Automation of electrical acoustic experimental apparatus for the directivity measurement of sound (소리의 지향성 측정을 위한 전기음향실험기기의 자동화)

  • Jarng, Soon-Suck;Ko, Jae-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.574-576
    • /
    • 2004
  • The directivity of the sound pressure increases the sensitivity of the incoming sound from specific directions. The directivity measurement of the sound pressure is usually done in an anechoic room using a sloping motor. In this paper a replaceable anechoic chamber was designed for the acoustic directivity pattern measurement. Electrical equipments were interfaced with a PC for experiment automatic control. Some comparative results are shown in the result.

  • PDF

Automatic control of experimental apparatus for sound's directivity measurement direction acoustic wave (소리의 방향성 측정을 위한 실험기기의 자동제어)

  • Jarang, Sun-Suck;Ko, Jae-Ha;Lee, Je-Hyeong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.591-594
    • /
    • 2004
  • The directivity of the sound pressure increases the sensitivity of the incoming sound from specific directions. The directivity measurement of the sound pressure is usually done in an anechoic room using a steping motor. In this paper a replaceable anechoic chamber was designed for the acoustic directivity pattern measurement. Electrical equipments were interfaced with a PC for experiment automatic control. Some comparative results are shown in the result.

  • PDF

Directivity Analysis of Ultrasonic Wave Reflected from the Artificial Defect in Simulated Butt Welded Joint (가상 용접부내의 결함으로부터 반사된 초음파의 지향성 해석)

  • Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.2
    • /
    • pp.378-385
    • /
    • 1995
  • The ultrasonic non-destructive testing uses the directivity of the ultrasonic pulse wave which propagates in one direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of ultrasonic wave is closely related to determination of probe arrangement, testing sensitivity, scanning pitch and defect location and characterization. The paper measured the directivity of shear wave, which reflected from artificial defect located in weld metal zone in butt welded joint similar model made of pyrex glass by using visualization method. 2 MHz and 4 MHz angle probes were used to measure the directivity of reflection wave at the artificial defect. The directivity of shear waves reflected from the defect was different according to the probe position and the shape of butt welded joint. The difference of directivity of reflection wave was existed between 2 MHz and 4 MHz angle probes. The angle of reflection wave became equal to angle of incidence as increase of the height of excess metal.

  • PDF

Numerical Simulation of Directivity for Probe and Surface Defect (탐촉자와 표면 결함에 대한 지향성의 수치 실험에 관한 연구)

  • Nam, Young-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.1
    • /
    • pp.291-298
    • /
    • 1995
  • An ultrasonic testing uses the directivity of the ultrasonic wave which propagates in one direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. This paper studied the directivity of shear waves emitted from angle probes and scattered from surface defects by using visualization method. These experimental results were compared with the theory which was based on the continuous wave. The applicability of continuous wave theory was discussed in terms of the parameter $d/{\lambda}$; where d is transducer or defect size and ${\lambda}$ is the wavelength. In the case of angle probes, the experimental results show good agreement with theoretical directivity on the principal lobe. When defect size was smaller than the wavelengths, clear directivity in the reflected wave was observed. In the case of the same ratio of defect size to wavelength, the directivity of reflected waves from the defect show almost the same directivity in spite of frequency differences. When the $d/{\lambda}$ is greater than 1.5, measured directivities almost agreed with the theoretical one.

  • PDF

Directivity Synthesis Simulation of Ultrasonic Transducer Using Gauss Elimination Method (GAUSS 소거법을 이용한 초음파 트랜스듀서의 지향성합성 SIMULATION)

  • 이정남;조기량;이진선;이문수
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.4
    • /
    • pp.20-27
    • /
    • 1995
  • A numerical simulation is carried out on the directivity synthesis of ultrasonic transducers by point source array. Gauss elimination method is practiced by means of a directive method to realize the desired directivity. Desired directivity is chosen to be that of a directivity of line source, a beam width and a direction arbitrary specified. On the numerical result, Gauss elimination method is showed high speed ca- lculative simulation and stability of system more than iterative method(LMS, DFP). Numerical simulations are carried out by PC(CPU:80486 DX2, RAM 16Mbyte).

  • PDF

Binaural Directivity Pattern Measurements of the KEMAR Head Model with Two Twin Hearing Aid Microphones (양이 각각 두 개의 보청기 마이크로폰을 장착한 KEMAR 머리 모델의 양이 방향성 측정)

  • Jarng, Soon-Suck;Kwon, You-Jung;Lee, Je-Hyeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.1E
    • /
    • pp.25-31
    • /
    • 2006
  • Two twin microphones may produce particular patterns of binaural directivity by time delays between the twin microphones. The boundary element method (BEM) was used for the simulation of the sound pressure field around the KEMAR head model in order to quantify the acoustic head effect. The sound pressure onto the microphone was calculated by the BEM to an incident sound pressure. Then a planar directivity pattern was formed by four sound pressure signals from four microphones. The optimal binaural directivity pattern may be achieved by adjusting time delays at each frequency while maintaining the forward beam pattern is relatively bigger than the backward beam pattern. The simulation results were verified by the experimental measurement.

Characteristics of Coupler with high Directivity (높은 지향성을 갖는 결합기 특성)

  • Park, Yong-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.317-321
    • /
    • 2012
  • In this paper, properties of directional coupler with high directivity was investigated. The directional couler is used to check and verify the power, frequency, and antenna reflection of signal at transmission station for mobile communications. To get the high directivity in the directional coupler, directional coupler was simulated and fabricated. we obtained the directional coupler having more than 31dB directivity.

Binaural Directivity Pattern Simulation of the KEMAR Head Model with Two Twin Hearing Aid Microphones by Boundary Element Method

  • Jarng Soon Suck;Kwon You Jung;Lee Je Hyeong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.3E
    • /
    • pp.115-122
    • /
    • 2005
  • Two twin microphones may produce particular patterns of binaural directivity by time delays between twin microphones. The boundary element method (BEM) was used for the simulation of the sound pressure field around the head model in order to quantify the acoustic head effect. The sound pressure onto the microphone was calculated by the BEM to an incident sound pressure. Then a planar directivity pattern was formed by four sound pressure signals from four microphones. The optimal binaural directivity pattern may be achieved by adjusting time delays at each frequency while maintaining the forward beam pattern is relatively bigger than the backward beam pattern.

Fabrication of Higher Directivity Acoustic Transducer Using the Self-demodulation Effect (자기복조 효과를 이용한 초지향성 음향트랜스듀서 제작)

  • 고영준;남효덕;서희돈;장호경
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.9
    • /
    • pp.744-750
    • /
    • 2001
  • Higher directivity acoustic transducer using the self-demodulation effect was fabricated. The structure of transducer was designed such as dimension and support type of the piezoelectric element, the vibrating metal plate, and the housing case. Based on the design, the transducer was fabricated and measured its acoustic characteristics. Also, AM modulated driving circuit was designed for using the self-demodulation effect. The piezoelectric sounder with 200kHz resonant frequency and 20kHz bandwidth was designed by considering the sharp directivity and the sound pressure. The design and fabrication method worked in this study can be utilized in development of various speakers with higher directivity and broader bandwidth.

  • PDF

Simple Estimation of Sound Source Directivity in Diffused Acoustic Field: Numerical Simulation (확산음향장에서의 음원 지향성 간이추정: 수치시뮬레이션)

  • Kim, Kookhyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.421-426
    • /
    • 2019
  • The directivity of an underwater sound source should be measured in an acoustically open field such as a calm sea or lake, or an anechoic water tank facility. However, technical difficulties arise when practically implementing this in open fields. Signal processing-based techniques such as a sound intensity method and near-field acoustic holography have been adopted to overcome the problem, but these are inefficient in terms of acquisition and maintenance costs. This study established a simple directivity estimation technique with data acquisition, filtering, and analysis tools. A numerical simulation based on an acoustic radiosity method showed that the technique is practicable for sound source directivity estimation in a diffused reverberant acoustic field like a reverberant water tank.