• Title/Summary/Keyword: direct test

Search Result 3,323, Processing Time 0.04 seconds

Analysis of Signal Properties in accordance with electrode area of x-ray conversion material (X선 검출 물질의 전극 면적에 따른 신호특성 분석)

  • Jeon, S.P.;Kim, S.H.;CHO, K.S.;Jung, S.H.;Park, J.K.;Kang, S.S.;Han, Y.H.;Kim, K.S.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.5-9
    • /
    • 2010
  • In recent, a digital x-ray detector attracted worldwide attention and there are many studies to commercialize. There are two methods in digital x-ray detector. This method is an Indirect method and Direct method. This study is to see the differences between the digital x-ray detector based on a-Se used in the existing indirect conversion method and an x-ray conversion material that has better SNR(Signal-to-noise ratio) and property than the a-Se. To solve the problem that is difficult to make a large area film using Screen-Print method, we used a Screen-Print method. In this study, we used a polyclystal $HgI_2$ as x-ray conversion material and a sample thickness is $150{\mu}m$ and an area is $3cm{\times}3cm$. ITO(Indium-Tin-Oxide) electrode was used as top electrode using a Magnetron Sputtering System and each area is $3cm{\times}3cm$, $2cm{\times}2cm$ and $1cm{\times}1cm$ and then we evaluated darkcurrent, sensitivity and SNR of the $HgI_2$ film are measured, then we evaluated the electrical properties. And we used a current integration mode when I-V test. This experiment shows that the sensitivity increases in accordance with the area of the electrode but the SNR is decreased because of the high darkcurrent. Through fabricating of various thicknesses and optimal electrodes, we will optimize SNR in the future work.

An Empirical Study of Social Network Service (SNS) Continuance: Incorporating the Customer Value-Satisfaction-Loyalty Model into the IS Continuance Model (소셜 네트워크 서비스(SNS)의 지속이용의도에 관한 연구: IS 지속이용모델과 고객 가치-만족-충성도 모델의 통합적 접근)

  • Choi, Sujeong
    • Asia pacific journal of information systems
    • /
    • v.23 no.4
    • /
    • pp.1-28
    • /
    • 2013
  • Given that smartphone-based social network services (SNS), such as KakaoStory is now being widely used as a way for people to connect and communicate with each other, this study examines key factors leading to the continued use of SNS. People have been using PC-based SNS, such as Cyworld, for years are now using smartphone-based SNS, such as KakaoStory. KakaoStory developed by KakaoTalk has rapidly grown up as the largest smartphone-based SNS in Korea as smartphone penetration increases. It is more difficult for firms to maintain their current users over time in that alternative SNSs satisfying people's new needs are constantly emerging and evolving. In this sense, one of the most challenging issues for SNS firms is how to retain their current users in the long run. However, there are few empirical studies on this issue. Applying the IS continuance model proposed by Bhattacherjee [2001], this study explores key determinants of users' smartphone-based SNS continuance intention. The model suggests that perceived usefulness and user satisfaction are the key determinants of IS continuance intention. However, the model includes only the utilitarian value that users can obtain through the use of smartphone-based SNS, by considering perceived usefulness. Therefore, the study attempts to extend the IS continuance model by considering hedonic and social values simultaneously. More specifically, we consider subjective norms as social value that are proposed by the theory of reasoned action and the theory of planned behavior. We also consider perceived enjoyment as hedonic value that is emphasized as a key factor influencing users' behavior intention and actual behavior, particularly in the context of hedonic IS use. By considering the three values in our model simultaneously, we could offer a deeper understanding of smartphone-based SNS continuance. That is, this study could offer an explanation of how each value is associated with user satisfaction and SNS continuance intention. The customer value-satisfaction-loyalty model can strengthen the assertion that smartphone-based SNS continuance intention is determined by various different types of customer values, such as utilitarian, hedonic, and social ones. Moreover, the model provides a theoretical basis for the assertion that customer values lead to increased loyalty via customer satisfaction. In this regard, we theorize that SNS continuance intention is influenced by users' various values, namely perceived usefulness, perceived enjoyment, and subjective norms, via user satisfaction. To test the proposed research model and hypotheses, we conducted a partial least squares analysis using a total of 253 data collected on the users of smartphone-based SNS (i.e., KakaoStory). The key findings are as follows: First, it has been found that SNS continuance intention considerably depends on user satisfaction. Second, user satisfaction is determined by confirmation, perceived usefulness, and perceived enjoyment. Third, concerning the effects of the three values on SNS continuance intention, only perceived enjoyment regarded as hedonic value was statistically significant. That is, perceived usefulness considered as utilitarian value and subjective norms considered as social value had no effect on SNS continuance intention. Finally, our results indicate that confirmation increases perceived usefulness, perceived enjoyment, and user satisfaction. The results reconfirm the effectiveness of IS continuance model in predicting smartphone-based SNS continuance intention. Moreover, the results demonstrate that perceived enjoyment reflecting hedonic value is the most important predictor of SNS continuance intention. Therefore, it is imperative for firms to meet SNS users' hedonic value to retain them in the long run. Meanwhile, we could not find any empirical evidence to support the assertion that subjective norms are associated with user satisfaction and SNS continuance intention. The results lead us to conclude that when users have enough direct experience in SNS use, subjective norms have no effect on SNS continuance intention. Discussions and implications of the results are provided.

A Comparative Study of Blood Lead Measurement by Polarized Zeman Effect Correction AAS and D2 Correction AAS Method (편광 Zeeman 보정 및 D2 보정 방법에 의한 혈중연 측정치의 비교 연구)

  • Lee, Seok Ki;Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.59-67
    • /
    • 1995
  • Blood lead assay by $D_2$ lamp background correction method of atomic absorption spectrophotometer(AAS) with wavelength of 283.3 nm is most popular in occupational health practice in Korea. On the other hand, $D_2$ lamp background correction method with wavelength of 217.0 nm is also often used in general chemical analysis for lead assay in general purpose. But both methods have some weakness of background correction which brought direct effect on the results of analysis. Recently blood lead assay with polarized Zeeman effect of AAS was introduced and is now preferred in many laboratory than $D_2$ correction method in blood lead analysis. But still AAS with $D_2$ lamp are widely used in the field of occupational health in Korea. This study compared blood lead assay data with $D_2$ correction methods(283.3 and 217.0 nm) and with that of polarized Zeeman effect correction method to evaluate the validity of 02 correction methods. The results obtained were as follows; 1. Taking the value of polarized Zeeman effect method as reference value of 1.00, the mean relative value of $D_2$ correction method with wavelength of 217.0 nm was 0.92 and that with wavelength of 283.3 nm was 0.90 respectively in the analysis of blood lead whose value were below $20.0{\mu}g/dl$(p<0.001). Both mean values were statistically smaller than polarized Zeeman effect correction method. But in the analysis of blood whose value were between 20.0 to $20.0{\mu}g/dl$, the mean relative value of $D_2$ correction method was 0.96 in both wavelength and did not differ from polarized Zeeman effect method(p<0.001). There was no difference of blood lead between $D_2$ correction method and polarized Zeeman effect method in the analysis of blood lead whose value were over $40.0{\mu}g/dl$. 2. The variations of background correction value in polarized Zeeman effect method were not changed by increase of blood lead, but those in $D_2$ correction methods were increased by the increase of blood lead. While then relative standard deviation(RSD) of data measured by Zeeman effect method were decreased by the increase of blood lead, those by $D_2$ methods were nol differed by the increase of blood lead.

  • PDF

Evaluation of Peptide Nucleic Acid Probe-Based Fluorescence In Situ Hybridization for the Detection of Mycobacterium tuberculosis Complex and Nontuberculous Mycobacteria in Clinical Respiratory Specimens (임상 객담검체에서 Peptide Nucleic Acid Probe를 이용한 결핵과 비결핵 항산균의 구분)

  • Lee, Seung Hee;Kim, Shine Young;Kim, Hyung Hoi;Lee, Eun Yup;Chang, Chulhun L.
    • Annals of Clinical Microbiology
    • /
    • v.18 no.2
    • /
    • pp.37-43
    • /
    • 2015
  • Background: Tuberculosis is globally the most important cause of death from single pathogen. Rapid and accurate identification of mycobacteria is essential for the control of tuberculosis. We evaluated a fluorescence in situ hybridization (FISH) method using peptide nucleic acid (PNA) probes for the differentiation of Mycobacterium tuberculosis complex (MTB) and nontuberculous mycobacteria (NTM) in direct smears of sputum specimens. Methods: The cross-reactivity of MTB- and NTM-specific PNA probes was examined with reference strains of M. tuberculosis ATCC 13950, Mycobacterium kansasii ATCC 12479, Mycobacterium fortuitum ATCC 6841, several clinical isolates of mycobacteria (Mycobacterium abscessus, Mycobacterium avium, Mycobacterium intracellulare, Mycobacterium gordonae and Mycobacterium chelonae), and 11 frequently isolated respiratory bacterial species other than mycobacteria. A series of 128 sputa (89 MTB culture positive, 29 NTM culture positive, and 10 under treatment culture negative) with grades of trace to 4+ were used to evaluate the performance of the method. Results: The MTB- and NTM-specific PNA probes showed specific reactions with the reference strains of MTB and M. kansasii and clinical isolates of mycobacteria except M. fortuitum ATCC 6841, and no cross-reactivity with other tested bacteria. The PNA probe-based FISH assay for detection of MTB had a sensitivity and specificity of 100%, respectively. The sensitivity and specificity of the NTM-specific PNA probe was 100%. The smear grades of the PNA FISH test were same as with those of the fluorescence AFB stain in 2+ or higher grade. Conclusion: Detection and differentiation based on PNA FISH is sensitive and accurate for detecting mycobacteria and for differentiating MTB from NTM in clinical sputum smears.

Understanding of the Duplex Thrust System - Application to the Yeongwol Thrust System, Taebaeksan Zone, Okcheon Belt (듀플렉스트러스트시스템의이해 - 옥천대태백산지역영월트러스트시스템에의 적용)

  • Jang, Yirang
    • Economic and Environmental Geology
    • /
    • v.52 no.5
    • /
    • pp.395-407
    • /
    • 2019
  • The duplex system has been considered as an important slip-transfer mechanism to evaluate the evolution of orogenic belts. Duplexes are generally found in the hinterland portion of fold-thrust belts and accommodate large amounts of total shortening. Thus, understanding its geometric and kinematic evolution can give information to evaluate the evolution of the entire orogenic belt. Duplexes are recognized as closed-loop thrust traces on map view, indicating higher connectivity than imbricate fans. As originally defined, a duplex is an array of thrust horses which are surrounded by thrust faults including the floor and roof thrusts, and imbricate faults between them. Duplexes can accommodate regional layer-parallel shortening and transfer slip from a floor thrust to a roof thrust. However, an imbricate fault is not the only mean for layer-parallel shortening (LPS) and displacement transfer within duplexes. LPS cleavages and detachment folds can also play the same role. From this aspect, a duplex can be divided into three types; 1) fault duplex, 2) cleavage duplex and 3) fold duplex. Fault duplex can further be subdivided into the Boyer-type duplex, which was firstly designed duplex system in the 1980s that widely applied most of the major fold-thrust belts in the world, and connecting splay duplex, which has different time order in the emplacement of horses from those of the Boyer-type. On the contrary, the cleavage and fold duplexes are newly defined types based on some selected examples. In the Korean Peninsula, the Yeongwol area, the western part of the Taebaeksan Zone of the Okcheon Belt, gives an excellent natural laboratory to study the structural geometry and kinematics of the closed-loops by thrust fault traces in terms of a duplex system. In the previous study, the Yeongwol thrust system was interpreted by alternative duplex models; a Boyer-type hinterland-dipping duplex vs. a combination of major imbricate thrusts and their connecting splays. Although the high angled beds and thrusts as well as different stratigraphic packages within the horses of the Yeongwol duplex system may prefer the later complicate model, currently, we cannot choose one simple answer between the models because of the lack of direct field evidence and time information. Therefore, further researches on the structural field investigations and geochronological analyses in the Yeongwol and adjacent areas should be carried out to test the possibility of applying the fold and cleavage duplex models to the Yeongwol thrust system, and it will eventually provide clues to solve the enigma of formation and its evolution of the Okcheon Belt.

A Study on the Effect of University Library User's Sense of Community on User Satisfaction and Loyalty (대학도서관 이용자의 공동체의식이 이용자 만족도 및 충성도에 미치는 영향 연구)

  • Roh, Hyo Jin;Chang, Woo Kwon
    • Journal of the Korean Society for information Management
    • /
    • v.36 no.1
    • /
    • pp.137-168
    • /
    • 2019
  • This study measures and analyzes the university library user's sense of community, service quality assessment, user satisfaction and loyalty. In addition, the effect of the university library user's sense of community on university library user satisfaction and loyalty mediated by the assessment of the quality of service is investigated. On the basis of study result, to improve user satisfaction and user loyalty, the direction and implications of library development are presented. In order to achieve the purpose of the study, precedent research and literature were investigated, and the study model and hypothesis were established based on theoretical background. In order to verify the hypothesis, a total of 300 questionnaires were distributed to subject who had experience using the Central Library among undergraduate students at the C National University, and the final 282 sample was used for analysis. To analyze the differences depending on the general characteristics of the samples, It is the result of an independent sample t-test and one-way ANOVA. The results of the mediated effects analysis using the PROCESS macro-programs models 4 and 6 of Hayes for hypothesis testing are as follows. First, The university library user's sense of community (Service Benefits Perception and Satisfaction, Mutual sense of influence) effect the user satisfaction of university library mediated by service quality assessment at statistical significance. This showed that the higher the university library user's sense of community, the higher the service quality assessment, and the higher the user satisfaction level of university library. Second, The university library user's sense of community (Service Benefits Perception and Satisfaction, Mutual sense of influence) effect the user loyalty of university library mediated by service quality assessment and user satisfaction. This showed that the higher the university library user's sense of community, the higher the service quality assessment, the higher user satisfaction level of university library and the higher the user loyalty level of university library. The results of this study showed that the university library user's sense of community has a direct and indirect effect on enhancing user satisfaction and loyalty through the service quality assessment.

Comparison of the Outcomes according to the Injury Type of the Short Radiolunate Ligament in Fracture-Dislocation of the Radiocarpal Joint (요수근 관절의 골절-탈구에서 단요월상인대의 손상 형태에 따른 치료 결과의 비교)

  • Heo, Youn Moo;Kim, Tae Gyun;Song, Jae Hwang;Jang, Min Gu;Lee, Seok Won
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Radiocarpal dislocation (RCD), which is caused by high-energy trauma, often involves radial styloid fractures and short radiolunate ligament (SRLL) injuries. Although SRLL injuries may occur as a simple rupture at the attachment site of radius, it may occur with a relatively large avulsed-fragment in the volar rim of the lunate facet of the radius. This study aimed to differentiate the injury type of SRLL and assess the differences in the treatment results depending on the treatment methods that have been applied in RCD with radial styloid fractures. Materials and Methods: Eighteen patients managed surgically with RCD were enrolled in this study. The patients were classified as Group 1 and Group 2 by using the Dumontier method. In this study, Group 2 was subdivided into 2A (purely ligamentous or small avulsion fracture of the volar rim of lunate facet) and 2B (large avulsed-fragment enough to internal fixation) according to the injury type of SRLL. Groups 2A and 2B were treated with direct repair and screw fixation, respectively. Pain, range of motion of the wrist joint, grip strength, and complications on final radiographs were examined. The outcomes were evaluated using patient-rated wrist evaluation (PRWE), and modified Mayo wrist score (MMWS). Results: All patients were Group 2 (six and twelve patients in 2A and 2B, respectively). The mean flexion to extension arch recovered 79%,and the mean grip strength was 72.9% of the uninjured side. Group 2A showed better recovery in extension, flexion and pronation than Group 2B, but there was no difference in radial deviation, ulnar deviation, supination, grip strength and pain. No differences in the PRWE and MMWS were observed between two groups. Complications included traumatic arthritis in seven patients and residual instability in five patients. Conclusion: When the SRLL was injured, the involvement of a large avulsion fracture on the anterior plane of the radiolunate did not affect the test results. On the other hand, it should be observed cautiously because avulsion fractures tend to disturb the joint's reduction through rotation or displacement. In addition, anatomical reduction and sturdy internal fixation are important for restoring the function of the SRLL.

Effectiveness of Sodium Iodide Root Canal Filling Pastes in Primary Teeth (요오드화 나트륨을 사용한 유치 근관 충전재의 효과)

  • Soo Jin Chang;Yujin Kim;Junghwan Lee;Jongsoo Kim;Joonhaeng Lee;Mi Ran Han;Jisun Shin;Jongbin Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.2
    • /
    • pp.168-178
    • /
    • 2023
  • Objectives: This study aimed to compare the physical properties and antibacterial effectiveness of iodoform based root filling pastes, Vitapex® and Metapex®, with sodium iodide root filling paste (NaI paste) for primary teeth. Materials and Methods: The physical properties (flowability, film thickness, radiopacity) of the pastes were evaluated according to ISO 6876:2012. The antibacterial activity against Enterococcus faecalis strain (ATCC 6538) was evaluated using a direct contact test. Results: There was no significant statistical difference (p > 0.05) observed in the flow and film thickness of NaI paste when compared to the currently available root canal filling materials. The average flow capacities for Vitapex®, Metapex®, and NaI paste were 15.40 mm, 21.25 mm, and 20.01 mm, respectively. The average film thickness for Vitapex®, Metapex®, and NaI paste were 33.3 ㎕, 22.6 ㎕, and 25.0 ㎕, respectively. However, NaI paste showed lower radiopacity than the existing materials, and this difference was statistically significant (p < 0.05) NaI paste demonstrated higher antimicrobial activity than the available materials, and this difference was also statistically significant (p < 0.05). Conclusion: Compared to the existing commercialized root canal filling materials, NaI paste exhibited similar performance in terms of flow and film thickness, and superior antimicrobial activity against E. faecalis. Hence, NaI paste could be a promising root filling material for primary teeth and may be a potential alternative to existing materials.

Fertigation Techniques Using Fertilizers with Peristaltic Hose Pump for Hydroponics (연동펌프를 이용한 비료염 공급 관비재배기술 연구)

  • Kim, D.E.;Lee, G.I.;Kim, H.H.;Woo, Y.H.;Lee, W.Y.;Kang, I.C.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2015
  • This study was conducted to develop the fertigation system with a peristaltic hose pump and brushless DC motor. The fertigation system was consisted of sensor, main controller, motor control unit, peristaltic pump, water supply pump, control panel, and filter. The peristaltic pump discharges liquid by squeezing the tube with rollers. Rollers attached to the external circumference of the rotor compresses the flexible tube. The fluid is contained within a flexible tube fitted inside a circular pump casing. The developed fertigation system has no mixing tank but instead injects directly a concentrated nutrient solution into a water supply pipe. The revolution speed of the peristaltic pump is controlled by PWM (Pulse width modulation) method. When the revolution speed of the peristaltic pump was 300rpm, the flow rate of the 3.2, 4.8, 6.3mm diameter tube was 202, 530, 857mL/min, respectively. As increasing revolution speed, the flow rate of the peristaltic pump linearly increased. As the inner diameter of a tube larger, a slope of graph is more steep. Flow rate of three roller was more than that of four roller. Flow rate of a norprene tube with good restoring force was more than that of a pharmed tube. As EC sensor probe was installed in direct piping in comparison with bypass piping showed good performance. After starting the system, it took 16~17 seconds to stabilize EC. The maximum value of EC was 1.44~1.7dS/m at a setting value of 1.4dS/m. The developed fertigation system showed ±0.06dS/m deviation from the setting value of EC. In field test, Cucumber plants generally showed good growth. From these findings, this fertigation system can be appropriately suitable for fertigation culture for crops.

Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water - (지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 -)

  • Lee, W.Y.;Ahn, D.H.;Kim, S.C.;Park, W.P.;Kang, Y.G.;Kim, S.B.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.4 no.1
    • /
    • pp.128-137
    • /
    • 2002
  • This study was conducted to develop the heat exchanger by utilizing the heat energy of underground water(15℃), which might be used for cooling and heating system of the agricultural facilities. We developed the heat exchanger by using the parallel type plat fin tube made of Aluminum(Al 6063), which was named Aloo-Heat(No. 0247164, offered by Korean Intellectual property Office). The trial manufactures were made from Aloo-heat which was 600mm, 700mm length respectively, and It were welded to the end "U" type in order to direct flow of the underground water. The performance test was carried out under the condition of open space and room temperature with the change of flow rate of the underground water and air. The results are as follows. 1. The trial manufactures had convection heat value from 33 to 156 W/m2℃, and It was coincided with design assumption. 2. The amount of energy transfer was increased with the increment of the area of heat transfer, the air flow, the gap of temperature inlet & outlet the underground water and the air. 3. The heat value was 6,825W when the air flow was 6,000m3/h and the gap of temperature between inlet and outlet of the underground water was 6℃, and It dropped from 25.8℃ to 23.2℃(-2.6℃ difference). The convection heat value was 88.5W/m2℃. 4. The heat value was 2.625W when the air flow was 4,000m3/h and the gap of temperature between inlet and outlet the underground water was 2℃, and It dropped from 27℃ to 22.5℃(-4.5℃ difference). The convection heat value was 33.6W/m2℃. 5. Correlation values(R2) of the testing heat values of the trial manufacture type I, II, and III were 0.9141, 0.8935, and 0.9323 respectively, and correlation values(R2) of the amount of the air flow 6,000m3/h, 5,000m3/h, 4,000m3/h were 0.9513, 0.9414, and 0.9003 respectively.