it is not possible, an explosion-proof electromechanical device suitable for type 1 of dangerous place should be installed. In addition, the height of the stack should be at least 5 meters so that the diffusion of by-product gas is facilitated in case of emergency discharge, and it should be installed so that there are no obstacles around it.

피난계단 출입구 유효너비가 수용인원의 피난시간에 미치는 영향 분석 (Analysis of the Effect of the Effective width of the Exit of the Evacuation Stairs on the Evacuation Time of the Occupants)

  • 양성훈
    • 한국재난정보학회 논문집
    • /
    • 제18권1호
    • /
    • pp.73-79
    • /
    • 2022
  • 연구목적: 건축법에 따라 설치되는 피난계단 출입구의 최소 유효 폭(90cm) 기준이 해당 층을 사용하는 전체 재실자의 피난 시간과는 어떤 관계가 있는지 피난 관점에서 알아보고자 하였다. 연구방법: 출입구 폭의 변화에 따라 재실자의 피난 시간에 어떠한 영향을 미치는지를 피난 시뮬레이션(Pathfinder)을 통하여 알아보았다. 연구결과: 출입구의 유효 폭이 최소기준 90cm보다 커지면 커질수록 피난계단으로의 피난 시간이 단축되는 것을 알 수 있었고, 더불어 출입구의 너비가 일정 크기 이상 되면 피난 시간은 더는 단축되지 않는다는 사실도 알 수 있었다. 이는 해당 층 전체 재실자의 수에 따라 피난계단 출입구의 유효 너비를 적정하게 달리 적용할 수 있다는 방증(傍證)이기도 한 것이다. 결론: 앞으로는 재실자의 피난 안전성 확보를 위해 용도별 전체 수용인원을 고려한 피난 계단 출입구 유효 폭 기준이 필요할 것으로 판단된다. 더불어 연구 및 실험을 통해 용도별 수용인원에 따른 다양한 출입구 유효 폭 기준이 만들어진다면 재실자의 피난 효율성이 크게 증대될 수 있을 것으로 기대된다.

배추재배용 비가림하우스 개발 (Development of Rain Shelter for Chinese Cabbage Rainproof Cultivation)

  • 유인호;이응호;조명환;류희룡;문두경
    • 생물환경조절학회지
    • /
    • 제23권4호
    • /
    • pp.293-302
    • /
    • 2014
  • 본 연구에서는 배추 재배에 적합한 규격과 생육 환경을 조성해 줄 수 있는 비가림하우스를 개발하고자 하였다. 전국 53개 배추 비가림재배 농가를 대상으로 비가림하우스 구조실태 및 구조개선 희망사항을 조사하여 비가림하우스 폭과 높이를 설정하였다. 비가림하우스 규격은 농기계 작업의 용이성, 농가의 의견 등을 고려하여 폭 6m, 처마높이 1.6m, 지붕높이 3.2m로 결정하였다. 서까래 규격별 구조안전성과 설치비를 분석한 후 설치비가 가장 적게 드는 Ø$25.4{\times}1.5t$ 파이프를 서까래로 하고 그 간격이 90cm인 모델을 기본 규격으로 결정하였다. 이 규격은 풍속 $27m{\cdot}s^{-1}$, 적설 17cm에 안전하기 때문에 이보다 기상하중이 큰 지역에는 적용하기가 곤란한데, 이를 해소하기 위해 피복재를 용마루까지 열어 골조 피해를 예방할 수 있는 구조로 설계하였다. 비가림하우스 양 측면에 있는 수동개폐기를 돌려 하우스밴드를 느슨하게 풀어주고 제어반에서 열림버튼을 누르면 개폐모터가 가이드 파이프를 따라 올라가면서 피복재가 용마루까지 개방된다. 피복재를 완전 개방할 경우 해충으로 인한 피해가 우려되므로 농가에서는 이를 막기 위해 방충망을 설치할 수 있다. 배추를 재배하는 기간에 태풍이 지나갈 수 있기 때문에 방충망이 구조안전에 미치는 영향을 분석하였다. $40m{\cdot}s^{-1}$의 바람이 방충망으로 덮여있는 비가림하우스 측면에 수직으로 작용하는 조건에 대해 유동-구조 연성해석 기법을 이용하여 구조안전성을 분석하였다. 유동해석 결과, 피복재 부분은 바람의 영향을 그대로 받기 때문에 피복재 표면에 압력이 크게 작용하였다. 방충망 부분에도 풍하중이 작용하였으나 피복재 부분보다는 압력이 작게 작용하고 분포가 균일하였다. 유동해석에서 도출된 압력 데이터를 적용하여 구조해석한 결과, 최대응력은 파이프의 끝단 즉, 지면부분에서 나타났으며, 그 값은 54.6Mpa이었다. 구조안전 판단 기준인 파이프의 허용응력 215MPa 이내여서 구조적으로 안전한 것으로 판단되었다.

온실용 얕은기초의 인발저항력 검토 (Uplift Capacity of Shallow Foundation for Greenhouse)

  • 윤성욱;최만권;이시영;강동현;문성동;유찬;윤용철
    • 생물환경조절학회지
    • /
    • 제24권3호
    • /
    • pp.187-195
    • /
    • 2015
  • 본 연구에서는 내재해형 플라스틱 온실과 유리온실의 기초에 대하여 인발저항력을 검토하기 위해 사질토 지반에서 실규모로 제작한 총 15개의 온실 기초를 이용하여 현장시험을 실시하였다. 그 결과, 대상 온실 기초의 최대인발저항력은 기초의 형태 및 규모가 서로 상이함에 따라 11.6 kN~82.4kN의 범위로 나타났다. 온실기초의 최대인발저항력 산정을 위해 제안된 이론식에 대하여 현장시험 결과를 이용하여 적용성을 검토한 결과 전반적으로 기존의 산정 이론식이 현장시험결과와 근접하는 수치를 제공하는 것으로 검토되었다. 다만, 본 연구에서 고려한 지반은 사질토 지반이며, 향후 점성토지반에 대하여 기존의 인발저항력 산정 이론식의 검증이 필요할 것으로 판단된다.