• Title/Summary/Keyword: disaster safety management

Search Result 1,259, Processing Time 0.037 seconds

First Report of the Fall Armyworm, Spodoptera frugiperda (Smith, 1797) (Lepidoptera, Noctuidae), a New Migratory Pest in Korea (한국에서 새로운 비래해충 열대거세미나방, Spodoptera frugiperda (Smith) 최초 보고)

  • Lee, Gwan-Seok;Seo, Bo Yoon;Lee, Jongho;Kim, Hyunju;Song, Jeong Heub;Lee, Wonhoon
    • Korean journal of applied entomology
    • /
    • v.59 no.1
    • /
    • pp.73-78
    • /
    • 2020
  • The fall armyworm, Spodoptera frugiperda (Smith, 1797), originated from tropical and subtropical America is one of sporadic agricultural pests in the world. Since the moth has high migration capacity, it rapidly expanded the world distribution such as Africa in 2016, India in 2018, and East-Asian countries in 2019. In Korea, this species was firstly found at maize fields of Jeju Island, in early June 2019, and subsequently detected at many counties of Jeolla-do and Gyeongsang-do in June and July 2019. The first invaded populations of S. frugiperda in Korea were genetically confirmed as one species, S. frugiperda by using a mitochondrial cytochrome oxidase subunit I (COI) gene, and analyzed to be comprised of two haplotypes (hap-1 and hap-2) each belonging to different clades. Among 31 COI sequences, the hap-1 sequence was predominant, accounting for 93.5%.

A Study on Response System of Marine Pollution Accident by Chemicals in United States (화학물질 해양오염사고에 대한 미국의 방제체제 연구)

  • Choi, Jong-Wook;Lee, Seung-Hwan
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.11a
    • /
    • pp.61-67
    • /
    • 2007
  • With an entering into force of OPRC-HNS started in June 14th 2007, establishment of response system in a nationwide scale to take care of accidents is required to respond rapidly and effectively. This necessities drove us to analyze national contingency plan for chemicals including national response system against accidents, which is in operation in the US. Main characteristics of the system are well described as an integrated incident command system with a cooperation of responsibilities facilities, manpower, and technical support. In addition, state anψor local authorities tend to have responsibilities on management of disaster with its response activities. Polluters are also charged to pay expenses 3 times expensive provided state or local authorities are conducted. In general, response activities are conducted by private sectors. However, the government will take action with Superfund if the response capacity is over than the polluters can. However, safety are regarded as a primary factor to be considered in the response activities, and try not to recover any pollutants. Personals belonging to USCG and EPA are required to complete specialized courses to promαe professional skills, and are also welcomed to participate in "certification program"

  • PDF

Technological Development Trends for Underground Safety in Urban Construction (도심지 공사시 지하안전 확보를 위한 기술개발 동향)

  • Baek, Yong;Kim, Woo Seok
    • Tunnel and Underground Space
    • /
    • v.27 no.6
    • /
    • pp.343-350
    • /
    • 2017
  • Amid increasingly saturated ground space, development of underground space has been booming throughout the world and excavation has been underway near the structure above or under the ground level. But the ground subsidence caused by improper or poor construction technologies, underground water leakage, sudden changes of stratum and the problem with earth retaining system component has been emerged as hot social issue. To deal with such problems nationwide, establishment of preventive and proactive disaster management and rapid restoration system has been pushed now. In this study, collection of the data on technology development trend to secure the underground safety was made, taking into account of internal change elements (changing groundwater level, damage to underground utilities, etc) and external change elements (vehicle load, earthquake and ground excavation, etc) during excavation. Amid the growing need of ground behavior analysis, ground subsidence evaluation technology, safe excavation to prevent ground subsidence and reinforcement technology, improvement of rapid restoration technology in preparation for ground subsidence and development of independent capability, this study is intended to introduce the technology development in a bid to prevent the ground subsidence during excavation. It's categorized into prediction/evaluation technology, complex detect technology, waterproof reinforcement technology, rapid restoration technology and excavation technology which, in part, has been in process now.

The Study on Design of Semiconductor Detector for Checking the Position of a Radioactive Source in an NDT (비파괴검사 분야에서 방사선원의 위치 확인을 위한 반도체 검출기 설계에 관한 연구)

  • Kim, Kyo-Tae;Kim, Joo-Hee;Han, Moo-Jae;Heo, Ye-Ji;Ahn, Ki-Jung;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.171-175
    • /
    • 2017
  • In the non-destructive inspection field, we invest a lot of time and resources in developing the radiation source system to ensure the safety of the workers. However, the probability of accidents is still high. In order to prevent potential radiation accidents in advance, it is necessary to directly verify the position of the radiation source, but the research is still insufficient. In this study, we developed a monitoring system that can detect the position of the radiation source in the source guide tube in the gamma-ray irradiator. The characteristics of the radiation detector are estimated by monte carlo simulation. As a result, the radiation detector for Ir-192 gamma-ray energy was analyzed to have secondary electron equilibrium at $150{\mu}m$ regardless of the semiconductor material. Also, it is expected that the gamma ray response characteristic is the best in $HgI_2$. These results are expected to be used as a basis for determining the optimal thickness of the radiation detector located in the detection part of the future monitoring system. In addition, when developing a monitoring system based on this, radiation workers can easily recognize the danger and secure safety, as well as prevent and preemptively respond to potential radiation accidents.

A Study on Wind Distribution of Mountain Area by Spot Measurements and Simulations (실측 및 해석을 통한 단순 산악지형의 바람장 분포 연구)

  • Kimg, Eung-Sik;Lee, Byung-Doo;Cho, Min-Tae;Kim, Jang-Whan
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.13-21
    • /
    • 2014
  • Forest fire has a number of variables and since the effects of wind fields are bigger than any other variables, it is essential to know wind direction and velocity for the forest fire extinguishing techniques and the prediction of fire spread. With regards to the local area that has a high chance of forest fire, the data from meteorological observatory in the area is used for the estimation of wind velocity. It is relatively easy to obtain automatic weather station (AWS) data which are available for the whole nation. There is a chance that the data from the weather station may be different with the actual data at the mountain areas. In this study simply shaped hills (Sae-byeol hill of Jeju Island and port Ma-geum in An-myeon Island in the sea side) were selected as the experimental locations to minimize the distortion of the wind field by the adjacent geographic features. Spot measurements and analysis of computational fluid dynamics (CFD) for the given geographic features were conducted to examine and compare their consistency. As a conclusion It is possible to predict wind patterns in these simple locations.

A Study on Identifying Problems by the Comparative Analysis of High-Rise Apartment Evacuation Design Codes (고층 아파트 피난설계기준 비교분석을 통한 문제점 도출 연구)

  • Hwang, Eun-Kyoung;Seo, Dong-Goo
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.47-52
    • /
    • 2017
  • The recent tragic outbreak of fire at the Grenfell Tower in the United Kingdom compels all branches of government to reexamine and reassess the safety measures against fires in high-rise buildings from a broad perspective. Accordingly, this study examined what problems stem from the current evacuation codes by comparative analysis of the high-rise apartment evacuation codes that range over various individual laws before introducing a new evacuation code. The outcome of this study can be utilized as basic data for amending the existing evacuation codes for high-rise buildings. The codes related to high-rise building evacuation include the Building Act, the Housing Act, the Skyscraper Disaster Management Act, and the Fire-Fighting System Act. Some local governments have also drawn up their own codes and put them into practice. Comparative analysis of the major evacuation codes has helped identify a variety of problems, such as different codes being applied to each individual law and ordinance, the use of additional codes other than the provisions of laws and ordinances, and the in effectiveness of evacuation codes. Most of these problems occur when diverse codes are applied to a single building, which means that cooperation among the relevant ministries is urgently needed to improve the related codes in the future.

A Study on Developmental Plan of In-Flight Security Officer in Korea - Focused on U.S. Federal Air Marshal Service - (항공기내보안요원제도의 발전 방안에 관한 연구 - 미국 연방 Air Marshal 제도를 중심으로-)

  • Park, Hee-Kyun;Moon, Jun-Seob
    • Korean Security Journal
    • /
    • no.53
    • /
    • pp.83-105
    • /
    • 2017
  • The purpose of this study is to identify the problems of In-Flight Security Officer responsible for the security of the aircraft in the situation where Acts of Unlawful Interference in Aircraft shows an increasing tendency and the aircraft security is threatened by the terror threat of IS(Daesh) and to suggests its policy implications. Based on the problems of In-Flight Security Officer system found in the media reports and laws, the US Air Marshal system and the domestic similar system were presented to the In-Flight Security Officer developmental implications. First, it is necessary to revise the "Operational Guidelines for Airline Operators' In-Flight security officer" and the related qualifications to the "National Technical Qualifications" system. Second, the plan to change the national civil servants of In-Flight Security Officer in the aircraft, Third, it is a plan to use the registered security guard system in the aircraft. Although this study has limitations the accessibility of information related to aviation security. But, contributions of this study is that the government's efforts to create the public sector jobs, the "strengthening of public services in the country", "the establishment of national accountability for safety accident prevention and disaster safety management" in the "A five-year plan for Government Operation" that it has a timeliness in that it is together. In addition, since there are not many researches related to In-Flight Security Officer, this study also has another contribution as a basic study of the researchers in the aviation security aircraft in the future.

  • PDF

Risk Assessment of Semiconductor PR Process based on Frequency Analysis of Flammable Material Leakage (반도체 PR 공정의 인화성 물질 누출 빈도분석을 통한 위험성 평가)

  • Park, Myeongnam;Chun, Kwang-Su;Yi, Jinseok;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.5
    • /
    • pp.1-10
    • /
    • 2021
  • Semiconductor Photo Resist (PR) automation equipment uses a mixture of several flammable substances, and when it leaks during the process, it can lead to various accidents, therefore, risk assessment is necessary. This study analyzed the frequency of leakage of Acetone and PGMEA used in PR automation equipment and the frequency at which such leakage could lead to a fire accident through the frequency analysis method, and evaluated the need for additional risk reduction measures in the current facility. Based on the process leak data and ignition probability data of IOGP, leak frequency analysis and ignition probability were derived, and the frequency of actual fire accidents was analyzed by combining them. The frequency of material leakage in semiconductor PR process is 7.30E-03/year, and fire accidents can occur by acetone that exists above the flash point when the material is leaked, the frequency was calculated at the level of 1.24E-05/year. According to the UK HSE, for a major accident occurring with a frequency of 1.24E-05/year, it is defined as "Broadly Acceptable", a level that does not require additional measures for risk reduction when it causes 7 or less deaths, and due to the process operated by two people, no additional risk reduction are required.

Pullout Behavior of Mechanically Stabilized Earth Wall Abutment by Steel Reinforcement and Backfill Properties (금속 보강재와 채움재 특성에 따른 보강토교대의 인발거동 분석 연구)

  • Kim, Taesu;Lee, Soo-Yang;Nam, Moon S.;Han, Heuisoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.750-757
    • /
    • 2018
  • The mechanically stabilized earth wall abutment is an earth structure using a mechanically stabilized earth wall and it uses in-extensional steel reinforcements having excellent friction performance. In order to analyze the pullout behavior of in-extensional steel reinforcements usually applied on the mechanically stabilized earth wall abutment, effects of stiffness and particle-size distributions of backfills and also horizontal spacings were considered in this study. As a result of parametric analyses, the highest pulling force acted on the uppermost reinforcement, and the stiffness and the particle-size distributions of the backfill significantly affected the pulling resistance of the reinforced soils. The internal friction angle of backfills should be at least 25 degrees, the coefficient uniformity factor should be at least 4, and the horizontal spacing of the uppermost steel reinforcement should be less than 25cm. Therefore, in order to secure the pullout resistance of the reinforced soil, it is necessary a properly spacing of reinforcement and more strict quality control for the backfill.

Change in the Concrete Strength of Forest Road Drainage Systems Caused by Forest Fires (산불로 인한 임도 배수시설의 콘크리트 강도 변화)

  • Ye Jun Choe;Jin-Seong Hwang;Young-In Hwang;Hyeon-Jun Jeon;Hyeong-Keun Kweon;Joon-Woo Lee
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.4
    • /
    • pp.451-458
    • /
    • 2023
  • As forest fires continue to increase in scale worldwide, the importance of forest roads in relation to forest fire prevention and suppression has become increasingly evident. To ensure effective functioning during a forest fire disaster, it is crucial to apply appropriate road planning and ensure roads' structural integrity. However, previous studies have predominantly focused on the impact of forest fires on firebreak efficacy and road placement, meaning that insufficient attention has been paid to ensuring the safety of these facilities. Therefore, this study sought to compare the strength of concrete facilities within areas damaged by forest fires over the past three years by using the rebound hammer test to identify signs of thermal degradation. The results revealed that concrete facilities damaged by forest fires exhibited significantly lower strength (15.6 MPa) when compared with undamaged facilities (18.0 MPa) (p<0.001), and this trend was consistent across all the target facilities. Consequently, it is recommended that safety assessment criteria for concrete forest road facilities be established to prevent secondary disasters following forest fire damage. Moreover, continuous monitoring and research involving indoor experiments are imperative in terms of enhancing the stability of forest road structures. It is expected that such research will lead to the development of more effective strategies for forest fire prevention and suppression.