• 제목/요약/키워드: direct torque control method

검색결과 170건 처리시간 0.023초

3 레벨 인버터로 구동되는 유도전동기 직접 토크제어의 저속운전 성능 개선 (AN OBSERVER-BASED DTC OF INDUCTION MOTORS DRIVEN BY 3-LEVEL INVERTER FOR IMPROVING LOW SPEED OPERATION)

  • 박영민;최세경;이세현;이교범;유지윤;송중호;최익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1030-1032
    • /
    • 2000
  • Direct torque control algorithm for 3-level inverter-fed induction motors is proposed. Conventional selection method of the stator voltage vector shows problems of stator flux drooping phenomenon and undesirable torque control appeared especially at the low, speed operation. To overcome these problems, a proposed method uses intermediate voltage vectors, which are inherently generated in 3-level inverters. An adaptive observer is also employed to estimate some state-variables and motor parameters, which takes a deep effect on the performance of the low speed operation. Simulation and experiment results verify effectiveness of the proposed algorithm.

  • PDF

다상 영구자석 동기 전동기의 자기 및 상호 인덕턴스 계산 (Calculation of Self and Mutual Inductances in Multi-Phase Permanent Magnet Synchronous Motor)

  • 이치우
    • 한국자기학회지
    • /
    • 제27권1호
    • /
    • pp.9-17
    • /
    • 2017
  • 다상 전동기는 기존의 3상 전동기와 비교하여 높은 신뢰성과 성능의 이점 때문에 고 신뢰성을 요하는 전장과 특수기기 분야에서 많은 관심을 갖고 있다. 본 연구에서는 다상 전동기들 중 5상 영구자석 동기 전동기를 이용하여 전동기 제어의 주요 변수인 자기 인덕턴스와 상호 인덕턴스를 수식을 통한 추정 방법을 다룬다. 최근 대부분의 고효율 구동 전동기들은 FOC(Field Orinted Control)와 DTC(Direct Torque Control) 제어를 이용하므로 전압 방정식에서 가장 중요한 인덕턴스를 정확하게 추정하는 것이 중요하다. 인덕턴스를 수식적으로 계산하기 위해서 본 연구에서는 WFT(Winding Function Theory)를 적용하였다. 계산된 인덕턴스의 결과 값의 타당성 유무를 확인하기 위하여 유한요소해석과 비교 하였으며 약 3%의 편차를 가지는 것을 확인하였다. 최종적으로 WFT를 이용하여 계산된 인덕턴스를 FOC와 DTC 제어에 필요한 값인 d축과 q축 인덕턴스로 변환하는 과정을 소개한다.

PFC 컨버터와 DTC를 이용한 BLDC 모터의 구동 시스템 구현 (Implementation of the BLDC Motor Drive System using PFC converter and DTC)

  • 양오
    • 전자공학회논문지SC
    • /
    • 제44권5호
    • /
    • pp.62-70
    • /
    • 2007
  • 본 논문에서는 일정 토크영역에서 승압형 PFC 컨버터와 직접토크제어(DTC) 방법을 사용하여 BLDC 모터의 구동 시스템을 DSP(TMS320F2812)로 구현하였다. 기존의 6단계 PWM 전류제어와 달리 미리 정한 샘플시간 마다 간단한 look-up 표로부터 2상 도통 모드에 대한 인버터의 전압 상태 벡터를 설정함으로써 원하는 전류파형을 만들었으며 이로부터 기존의 전류제어기보다 훨씬 빠른 토크 응답특성을 얻을 수 있었다. 또한 BLDC 모터의 비 이상적인 사다리형 역기전력에 의해 발생되는 저주파 토크변동을 저감하기 위하여 위치 loop-up 표를 사용하였다. 아울러 역률을 보정하기 위해 승압형 PFC 컨버터를 구성하였고 이 때 전파 정류된 입력전압과 출력전압, 인덕터의 전류에 의해 평균전류모드 제어 방식으로 80 kHz마다 PWM 듀티(duty)가 조절 되도록 하였다. 이와 같이 복잡한 제어 알고리즘은 초고속 DSP의 출현으로 PFC와 DTC 알고리즘이 동시에 제어가 가능하며, 본 논문에서는 DTC 알고리즘을 구현할 때 DSP의 일반 범용의 출력포트를 사용하여 구현하였고 단지 PFC에서만 1개의 PWM을 사용하여 디지털 제어기를 구현하였다. 실험을 통해 DTC 알고리즘과 PFC 컨버터를 이용한 BLDC 모터 구동 시스템의 타당성과 효용성을 보였고, 실험결과로부터 PFC 컨버터를 사용하지 않았을 때는 역률이 약 0.77이었으나 PFC 컨버터를 사용하였을 때는 부하변동에 관계없이 약 0.9997로 크게 향상됨을 확인하였다.

Development, Implementation and Experimentation on a dSPACE DS1104 of a Direct Voltage Control Scheme

  • Hmidet, Ali;Dhifaoui, Rachid;Hasnaoui, Othman
    • Journal of Power Electronics
    • /
    • 제10권5호
    • /
    • pp.468-476
    • /
    • 2010
  • This paper proposes and develops a new direct voltage control (DVC) approach. This method is designed to be applied in various applications for AC drives fed with a three-phase voltage source inverter (VSI) working with a constant switching time interval as in the standard direct torque control (DTC) scheme. Based on a very strong min(max) criterion dedicated to selecting the inverter voltage vector, the developed DVC scheme allows the generation of accurate voltage forms of waves. The DVC algorithm is implemented on a dSPACE DS1104 controller board and then compared with the space vector pulse width modulation technique (SVPWM) in an open loop AC drive circuit. To demonstrate the efficiency of the developed algorithm in real time and in closed loop AC drive applications, a scalar control scheme for induction motors is successfully implemented and experimentally studied. Practical results prove the excellent performance of the proposed control approach.

A Five-Phase Induction Motor Speed Control System Excluding Effects of 3rd Current Harmonics Component

  • Kim, Min-Huei;Kim, Nam-Hun;Baik, Won-Sik
    • Journal of Power Electronics
    • /
    • 제11권3호
    • /
    • pp.294-303
    • /
    • 2011
  • In this paper an effective five-phase induction motor (IM) and its drive methods are proposed. Due to the additional degrees of freedom, the five-phase IM drive presents unique characteristics for enhancing the torque producing capability of the motor. Also the five-phase motor drives possess many other advantages when compared to traditional three-phase motor drives. Some of these advantages include, reducing the amplitude and increasing the frequency of the torque pulsation, reducing the amplitude of the current without increasing the voltage per phase and increasing the reliability. In order to maximize the torque per ampere, the proposed motor has concentrated winding, the produced back electromotive force (EMF) is almost trapezoidal, and the motor is supplied with the combined sinusoidal plus the third harmonic of the currents. For demonstrating the superior performance of the proposed five-phase IM, the motors are also analyzed on the synchronously rotating reference frame. To supply trapezoidal current waveform and to exclude the effect of the $3^{rd}$ harmonic current, a new control stratagem is proposed. The proposed control method is based on direct torque control (DTC) and rotor flux oriented control (RFOC) of the five-phase IM drives. It is able to reduce the acoustical noise, the torque, the flux, the current, and the speed pulsations during the steady state. The DTC transient merits are preserved, while a better quality steady-state performance is produced in the five phase motor drive for a wide speed range. Experimental results clearly demonstrated a more dynamic steady state performance with the proposed control system.

An Off-line Maximum Torque Control Strategy of Wound Rotor Synchronous Machine with Nonlinear Parameters

  • Wang, Qi;Lee, Heon-Hyeong;Park, Hong-Joo;Kim, Sung-Il;Lee, Geun-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.609-617
    • /
    • 2016
  • Belt-driven Starter Generator (BSG) differs from other mild hybrid systems as the crankshaft of vehicle are not run off. Motor permits a low-cost method of adding mild hybrid capabilities such as start-stop, power assist, and mild levels of regenerative braking. Wound rotor synchronous motor (WRSM) could be adopted in BSG system for HEV e-Assisted application instead of the interior permanent magnet synchronous motor (IPMSM). In practice, adequate torque is indispensable for starter assist system, and energy conversion should be taken into account for the HEV or EV as well. Particularly, flux weakening control is possible to realize by adjusting both direct axis components of current and field current in WRSM. Accordingly, this paper present an off-line current acquisition algorithm that can reasonably combine the stator and field current to acquire the maximum torque, meanwhile the energy conversion is taken into consideration by losses. Besides, on account of inductance influence by non-uniform air gap around rotor, nonlinear inductances and armature flux linkage against current variation are proposed to guarantee the results closer to reality. A computer-aided method for proposed algorithm are present and results are given in form of the Look-up table (LUT). The experiment shows the validity of algorithm.

고정자 저항의 변동에 강인한 유도전동기의 직접 벡터제어 (Robust Direct Vector Control of Induction Motor for Variation of stator Resistance)

  • 정종진;김진규;이득기;김흥근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2002-2004
    • /
    • 1998
  • In this paper, the compensation algorithm of the stator resistance which is essential to improving the performance of the direct vector control system is proposed. This paper focuses on the improvement in the torque response of the direct vector control in a constant speed region. The conventional compensation algorithms are analyzed and a new method is developed to compensate the stator resistance in the direct vector control system. In addition, the effect of the variation of the stator resistance on the drive performance is analyzed for the vector control. The proposed algorithm is very simple to implement that does not require the modifications on the motor model or additional interrupts of the controller. Also, the value of the stator resistance can be obtained in real-time through the measurement of the terminal voltage and current. From the simulation and experimental results, the validity of the proposed scheme is confirmed.

  • PDF

적응 자속 관측기를 이용한 유도전동기의 효율 최적화 제어 (Efficiency Optimization Control of Induction Motor using Adaptive Flux Observer)

  • 정동화;박기태;이홍균
    • 한국안전학회지
    • /
    • 제16권4호
    • /
    • pp.88-95
    • /
    • 2001
  • Stator core loss has significant adverse effects when an induction motor is controlled by the conventional vector control method. Therefore, taking core toss into account should make it possible to control the torque very precisely. This paper proposes a speed sensorless vector control method for an induction motor at optimum efficiency and high response taking core loss account. The proposed vector control system consists of a speed adaptive rotor flux observer which takes core loss into account and employs a direct vector control which compensates for the influence of core loss. Also, in this paper, a vector controlled induction motor with a deadbeat rotor flux controller is developed. The method ensures optimum efficiency in the steady state without degradation of the dynamic response. The validity of the proposed technique is confirmed by simulation results for induction motor drive system.

  • PDF

특수차량용 엔진 직결형 IPMSG의 넓은 속도운전 범위를 위한 부스트/약자속 제어기에 관한 연구 (A Study on Boost/Flux-Weakening Controller for Wide Speed Operation Range having Engine and IPMSG for Special Equipment Vehicle)

  • 이상건;김성안;조윤현
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.54-61
    • /
    • 2014
  • This paper proposes a boost/flux-weakening controller (BFWC) for wide speed operation range having engine and interior permanent magnet synchronous generator (IPMSG) for special equipment vehicle. The proposed BFWC exploits direct torque/flux control (DTFC) scheme based on space vector modulation method to control the constant DC voltage output within the entire speed operation range of engine. And, to improve the response characteristics of maximum torque per ampere (MTPA) operation and flux-weakening operation, the MTPA and flux-weakening feed-forward controllers are applied. To estimate feasibility and usefulness of the proposed controller, the simulation and experimental results are compared.

유도전동기의 디지탈 속도 제어 (Speed control of a induction motor system using digital control method)

  • 이충환;김상봉;하주식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.987-992
    • /
    • 1992
  • In recent years, induction motor is applied for several industrial actuatung parts instead of direct current motor because of the robust construction, nonexpensive and maintenance-free actuator etc. and having capability of speed control according to development of power electrounics and microprocessor techniques. In the paper, a microprocessor-based digital control approach for spped control of induction motor system is presented by considering a simple modelling equation as the system expression equation of induction motor and using the self tuning control and torque effdforward control method. As the model equation of the induction motor system, we use a second order differential equation which is well known in the modeling equation is induced form the control theory stand point such tath we can describe usually the motor system connected by inverter, generator and load etc. The effectiveness of the control system composed by the above mentioned design concept is illustrated by the expermental result in the presence of step reference change and generator load variation.

  • PDF